| Brand | SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Hybrid Triple Quadrupole / Linear Ion Trap Mass Spectrometer |
| Model | QTRAP 4000 |
| Application Domain | LC-MS/MS Quantitation & Structural Characterization |
| Operational Age | 3–4 years in active service |
| Total Service Life | ~7 years |
| Warranty | 6 months limited hardware warranty |
| Regulatory Compliance | Designed to support GLP/GMP workflows, 21 CFR Part 11–ready software environment (with optional audit trail configuration) |
| Sample Introduction | Compatible with multiple HPLC/UHPLC platforms (Agilent, Shimadzu, Waters, Thermo) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2010 Plus |
| Mass Range | m/z 10–1090 |
| Scan Speed | 10,000 amu/sec |
| Vacuum System | Dual-inlet turbo molecular pump (≥360 L/s) |
| Ion Source | Shielded design with uniform temperature distribution |
| Detection Mode | Scan/SIM simultaneous acquisition via FASST |
| Mass Analyzer | Molybdenum quadrupole with pre-rod |
| Retention Time Correction | AART (Automatic Adjustment of Retention Time) |
| Software | Compound Composer, Method Package, EPA-compliant modules, GPC-GC/MS integration capability (Prep-Q system) |
| Warranty | 1 year |
| Instrument Age | 3–5 years |
| Compliance | Designed for GLP/GMP environments |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-TQ8050 |
| Year of Manufacture | 2018 |
| Condition | Refurbished & Certified Pre-Owned |
| Configuration | Complete Benchtop System with GC, TQMS, Autosampler, and GCMS Insight Software |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Orbitrap Fusion Lumos |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Orbitrap Fusion Tribrid High-Resolution Mass Spectrometer |
| Price | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | XSeries II ICP-MS (Refurbished) |
| Mass Range | 2–260 amu |
| Sensitivity (Li-7) | 50 Mcps/ppm |
| Sensitivity (Y-89) | 60 Mcps/ppm (XSeries II standard configuration) |
| Sensitivity (Tl-205) | 80 Mcps/ppm |
| Detection Limit (Be-9) | 0.5 ppt |
| Detection Limit (In-115, Bi-209) | 0.1 ppt |
| Oxide Ratio (CeO+/Ce+) | ≤1.5% |
| Doubly Charged Ion Ratio (Ce2+/Ce+) | ≤3.0% |
| Isotopic Ratio Precision (107Ag/109Ag) | RSD ≤0.1% |
| Abundance Sensitivity (low-mass) | 5 × 10⁻⁷ |
| Abundance Sensitivity (high-mass) | 1 × 10⁻⁷ |
| Collision Cell | ORS3™ (He-only mode) |
| High Matrix Tolerance | Up to 3% total dissolved solids (TDS) via HMI technology |
| Software Platform | MassHunter Workstation (QA/QC, audit trail, automated method execution) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | UltiMate 3000 |
| Instrument Type | Liquid Chromatograph (UHPLC) |
| Maximum Pressure | 620 bar |
| UV Detector Wavelength Range | 190–900 nm |
| UV Noise | < ±2.5 µAU |
| UV Drift | < 0.1 mAU/h |
| Fluorescence Excitation/Emission Range | 200–900 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Autosampler Carryover | < 0.005% |
| Injection Cycle Time | 15 s |
| Column Oven Temperature Range | 5–85 °C |
| Temperature Stability | < ±0.1 °C |
| Solvent Channels | 6 |
| Degasser | Integrated Online Vacuum Degasser |
| Pump Configuration | Dual Triple-Quaternary Gradient System |
| Software | Chromeleon CDS (7.x or later) |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | 1200L |
| Mass Range | 10–1500 u |
| Scan Rate | 500–6000 u/s |
| ESI SIM Sensitivity | 10 pg reserpine, S/N > 50:1 |
| ESI MS/MS Sensitivity | 10 pg reserpine, S/N > 50:1 |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Configuration | Triple quadrupole LC-MS/MS system with ProStar 210 dual LC pumps, ProStar 500 column valve module, Rainin CH-1 column heater, ProStar 410 autosampler, ProStar 330 PDA or 345 UV-Vis detector, rotary vacuum pump, dedicated P4 PC with Varian 1200/1200L MS workstation software and documentation |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | e-SAT/IN |
| Condition | Refurbished & Fully Tested |
| Regulatory Status | CE-marked, Compliant with IEC 61000-6-3 EMI Standards |
| Interface | RS-232 / TTL-compatible digital output |
| Input Range | ±10 V analog input, 12-bit resolution |
| Sampling Rate | Up to 1 kHz (typical in legacy HPLC system integration) |
| Power Supply | +5 V DC (supplied via host chromatograph interface) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Waters SQD |
| Mass Range | m/z 50–1000 |
| Ionization Sources | ESI and APCI |
| Detection Modes | Full Scan, SIM, SIR |
| Software | MassLynx v4.2 or later |
| Dynamic Range | 10⁶–10⁷ |
| Compliance | Designed for GLP/GMP environments |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Mass Range | m/z 10–2000 |
| Ionization Sources | ESI & APCI |
| Scan Modes | Full Scan, SIM, MRM |
| MRM Acquisition Rate | Up to 1000 transitions/sec |
| Dynamic Range | 10⁶–10⁷ |
| Detection Limit | Low pmol/L (ESI-MRM) |
| Software | MassLynx v4.2 or later |
| Compliance | Designed for GLP/GMP environments |
| Typical Service Life | 3–5 years (verified operational history, full service logs available upon request) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | TQD |
| Mass Range | m/z 10–2000 |
| Ionization Sources | ESI & APCI |
| Scan Modes | Full Scan, SIM, MRM |
| MRM Transition Rate | Up to 1000 transitions/sec |
| Dynamic Range | 10⁶–10⁷ |
| Detection Limit | Low pmol/L (ESI) |
| Software | MassLynx v4.2 or later |
| Compliance | ASTM D7598, USP <1225>, FDA 21 CFR Part 11 (with audit trail enabled) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UPLC + Xevo TQD |
| Price Range | USD $26,000 – $39,000 (FOB) |
| Operational Age | 3–5 years |