Rheometer/Viscometer
Filter
Showing 91–120 of 207 results
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RSX-CC |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Applicable Instrument Series | LV, RV, HA, HB |
| Shear Rate | 0.677 s⁻¹ per revolution |
| Viscosity Range (LV Series) | up to 100 k cP |
| Viscosity Range (RV Series) | up to 1.1 M cP |
| Viscosity Range (HA Series) | up to 2.2 M cP |
| Viscosity Range (HB Series) | up to 9.0 M cP |
| Unit Equivalence | 1 cP = 1 mPa·s |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | SSA |
| Sample Volume Range | 2–16 mL |
| Geometry | Cylindrical Couette-type |
| Compatible Instruments | All Brookfield DV-series viscometers and rheometers (DV-I+, DV-II+ Pro, DV-III+, DVNext, RST series) |
| Temperature Control | External water bath circulation via jacketed cup (−15 °C to 100 °C) |
| Optional RTD Integration | Yes (direct temperature readout on DV-I+/II+/III+ displays) |
| Disposable Cup Option | Aluminum single-use cup (SC4-13RD-100, pack of 100) |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | SSA |
| Sample Volume | 2–16 mL |
| Temperature Control Range | –15 °C to 100 °C (with optional RTD probe) |
| Compatible Instruments | All Brookfield DV-series viscometers and RST/ARES rheometers |
| Minimum Measurable Viscosity | ≥1 cP (mPa·s) |
| Shear Rate Range | 0.25–2.2 s⁻¹ (dependent on spindle/chamber combination) |
| Spindle Types | SC4-series (e.g., SC4-14, SC4-15, SC4-21, SC4-27, SC4-28, SC4-29, SC4-31, SC4-34) |
| Sample Chamber Types | SC4-6R(P), SC4-7R(P), SC4-8R(P), SC4-13R(P), SC4-13RPY, SC4-13RD-100 |
| Optional Accessories | Water-jacketed mounting bracket, SC4 spindles, disposable aluminum chambers, RTD-integrated chambers, thermal insulation lid, extension hook assembly |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | Thermosel |
| Temperature Range | Up to 300°C |
| Controller Type | Programmable (1–10 setpoints) |
| Compatible Instruments | DV2T, DV3T, and select Brookfield digital viscometers/rheometers |
| Required Accessories | DVP-141 cable (for basic operation) |
| Included Components | SC4-series spindle (user-specified), alignment stand, insulated heating furnace with safety guard and thermal cap, 1 reusable sample cup, 5 disposable sample cups (HT-2DB-100 optional), 18" instrument stand, sampling tool, RTD temperature probe |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | THERMOSEL |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ULA |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | ULA |
| Pricing | Available Upon Request |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Type | Newtonian Calibration Fluids |
| Variants | General-Purpose Silicone Oil Standards, High-Temperature Silicone Oil Standards, Hydrocarbon (Mineral Oil / Polybutene) Standards, CAP-Series Spindle-Specific Standards, KU-2 Krebs Units Standards, RST/RheoStress Coaxial & Cone Standards |
| Viscosity Range | 5–360,000 cP (mPa·s) at 25.0°C |
| Accuracy | ±1% of nominal viscosity |
| Temperature Stability | ≤±0.5% per °C (silicone oils) |
| Certified Traceability | NIST-traceable calibration documentation available upon request |
| Packaging | 600 mL glass or 1000 mL HDPE bottles |
| Brand | Brookfield |
|---|---|
| Origin | USA |
| Model | VTE |
| Instrument Type | In-line Viscometer |
| Viscosity Range | 10–10,000 cP |
| Output Signal | 4–20 mA (linear) |
| Accuracy | ±1% of full scale |
| Control Relay | 3 A solenoid-type |
| Enclosure Rating | NEMA 1 |
| Operating Environment | Ambient temperature |
| Compliance | Designed for continuous industrial process monitoring |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CAV4.1 |
| Instrument Type | Capillary Viscometer (Fixed Benchtop) |
| Kinematic Viscosity Range | 0.5–10,000 mm²/s (cSt) |
| Temperature Range | 20–150 °C |
| Temperature Resolution & Accuracy | ±0.01 °C |
| Compliance | ASTM D445, ASTM D446, ISO 3104, ISO 3105, IP 71, GB/T 265 |
| Sample Throughput | Dual-capillary parallel measurement |
| Integrated Control | Built-in industrial PC + 10.4″ color touchscreen |
| Software | VISCPRO (supports up to 4 CAV4.1 units per host PC) |
| Cleaning & Drying | Automated solvent rinse and compressed-air drying |
| Capillary Exchange | Tool-free, bath-oil–retaining design |
| Calibration | Single-point temperature calibration per capillary |
| Status Indication | Multi-color LED status lighting |
| Power Supply | 100–240 VAC, 50/60 Hz |
| Certifications | CE |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CAV4.2 |
| Instrument Type | Fixed-Position Capillary Viscometer |
| Viscosity Range | 0.5–10,000 cSt |
| Temperature Range | 15–150 °C |
| Temperature Resolution | ±0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Compliance | CE Certified |
| Sample Throughput | Up to 24 samples unattended (1-hour cycle) |
| Display | 10.4-inch color touchscreen |
| Solvent Consumption Reduction | ~50% vs. conventional capillary systems |
| Cleaning Method | Automated air purge and solvent rinse |
| Capillary Options | Ubbelohde or ATLANTA-type viscometers |
| Calibration | Single-point temperature calibration per capillary |
| Sample Preheating | Individual sample heating up to 100 °C |
| Operating Environment | Ambient laboratory conditions |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CCS-2100F |
| Instrument Type | Rotational Viscometer (Cold Cranking Simulator) |
| Temperature Range | −35 °C to −5 °C |
| Temperature Resolution & Accuracy | ±0.05 °C |
| Apparent Viscosity Range | 1,500–27,000 mPa·s |
| Compliance | ASTM D5293, SAE J300-99, GB/T 6538 |
| Cooling Method | Solid-State Thermoelectric (No Refrigerants) |
| Sample Throughput | 30 Samples per Unattended Run |
| Control System | Windows-Based PC with CCS-RA Interface and LIMS-Ready Software |
| Power Supply | 230 V / 50 Hz / 1000 W |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CCS-2100LT |
| Instrument Type | Rotational Viscometer (Fixed-Base, Cold-Bath Configuration) |
| Temperature Range | −5 °C to −40 °C |
| Temperature Resolution & Accuracy | ±0.05 °C |
| Apparent Viscosity Range | 1500 mPa·s to 21000 mPa·s |
| Cooling Method | Solid-State Thermoelectric (Peltier) |
| Compliance | ASTM D5293, SAE J300-99, GB/T 6538 |
| Sample Throughput | Up to 30 samples per automated sequence |
| Control & Data Handling | PC-based automation with self-calibration routines and integrated wash cycle with programmable heating profile |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CCS2100-G6 |
| Instrument Type | Rotational Viscometer (Fixed-Base, Low-Temperature CCS) |
| Temperature Range | −40 °C to −5 °C |
| Temperature Accuracy | ±0.05 °C |
| Temperature Resolution | ±0.05 °C |
| Viscosity Range | 900–25,000 mPa·s (cP) |
| Compliance | ASTM D5293, SAE J300, GB/T 6538 |
| Sample Capacity | 14 samples (unattended) |
| Cleaning Method | Solvent-Free In-Situ Sample Flush |
| Calibration | Auto-Rotational Speed Calibration & User-Verifiable Temperature Calibration |
| Software | FlowHub™ Data Management Platform |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CMRV-4500F |
| Instrument Type | Rotational Viscometer (Fixed-Mount) |
| Temperature Range | –5 °C to –40 °C |
| Temperature Resolution | ±0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Cooling Method | Thermoelectric (Peltier) with Fluorine-Free Coolant Circulation |
| Compliance | ASTM D3829, D4684, D6896, D6821, SAE J300, GB/T 9171, SH/T 0562 |
| Software Platform | Windows 98/NT/XP Compatible Control System |
| Optional Accessory | Dedicated Rotor Kit for ASTM D6821 |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CT-2000 |
| Temperature Control Range | 20 °C to 150 °C |
| Temperature Stability | ±0.01 °C |
| Compliance | ASTM D445, ISO 3104 |
| Communication Interfaces | RS-232, RS-485 |
| Bath Capacity | 7 × 51 mm viscometer ports + 2 auxiliary thermometer ports |
| Display | 4-line LCD with digital setpoint & actual temperature readout |
| Input Method | Keypad entry of two-digit decimal setpoints |
| Temperature Unit Toggle | °C / °F |
| Self-Diagnostic Function | Power-on system check |
| Calibration Offset Entry | Manual mercury thermometer correction via keypad |
| Cooling Option | External tap water or chiller connection |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | CT-2000F |
| Instrument Type | Fixed-Position Constant-Temperature Bath |
| Application | Capillary Viscometry |
| Temperature Range | 10 °C to 100 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Bath Capacity | 17 L |
| Power Supply | 240 V, 50/60 Hz, 1400 W |
| Dimensions (W×D×H) | 438 mm × 464 mm × 584 mm |
| Net Weight | 51.4 kg |
| Compliance | ASTM D445, ISO 3104 |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | DVR-1000 |
| Instrument Type | Fixed-Position Vacuum Viscometer |
| Operating Temperature Range | 0–40 °C |
| Vacuum Accuracy | ±0.5 mmHg at 300 mmHg setpoint |
| Compliance | ASTM D2171 |
| Display | Digital LED |
| Control Interface | Front-panel membrane keypad |
| Sensing Element | Solid-state pressure transducer (mercury-free) |
| Application Focus | Bitumen and asphalt viscosity testing under controlled vacuum |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | HTHS-II |
| Instrument Type | Capillary Viscometer |
| Standards Compliance | ASTM D5481, SAE J300, SH/T 0703-2001 |
| Operating Temperature | 150 °C |
| Shear Rate | 1.4 × 10⁶ s⁻¹ |
| Sample Throughput | 15–20 samples/hour |
| Safety Features | Inlet valve interlock, overtemperature cutoff |
| Software | Windows-based HTHS viscosity calculation software |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniAV |
| Instrument Type | Capillary Viscometer (Fixed-Station, Benchtop) |
| Viscosity Range | 0.5–10,000 mm²/s (cSt) |
| Temperature Range | 15–100 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C (at setpoint) |
| Compliance | ASTM D445, ASTM D446, ISO 3104, ISO 3105 |
| Sample Volume | 5–10 mL per test |
| Bath Volume | 1 L |
| Dimensions | 254 mm (W) × 533 mm (H) × 381 mm (D) |
| Connectivity | RS-232 |
| Software | VISCPRO II (Windows 98/NT/XP compatible) |
| Multi-unit Control | Up to 4 units per PC |
| LIMS Integration | Yes |
| Operating Humidity | 10–90% RH (non-condensing) |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniAV-LT |
| Instrument Type | Capillary Viscometer (Fixed-Station) |
| Kinematic Viscosity Range | up to 20,000 mm²/s |
| Temperature Range | −40 °C to +30 °C |
| Temperature Stability | ±0.05 °C |
| Compliance | ASTM D445, D1655, D2532, ISO 3104, ISO 3105, IP 71, DEF STAN 91-91, GB/T 265 |
| Cooling Method | Integrated Peltier Thermoelectric System with Air–Water Heat Exchange |
| Sample Volume | ~6 mL |
| Cleaning & Drying | Automated solvent rinse and thermal drying at +30 °C |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniPV |
| Instrument Type | Capillary Viscometer (Fixed-Station) |
| Viscosity Range | 0.3–20,000 cSt |
| Temperature Range | 15–100 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Accuracy | ±0.01 °C |
| Sample Volume | ~15 mL |
| Flow Time Resolution | 0.01 s |
| Cooling Method | Peltier-based (no external chiller required) |
| Sample Capacity | 10-position auto-sampler |
| Cleaning System | Dual-solvent + compressed air drying |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniPV-HX |
| Instrument Type | Capillary Viscometer (Ubbelohde-type, modified) |
| Mounting | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.3–1,200 mm²/s (cSt) |
| Temperature Range | 15–100 °C |
| Temperature Resolution | 0.001 °C |
| Temperature Accuracy | ±0.01 °C |
| Flow Time Resolution | 0.01 s |
| Sample Volume | ~15 mL |
| Sample Capacity | 10-position autosampler |
| Cleaning | Dual-solvent rinse + compressed-air drying |
| Thermal Control | Peltier-based cooling/heating (no external chiller required) |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | miniQV-X |
| Instrument Type | Fixed-Position Capillary Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.5–10,000 mm²/s |
| Compliance | ASTM D445 |
| Sample Throughput | <3 min per sample |
| Automation | 25-position Rotating Autosampler with Integrated Cleaning & Drying |
| Configuration | Sample-to-Sample Mode |
| Category | Physical Property Testing Instrument / Capillary Viscometer |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | PolyVISC |
| Instrument Type | Capillary Viscometer |
| Temperature Range | 20–100 °C (optional 135 °C) |
| Temperature Stability | ±0.01 °C |
| Efflux Time Resolution | ±0.01 s |
| Viscosity Range | 0.3–20,000 cSt |
| Solvent Compatibility | Broad (including chlorinated, phenolic, and high-boiling solvents) |
| Compliance | ASTM D2857, ASTM D4603, ISO 307, USP <911>, FDA 21 CFR Part 11 (audit trail enabled in VISCPRO) |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Model | Ravenfield BS/C+ HTHS Viscometer |
| Instrument Type | Benchtop Fixed-Position Viscometer |
| Viscosity Range | 0–30 cP |
| Temperature Range | 40 °C to 180 °C |
| Temperature Resolution & Accuracy | ±0.02 °C |
| Shear Rate Range | 1×10⁵ s⁻¹ to 2×10⁶ s⁻¹ |
| Test Cycle Time | <5 min per sample |
| Repeatability | ≤2% RSD |
| Compliance | ASTM D4741, ASTM D4683 (correlative), SAE J300, ACEA Specifications |
| Optional Accessories | DR-Series Automated Sampler (up to 22 samples), LIMS Interface Module, Integrated Thermal Printer |
| Brand | CANNON |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TE-1500F / TE-3000F |
| Instrument Type | Fixed-Position Capillary Viscometer |
| Operating Environment | Ambient Laboratory |
| Temperature Range | –30 °C to +10 °C (TE-1500F) / –30 °C to +30 °C (TE-3000F) |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Compliance | ASTM D445, ISO 3104, GB/T 265 |
| Brand | Cannon |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | TE-BBR |
| Instrument Type | Bending Beam Rheometer |
| Bearing Type | Air-bearing |
| Minimum Oscillation Frequency | 0.1 Hz |
| Frequency Range | 0.1–100 Hz |
| Maximum Oscillation Frequency | 100 Hz |
| Maximum Applied Load | 45 g (0.441 N) |
| Load Resolution | 0.015 g (0.147 mN) |
| Displacement Resolution | 0.155 µm |
| Temperature Control Stability | ±0.03 °C |
| Minimum Operating Temperature | –36 °C |
| Cooling Method | Thermoelectric (Peltier) with Air/Water Heat Exchange |
| Interface | RS-232 Serial |
| Software Platform | Windows 95/NT (v3.51 or later) |
| System Requirements | IBM-compatible PC, SVGA monitor, 16 MB RAM, 20 MB free HDD space, 1.44 MB floppy drive |
| Brand | Cannon |
|---|---|
| Origin | USA |
| Model | TESC |
| Instrument Type | Rotational Viscometer (Fixed-Base, Benchtop) |
| Viscosity Range | 0.1–10,000 mPa·s |
| Temperature Range | −40 °C to +90 °C |
| Temperature Resolution | 0.1 °C |
| Temperature Accuracy | ±0.1 °C |
| Compliance | ASTM D2983, GB/T 11145 |
| Cooling Method | Solid-State Thermoelectric (Peltier) |
| Rotor Adjustment | Motorized, Tool-Free |
| Footprint | Compact, Multi-Unit Stackable |