Empowering Scientific Discovery

Shandong Renke Measurement & Control Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRenKe
OriginShandong, China
Manufacturer TypeManufacturer
Country of OriginDomestic (China)
ModelRS-WD-*-2
PricingUpon Request
Power Supply10–30 V DC
Output Options4–20 mA / 0–5 V / 0–10 V
Default Accuracy±0.5 °C @ 25 °C
Operating Ambient Temp−40 °C to +60 °C
Probe Temp Range−40 °C to +120 °C (varies by probe type)
Humidity Range (probe)0–99 %RH
Long-Term Stability≤0.1 °C/year
Response Time≤10 s (at 1 m/s airflow)
Load Capacity≤600 Ω (current), ≤250 Ω (voltage)
Enclosure TypeIP65-rated wall-mounted “Wangzi” (character-style) housing
MountingScrew + anchor (included)
Added to wishlistRemoved from wishlist 0
Add to compare
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRenKe
OriginShandong, China
Manufacturer TypeManufacturer
Product CategoryDomestic
ModelRS-HW-N01
Instrument TypeFixed-mount
Power Supply10–30 V DC
Power Consumption0.4 W
Sensor TypeDual-element pyroelectric infrared (PIR) sensor
Alarm Duration Options5 s / 10 s / 30 s (configurable)
Delay-on-AlarmSoftware-configurable
Mounting MethodCeiling-mounted
Installation Height2.5–6 m
Detection RangeØ6 m (at 3.6 m mounting height)
Detection PatternOmnidirectional 360° horizontal coverage
Output InterfaceRS-485
Communication ProtocolModbus-RTU
Operating Temperature−10 °C to +50 °C
Operating Humidity≤95% RH (non-condensing)
RFI Immunity20–1000 MHz
Microcontroller8-bit low-power CMOS
Auto Temperature CompensationYes
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRenKe
OriginShandong, China
Manufacturer TypeOEM/ODM Manufacturer
Country of OriginChina
ModelRS-WS-DY
CommunicationFHSS Radio (868 MHz ISM Band)
Display2.8" LCD with Real-Time Temp/RH/Time/Address/Storage Status
Power Supply10–30 V DC (AC/DC Adapter Included for 220 V AC Input)
Operating Temperature (Electronics)−20 °C to +60 °C
Operating Humidity (Electronics)0–80 %RH
Sensor Operating Range (Standard Probe)−40 °C to +80 °C, 0–99 %RH
Sensor Operating Range (Optional −B Wide-Temp Probe)−40 °C to +120 °C
Accuracy (Class A)±0.4 °C @ 25 °C, ±2 %RH @ 25 °C (5–95 %RH)
Accuracy (Class B, Default)±0.5 °C @ 25 °C, ±3 %RH @ 25 °C (5–95 %RH)
Resolution0.1 °C / 0.1 %RH
Long-Term Drift≤0.1 °C/year, ≤1 %RH/year
Response Time (Standard Probe)≤25 s (Temp), ≤8 s (RH) at 1 m/s airflow
Response Time (−B Probe)≤18 s (Temp), ≤6 s (RH) at 1 m/s airflow
Data Storage Capacity65,535 records
Recording Interval1–65,535 minutes (configurable, default 30 min)
Storage Duration (at 30-min interval)~4 years
Storage ModeAuto-cyclic overwrite
Alarm Outputs2 programmable relay outputs (NO/NC), 1 internal buzzer (85 dB), optional external sound-light alarm interface
CalibrationPassword-protected on-device offset calibration for temperature and humidity
ComplianceFCC Part 15 Subpart C, CE RED Directive 2014/53/EU, RoHS 2011/65/EU
Wireless ProtocolProprietary FHSS (Frequency-Hopping Spread Spectrum), 868 MHz, 100 kbps data rate
Line-of-Sight Range≥800 m
Wall Penetration3–4 reinforced concrete walls
Max Nodes per RS-JSQ-W Gateway200 units
Enclosure RatingIP65 (housing), IP67 (optional −B and −6 waterproof probe variants)
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0