Sample Prep/Digestion Equipment
Filter
Showing 151–180 of 258 results
| Brand | KJ GROUP |
|---|---|
| Origin | Liaoning, China |
| Model | UNIPOL-1200M |
| Dimensions (L×W×D) | 660 mm × 460 mm × 720 mm |
| Number of Grinding/Polishing Plates | 1 |
| Plate Diameter | 300 mm |
| Platen Speed | 50–500 rpm |
| Carrier Head Speed | 1–60 rpm |
| Applied Pressure Range | 0.15–0.4 MPa |
| Power Supply | AC 220 V, 50 Hz, 450 W |
| Weight | 80 kg |
| Standard Carrier Plate Diameter | Ø150 mm |
| Standard Specimen Holders | Ø25 mm (optional: Ø22/Ø30/Ø45 mm) |
| Brand | KYKY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SBC-12 |
| Target Materials | Au, Ag, Pt, Cr, Ti, Cu, Ni, Au-Pd alloy |
| Target Diameter & Thickness | Φ58 mm × 0.12 mm |
| Control Method | Manual |
| Chamber Dimensions | Φ40 mm × 130 mm (sample compartment) |
| Stage Diameter | Φ40 mm (standard), optional Φ60 mm stage |
| Sputtering Gas | Air or Argon |
| Vacuum System | Two-stage direct-coupled rotary vane pump |
| Vacuum Gauge | Pirani gauge |
| Safety Feature | Micro-flow gas inlet valve for ion current regulation |
| Chamber Viewport | Reinforced borosilicate glass with optimized sealing |
| Brand | KYKY |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | SBC-16 |
| Target Material (Standard) | Au (57 mm diameter × 0.1 mm thickness) |
| Optional Targets | Pt, Au/Pd, Pt/Pd |
| Control System | Microprocessor-based timer (1–999 s), automatic pump-down, sputtering, and venting sequence |
| Chamber Dimensions | Stainless steel, Ø120 mm × H75 mm |
| Viewport Dimensions | Ø120 mm × H45 mm |
| Sample Stage | Standard rotary stage (Ø40 mm), accommodates 4 standard SEM stubs |
| Sputtering Gas | Argon (recommended) or dry air |
| Operating Pressure Range | Atmospheric to 1×10⁻³ mbar |
| Ultimate Vacuum | ≤1×10⁻⁴ mbar |
| Pumping Speed | 133 L/min |
| Sputtering Current | 5–30 mA (digitally regulated, pressure-independent) |
| Acoustic Noise Level | ≤56 dB(A) |
| Brand | Labo (Tianjin Labo / LABA) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | QLABPro |
| Price Range | USD $26,000–$39,000 (FOB) |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 12 or 20 vessels |
| Microwave Source | Magnetron |
| Max Temperature | 230 °C (standard mode) / 400 °C (high-temp mode) |
| Max Pressure | 500 psi |
| Exhaust Flow Rate | 150 CFM |
| Output Power | Up to 1200 W |
| Safety Features | Spring-loaded interlocked door, overpressure venting, real-time per-vessel T/P monitoring, thermal runaway detection, PTFE-coated cavity |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Product Line | ED and EHD Series |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Semi-Automatic |
| Sample Capacity | Up to 77 positions |
| Maximum Sample Mass | ≥5 g per vessel |
| Heating Technology | Surround-Heating Graphite Block with PID-Controlled Temperature Regulation |
| Thermal Uniformity | ≤±1.5 °C across block surface |
| Construction | Fully Corrosion-Resistant Enclosure with High-Temperature Anti-Corrosion Coated Graphite Surface |
| Insulation Material | Imported High-Efficiency Thermal Insulation |
| Energy Efficiency | Optimized thermal retention yielding 2–5× faster digestion vs. conventional hot plates |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | S16/S36 |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Semi-Automatic |
| Digestion Positions | Configurable (16 or 36) |
| Max Operating Temperature | Up to 220 °C |
| Temperature Control Accuracy | ±0.5 °C @ 100 °C |
| Heating Principle | Uniform Surround-Heating with PID Feedback Control |
| Reagent Channel | Single-tube open-vessel configuration (no integrated reagent dispensing) |
| Safety Features | Dual-stage thermal alarm (visual + audible), 50 °C surface overheat indicator, acid-resistant sealed chassis, optional external solution temperature probe |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | EG Series |
| Heating Power | 1000 W |
| Controller | Microcomputer-based Intelligent PID Controller |
| Max. Operating Temperature | 300 °C |
| Temperature Uniformity | ±2 °C (at steady-state setpoint) |
| Display | LCD Digital Display |
| Heating Surface Dimensions | 600 × 400 mm |
| Construction | Sealed Electronics with Multi-layer Corrosion Protection |
| Panel Options | Stainless Steel / PTFE-Coated / High-Temperature Acid-Resistant Coating |
| Brand | LabTech |
|---|---|
| Model | VB15 |
| Origin | Beijing, China |
| Equipment Type | Microwave-Assisted Digestion & Post-Digestion Acid Evaporation System |
| Cavity Rating | Industrial-Grade |
| Application Scope | Sample preparation for AA, ICP-MS, ICP-AES, and other elemental analysis techniques |
| Temperature Uniformity | ≤ ±1 °C at 100 °C |
| Energy Efficiency | >50% reduction vs. conventional hotplate evaporation |
| Throughput Advantage | 2–5× faster acid removal vs. traditional methods |
| Control Mode | Programmable timer-based operation |
| Compliance Context | Designed to support GLP-compliant sample prep workflows in environmental, food, pharmaceutical, and clinical laboratories |
| Brand | LabTech |
|---|---|
| Origin | Beijing, China |
| Model | VB77 |
| Instrument Type | Electric Heating Digestion System |
| Automation Level | Semi-Automatic |
| Sample Capacity | 77 positions |
| Tube Format | 16 mm OD borosilicate glass test tubes |
| Heating Method | Surround-type (360° circumferential) resistive heating |
| Temperature Range | Ambient to 180 °C (adjustable in 1 °C increments) |
| Temperature Uniformity | ≤ ±1 °C between wells at 100 °C |
| Temperature Control | Intelligent PID algorithm with real-time feedback and dual-sensor monitoring |
| Timing Function | Programmable timer (1 min – 99 h 59 min) |
| Compliance | Designed to meet WS/T 107.1–2016, GB/T 5750.5–2006, and ASTM D1252 for COD digestion |
| Brand | Leica Biosystems |
|---|---|
| Origin | Germany |
| Model | CM1520 |
| Maximum Sample Size | 55 mm × 55 mm or 50 mm × 80 mm |
| Section Thickness Range | 2 µm to 60 µm |
| Sectioning Increment | 25 µm + 3 µm step adjustment |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | CM1860UV |
| Type | Motorized Cryostat with UVC Disinfection & AgProtect™ Antimicrobial Coating |
| Chamber Temperature Range | –35 °C to –25 °C (adjustable) |
| Section Thickness Range | 0.5–100 µm |
| UVC Lamp Wavelength | 254 nm |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | EM RES102 |
| Maximum Sample Size | Ø 25 mm × 12 mm |
| Tilting Angle Range | –90° to +90° (dependent on sample holder) |
| Ion Beam Energy | 0.8 keV to 10 keV (adjustable in 0.1 keV increments) |
| Brand | Leica |
|---|---|
| Origin | Germany |
| Model | HistoCore Arcadia |
| Operating Temperature Range | 50–75 °C (1 °C increments) |
| Wax Bath Capacity | Up to 4 L |
| Tray Compatibility | ~150 cassettes (Peloris-compatible cassette baskets) |
| Display | 5.7-inch capacitive touchscreen LCD |
| Illumination | White LED |
| Power Supply | 100–120 VAC / 220–240 VAC, 50/60 Hz |
| Max Power Consumption | 1000 VA |
| Ambient Operating Temperature | +20 °C to +30 °C |
| Dimensions (D×W×H) | 636 × 560 × 384 mm |
| Weight | 27 kg |
| Optional Accessories | Ergonomic magnifier, liquid filtration module, footswitch |
| Cold Plate Function | Auto-regulated at −6 °C |
| Minimum Solidification Load | 65 paraffin blocks in 30 minutes |
| Cold Plate Dimensions | 155 × 80 × 100 mm |
| Cold Plate Weight | ~1.5 kg |
| Cold Plate Ambient Range | +15 °C to +40 °C |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | RM2265 |
| Pricing | Available Upon Request |
| Brand | Leici |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | KDNX-20 |
| Quotation | Upon Request |
| Temperature Control Range | Room Temperature +5 °C to 450 °C |
| Temperature Accuracy | ±1 °C |
| Digestion Vessel Capacity | 280 mL (water volume at 20 °C) |
| Sample Throughput | 20 samples per run |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Dimensions (W×D×H) | 515 mm × 421 mm × 211 mm |
| Weight | 25 kg |
| Brand | LICHEN |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region | Domestic (China) |
| Model | KDF Series |
| Price Range | USD 410 – 1,120 |
| Power Input | AC 220 V / 50 Hz |
| Heating Method | Infrared Quartz Tube |
| Temperature Range | RT to 530 °C |
| Temperature Control Accuracy | ±1 °C (PID models) |
| Available Configurations | 4-, 8-, 12-, and 20-position |
| Digestion Tube Capacity | 300 mL |
| Cooling Rack Design | Integrated (4/8-hole), Modular (12/20-hole) |
| Construction | Stainless Steel Work Surface & Base Plate, Fluorosilicone Seals, Bakelite Handles |
| Safety Features | Exhaust Collection Tube with Water-Aspirated Venting |
| Compliance | Designed for ISO 5983, AOAC 984.13, and ASTM D5142-compliant Kjeldahl sample preparation |
| Origin | Netherlands |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | MARCH AP-1000 |
| RF Frequency | 13.56 MHz (RF Generator with Auto-Impedance Matching) |
| Power Output | 2 kW |
| Chamber Material | Anodized Aluminum Alloy |
| Chamber Volume | Configurable (Standard & HTP Options Available) |
| Process Gases | O₂, Ar, H₂, He (via 4 Mass Flow Controllers) |
| Control System | PLC-Based Closed-Loop Control with Integrated Mechanical Height Sensor |
| Dimensions (Standard Unit) | 567 × 764 × 664 mm (W × D × H) |
| Dimensions (HTP Configuration) | 680 × 1127 × 1536–1890 mm (W × D × H) |
| Net Weight | 485 kg |
| Compliance | Designed for ISO Class 5–7 cleanroom integration |
| Software | Proprietary SPC-Enabled Process Management Suite with Audit Trail Capability |
| Brand | MICHEM |
|---|---|
| Model | RC-15 / RC-24 / RC-40 / RC-54 |
| Heating Material | High-Purity Graphite with Multi-Layer PTFE Coating |
| Max. Temperature | 460 °C |
| Temperature Accuracy | ±1.0 °C |
| Heating Uniformity | ±2.0 °C across block |
| Control System | PID Digital Controller with 30-Step Programmable Ramp/Soak |
| Sample Capacity | 15 × 100 mL, 24 × 50 mL, 40 × 100 mL, or 54 × 50 mL |
| Power Rating | 1200 W (RC-15/RC-24) / 3000 W (RC-40/RC-54) |
| Input Voltage | AC 220 V, 50 Hz, 16 A |
| Dimensions (W×H×D) | 470×350×270 mm (RC-15/RC-24) / 670×460×270 mm (RC-40/RC-54) |
| Compliance | Designed for GLP-compliant sample preparation workflows |
| Brand | Binzhenghong |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | Milestone 12- and 41-Position Configurations |
| Cavity Class | Industrial-Grade |
| Sample Capacity | 40 samples per run |
| Microwave Source | Single Magnetron |
| Max Temperature | 230 °C |
| Max Pressure | 1500 psi |
| Brand | Binzhenghong (Nanjing) |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | OEM/ODM Producer |
| Country of Origin | China |
| Model | ZH-44 |
| Pricing | Available Upon Request |
| Vessel Configuration | TFM Body + PFA Cap + Internal TFM Insert |
| Compatibility | Fully Interchangeable with Original Milestone UltraWAVE and ETHOS UP Systems |
| Brand | MKN |
|---|---|
| Model | DB-IVC |
| Power Supply | AC 220 V, 50 Hz |
| Temperature Range | RT–300 °C |
| Temperature Accuracy | ±1 °C |
| Heating Power | 2000 W |
| Working Surface Dimensions | 40 × 30 cm |
| Material | Thickened 304 Stainless Steel |
| Heating Technology | Far-Infrared Silicon Carbide Embedded in Aluminum Cast Base |
| Compliance | CE-marked design principles (IEC 61000-6-3, IEC 61000-6-2), GLP-aligned operational traceability support |
| Brand | MTI Corporation (formerly Hefei Kejing) |
|---|---|
| Model | MSK-MR100DC |
| Roller Diameter × Length | Φ100 mm × 100 mm |
| Roller Surface Hardness | RC > 62 (Chromium-plated carbon steel) |
| Gap Adjustment Range | 0–1.8 mm (micrometer-verified) |
| Linear Speed | 5–40 mm/s (continuously adjustable via potentiometer) |
| Drive Motor | 24 V DC, high-torque, max. current 1.8 A, rated power 40 W |
| Input Power | 110–220 V AC, 50/60 Hz |
| Dimensions (L×W×H) | 430 × 175 × 290 mm |
| Weight | Approx. 18 kg |
| Compliance | CE, UL/CSA-certified external power supply |
| Max. Sample Hardness | ≤50 HRC |
| Min. Final Thickness (typical) | 0.04 mm (graphite-coated Cu foil), 0.09 mm (LiFePO₄-coated Al foil) |
| Brand | NAI Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | NAI-WB24 |
| Price Range | USD 21,000 – 28,000 |
| Cavity Class | Industrial Grade |
| Sample Capacity | 24 vessels (standard configuration) |
| Microwave Source | Dual Magnetron |
| Max Operating Temperature | 300 °C |
| Temp. Measurement Accuracy | ±1 °C |
| Temp. Control Stability | ±1 °C |
| Temp. Uniformity Across Cavity | ±1 °C |
| Max Operating Pressure | 1500 psi |
| Cavity Volume | 66 L |
| Power Output | 0–2200 W (continuously variable) |
| Control System | Siemens PLC with 8-inch TFT-LED touchscreen (800×480) |
| Vessel Material | TFM-modified PTFE inner vessel + PEEK reinforced safety sleeves |
| Vessel Volume | 70 mL (standard), optional 100 mL |
| Cooling | Integrated acid-resistant forced-air ventilation with internal cavity air circulation |
| Safety | Self-locking buffered anti-explosion door with multi-point mechanical interlock and real-time pressure/temperature dual monitoring |
| Brand | NIL |
|---|---|
| Origin | Denmark |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | NIL-4i |
| Pricing | Contact for Quotation |
| Wafer Size | 4 in |
| Imprintable Area | 2 in diameter |
| Imprint Pressure Range | 0–25 PSI (upgradable to 100 PSI) |
| Mold Substrate Dimensions | 5 × 0.090 in |
| Typical Throughput | < 5 min/wafer |
| Controller Platform Dimensions | 5.8 × 16.5 × 12 in |
| Main Platform Dimensions | 17 × 16 × 15 in |
| Weight (Controller) | 18.5 lb |
| Weight (Main Unit) | 45 lb |
| Operating Temperature | 10–35 °C |
| Relative Humidity | ≤65% RH |
| Compressed Air Supply | Filtered, 70–100 PSI |
| Vacuum Source | ≤−14 PSI |
| Power Input | 110–220 VAC, 2 A, 50/60 Hz |
| Cleanroom Class | ISO Class 6 (Class 1000) or better |
| Brand | NOSELAB ATS |
|---|---|
| Origin | Italy |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PNEUMATIC DIE CUTTER |
| Instrument Type | Semi-Automatic Pellet Press |
| Maximum Applied Force | 55 kN |
| Operating Pressure Range | 0–6 bar |
| Max. Sample Thickness | 16 mm |
| Max. Distance Between Die Holder and Worktable | 70 mm |
| Punch Stroke | 18 mm |
| Adjustable Ram Stroke | 30 mm |
| Platen Dimensions | 320 × 200 mm |
| Safety | Dual-Hand Operated Start + Polycarbonate Safety Guard |
| Die Features | Spring-Loaded Ejector Integrated |
| Compliance | ISO 178, ASTM D638, ISO 527, ISO 1856 |
| Brand | PARR |
|---|---|
| Model | Parr Acid Digestion Bomb |
| Construction | Stainless Steel Body with PTFE (Teflon) Liner |
| Max Operating Temperature | 250 °C |
| Max Operating Pressure | 1800–5000 psig |
| Sample Volume Capacity | 23–125 mL |
| Application | Closed-Vessel Acid Digestion for Trace Element Analysis |
| Compliance | Designed for ASTM D5174, EPA Method 3050B/3051A/3052, ISO 11466, and USP <231> sample preparation workflows |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | Microwave Digestion Vessel |
| Pricing | Upon Request |
| Max Operating Temperature | 250 °C |
| Max Operating Pressure | 1200 psig |
| Sample Volume Capacity | 23–45 mL |
| Construction | Reinforced High-Performance Polymer Outer Sleeve with PTFE Liner |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SKD-08S |
| Pricing | Upon Request |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-08S2 |
| Heating Element Type | Opal White Quartz Tube with Embedded Resistive Heating Alloy |
| Radiation Spectrum | Predominantly Far-Infrared (λ = 3–10 µm) |
| Max Operating Temperature | 550 °C (Continuous), 600 °C (Short-Term) |
| Temperature Control Accuracy | ±2 °C |
| Ramp Rate | Programmable, 0.1–20 °C/min |
| Sample Capacity | 8 × 16 mm or 8 × 20 mm Digestion Tubes |
| Power Supply | 220 V AC, 50/60 Hz |
| Safety Compliance | IEC 61010-1, GB/T 12804-2022 |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | SKD-08S3 |
| Pricing | Available Upon Request |
| Control Interface | LCD Display with Timer + Multi-Stage Programmable Ramp |
| Heating Method | Infrared Radiation via Quartz Tube |
| Number of Digestion Ports | 8 |
| Temperature Range | Ambient to 680 °C |
| Preheating Time to 400 °C | ≤15 min |
| Temperature Stability | ±1 °C |
| Insulation | Dual-Layer (Ceramic Fiber + Air Gap) |
| Input Voltage | AC 220 V |
| Rated Power | 1.6 kW |
| Digestion Tube Dimensions & Material | 300 mm × 42 mm OD, High-Purity Fused Quartz |