Empowering Scientific Discovery

Shandong Lanjing Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLanjing
ModelLJ-201
Measurement PrincipleSalicylate Spectrophotometry
Measurement Ranges(0–5), (0–10), (0–25), (0–50), (0–125), (0–250) mg/L NH₃–N
Zero Drift±0.02 mg/L
Span Drift±1.0% F.S.
Accuracy±8.0% at 20% F.S., ±5.0% at 50% F.S., ±3.0% at 80% F.S.
Limit of Quantitation0.15 mg/L
Repeatability≤2.0%
Cycle Time≤60 min
MTBF≥720 h
Insulation Resistance>20 MΩ
Output InterfacesRS232 / RS485, 4–20 mA analog
Dimensions500 × 440 × 1440 mm (L×W×H)
Weight55 kg
Display7-inch color touch screen
Control SystemIndustrial PLC
Operating Temperature5–35 °C
Operating Humidity20–85% RH
Power SupplyAC 220 V ±25 V, 50 Hz ±0.5 Hz
Rated Power100 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLanjing
OriginShandong, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelLJ-PF1000
CO₂ Range0–2000 ppm (customizable)
CH₄ Range0–100 ppm (customizable)
H₂O Range0–6%
CO₂ Precision±0.1 ppm @ 1 Hz
CH₄ Precision±10 ppb @ 1 Hz
H₂O Accuracy±1.5% of reading
Temperature Accuracy±0.1 °C (20–60 °C)
Sampling Flow Rate1 L/min (adjustable)
Chamber DimensionsØ220 mm × 120 mm H
Chamber Volume3140 cm³
Battery Life8 hours (Li-ion)
Operating Temp.−30 to +60 °C
Operating Humidity<99% RH (non-condensing)
Weight<10 kg
Data OutputReal-time flux & respiration rate calculation
ConnectivityWi-Fi, BeiDou/GPS dual-mode (optional)
Expandability预留RS485, analog, and digital I/O ports for optional sensors (PAR, soil T/RH, anemometer, 4G telemetry)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLanjing
OriginShandong, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelLJ-TZMn
Instrument TypeBenchtop Laboratory Analyzer
Detection PrinciplePhotometric Method (Formaldehyde Oxime & Potassium Periodate)
Target AnalyteTotal Manganese (Mn)
Detection Range0–5 mg/L
Detection Limit0.1 mg/L
Accuracy≤ ±5% FS
Stability< 0.5% (20 min)
Repeatability< 0.5% RSD
Optical Drift≤ 0.002 A in 20 min
Light SourceImported High-Brightness LED with Auto-Calibration
Cuvette Compatibility10 mm, 30 mm, 50 mm rectangular cuvettes & φ16 mm round tubes
Display8-inch TFT-LCD Touchscreen (1024 × 768)
OSAndroid 7.1.1
Data Storage8 million records
ConnectivityWi-Fi, RJ45, Bluetooth, Mobile Hotspot, USB 2.0, HDMI
Cloud PlatformIntegrated Regulatory Compliance Cloud (LAN/WAN upload
PrinterBuilt-in Thermal Line Printer (QR code supported)
Power SupplyAC 220 V ±10%, 50 Hz / Optional 6 Ah Li-ion Battery
Dimensions367 × 243 × 125 mm
Weight5.3 kg
Operating Environment5–40 °C, RH < 85% (non-condensing)
Rated Power10 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLanjing
OriginShandong, China
Manufacturer TypeManufacturer
Country of OriginChina
ModelLJ-ZGSG
Instrument TypeOnline Analyzer
Measurement Ranges0–30 ppb, 0–500 ppb, 0–5000 ppb
Accuracy±1% F.S.
Repeatability±1% F.S.
Drift≤±1% F.S. / 24 h
Response Time12 min (initial)
Sampling Cycle~10 min per channel
Sample Flow Rate>100 mL/min
Sample Temperature10–45 °C
Sample Pressure10–100 kPa
Ambient Temperature5–45 °C
Relative Humidity<85% RH
Reagent Consumption~3 L/month per reagent (3 reagents total)
Output4–20 mA (configurable, per-channel independent)
Alarm OutputRelay NO contact (220 VAC / 1 A)
Power SupplyAC 220 V ±10%, 50 Hz
Power Consumption≈50 VA
Dimensions (H×W×D)720 × 460 × 300 mm
Panel Cutout665 × 405 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLanjing
OriginShandong, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
ModelLJ-DCY
PriceUSD 5,000 (FOB Qingdao)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0