| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7650A (50-position, G4567A) |
| Sample Capacity | 50 vials (3-tier configuration supported) |
| Maximum Injection Volume | 250 µL |
| Compatible Systems | Agilent 6890N GC, 7890/8890 GC, and 5975/5977 GC-MS platforms |
| Needle Options | Supports 250 µL and 500 µL syringes |
| Injection Modes | Single-injection, multi-injection, priority-sample injection, overlapping sequence execution |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7693A 16-Position Autosampler (G4513A) |
| Sample Capacity | 16 × 2-mL vials (expandable to 150 vials with optional tray modules) |
| Injection Volume Range | 0.1–50 µL (single injection, using 100-µL syringe) |
| Syringe Options | 100 µL (standard), 250 µL and 500 µL (with Enhanced Sample Handling module) |
| Sample Preparation Functions | Automated dilution, internal standard addition, heating (sample tray temperature range: ambient – 150 °C), mixing, solvent addition |
| Software Control | Agilent Easy SamplePrep for GC sample preparation method development and execution |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7693A |
| Part Number | G4514A |
| Capacity | 150 × 2-mL vials |
| Maximum Single Injection Volume | 50 µL (with 100-µL syringe) |
| Optional Syringes | 250 µL, 500 µL |
| Sample Preparation Functions | Dilution, Internal Standard Addition, Heating (sample tray), Mixing, Solvent Addition |
| Software | Easy SamplePrep |
| Compliance | Designed for integration with Agilent GC systems |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | 7697A (G4557A, 111-position) |
| Price | USD 16,800 (approx.) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7697A |
| Sample Capacity | Up to 111 vials (auto-sampler mode) |
| Vial Sizes Supported | 10 mL, 20 mL, 22 mL |
| Oven Temperature Range | Ambient to 200 °C |
| Transfer Line & Valve Temperature Range | Ambient to 200 °C |
| Injection Mode | Six-port valve with fixed-volume loop |
| Carrier Gas Control | Electronic Pressure Control (EPC) for He, N₂, H₂ |
| Software Compatibility | Agilent OpenLAB CDS and ChemStation |
| Compliance | Designed for GLP/GMP environments |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | G1888 (70-position) |
| Temperature Range | 40–230 °C |
| Sample Capacity | 70 vials |
| Heating Zones | 12 heated positions |
| Inert Flow Path | Standard deactivation from needle to transfer line |
| Compatibility | GC systems including Agilent 7890A and 6890N with inert volatile interface |
| MHE Modes | Concentration mode and multiple-puncture mode (up to 100 punctures per vial) |
| Software Control | GC ChemStation, MSD ChemStation (Enhanced & Security), Cerity NDS |
| Compliance Features | Supports audit trail, electronic signatures, and method validation workflows per FDA 21 CFR Part 11 and GLP/GMP requirements |
| Diagnostic Functions | Built-in power-on self-test, automated leak check, four preloaded chemical test methods |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | G3440A FPD (241, with Electronic Pressure Control) |
| Price | USD 4,800 (ex-works) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | G3440A NPD Detector Module (250 °C, with Electronic Pressure Control) |
| Temperature Range | Up to 250 °C |
| Detector Type | Thermionic Nitrogen-Phosphorus Detector (NPD) |
| Control Interface | Integrated Electronic Pressure Control (EPC) |
| Compliance | Designed for Agilent 6850/6890/7890 Series GC Systems |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Agilent VK7025 Dissolution Tester |
| Price Range | USD 1,400 – 4,200 (FOB) |
| Instrument Age | 4–5 years |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Instrument Type | Second-hand Dissolution Testing System |
| Model | VK7025 |
| Age | 4–5 years |
| Regulatory Compliance | USP <711>, EP 2.9.3, JP XVII, ChP 0931 |
| Sample Capacity | 6-vessel |
| Vessel Configurations | Basket (USP Apparatus 1) & Paddle (USP Apparatus 2) |
| Temperature Control | Independent vessel-level PT100 probes with ±0.2 °C accuracy |
| Automation Features | Motorized sampling arm, programmable DDM (Drug Delivery Module), TruCenter™ magnetic cup alignment, dome-shaped anti-evaporation lids |
| Software Compatibility | Agilent Dissolution Workstation (FDA 21 CFR Part 11 compliant with audit trail, electronic signature, and user access control) |
| Brand | Dionex |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | DX-120 |
| Instrument Age | >10 Years |
| Pump Flow Rate | 0.5–4.0 mL/min |
| Max Pump Pressure | 4000 psi (27.5 MPa) |
| Conductivity Detector Range | 0–1700 µS |
| Temperature Compensation | 1.5–1.9%/°C |
| Detector Cell Volume | 1.25 µL |
| Operating Temperature | 10–40°C |
| Dimensions (H×W×L) | 60 × 30 × 40 cm |
| Weight | ~40 kg |
| Power Input | 100 V/50 Hz, 115 V/60 Hz, or 220–240 V/50 Hz |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | HS-40 |
| Configuration | 40-sample carousel |
| Automation | Fully automated thermal equilibration, pressurization, sampling, and injection sequence |
| Interface | Universal GC/GC-MS compatible (standard 1/16" OD stainless steel transfer line with Swagelok fittings) |
| User Interface | Color LCD touchscreen with graphical workflow navigation |
| Safety Mechanism | Patented pressure-relief venting system integrated into sample vials |
| Optional Accessories | High-pressure sampling kit, backflush module, cryo-trap concentrator, orbital shaker module, zero-dead-volume (ZDV) liner for capillary inlet |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | HS-20 / HS-20LT / HS-20 TRAP (90-position) |
| Configuration | Quantitative Loop or Cold Trap Mode |
| Sample Capacity | 90 vials (20 mL standard) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Detector Types | Photodiode Array (PDA), Refractive Index (RID), Fluorescence (FLD) |
| Series Compatibility | LC-10AT/10AVP, LC-20AT/20AP |
| Condition | Factory-Refurbished with Full Functional Validation |
| Certification | ISO/IEC 17025–Aligned Calibration Report Available |
| Warranty | 12-month limited hardware warranty |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | e-SAT/IN |
| Condition | Refurbished & Fully Tested |
| Regulatory Status | CE-marked, Compliant with IEC 61000-6-3 EMI Standards |
| Interface | RS-232 / TTL-compatible digital output |
| Input Range | ±10 V analog input, 12-bit resolution |
| Sampling Rate | Up to 1 kHz (typical in legacy HPLC system integration) |
| Power Supply | +5 V DC (supplied via host chromatograph interface) |