| Brand | ACV |
|---|---|
| Origin | Shandong, China |
| Model | MoleDete C |
| Instrument Type | Gradient Thermal Cycler |
| Sample Throughput | Interchangeable reaction modules including 96×0.2 mL gradient single-block, 96×0.2 mL / 48×0.5 mL gradient deep-well block, dual 48×0.2 mL gradient block, 384-well single-block gradient module, and qPCR gradient module |
| Max Heating/Cooling Rate | 5 °C/sec (with optional rapid module) |
| Temperature Accuracy | ±0.2 °C |
| Well-to-Well Temperature Uniformity | ±0.4 °C (within 10 sec at 90 °C) |
| Brand | ACV |
|---|---|
| Origin | Shandong, China |
| Model | ProLux Series |
| Instrument Type | WB Imaging & Processing System |
| Automation Level | Fully Automated |
| Transfer Method | Wet Transfer |
| Maximum Gel Capacity (Electrophoresis) | 4 mini-gels |
| Maximum Transfer Capacity | 2 gels (100 mm × 75 mm) |
| Temperature Control Range | 2–40 °C (Peltier-based) |
| Incubation Channels | 12 independent channels |
| Membrane Throughput | up to 24 membranes per run |
| Wash Buffer Volume Control | Adjustable per cycle |
| Imaging Sensor | High-sensitivity cooled CMOS |
| Light Sources | LED-based transillumination and epi-illumination |
| Fluorescence Channels | RGB + Far-Red/NIR (upgradable) |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compatible workflow logging |
| Brand | ACV |
|---|---|
| Origin | Shandong, China |
| Model | TraceNac Series |
| Sample Throughput | 96-well format |
| Detection Principle | Digital PCR (dPCR) with Magnetic Bead-Based Nucleic Acid Extraction |
| DNA Detection Limit | Absolute quantification of target nucleic acid at ≤0.1% mutant allele frequency |
| Instrument Category | Ultra-micro Nucleic Acid and Protein Analyzer |
| Compliance | Designed for GLP-compliant workflows |
| Brand | ACV |
|---|---|
| Origin | Shandong, China |
| Model | NuacGel Series |
| Instrument Type | Standard Gel Imaging System |
| Electrophoresis Module | Horizontal Benchtop Unit with Dual-Side Casting Platform |
| Imaging Module | Compact CMOS-Based UV/Visible Gel Documentation System |
| Power Supply | Programmable Constant Voltage/Constant Current Source with Real-Time Monitoring and Multi-Step Method Support |
| Compliance | Designed for ISO/IEC 17025-aligned laboratory workflows |
| Safety Features | Interlocked transparent chamber, UV shielded viewing window, emergency stop button, automatic power cutoff on lid opening |
| Sample Throughput | Up to four 70 mm × 70 mm or two 70 mm × 70 mm + two 70 mm × 100 mm gels simultaneously |
| Imaging Sensor | High-sensitivity monochrome CMOS sensor with adjustable exposure and auto-focus optics |
| Software | Image Lab Touch™ embedded interface with automated capture, background subtraction, band intensity quantification, molecular weight estimation, and export-ready TIFF/PNG/JPEG output |
| Brand | ACV |
|---|---|
| Model | BloFlu 96/96Pro |
| Instrument Type | Real-Time Fluorescence Quantitative PCR System |
| Sample Throughput | 96-well and 384-well formats |
| Heating Rate | 5°C/s |
| Temperature Accuracy | ±0.2°C |
| Well-to-Well Temperature Uniformity | ±0.3°C |
| Excitation/Detection Technology | Fixed-Optics Light-Path System (Patented “Light-Shuttle” Architecture) |
| Calibration | Factory-Pre-Calibrated for All Fluorescence Channels |
| Control Interface | Integrated Touchscreen with Real-Time Signal Monitoring |
| Data Handling | Automated Data Transfer and On-Device Analysis |
| Thermal Gradient Function | Programmable Linear Gradient Across Block (Spanning up to 30°C) |
Show next