| Brand | AnTing Feige |
|---|---|
| Origin | Shanghai, China |
| Instrument Type | Benchtop Centrifuge |
| Maximum Speed | 16500 rpm |
| Maximum RCF | 18080 ×g |
| Capacity | 12 × 1.5 mL / 2 mL tubes (angle rotor) |
| Dimensions | 350 × 390 × 350 mm (L × W × H) |
| Power Supply | 220 V, 50 Hz, 250 W |
| Timer Range | 0–60 min |
| Noise Level | ≤70 dB(A) |
| Safety | Electronic lid lock, microprocessor control, automatic rotor identification (via preset parameters), over-speed and imbalance protection |
| Brand | AnTing FeiGe |
|---|---|
| Origin | Shanghai, China |
| Model | TGL-16C |
| Type | Benchtop Centrifuge |
| Max Speed | 16000 rpm |
| Max RCF | 17000 ×g |
| Rotor Type | Fixed-Angle |
| Capacity | 7 mL × 8 (at 14000 rpm) or 1.5 mL × 12 (at 16000 rpm) |
| Timer Range | 0–60 min |
| Power Supply | 220 V, 50 Hz, 250 W |
| Dimensions | 230 × 285 × 265 mm (L×W×H) |
| Weight | 15 kg |
| Brand | AnTing FeiGe |
|---|---|
| Origin | Shanghai, China |
| Model | TGL-16G |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–16,000 rpm |
| Max RCF | 17,000 ×g |
| Rotor Configuration | Fixed-angle rotor |
| Capacity | 5 mL × 10 or 1.5 mL × 12 |
| Timer Range | 0–60 min |
| Power Supply | 220 V, 50 Hz, 250 W |
| Dimensions (L×W×H) | 330 × 300 × 300 mm |
| Weight | 15 kg |
| Compliance | CE-marked design principles, GLP-supportive operational architecture |
| Brand | AnTing Feige |
|---|---|
| Origin | Shanghai, China |
| Model | TGL-16GB |
| Max Speed | 12000 rpm |
| Max RCF | ≥12000 ×g |
| Capacity | 24 × 2 mL or 48 × 0.5 mL |
| Timer Range | 0–60 min |
| Noise Level | ≤70 dB(A) |
| Power Supply | 220 V, 50 Hz, 370 W |
| Dimensions (L×W×H) | 350 × 390 × 350 mm |
| Weight | 20 kg |
| Rotor Type | Fixed-angle rotor |
| Application Class | Biomolecular separation |
| Safety | Electronic door lock |
| Drive System | Frequency-controlled motor |
| Brand | AnTing Feige (Centifuge) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TGL-16GR |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm (High-Speed Class) |
| Function | Refrigerated Centrifuge |
| Configuration | Swing-Bucket & Fixed-Angle Rotor Compatible |
| Separation Grade | Biomolecular Applications |
| Max Capacity | 10 mL × 12 |
| Max Speed | 16,000 rpm |
| Max RCF | 15,455 ×g |
| Dimensions (L×W×H) | 500 mm × 540 mm × 780 mm |
| Weight | 72 kg |
| Temperature Range | −5 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Noise Level | <72 dB(A) |
| Power Supply | 220 V, 50 Hz, 1.5 kW |
| Brand | AnTing FeiGe |
|---|---|
| Origin | Shanghai, China |
| Model | TGL-18C |
| Max Speed | 18000 rpm |
| Max RCF | 21000 ×g |
| Max Capacity | 5 mL × 10 |
| Rotor Type | Fixed-Angle |
| Dimensions | 490 mm × 356 mm × 315 mm |
| Drive System | Inverter-Controlled Brushless Motor |
| Speed Range | 300–18000 rpm |
| Rotor Configurations | 1.5 mL × 12, 7 mL × 8 |
| Safety | Electronic Lid Lock, Rotor Recognition (via mechanical coding), Over-Speed & Imbalance Protection |
| Brand | AnTing Feige (Centifuge) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | TGL-18C |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 100–18,000 rpm |
| Max RCF | 21,000 × g |
| Max Capacity | 10 × 5 mL |
| Refrigeration | Yes (Active Cooling) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz |
| Power Consumption | 250 W |
| Temperature Rise During Operation | <6 °C |
| Speed Accuracy | ±50 rpm |
| Dimensions (W×D×H) | 350 × 450 × 310 mm |
| Net Weight | 22 kg |
| Rotor Type | Fixed-Angle (e.g., 12 × 1.5 mL or 8 × 7 mL) |
| Construction | 316 Stainless Steel Chamber |
| Drive System | Brushless Inverter Motor |
| Safety | Electronic Lid Lock, Auto-Balancing Dampers, Patented Hinge Mechanism |
| Brand | AnTing FeiGe |
|---|---|
| Origin | Shanghai, China |
| Model | TGL-20B |
| Max Speed | 20000 rpm |
| Max RCF | 24596 ×g |
| Capacity | 50 mL × 6 (with angle rotor) |
| Timer Range | 0–99 min |
| Noise Level | <70 dB(A) |
| Dimensions (L×W×H) | 500 mm × 540 mm × 570 mm |
| Weight | 47 kg |
| Power Supply | 220 V, 50 Hz |
| Motor Type | Frequency-Controlled Brushless DC Motor |
| Brand | AnTing FeiGe |
|---|---|
| Origin | Shanghai, China |
| Model | TGL-20B |
| Type | Benchtop Centrifuge |
| Max Speed | 20000 rpm |
| Max RCF | 24596 ×g |
| Max Capacity | 50 mL × 6 |
| Rotor Configurations | Angle rotors (1.5 mL × 12 @ 20000 rpm |
| Timer Range | 0–99 min |
| Noise Level | <70 dB(A) |
| Dimensions (L×W×H) | 500 × 540 × 570 mm |
| Weight | 47 kg |
| Power Supply | 220 V, 50 Hz |
| Brand | AnTing Feige |
|---|---|
| Origin | Shanghai, China |
| Model | TGL-20B |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm (Max. 20,000 rpm) |
| Max. RCF | 26,832 ×g |
| Max. Capacity | 6 × 100 mL |
| Dimensions | 500 × 540 × 570 mm |
| Drive System | AC Variable-Frequency Motor |
| Rotor Types | Fixed-angle (multiple configurations), Horizontal (microplate), Single-unit control with electronic safety lock |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | GL-12B |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 12,000 rpm |
| Max RCF | 9,338 × g |
| Capacity | 4 × 100 mL (angular rotor) |
| Temperature Range | −20 °C to +30 °C |
| Timer Range | 0–99 min |
| Power Consumption | 1.5 kW |
| Dimensions (L×W×H) | 600 × 505 × 770 mm |
| Weight | 115 kg |
| Rotor Type | Fixed-angle |
| Enclosure Material | Reinforced polymer housing |
| Safety | Electronic door interlock system |
| Compliance | Designed per IEC 61010-1 for laboratory equipment safety |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | GL-16G-II |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 16,000 rpm |
| Max RCF | 17,000 × g |
| Capacity | 12 × 10 mL (angular rotor) |
| Temperature Range | −20 °C to +30 °C |
| Timer Range | 0–99 min |
| Power Consumption | 1.5 kW |
| Dimensions (L×W×H) | 600 × 505 × 770 mm |
| Weight | 111 kg |
| Rotor Type | Fixed-angle |
| Safety | Electronic door lock |
| Construction | Reinforced polymer housing |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | GL-20B |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 20,000 rpm |
| Max RCF | 43,825 × g |
| Max Capacity | 6 × 500 mL |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz |
| Total Power | 3 kW |
| Dimensions (L×W×H) | 790 × 665 × 950 mm |
| Weight | 277 kg |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | GL-20G-II |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | Up to 20,000 rpm |
| Max RCF | 25,938 × g |
| Max Capacity | 6 × 50 mL |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz |
| Total Power | 1.5 kW |
| Dimensions (L×W×H) | 500 mm × 540 mm × 780 mm |
| Weight | 115 kg |
| Rotor Configuration | Fixed-angle rotor |
| Safety | Electronic door lock |
| Construction | Reinforced polymer housing |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | GL-21B |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | 0–21,000 rpm |
| Max RCF | 46,700 × g |
| Max Capacity | 6 × 500 mL |
| Temperature Range | −20 °C to +30 °C |
| Temp. Accuracy | ±2 °C |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz |
| Total Power | 3 kW |
| Dimensions (L×W×H) | 790 × 665 × 950 mm |
| Weight | 277 kg |
| Rotor Configuration | Fixed-angle rotor standard |
| Safety | Electronic door interlock system |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | KA-1000 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2220 × g |
| Rotor Capacity | 8 × 20 mL (angle rotor) |
| Timer Range | 0–30 min |
| Power Supply | 220 V, 50 Hz, 135 W |
| Dimensions (L×W×H) | 330 × 300 × 280 mm |
| Weight | 12 kg |
| Construction | Reinforced polymer housing with electronic safety lid lock |
| Compliance | Designed for general laboratory use under ISO/IEC 17025-aligned operational environments |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | KA-1000C |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2220 × g |
| Rotor Type | Fixed-angle rotor |
| Capacity | 8 × 15 mL |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 380 mm × 480 mm × 330 mm |
| Net Weight | 45 kg |
| Construction | Reinforced polymer housing with electronic safety interlock door |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | KA-1000D |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2220 ×g |
| Rotor Type | Fixed-Angle |
| Rotor Capacity | 15 mL × 8 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 520 × 375 × 335 mm |
| Weight | 45 kg |
| Construction | Reinforced polymer housing with electronic safety door lock |
| Control System | Frequency-converter motor with capacitive touch panel interface |
| Compliance | Designed for GLP-compliant routine separation tasks in academic and QC laboratories |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | LXJ-IIB |
| Type | Benchtop Refrigerated Centrifuge |
| Speed Range | 0–3600 rpm |
| Max RCF | 3040 ×g |
| Rotor Type | Swing-Bucket Horizontal Rotor |
| Max Capacity | 120 × 5 mL Vacuum Blood Tubes |
| Temperature Control | Refrigerated (operating range: 4–25 °C) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 750 W |
| Dimensions (L×W×H) | 550 mm × 700 mm × 770 mm |
| Net Weight | 144 kg |
| Drive System | Brushless Frequency-Controlled Motor |
| Safety Features | Electronic Door Interlock, Automatic Lid Lock During Operation |
| Noise Level | ≤65 dB(A) |
| Compliance | Designed for GLP-compliant clinical laboratories |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | LXJ-IIC |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 3000–5000 ×g |
| Max Capacity | 1000 mL × 4 (horizontal rotor) |
| Rotor Configurations | 500 mL × 6, 50 mL × 24, 15 mL × 42, 10 mL × 72, 7 mL × 72, 5 mL × 72, 6 mL × 210, 50 mL × 24, 15 mL × 54, 5 mL × 96, 192-well microplate |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 750 W |
| Dimensions (L×W×H) | 700 mm × 800 mm × 900 mm |
| Weight | 160 kg |
| Enclosure Material | Reinforced engineering plastic |
| Safety | Electronic door interlock system |
| Brand | Anting |
|---|---|
| Origin | Shanghai, China |
| Model | LXJ-IIZ |
| Type | Benchtop Centrifuge |
| Category | Low-Speed Centrifuge |
| Cooling | Refrigerated |
| Rotor Type | Horizontal Swing-Bucket Rotor |
| Maximum Capacity | 120 × 5 mL Vacuum Blood Tubes |
| Maximum Speed | 3600 rpm |
| Maximum RCF | 3040 × g |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 750 W |
| Dimensions (L×W×H) | 550 mm × 700 mm × 770 mm |
| Weight | 145 kg |
| Drive System | Brushless Frequency-Controlled Motor |
| Safety | Electronic Door Lock Interlock |
| Noise Level | Low-Noise Operation |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-36C |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–3600 rpm |
| Max RCF | 3100 × g |
| Rotor Configuration | Horizontal Swing-Out Rotor |
| Max Capacity | 4 × 1000 mL |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 750 W |
| Dimensions (L×W×H) | 715 × 550 × 435 mm |
| Weight | 90 kg |
| Safety | Electronic Lid Lock |
| Construction | Reinforced Polymer Housing |
| Compliance | Designed for GLP-compliant routine separation workflows |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-4 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 1430 × g |
| Rotor Capacity | 6 × 20 mL (angle rotor) |
| Timer Range | 0–30 min |
| Power Supply | 220 V, 50 Hz, 65 W |
| Dimensions (L×W×H) | 280 mm × 310 mm × 265 mm |
| Net Weight | 9 kg |
| Construction | Reinforced polymer housing with electronic safety door lock |
| Compliance | Designed for general laboratory separation per ISO 13485-aligned manufacturing practices |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-4000C |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 3300 × g |
| Max Capacity | 50 mL × 4 (horizontal rotor) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 660 mm × 460 mm × 415 mm |
| Weight | 80 kg |
| Rotor Configuration | Horizontal swing-out rotor with safety hood |
| Drive System | Frequency-controlled AC motor |
| Construction | Reinforced polymer housing with precision-machined aluminum rotor chamber |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-40B |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–5000 rpm |
| Max RCF | 4328 ×g |
| Rotor Capacity | 100 mL × 4 (swinging bucket), 50 mL × 8, or 15 mL × 16 (all at ≤4000 rpm) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 505 mm × 450 mm × 425 mm |
| Net Weight | 53 kg |
| Construction | Reinforced polymer housing with precision-machined rotor chamber |
| Safety | Electronic door interlock system |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-40C |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 3180 × g |
| Max Capacity | 100 mL × 4 (horizontal rotor) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 400 W |
| Dimensions (L×W×H) | 660 mm × 460 mm × 415 mm |
| Weight | 70 kg |
| Rotor Type | Swing-Bucket Horizontal Rotor |
| Construction | Reinforced polymer housing with precision-machined rotor chamber |
| Safety | Electronic door interlock system |
| Compliance | Designed to meet general laboratory safety and electromagnetic compatibility (EMC) requirements per IEC 61000-6-3/6-2 |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-4C |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 1430 × g |
| Rotor Capacity | 6 × 15 mL (angle rotor) |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 380 mm × 480 mm × 330 mm |
| Weight | 45 kg |
| Construction | Reinforced polymer housing with electronic safety door lock |
| Compliance | Designed for general laboratory use under ISO/IEC 17025-aligned workflows |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-4D |
| Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 1430 ×g |
| Rotor Type | Fixed-Angle |
| Rotor Capacity | 15 mL × 6 |
| Timer Range | 0–99 min |
| Power Supply | 220 V, 50 Hz, 180 W |
| Dimensions (L×W×H) | 520 × 375 × 335 mm |
| Weight | 45 kg |
| Construction | Reinforced polymer housing with electronic door interlock |
| Cooling | Ambient (non-refrigerated) |
| Control System | Microprocessor-based touch interface with variable-speed ramping |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-5-A |
| Type | Benchtop Centrifuge |
| Speed Range | 0–3600 rpm |
| Max RCF | 2680 × g |
| Rotor Type | Horizontal (Swinging-Bucket) |
| Capacity | 5 mL × 32 tubes |
| Timer Range | 0–99 min |
| Noise Level | <70 dB(A) |
| Power Supply | 220 V, 50 Hz, 400 VA |
| Dimensions (L×W×H) | 505 × 450 × 425 mm |
| Weight | 56 kg |
| Construction | Reinforced polymer housing with electronic lid interlock |
| Cooling | Non-refrigerated (ambient-temperature operation) |
| Brand | AnTing |
|---|---|
| Origin | Shanghai, China |
| Model | TDL-5-Z |
| Type | Benchtop Centrifuge |
| Speed Range | 0–3500 rpm |
| Max RCF | 2602 × g |
| Rotor Type | Horizontal (Swinging-Bucket) |
| Max Capacity | 56 × 2/5 mL vacuum blood tubes |
| Cap-Removal Function | Fully automatic, 100% cap removal rate |
| Timer Range | 0–99 min |
| Noise Level | <70 dB(A) |
| Power Supply | 220 V, 50 Hz, 400 VA |
| Dimensions (L×W×H) | 505 × 450 × 425 mm |
| Weight | 56 kg |
| Construction | High-strength engineering plastic housing |
| Safety | Electronic door lock, imbalance detection, auto-stop on lid open |