Rheometer/Viscometer
Filter
Showing 151–180 of 207 results
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Rotational Viscometer |
| Mounting Type | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 15–6,000,000 mPa·s |
| Temperature Range | −100 to 300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01–200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Accuracy (FSR) | ±1% |
| Repeatability (FSR) | ±0.2% |
| Motor Power | 4.8 W |
| Display | 4.3″ TFT Touchscreen |
| Interfaces | RS-232, USB |
| Protection Rating | IP40 |
| Dimensions (W×H×D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | ROTAVISC me-vi Complete |
| Instrument Type | Benchtop Fixed-Position Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 100 – 40,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Torque Range | 0.7187 mN·m |
| Viscosity Accuracy (FSR) | ±1 % |
| Viscosity Repeatability (FSR) | ±0.2 % |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Interface | RS232, USB |
| IP Rating | IP40 |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer | IKA-Werke GmbH & Co. KG |
| Product Type | Rotational Viscometer |
| Mounting Type | Benchtop Fixed System |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 100 – 40,000,000 mPa·s |
| Temperature Range | −100 to +300 °C |
| Temperature Accuracy | ±0.1 K |
| Speed Range | 0.01 – 200 rpm |
| Speed Accuracy | ±0.01 rpm |
| Torque Measurement Range | 0.7187 mN·m |
| Viscosity Accuracy (FSR) | ±1% |
| Viscosity Repeatability (FSR) | ±0.2% |
| Display | 4.3″ TFT Touchscreen |
| Interface | RS-232, USB |
| IP Rating | IP40 |
| Power Supply | 100–240 V AC, 50/60 Hz |
| Dimensions (W × H × D) | 351 × 629 × 372 mm |
| Weight | 7.1 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model Range | ROTAVISC lo-vi / me-vi / hi-vi I / hi-vi II Complete |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–6,000,000 mPa·s |
| Temperature Control Range | −100 °C to +300 °C |
| Temperature Resolution | 0.1 K |
| Accuracy | ±1 % of full scale |
| Repeatability | ±0.2 % of full scale |
| Speed Control | Continuously Variable (0.01–1,000 rpm) |
| Origin | USA |
|---|---|
| Manufacturer | Kaltec (USA) |
| Instrument Type | Rotational Rheometer |
| Max Shear Rate | 1–1.38×10⁵ s⁻¹ (standard), up to 1.85×10⁵ s⁻¹ (upgraded) |
| Torque Range | 1.0×10⁴–1.8×10⁷ dyn·cm |
| Shear Stress Range | 80–6.0×10⁵ dyn/cm² |
| Recommended Viscosity Range | 1–4.5×10³ cP (10⁻² P) |
| Weight | 62 kg |
| Dimensions (H×W×D) | 81×64×46 cm |
| Brand | LISICO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic (China-made) |
| Model | LS-V |
| Pricing | Upon Request |
| Brand | LISICO |
|---|---|
| Model Series | SRV / SRD / DVP / DVM |
| Measurement Principle | Torsional Resonance (Viscosity & Density) |
| Viscosity Range | 0–3,000 mPa·s (cP), up to 50,000 mPa·s (cP) optional |
| Density Range | 0–1.5 g/mL, extended range available |
| Viscosity Accuracy | ±1% of reading or better (customizable) |
| Density Accuracy | ±0.01 g/mL standard, ±0.001 g/mL optional |
| Viscosity Resolution | 0.001 mPa·s (cP) |
| Density Resolution | 0.001 g/mL |
| Temperature Sensor | Pt1000 (Class B or AA), integrated |
| Operating Temp | −50 to +300 °C (model-dependent) |
| Pressure Rating | up to 207 MPa (30,000 psi) |
| Wetted Materials | 316L SS or Titanium Grade 5 |
| Enclosure Rating | IP68/IP69, Ex ia IIC T2–T6 |
| Response Time | <1 s |
| Sample Volume | 0.7 mL |
| Electrical Interface | M12 connector or fixed cable |
| Process Connection | 3/4″ NPT, sanitary clamp, 1″ NPT, or 1/4″ HP (9/16-18 UNF) |
| Brand | LS Instruments |
|---|---|
| Origin | Switzerland |
| Model | DWS RheoLab |
| Temperature Range | 5°C–100°C |
| Frequency Range | 0.1 Hz–10 MHz |
| Minimum Measurable Frequency | 0.1 Hz |
| Maximum Measurable Frequency | 10⁷ Hz |
| Sample Volume Requirement | ≥150 µL |
| Sample State | Liquid |
| Measurement Principle | Diffusing Wave Spectroscopy (DWS) |
| Compliance | Designed for GLP/GMP-aligned workflows |
| Software Platform | LS Instruments RheoSoft v5.x |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Model | MFR 2100 |
| Sample Volume Requirement | ≥100 µL |
| Frequency Range | 0–100 Hz |
| Gap Adjustment Range | 0.6–30 mm |
| Gap Resolution | 0.625 mm |
| Actuation Mode | Pseudo-Random Squeezing (Patented) |
| Data Acquisition | Real-Time Fourier Transform Analysis |
| Control | Fully Automated Computer-Controlled Gap & Sample Handling |
| Brand | MyiP |
|---|---|
| Origin | Shanghai, China |
| Model | DV-1 |
| Instrument Type | Benchtop Fixed Rotational Viscometer |
| Viscosity Range | 1–2×10⁶ mPa·s |
| Accuracy | ±2% (for Newtonian fluids) |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Spindles | LV#1, #2, #3, #4 |
| Operating Environment | Ambient temperature |
| Compliance | Conforms to GB/T 265 and JJG 1002 national standards for kinematic and dynamic viscosity measurement |
| Brand | MyiP |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | NDJ-1 |
| Instrument Type | Benchtop Rotational Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 1–1×10⁵ mPa·s |
| Accuracy | ±5% (for Newtonian fluids) |
| Rotors | No. 0 (optional), No. 1–4 |
| Rotational Speeds | 6, 12, 30, 60 rpm |
| Compliance | GB/T 265–1988 |
| Dimensions | 280 × 290 × 450 mm |
| Sample Temperature Control | External bath required (no integrated Peltier or heater) |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus DSR |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Angular Velocity | 10 nrad/s |
| Maximum Angular Velocity | 325 rad/s |
| Frequency Range | 1 µHz – 100 Hz |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.001 N – 50 N |
| Normal Force Response Time | <10 ms |
| Vertical Travel Speed | 0.1 µm/s – 35 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Torque Range (Rate/Stress Control) | 0.01 µNm – 200 mNm |
| Torque Range (Strain/Stress Control) | 0.05 µNm – 200 mNm |
| Fixture Identification | RFID-enabled Smart Recognition |
| Environmental Control Unit | Plug-and-Play with Auto-Detection |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus DSR-III |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Angular Velocity | 10 nrad/s |
| Maximum Angular Velocity | 200 rad/s |
| Frequency Range | 1 µHz – 100 Hz |
| Maximum Torque | 150 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.01 N – 20 N |
| Normal Force Response Time | <10 ms |
| Vertical Travel Speed | 0.1 µm/s – 20 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Torque Range (Rate/Stress Control) | 0.1 µNm – 150 mNm |
| Torque Range (Strain/Stress Control) | 0.1 µNm – 150 mNm |
| Fixture Identification | RFID-enabled Smart Recognition |
| Environmental Control Unit | Plug-and-Play with Auto-Detection |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus DSR+ |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid |
| Bearing Type | Air Bearing |
| Minimum Angular Velocity | 1 nrad/s |
| Maximum Angular Velocity | 500 rad/s |
| Frequency Range | 1 µHz – 150 Hz |
| Maximum Torque | 225 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.001 N – 50 N |
| Normal Force Response Time | <10 ms |
| Vertical Travel Speed | 0.1 µm/s – 35 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Control Modes | Rate, Stress, Strain |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus lab+ |
| Instrument Type | Rotational Rheometer |
| Sample State | Liquid |
| Bearing Type | Air Bearing |
| Minimum Angular Velocity | 10 nrad/s |
| Maximum Angular Velocity | 325 rad/s |
| Frequency Range | 1 µHz – 150 Hz |
| Maximum Torque | 200 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.001 N – 50 N |
| Normal Force Response Time | 10 ms |
| Vertical Travel Speed | 0.1 µm/s – 35 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Torque Range (Steady-State) | 0.01 µNm – 200 mNm |
| Torque Range (Oscillatory) | 0.005 µNm – 200 mNm |
| Fixture Identification | RFID-enabled Smart Recognition |
| Environmental Control Unit | Plug-and-Play with Auto-Detection |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus Prime Ultra+ |
| Instrument Type | Rotational Rheometer |
| Frequency Range | 1 µHz to 150 Hz |
| Temperature Control | Modular EasySwap™ Environmental Units |
| Normal Force Control | High-Sensitivity Electromagnetic Sensor |
| Vertical Travel & Gap Control | Precision Motorized Actuation |
| Compliance | ASTM D3835, ISO 6721-10, ISO 3219, USP <911>, FDA 21 CFR Part 11 (Software Mode), GLP/GMP Audit Trail Capable |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus pro+ |
| Instrument Type | Rotational Rheometer |
| Motor Bearing | Air Bearing |
| Minimum Angular Velocity | 1 nrad/s |
| Maximum Angular Velocity | 500 rad/s |
| Frequency Range | 1 µHz – 150 Hz |
| Maximum Torque | 225 mNm |
| Torque Resolution | 0.1 nNm |
| Normal Force Range | 0.001 N – 50 N |
| Normal Force Response Time | <10 ms |
| Vertical Travel Speed | 0.1 µm/s – 35 mm/s |
| Vertical Travel Distance | 230 mm |
| Gap Resolution | 0.1 µm |
| Motor Inertia | 12 µN·m·s² |
| Torque Range (Steady-State) | 0.005 µNm – 225 mNm |
| Torque Range (Oscillatory) | 0.001 µNm – 225 mNm |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus Rosand RH10 |
| Instrument Type | Capillary Rheometer |
| Sample State | Liquid |
| Minimum Extrusion Speed | 5 µm/min |
| Maximum Extrusion Speed | 1200 mm/min |
| Maximum Load | 100 kN |
| Die Diameter Range | 0.5–3 mm |
| Barrel Diameter (Standard) | 15 mm (Optional: 9.5, 12, 19, 24 mm) |
| Barrel Material | Nitrided Steel (Optional: Stainless Steel or Hastelloy) |
| Die Material | Tungsten Carbide |
| Speed Dynamic Range | 240,000:1 |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Model | Kinexus Rosand RH2000 |
| Instrument Type | Capillary Rheometer |
| Sample State | Liquid |
| Minimum Piston Speed | 10 µm/min |
| Maximum Piston Speed | 1200 mm/min |
| Maximum Load | 20 kN |
| Die Diameter Range | 0.5–3 mm |
| Barrel Diameter | 15 mm (standard), optional 9.5 / 12 / 19 / 24 mm |
| Barrel Material | Nitrided Steel (optional stainless steel or Hastelloy) |
| Die Material | Tungsten Carbide |
| Speed Dynamic Range | 240,000:1 |
| Compliance | ASTM D3835, ISO 11443, ISO 6721-6, USP <911> |
| Brand | Netzsch |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | Kinexus Rosand RH7 |
| Instrument Type | Capillary Rheometer |
| Minimum Extrusion Speed | 2.5 µm/min |
| Maximum Extrusion Speed | 600 mm/min |
| Maximum Load Capacity | 50 kN |
| Speed Dynamic Range | 240,000:1 |
| Standard Barrel Diameter | 15 mm (optional: 9.5, 12, 19, 24 mm) |
| Barrel Material | Nitrided Steel (optional: Stainless Steel or Hastelloy) |
| Die Material | Tungsten Carbide |
| Die Diameter Range | 0.5–3 mm |
| Optional Accessories | Nitrogen Purge System, Melt Strength Tester, Melt Draw-Down Fixture, Laser-Based Die Swell Measurement, Slit Dies, PVT Measurement Dies, Melt Cut-Off Knife |
| Brand | OFITE |
|---|---|
| Origin | USA |
| Model | 130-76-1-C |
| Instrument Type | High-Temperature Rotational Viscometer |
| Viscosity Range | 0.5–500,000,000 mPa·s |
| Fixed Speeds | 12 (600, 300, 200, 100, 60, 30, 20, 10, 6, 3, 2, 1 rpm) |
| Variable Speed Range | 0.006–1000 rpm |
| Speed Accuracy | ±0.001 rpm |
| Shear Rate Range | 0.01–1700 s⁻¹ |
| Heating Jacket | Stainless Steel, 150 W, Max Temp: 88 °C |
| Power Supply | 97–250 VAC, 200 W, 50/60 Hz |
| Dimensions | 44 × 38 × 24 cm |
| Weight | 8.6 kg |
| Interface | RS-232 (DB-9), Windows 2000 or later, min. 1024×768 resolution |
| Brand | Omnitek |
|---|---|
| Origin | Netherlands |
| Model | U-Visc Series |
| Instrument Type | Capillary Viscometer (Fixed-Station) |
| Viscosity Range | 0.15–25,000 mm²/s |
| Temperature Range | 15–150 °C |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy | ±0.01 °C |
| Heating Rate | 4 °C/min |
| Standards Compliance | ASTM D445, ASTM D446, ISO 3104, ISO 3105, GB/T 265, GB/T 30515, GB/T 11137 |
| Sample Volume | 8–16 mL |
| Autosampler Capacity | 32 positions (dual 16-position rotating carousel, one per capillary) |
| Timing Resolution | 0.001 s |
| Cleaning System | Dual-solvent (high-dissolving + high-volatility), corrosion-resistant fluidic path, vacuum-assisted waste evacuation |
| Environmental Control | Sealed autosampler chamber with negative-pressure waste collection |
| Brand | POWEREACH |
|---|---|
| Model | NDJ-1 |
| Type | Analog Rotational Viscometer |
| Portability | Benchtop (with integrated stand) |
| Operating Environment | Ambient temperature (10–35 °C) |
| Viscosity Range | 1–100,000 mPa·s |
| Rotors | Standard set includes #1–#4 |
| Speed Settings | 6, 12, 30, 60 rpm |
| Accuracy | ±5% for Newtonian fluids |
| Power Supply | 220 V ±10%, 50 Hz |
| Net Weight | 1.5 kg |
| Dimensions (W×D×H) | 400 × 370 × 150 mm |
| Compliance | Designed per GB/T 2794–2013 (Chinese national standard for viscometer calibration), compatible with ISO 2555 and ASTM D2196 test methodologies |
| Brand | POWEREACH |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-4 |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Accuracy | ±5% (for Newtonian fluids) |
| Power Supply | 220 V ±10%, 50 Hz |
| Net Weight | 1.5 kg |
| Dimensions | 320 × 260 × 170 mm |
| Included Rotors | #1, #2, #3, #4 |
| Compliance | Designed for GLP-compliant routine viscosity monitoring in QC/QA and R&D environments |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Model | NDJ-5S |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–100,000 mPa·s |
| Rotors | Standard #1–#4 |
| Speed Settings | 6, 12, 30, 60 rpm |
| Accuracy | ±2% for Newtonian liquids |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Temperature | 5–35 °C |
| Relative Humidity | ≤80% |
| Dimensions | 370 × 325 × 280 mm |
| Net Weight | 6.8 kg |
| Compliance | Designed for GLP-compliant routine QC environments |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Portable Rotational Viscometer |
| Viscosity Range | 1–1,000,000 mPa·s |
| Rotational Speeds | 7.5 / 75 / 750 rpm |
| Accuracy | ±4% (for Newtonian fluids) |
| Dimensions (L×W×H) | 170 × 140 × 440 mm |
| Weight | 14 kg |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Compliance | Designed for routine QC and R&D in industrial and academic labs per ISO 2555 and ASTM D2196 principles |
| Brand | POWEREACH (Shanghai Zhongchen) |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop Rotational Viscometer |
| Viscosity Range | 1–2,000,000 mPa·s |
| Spindle Set | Standard #1–#4 spindles (optional #0 spindle for down to 0.1 mPa·s) |
| Speed Settings | 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm |
| Accuracy | ±2% for Newtonian fluids |
| Display | Backlit LCD with real-time spindle/speed/viscosity/% full-scale readout |
| Power Supply | AC 220 V ±10%, 50 Hz ±10% |
| Operating Environment | 5–35 °C, ≤80% RH |
| Dimensions | 370 × 325 × 280 mm |
| Net Weight | 6.8 kg |
| Brand | RheoSense |
|---|---|
| Origin | USA |
| Model | Initium |
| Instrument Type | Portable Microfluidic Viscometer |
| Viscosity Range | 0.2–2000 cP |
| Temperature Range | 4–70 °C |
| Sample Volume per Measurement | <5 µL |
| Shear Rate Range | Up to 10⁶ s⁻¹ |
| Compliance | ASTM D2196, ISO 2555, USP <911> |
| Brand | SBS |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | Auto-Falling Needle |
| Instrument Type | Benchtop Fixed-Position Viscometer |
| Operating Environment | Ambient Temperature |
| Viscosity Range | 0.5–1,000,000 cP |
| Measurement Principle | Gravitational Sedimentation of Calibrated Needle in Fluid |
| Shear Rate Range | 10⁻⁴–10³ s⁻¹ |
| Temperature Range | −40 to +150 °C |
| Sample Volume Options | 2.3, 3.6, 7.2, 9.6, 19.2, or 120 cm³ |
| Needle Materials | Borosilicate Glass, Fused Quartz, or Stainless Steel |
| Standard Needle Length | 10.2 cm (compact version: 4.2 cm) |
| Needle Density Options | 1.01, 1.1, 1.5, 2.0, 3.0, 5.0, and 8.0 g/cm³ |
| Timing Resolution | 0.01 s (optional 0.001 s) |
| Interface | RS-232 Serial Port |
| Accuracy & Repeatability | < ±1% |
| Compliance | ASTM D1545, ISO 12058-1, USP <911>, GLP-Compatible Data Logging |
| Brand | SBS |
|---|---|
| Origin | USA |
| Instrument Type | Portable Falling-Pin Viscometer |
| Sample Tube | Disposable 4.5 mL glass tube |
| Measurement Principle | Gravitational falling-pin (Stokes’ law-based) |
| Viscosity Range | 1–10⁸ cP |
| Temperature Control Range | 0–100 °C |
| Timing Resolution | 0.001 s |
| Pin Density Range | 6–300 g/cm³ |
| Accuracy & Repeatability | <1% |
| Interface | RS232 |
| Compliance | ASTM D1200, ISO 2555, USP <911> (for kinematic viscosity correlation) |