| Brand | Changji Instruments |
|---|---|
| Origin | Shanghai, China |
| Model | WNE-1A |
| Temperature Range | 0–100 °C |
| Temperature Accuracy | ±0.2 °C |
| Standard Water Value | (51 ± 1) s |
| Effluent Volume | (200 ± 0.2) mL |
| Heating Power | 550 W (AC 220 V, 50 Hz) |
| Compliance | GB/T 266, GB/T 514, Q/YXYY11 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | 57701 |
| Temperature Range | 0–180 °C |
| Compatibility | Ubbelohde, Ostwald, and Cannon-Fenske capillary viscometers |
| Mounting Options | Standard 4-hole viscometer holder (Ø4/6/8/10 mm) |
| Sensor Interface | Pt-100 RTD port with 2-wire or 4-wire configuration |
| Fluid Circulation | Compatible with CD-200F thermostatic circulator (external) |
| Sealing | ND60 O-ring (22534) and NW60 quick-clamp (07234) included |
| Pump Integration | Supports VZ 5655 VISCO Pump for automated efflux timing |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ALPHA |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 60 – 40,000,000 cP |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Speed Range | 0.3–100 rpm |
| Speed Steps | 18 |
| Viscosity Accuracy | ±1% of full scale |
| Viscosity Repeatability | ±2% of full scale |
| Display Resolution | 0.01–1 cP |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Interface | USB-B |
| Compliance | CE, RoHS |
| Language Support | 7 languages (including English, German, French, Spanish, Italian, Chinese, Japanese) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model Series | APM / LCP / Heldal |
| Pricing | Upon Request |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Instrument Type | Capillary Viscometer |
| Design | Portable |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.35 – 100,000 mm²/s |
| Compliance | ISO/DIS 3105, ASTM D2515, ASTM D466, NF T 60-100, BS 188, GB/T 11137, SH/T 0654, ISO/IEC 17025 (calibrated at 40 °C and 100 °C) |
| Sample Compatibility | Transparent or opaque liquids |
| Fill Volume | 7–12 mL |
| Total Length | 245–295 mm |
| Calibration | Factory-calibrated with certified K-values and annular timing marks |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model Numbers | 05392, 05393, 05396, 05397, 06499 |
| Material Options | Stainless Steel (05392–05397), Polyamide (06499) |
| Angular Tolerance | < 1° |
| Compatibility | Ubbelohde, TC Ubbelohde, Cannon-Fenske Reverse Flow, Micro-Ostwald, Ostwald, and Cannon-Fenske Routine viscometers |
| Application | Manual and automated capillary viscometry in thermostatted baths |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | CV003-100 / CV003-001 |
| Instrument Type | Portable Capillary Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.3 – 50,000 mm²/s (cSt) |
| Fill Volume | 11 mL |
| Accuracy | ±0.2% |
| Compliance | DIN 51562-1, ISO 3105, ASTM D445, ASTM D2515, ISO 3104, UNE 400313 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | CV005-001 |
| Instrument Type | Portable Capillary Viscometer |
| Viscosity Range | 0.6 – 30,000 mm²/s (cSt) |
| Capillary Diameter | 0.4 mm |
| Compliance | ASTM D445, ISO 3104, ISO 3105, GB/T 265, SH/T 0173 |
| Sample Requirement | Clear, Newtonian or near-Newtonian liquids |
| Operating Environment | Ambient temperature (15–30 °C) |
| Measurement Principle | Gravimetric capillary flow time |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | 53100 |
| Instrument Type | Portable Capillary Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.3 – 60 mm²/s |
| Fill Volume | 15 – 75 mL |
| Total Length | ~290 mm |
| Capillary Inner Diameter Options | 0.36–1.15 mm |
| Calibration Constant (K) Range | 0.001–0.1 mm²/s |
| Compliance | ASTM D445, ISO 3104, IP 71 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | FCI003 |
| Standard | ISO 2431 |
| Orifice Diameter | 3 mm |
| Viscosity Range | 5–42 cSt |
| Instrument Type | Fixed-geometry efflux viscometer |
| Application Environment | Ambient temperature (25 °C standard) |
| Compliance | ISO 2431, ASTM D1200 (cross-referenced), DIN 53211 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | ISP-1, ISP-2, ISP-1HD |
| Application | Polymer, pulp, and HDPE/PP sample preparation for rotational rheometry and capillary viscometry |
| Compliance | Designed for GLP-compliant workflows with audit-trail-ready data transfer to RPV-1 viscosity software |
| Safety | Integrated self-diagnostic routines and real-time error detection |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | 53610 / 57210 |
| Viscometer Type | Capillary (Ubbelohde) |
| Design Standard | DIN 55350-18, DIN 55526-2, DIN 51562-2 |
| Capillary Geometry | Dilution-type, suspended-level |
| Operating Temperature Range | 10–80 °C (standard), optional -40 to +30 °C or 70 to 150 °C variants |
| Kinematic Viscosity Range | 0.4–8000 mm²/s |
| Sample Volume | 3–4 mL |
| Total Length | ~290 mm (536xx/537xx/538xx), ~350 mm (572xx/573xx/574xx) |
| Calibration | Certified K-value (4 significant digits) available for 536xx (manual use) and 537xx/572xx/573xx (automated systems) |
| Compliance | Traceable to national standards with factory calibration certificate included |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model Series | 1625, 1628, 1631 |
| Viscometer Type | Suspension-level (Ubbelohde-type) capillary viscometer |
| Portability | Portable |
| Operating Environment | Ambient temperature |
| Kinematic Viscosity Range | 0.6 – 100,000 mm²/s (cSt) |
| Calibration Compliance | ISO/IEC 17025-accredited |
| Sample Requirement | Transparent Newtonian or near-Newtonian liquids |
| Fill Volume | 4–40 mL |
| Total Length | 250–330 mm |
| Capillary Stand Compatibility | BS/IP/SL and BS/IP/MSL standards (A1/A2 series adapters) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model Numbers | 51610, 50903 |
| Instrument Type | Capillary Viscometer (Ostwald-type) |
| Portability | Portable |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.4 – 800 mm²/s |
| Calibration | Pre-calibrated with certified capillary constants (K-values) |
| Fill Volume | 2–3 mL |
| Total Length | 220–290 mm |
| Compliance | Designed for ASTM D445, ISO 3104, and IP 71 standard test methods |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | PREMIUM |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–320,000,000 mPa·s |
| Temperature Range | −40 to +300 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.2 °C |
| Speed Range | 0.01–250 rpm (2600 selectable speeds) |
| Viscosity Accuracy | ±1% of full scale |
| Repeatability | ±0.2% |
| Compliance Standards | ASTM D1076, D1084, D1286, D1417, D1439, D1638, D1824, D2196, D2336, D2364, D2393, D2556, D2669, D2849, D2983, D2994, D3232, D3236, D3716 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | PULP |
| Instrument Type | Benchtop Fixed-Position Viscometer |
| Operating Environment | Ambient Temperature |
| Compliance Standards | ISO 5351:2004, SCAN-CM 15:99, ASTM D1795, ASTM D4243, TAPPI T230 om-94, PAPTAC G.2423P |
| Measurement Resolution | 0.001 s |
| Sample Capacity | 70 × 40 mL Bottles |
| Solvent Resistance | Phenol, Acetic Acid, Cyclohexane, Acetone |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | RPV-1 |
| Instrument Type | Benchtop Fixed-Position System |
| Operating Environment | Ambient Temperature |
| Compliance | ASTM D445, D789, D1243, D4603 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | RUV-2 |
| Instrument Type | Benchtop Fixed-Position Viscometer |
| Application Environment | Ambient Laboratory Conditions |
| Kinematic Viscosity Range | 1 – 1000 mm²/s (cSt) |
| Temperature Range | 40 – 100 °C |
| Temperature Stability | ±0.01 °C |
| Capillary Type | ASTM Ubbelohde Viscometers (ISO 17025-calibrated) |
| Measurement Positions | 2 |
| Solvent Cleaning & Vacuum Drying | Integrated |
| Power Supply | 100–240 VAC, Max 600 W |
| Dimensions (W × L × H) | 395 × 590 × 580 mm |
| Weight | 75 kg |
| Interfaces | RS232, USB, VGA |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | SCAN Viscometer |
| Instrument Type | Portable Capillary Viscometer |
| Compliance | ISO 5351 (Pulp Viscosity) |
| Operating Environment | Ambient Temperature |
| Application | Manual Viscosity Measurement of Cellulosic Pulps |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Product Type | Capillary Viscometer |
| Instrument Category | Kinematic & Dynamic Viscosity Measurement |
| Compliance | UKAS-accredited calibration, ISO/IEC 17025, ASTM D446, ASTM D2171, ISO 3105, IP 71 Part 2, BS 188, EN 12596 |
| Models | 1638 (Shell Reverse Flow), 1647 (Cannon-Ubbelohde), 1659 (Cannon-Manning Semi-Micro), 1677 (Asphalt Institute Vacuum), 1678 (Modified Koppers Vacuum), 1676 (Cannon-Manning Vacuum) |
| Kinematic Viscosity Range | 0.0036–300,000 mm²/s |
| Dynamic Viscosity Range | 4.2–580,000 Pa·s |
| Operating Environment | Ambient temperature (20–25 °C), laboratory benchtop use |
| Calibration | Individually UKAS-certified with traceable K-value (mm²/s)²/s and documented uncertainty budgets |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | Smart |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Temperature Range | 0–100 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Speed Range | 0.3–100 rpm |
| Speed Steps | 18 |
| Viscosity Accuracy | ±1% of full scale |
| Repeatability | ±2% of full scale |
| Display Resolution | 0.01–1 cP |
| Compliance | ASTM D2196, ISO 2555, ISO 3219, USP <911> |
| Data Interface | USB-B |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Key | Brand: ChemTron |
|---|---|
| Origin | Germany |
| Instrument Type | Capillary Viscometer (Ubbelohde-type) |
| Portability | Benchtop / Modular Integration |
| Operating Temperature Range | –40 °C to +150 °C (model-dependent) |
| Kinematic Viscosity Range | 0.5–30,000 mm²/s (cSt) |
| Compliance | DIN 51562-1, ISO 3105 (BS-IP-SL), ASTM D445 |
| Calibration | Factory-calibrated with certified K-values |
| Capillary Dimensions | Bore diameters from 0.47 mm to 5.35 mm |
| Total Length | ~355 mm |
| Detector Option | Integrated thermal conductivity detector (for opaque & wall-adhering samples) |
| Compatibility | AVS 24 / AVS 26 / AVS 270 automated filling & cleaning systems |
| Material | Borosilicate glass (DIN/ISO-compliant), precision-ground glass threads |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Instrument Type | Capillary Viscometer (U-Tube, Reverse-Flow & Standard) |
| Calibration | ISO/IEC 17025-accredited |
| Viscosity Range | 0.2 – 300,000 mm²/s |
| Fill Volume | 4 – 40 mL |
| Tube Length | 250 – 300 mm |
| Portability | Benchtop / Manual Operation |
| Compliance | ASTM D445, ISO 3104, IP 71, BS EN ISO 3104, USP <911> |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | 1643 / 1671 / 1690 |
| Viscometer Type | Capillary (Ubbelohde) |
| Portability | Portable |
| Operating Environment | Ambient Temperature |
| Kinematic Viscosity Range | 0.3 – 100,000 mm²/s |
| Calibration Standard | ISO/IEC 17025 |
| Accreditation | UKAS (for 1690 series) |
| Capillary Constant (K) | 0.001 – 100 mm²/s² |
| Fill Volume | 18 mL |
| Total Length | 283 mm (1643), 580 mm (1690) |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Type | Capillary Viscometer |
| Design | Ubbelohde (Dilution-Compensated) |
| Compliance | DIN 51562-1, ISO 3105, ASTM D2515, ASTM D446 |
| Calibration | NIST-traceable K-value certified (4 significant figures, optional) |
| Capillary Diameter Range | 0.24–6.30 mm |
| Kinematic Viscosity Range | 0.35 to >100,000 mm²/s |
| Fill Volume | 15–22 mL |
| Total Length | 285–290 mm |
| Material | Borosilicate Glass 3.3 (DURAN®) |
| Application | Transparent Newtonian & near-Newtonian Liquids |
| Mounting | Threaded Stem with Integrated Cleaning Tube (Models 541xx & 545xx) |
| Configuration | Manual or Automated Compatibility |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | 1663 |
| Instrument Type | Portable Capillary Viscometer |
| Viscosity Range | 0.6 – 100,000 mm²/s |
| Calibration Compliance | ISO/IEC 17025 |
| Fill Volume | 3 mL |
| Total Length | 295 mm |
| Capillary Constant (K-value) Range | 0.003 – 100.0 mm²/s² |
| Available K-value Codes | 1663/01 to 1663/10 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | V92101 |
| Instrument Type | Portable Falling-Ball Viscometer |
| Viscosity Range | 0.6–75,000 mPa·s |
| Temperature Range | −20 to +120 °C |
| Temperature Resolution | 0.1 °C |
| Measuring Tube Internal Diameter | 15.95 mm |
| Compliance | DIN 53015, ISO 12058 |
| Display | LED with digital temperature readout |
| Thermal Control | External jacketed bath (10 mm OD inlet/outlet ports) |
| Standard Accessories | Calibrated ball set (V92101–V92106), tweezers, cleaning brush, factory calibration certificate |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VACS-EN12596 |
| Instrument Type | Fixed Rotational Viscometer (Capillary Vacuum Method) |
| Compliance | ASTM D2171, EN 12596 |
| Operating Environment | Ambient Temperature |
| Vacuum Control | Digital Vacuum Controller with Membrane Pump |
| Temperature Stability | ±0.1 °C (when used with TCB-7 bath) |
| Sample Measurement Principle | Capillary Efflux Time under Controlled Vacuum |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VICSO 380 |
| Instrument Type | Rotational Viscometer-Based Capillary Viscometry System |
| Viscosity Range | 5–100 mPa·s |
| Temperature Stability | ±0.01 °C |
| Efflux Time Resolution | 0.001 s |
| Mass Accuracy | 0.01 mg or 0.1 mg |
| Compliance | ASTM D445, D789, D1243, D4603 |
| Brand | ChemTron |
|---|---|
| Origin | Germany |
| Model | VISCO 070 |
| Instrument Type | Fixed-Position Capillary Viscometer System |
| Operating Environment | Ambient Temperature |
| Compliance | ASTM D445, ISO 3104, IP 71, GB/T 265 |
| Standard Accessories | Ubbelohde-type glass capillary viscometer, thermostatically controlled viscosity bath (±0.01 °C stability), viscometer stand, calibrated thermometer (±0.02 °C), digital stopwatch (resolution ≥0.1 s |