Separation/Extraction Equipment
Filter
Showing 301–330 of 1376 results
| Brand | CZGY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | LD-5 |
| Max Capacity | 6 × 50 mL |
| Max Speed | 4000 rpm |
| Dimensions | 290 × 330 × 260 mm |
| Power Supply | 220 V, 50 Hz |
| Motor Power | 80 W |
| RCF (Relative Centrifugal Force) | 2395 × g |
| Timing Control | Digital Timer |
| Display | Digital RPM Readout |
| Safety | Interlocked Transparent Lid |
| Compliance | CE-marked design principles (IEC 61010-1), GLP-ready operational protocol |
| Brand | CZGY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer | CZGY Instrument Co., Ltd. |
| Model | TGL-16 |
| Max Speed | 16000 rpm |
| Max RCF | 17000 × g |
| Capacity | 12 × 1.5 mL or 12 × 0.5 mL microtubes |
| Timer Range | 0–60 min |
| Power Supply | 220 V, 50 Hz, 250 W |
| Dimensions (W×D×H) | 290 × 330 × 260 mm |
| Weight | Approx. 18 kg |
| Rotor Material | Anodized Aluminum Alloy |
| Safety Certification | CE-compliant design per IEC 61010-2-020 (Centrifuges) |
| Brand | CZGY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YXJ-1 |
| Max Capacity | 6 × 20 mL |
| Max Speed | 4000 rpm |
| RCF (max) | 1960 × g |
| Timer Range | 0–60 min |
| Power Supply | 220 V, 50 Hz |
| Rated Power | 40 W |
| Dimensions | 235 × 280 × 240 mm |
| Weight | Lightweight benchtop design |
| Safety | Grounded operation, polycarbonate lid interlock, balanced load requirement (<3 g imbalance) |
| Brand | CZGY |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Direct Manufacturer |
| Model | YXJ-2 |
| Max. Speed | 16000 rpm |
| Max. RCF | 17000 × g |
| Capacity | 12 × 1.5 mL or 12 × 0.5 mL |
| Timer Range | 0–60 min |
| Power Supply | 220 V, 50 Hz, 250 W |
| Dimensions (W×D×H) | 290 × 330 × 260 mm |
| Weight | Approx. 12.5 kg |
| Noise Level | ≤65 dB(A) |
| Motor Type | Brushless DC Motor |
| Rotor Material | Anodized Aluminum Alloy |
| Safety Features | Dual-layer stainless steel protective housing, automatic rotor imbalance detection, lid interlock, overspeed protection |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | Daxluot-5CTL |
| Ultrasonic Power | 1800 W (continuously adjustable) |
| Frequency Range | 20–25 kHz |
| Heating Power | 1000 W |
| Temperature Range | −10 to 100 °C |
| Reactor Volume | 5000 mL |
| Stirring Power | 60 W |
| Stirring Speed | 10–1200 rpm |
| Ultrasonic Duty Cycle | 0.1–99.9% |
| Cooling Capacity | 500 W |
| Cooling Temperature Range | −5 °C to ambient |
| Power Supply | 220 V AC |
| Brand | Daxluot |
|---|---|
| Origin | Shanghai, China |
| Model | HJ911-8P |
| Ultrasonic Power | 4000 W (2 × 2000 W channels) |
| Frequency | 20 kHz ±1 kHz |
| Temperature Range | Ambient to 90 °C |
| Sample Capacity | 300 mL × 8 channels |
| Transducer Diameter | 12 mm × 8 |
| Control Interface | 7-inch color touchscreen + PLC-based dual-control system |
| Operation Modes | Pulsed or continuous ultrasonication |
| Safety Features | Overtemperature protection, fault alarm, password-protected program access, integrated acoustic shielding |
| Application Scope | Laboratory-scale and pilot-scale extraction, cell disruption, nano-dispersion, emulsification, and cleaning |
| Origin | Shanghai, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | Daxluot-4S |
| Price | USD 6,500 (FOB Shanghai) |
| Ultrasonic Output Power | 2000 W (adjustable) |
| Operating Frequency | 20 kHz |
| Sample Capacity | 4 × 300 mL vessels |
| Pulse Mode | 0.1–99.9 s on/off adjustable |
| Timer Range | 0–99 h 59 min 59 s |
| Temperature Monitoring & Overheat Protection | Ambient to 90 °C |
| Control Interface | 4.3-inch TFT capacitive touchscreen |
| Data Storage | 20 programmable protocols with user password protection |
| Power Supply | AC 220 V ±5%, 50 Hz (110 V option available) |
| Communication Interface | Optional RS-232 or USB-to-PC connectivity |
| Probe Material | Grade 5 titanium alloy (Ti-6Al-4V), corrosion-resistant, USP Class VI compliant |
| Amplitude Stability | Closed-loop amplitude regulation under variable load conditions |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | DLG-160AT |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm (Max. 16,000 rpm) |
| Max. RCF | 23,669 × g |
| Max. Capacity | 6 × 50 mL |
| Dimensions (L×W×H) | 330 mm × 420 mm × 280 mm |
| Noise Level | <65 dB(A) |
| Speed Accuracy | ±30 rpm |
| Timer Range | 1 s – 99 min |
| Power Supply | AC 220 V, 50 Hz, 5 A |
| Power Consumption | 750 W |
| Rotor Type | Fixed-angle |
| Safety Certifications | FDA Registered, GMP-compliant sealing (food-grade silicone rubber seal), CE-marked electrical safety |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | DLG-R165AT |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Cooling Function | Refrigerated |
| Rotor Type | Fixed-Angle |
| Maximum Capacity | 36 × 1.5 mL tubes |
| Maximum Speed | 16,500 rpm |
| Maximum RCF | 21,532 × g |
| Dimensions (L×W×H) | 280 mm × 540 mm × 300 mm |
| Speed Accuracy | ±30 rpm |
| Time Range | 1 min – 9 h 59 min (or 1–99 min in short-mode) |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz, 10 A |
| Sealing Material | Food-Grade Silicone Rubber Gasket |
| Safety Features | Electronic Door Lock, Lid Interlock, Overspeed Protection, Overtemperature Protection, Automatic Fault Alarm |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | DLT-HS165 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 10,000–30,000 rpm (Max. 16,500 rpm) |
| RCF Max | 23,669 × g |
| Max Capacity | 4 × 100 mL |
| Speed Accuracy | ±30 rpm |
| Timer Range | 1 min – 99 min 59 s |
| Display | LCD + Touch Panel Interface |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz, 10 A |
| Dimensions (L×W×H) | 330 mm × 420 mm × 280 mm |
| Net Weight | 20 kg |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | DLT-LS55 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–5500 rpm |
| Max RCF | 5310 × g |
| Max Capacity | 4 × 500 mL |
| Dimensions (L×W×H) | 460 mm × 540 mm × 340 mm |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz, 20 A |
| Net Weight | 31 kg |
| Speed Accuracy | ±30 rpm |
| Time Setting Range | 1 min – 99 h 59 min |
| Drive System | Microprocessor-Controlled AC Frequency Conversion Motor |
| Safety Features | Electronic Door Lock, Lid Interlock, Overspeed Protection, Automatic Fault Alarm |
| Acceleration/Deceleration Profiles | 10 Programmable Ramp Curves |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | DLT-RD50 |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Max Capacity | 15 mL × 32 |
| Max RCF | 4390 × g |
| Dimensions (L×W×H) | 460 mm × 710 mm × 420 mm |
| Weight | 80 kg |
| Max Speed | 5000 rpm |
| Speed Accuracy | ±30 rpm |
| Temp Range | –5 °C to +35 °C |
| Temp Accuracy | ±1 °C |
| Noise Level | <65 dB(A) |
| Power Supply | AC 220 V, 50 Hz, 15 A |
| Refrigerant | R22a |
| Brand | DELEITE |
|---|---|
| Origin | Shanghai, China |
| Model | FB-12 / FB-24 |
| Automation Level | Manual |
| Channel Count | 12 or 24 parallel ports |
| Extraction Format | Cartridge-based (SPE column) |
| Flow Control | Individual manual valve per channel |
| Solvent Compatibility | Multi-solvent (polar to non-polar, including methanol, acetonitrile, ethyl acetate, hexane, dichloromethane) |
| Sample Capacity | 12 samples (FB-12) or 24 samples (FB-24) simultaneously |
| Sample Loading Volume | 1–50 mL (dependent on SPE cartridge specifications) |
| Wetted Materials | Borosilicate glass (vacuum chamber, solvent reservoir, collection tray), PTFE (valves, sealing gaskets), chemically resistant polypropylene (support frame and adjustable tube rack) |
| Vacuum Source | External diaphragm vacuum pump (optional, not included) |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | CellSmart |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2770 × g |
| Max Capacity | 2×10×15 mL, 2×3×50 mL, 2×12×5 mL, 2×21×2 mL, 2×15×10 mL |
| Dimensions (W×D×H) | 384 × 288 × 480 mm |
| Rotor Configuration | Horizontal swing-out rotor |
| Application Scope | Cell & bacterial pelleting |
| Drive System | Brushless DC motor |
| Chamber Material | Stainless steel interior |
| Control Interface | Microprocessor-based with high-brightness LED display |
| Features | Instant spin button, rpm/RCF toggle key, low-noise airflow ducting, ambient temperature stability during operation |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | CellSmart |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 0–4000 rpm |
| Max RCF | 2770 × g |
| Max Capacity | 6 × 50 mL |
| Rotor Configuration | Horizontal (swing-out) rotor system |
| Sample Compatibility | Cells, bacteria, blood tubes, microcentrifuge tubes, cryovials |
| Dimensions (W×D×H) | 288 × 384 × 480 mm |
| Construction | All-metal housing, stainless-steel chamber |
| Drive System | Brushless DC motor |
| Display | High-brightness LED, rpm/rcf toggle function |
| Control | Microprocessor-based, instant spin button |
| Noise Level | ≤55 dB(A) |
| Thermal Management | Optimized airflow ducting for minimal temperature rise |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | MiniSmart |
| Instrument Type | Benchtop Portable Centrifuge |
| Maximum Speed | 6500 rpm |
| Maximum RCF | 2000 × g |
| Capacity | 6 × 1.5/2 mL tubes or 2 × 8 × 0.2 mL PCR strips |
| Dimensions | 120 × 130 × 140 mm |
| Weight | 0.5 kg |
| Rotor Configuration | Fixed-angle rotors (interchangeable) |
| Intended Use | Routine separation of biological macromolecules (e.g., DNA, RNA, proteins, cell lysates) in low-speed applications |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | HR220 / HB220 |
| Type | Benchtop Microcentrifuge |
| Max Speed | 6500 rpm |
| Max RCF | 2000 × g |
| Capacity | 6 × 1.5/2.0 mL or 2 × 8 × 0.2 mL PCR tubes |
| Dimensions | 130 × 120 × 140 mm |
| Weight | 494 g |
| Power Supply | 220 V, 50 Hz |
| Compliance | CE-marked for laboratory use under IEC 61010-1 |
| Brand | DHS |
|---|---|
| Origin | Beijing, China |
| Model | MPC2000 |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | Up to 4500 rpm |
| Max RCF | 2860 × g |
| Capacity | 6 × 96-well plates (e.g., PCR, ELISA, deep-well plates) |
| Alternate Configurations | 2 × deep-well/PCR plates or 8 × 15 mL conical/tube centrifuge tubes |
| Rotor Options | H-type plate rotor (max height 55 mm), 8-position horizontal tube rotor, and optional 96×0.2 mL PCR plate adapter kit |
| Drive System | Brushless DC motor, direct drive |
| Safety | Electronic lid lock with interlock |
| Operation Modes | Instant spin (short-run), timed run |
| Construction | All-metal housing, stainless-steel chamber |
| Dimensions (W×D×H) | 288 × 384 × 480 mm |
| Brand | DHS |
|---|---|
| Origin | Beijing, China |
| Model | MPC2000 |
| Instrument Type | Benchtop Centrifuge |
| Centrifugation Category | Low-Speed Centrifuge (≤4500 rpm) |
| Rotor Configuration | Horizontal Swing-Out Rotor |
| Maximum Capacity | 6 × 96-well ELISA plates / 2 × deep-well plates / 2 × PCR plates (with adapter) |
| Max Speed | 4500 rpm |
| Max RCF | 2860 × g |
| Dimensions (L×W×H) | 280 × 380 × 480 mm |
| Noise Level | <56 dB(A) |
| Motor | Brushless DC Direct Drive |
| Speed Range | 500–4500 rpm |
| Timer Range | 1–99 min + continuous mode |
| Power Supply | 220 V / 50 Hz / 350 W |
| Weight | 35 kg |
| Temperature Rise | <10 °C during operation |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | MPC2000 PRO |
| Instrument Type | Benchtop Centrifuge |
| Configuration | Horizontal Rotor Centrifuge |
| Max Capacity | 6 × cell culture plates / microplates / skirted PCR plates |
| Max Speed | 4500 rpm |
| Max RCF | 2860 × g |
| Dimensions (W×H×D) | 384 × 288 × 480 mm |
| Power Supply | 220 V / 50 Hz, 750 W |
| Temperature Range | Ambient +5 °C to 45 °C |
| Speed Range | 300–4500 rpm |
| Timer Range | 1 s–99 min 59 s or 1 min–99 h 59 min |
| Acceleration Steps | 9 levels |
| Deceleration Steps | 10 levels |
| Display | 3.5-inch LCD screen |
| Net Weight | 35 kg |
| Brand | DHS |
|---|---|
| Origin | Beijing, China |
| Model | NX-1 |
| Centrifuge Type | Benchtop High-Speed Centrifuge |
| Rotor Type | Fixed-Angle Rotors |
| Max Speed | 17500 rpm |
| Max RCF | 23300 × g |
| Max Capacity | 12 × 5.0 mL |
| Dimensions (W×D×H) | 235 × 400 × 270 mm |
| Net Weight | 16 kg |
| Noise Level | <60 dB(A) at Max Speed |
| Temperature Rise | <10 °C after 20 min at Max Speed |
| Speed Range | 300–17500 rpm (100 rpm increments) |
| Time Setting | 1 s–99 min, Continuous, Soft-Stop, Pulse Mode |
| Power Supply | 220 V / 50 Hz |
| Rotor Options | 12×1.5/2.0 mL, 24×1.5/2.0 mL, 12×5.0 mL, 18×2.0 mL spin columns, 8×8×0.2 mL PCR strip rotor |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-1 Pro |
| Centrifuge Type | Benchtop High-Speed Microcentrifuge |
| Speed Range | 200–17,500 rpm |
| Max RCF | 23,300 × g |
| Max Capacity | 24 × 1.5/2.0 mL tubes |
| Rotor Type | Fixed-Angle |
| Separation Target | Organelles, Viruses, Macromolecular Complexes |
| Dimensions (W×D×H) | 295 × 227 × 395 mm |
| Cooling | None (Non-refrigerated) |
| Compliance | CE, ISO 13485 (Manufacturing), IEC 61010-1 |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-1 Pro |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–17,500 rpm |
| Max RCF | 23,300 × g |
| Max Capacity | 12 × 5 mL (angle rotor) |
| Dimensions (W×D×H) | 295 × 227 × 395 mm |
| Noise Level | ≤58 dB(A) at max speed |
| Acceleration/Deceleration | 10-step programmable ramp control |
| Programmable Methods | 100 user-defined protocols |
| Display | 5-inch capacitive touch screen |
| Compliance | CE, ISO 13485 (manufacturing), IEC 61010-1 safety standard |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-1/1R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–17,500 rpm |
| Max RCF | 23,300 × g |
| Max Capacity | 12 × 5 mL tubes |
| Temperature Range | –20 °C to +40 °C |
| Refrigeration System | Eco-friendly non-CFC compressor |
| Dimensions (W×D×H) | 325 × 295 × 540 mm |
| Noise Level | ≤58 dB(A) |
| Rotor Type | Fixed-angle rotor |
| Compliance | CE, ISO 13485 (manufacturing), IEC 61010-1 |
| Certifications | Factory-tested per EN 61010-2-020 for centrifuges |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-1R Pro |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | 200–17,500 rpm |
| Max RCF | 23,300 × g |
| Max Capacity | 24 × 1.5/2.0 mL tubes |
| Temperature Range | –20 °C to +40 °C |
| Refrigeration System | Eco-friendly non-CFC compressor |
| Dimensions (W×D×H) | 355 × 270 × 545 mm |
| Display | 5-inch HD color touchscreen |
| Acceleration/Deceleration | 10-step programmable |
| Programs | 100 user-storable, up to 10-segment per program |
| Rotor Options | 5 interchangeable high-speed fixed-angle rotors |
| Tube Compatibility | 0.2–5.0 mL conical, round-bottom, PCR strip tubes, spin columns |
| Safety Features | Electronic lid lock, overspeed protection, overtemperature protection, condensation-resistant chamber |
| Construction | Full metal housing with epoxy powder coating |
| Data Logging | Real-time curve recording and historical run logs |
| Compliance | Designed for GLP-compliant workflows |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Instrument Type | Benchtop Centrifuge |
| Category | High-Speed Refrigerated Centrifuge (10,000–30,000 rpm range) |
| Function | Refrigerated Centrifugation |
| Configuration | Fixed-Angle Rotor System |
| Target Applications | Biomolecular Separation |
| Maximum Capacity | 24 × 2 mL |
| Maximum Speed | 17,500 rpm |
| Maximum RCF | 23,300 × g |
| Dimensions (W × D × H) | 325 × 295 × 540 mm |
| Temperature Range | −20 °C to +40 °C |
| Acceleration/Deceleration Steps | 9-step acceleration, 10-step deceleration |
| Rotor Options | Five interchangeable fixed-angle rotors (12 × 1.5/2.0 mL, 24 × 1.5/2.0 mL, 12 × 5.0 mL, 18 × 2.0 mL spin-column, 8 × 8 × 0.2 mL PCR strip) |
| Speed Setting Range | 300–17,500 rpm |
| Time Setting | 1 s–99 min 59 s or 1 min–99 h 59 min |
| Display | 5-inch full-color capacitive touchscreen |
| Stored Programs | 100 user-defined protocols |
| Program Structure | Up to 10 segments per program (minimum 1) |
| Data Logging | Graphical run curves and chronological history logs with timestamped metadata |
| Brand | DHS |
|---|---|
| Origin | Beijing, China |
| Model | NX-1R |
| Instrument Type | Benchtop Centrifuge |
| Speed Range | High-Speed (10,000–30,000 rpm) |
| Cooling Function | Refrigerated |
| Configuration | Fixed-Angle Rotor Centrifuge |
| Separation Class | Biomacromolecules |
| Maximum Capacity | 12 × 5 mL |
| Maximum Speed | 17,500 rpm |
| Maximum RCF | 23,300 × g |
| Dimensions (W × D × H) | 270 × 355 × 550 mm |
| Noise Level | <50 dB(A) at Max Speed |
| Minimum Temperature | ≤−20 °C |
| Cooling Rate | From RT to 0 °C in <10 min |
| Operating Temp Stability | Maintains ≤4 °C during high-speed runs |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-2R |
| Instrument Type | Benchtop Refrigerated Centrifuge |
| Speed Range | 300–18,500 rpm (100 rpm increments) |
| Max. Capacity | 4 × 100 mL |
| Max. Speed | 18,500 rpm |
| Max. RCF | 26,000 × g |
| Temperature Range | –20 °C to 40 °C (1 °C increments) |
| Timer | 1 s–59 s–1 min–99 min, continuous mode, soft spin |
| Rotor Recognition | Automatic |
| Noise Level | ≤65 dB(A) |
| Dimensions (W×D×H) | 360 × 330 × 630 mm |
| Net Weight | 46 kg |
| Power Supply | 220 V / 50 Hz |
| Safety Features | Electronic door lock, reinforced metal housing, thick-walled rotor chamber, overtemperature shutdown, auto-rotor ID |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model | NX-2R |
| Instrument Type | Benchtop Centrifuge |
| Category | High-Speed Refrigerated Centrifuge (10,000–30,000 rpm) |
| Max. Speed | 18,500 rpm |
| Max. RCF | 26,000 × g |
| Max. Capacity | 4 × 100 mL |
| Temperature Range | –20 °C to +40 °C |
| Dimensions (W×D×H) | 360 × 330 × 630 mm |
| Rotor Compatibility | 10 interchangeable rotors (including fixed-angle and PCR strip rotors) |
| Tube Compatibility | 0.2, 1.5, 2.0, 5.0, 15, and 50 mL tubes |
| Safety Features | Electronic lid lock, rotor auto-recognition, overtemperature shutdown, reinforced stainless-steel chamber, thickened metal housing |
| Brand | DHS |
|---|---|
| Origin | Tianjin, China |
| Model No. | 0401321 |
| Type | Benchtop Centrifuge |
| Speed Range | 300–21,000 rpm |
| Max RCF | 33,500 × g |
| Max Capacity | 6 × 250 mL |
| Temperature Range (NX-3R Pro only) | −20 °C to 40 °C |
| Acceleration/Deceleration | 9-step acceleration, 10-step deceleration |
| Rotor Recognition | Automatic |
| Program Storage | 100 user-defined protocols (up to 10 segments per program) |
| Display | 7-inch HD color touchscreen |
| Drive System | Inverter-controlled brushless motor |
| Safety Features | Electronic imbalance detection, lid interlock, overspeed/overtemperature protection |
| Dimensions (NX-3 Pro) | 435 × 330 × 545 mm |
| Weight (NX-3 Pro) | 36 kg |
| Power Supply | 220 V / 50 Hz |
| Rated Power (NX-3 Pro/NX-3R Pro) | 800 W / 1500 W |