Add to compare
BrandANJIE
OriginShanghai, China
ModelAJ-500 / AJ-900
Sample Tray Configurations90-position (86 × 15 mL + 4 × 50 mL) or 51-position (51 × 50 mL)
Detector InterfacePhotomultiplier Tube (PMT) Compatible
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANJIE
OriginShanghai, China
ModelAJ-5100
Measurement PrinciplePotassium Permanganate Oxidation with ORP Endpoint Detection
Instrument TypeBenchtop Laboratory Analyzer
Range0–4.5 mg/L as O₂
RepeatabilityRSD ≤ 5.0%
Accuracy±10% of reading
Limit of Detection< 0.07 mg/L
Resolution1 µL
Sample Analysis Time3 min 50 s per sample
Heating MethodInfrared Rapid Boiling (reaches boiling within 100 s)
Reaction ControlUser-defined oxidation holding time
Fluidic ArchitectureDedicated reagent addition station, titration analysis station, and waste discharge station
Dispensing SystemSingle-arm precision liquid handler for all reagents
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnjie
OriginShanghai, China
ModelAJ-1000
Product TypeFlow Injection Analyzer
Wavelength Range340–1100 nm
Sample Capacity162 positions
Reagent Positions3–8
Flow Cell Path Length10 mm
Light SourceTungsten-Halogen Lamp
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANJIE
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelAJ-200 (0102)
PricingAvailable Upon Request
Digestion PrincipleUV-Catalyzed Ambient-Pressure Oxidation
Sample Throughput≤2.5 min per sample
Dilution CapabilityAutomated 1–40× dilution for high-concentration samples
IntegrationCompatible with AJ-3700 series analyzers
Fluidic ArchitectureClamp-free peristaltic tubing system
Reagent ManagementModular reagent rack support included
ComplianceDesigned to support ISO 11905-1, EPA Method 351.2, and GB/T 11894–1989 workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnjie
OriginShanghai, China
ModelAJ-3000 Plus
Detector TypePhotomultiplier Tube (PMT)
Wavelength Range190–900 nm
Spectral Bandwidth0.1 nm, 0.2 nm, 0.4 nm, and 1.0 nm (selectable)
Wavelength Accuracy±0.2 nm
Wavelength Repeatability0.1 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANJIE
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelAJ-600
PricingAvailable Upon Request
Dispensing Volume Range50–1000 mL
Dispensing Accuracy≤ ±2%
Temperature Control Range4–60 °C
Temperature Stability±1 °C
Full-Volume Preparation Time<15 min
Onboard Protocol Storage≥10 preloaded methods
Integrated Log SystemAudit-trail-capable user activity logging
Touchscreen InterfaceColor LCD with intuitive GUI
Built-in FunctionsAutomated stirring, temperature regulation, system self-cleaning, headspace liquid-path purging, method recall and execution
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnjie
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Instrument CategoryDomestic
ModelAJ-510
QuotationUpon Request
Detector TypePhotomultiplier Tube (PMT)
Wavelength Range190–900 nm
Spectral Bandwidth2.0 nm
Wavelength Accuracy±0.2 nm
Wavelength Repeatability±0.1 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANJIE
OriginShanghai, China
ModelAJ-3400 Series
Detector TypePhotomultiplier Tube (PMT)
Wavelength Accuracy±0.2 nm
Wavelength Repeatability0.1 nm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnjie
OriginShanghai, China
ModelAJ-6400
Target AnalytesThallium (Tl), Lithium (Li)
Response Time≤2 min
Power SupplyIntegrated Rechargeable Li-ion Battery (≥12 h continuous operation)
Operating PressureAmbient Atmospheric Pressure
Sample IntroductionDirect Liquid Injection (No Pretreatment Required)
Data Storage Capacity>2000 Records with Real-time Spectral Display
ConnectivityUSB for Data Export & Firmware Update
ComplianceDesigned for Field Deployment under ISO/IEC 17025-aligned QA/QC Practices
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANJIE
OriginShanghai, China
ModelAJ-3150 Plus
Instrument TypeLaboratory Analyzer
Measurement PrincipleGas-Phase Chemiluminescence (GPC) with Onboard Oxidation
Measurement Range0.08–100 mg/L NH₃–N
Accuracy≤ ±5% of reading
Detection Limit0.02 mg/L NH₃–N
Analysis Time per Sample1–3 minutes
Batch Capacity80 samples
Air SupplyIntegrated Clean Air Generator (Atmospheric Pressure, No High-Pressure Cylinders Required)
Onboard FunctionsIntegrated Oxidation Module, Heating Module (for Nitrate & Total Nitrogen), Homogenizing Sparging System, Refrigerated Water Trap, Sintered-Glass Gas–Liquid Separator, Real-Time Graphical Monitoring, Auto-Dilution (≥40×), Adjustable Lamp Current & Automatic Light Gain Control
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANJIE
OriginShanghai, China
ModelAPA-500
PrinciplePotassium Permanganate Oxidation with ORP Endpoint Detection
TypeOnline Analyzer
Range0–5 mg/L
Repeatability±2% RSD
Accuracy±5% of reading
LOD0.05 mg/L
Resolution1 µL
Cycle Time4 min per sample
Temperature Control40–100 °C (adjustable water bath)
Environmental MonitoringIntegrated ambient temperature, humidity, and atmospheric pressure sensors
Sample HandlingMotorized adaptive gripper (pneumatic-free)
Endpoint DetectionRGB-spectral colorimetric endpoint simulation with real-time video recording
ComplianceDesigned for ISO 8467:2021, EPA Method 4500-PERM, and GB/T 5750.7–2023
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnjie
OriginShanghai, China
ModelAJ-5750
Instrument TypeLaboratory Benchtop Analyzer
Measurement PrincipleRapid Digestion Method (Closed-Tube, Reflux-Based)
Measurement Range16–700 mg/L COD
Accuracy≤5% (vs. Certified Reference Materials)
RepeatabilityRSD ≤2.0%
Analysis Time14 minutes per sample
Batch Capacity≥21 samples
Safety DesignFully Enclosed Digestion Chamber with Spherical Condenser
Operational AlertReal-Time Reagent Vacuum Loss Detection
Compliance ContextDesigned to support ISO 6060, ASTM D1252–06 (Method B), and HJ 828–2017 (Chinese EPA Standard)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnjie
OriginShanghai, China
ModelAJ-6400A
Detection TargetThallium (Tl) in aqueous samples
Response Time≤2 min
Power SupplyIntegrated rechargeable lithium battery (≥12 h continuous operation)
Data Storage>2000 measurement records with real-time spectral display
InterfaceTouchscreen GUI, USB for data export & firmware update
Operating EnvironmentAmbient atmospheric pressure, no external gas supply or AC power required
Sample HandlingDirect liquid injection, no pretreatment
CalibrationBuilt-in standard curves + on-site curve generation capability
Remote DiagnosticsSupported
Added to wishlistRemoved from wishlist 0
Add to compare
BrandANJIE
OriginShanghai, China
ModelAJ-6100
Instrument TypeAutomated Iodine-Specific Elemental Analyzer for Urine, Water and Salt Matrices
Regulatory ContextDesigned for compliance with WS/T 107.1–2016 (China), ISO 8468:1996 (Water Quality – Determination of Iodide), and USP <232>/<233> elemental impurities guidance frameworks
Cooling MethodIntegrated Peltier-based water bath refrigeration
Digestion ArchitectureGraphite block digestion with reflux condensation
Reagent ConsumptionOptimized for ≤1.5 mL per sample (standard protocol)
ThroughputUp to 48 samples per batch (with optional autosampler)
Safety ComplianceMeets GB/T 18204.1–2013 (Public Health Inspection Standards) for laboratory ventilation integration
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAnjie
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Instrument TypePhotomultiplier Tube (PMT) Detector
Wavelength Range190–900 nm
Spectral Bandwidth0.1 nm / 0.2 nm / 0.4 nm / 1.0 nm (selectable)
Wavelength Accuracy±0.2 nm
Wavelength Repeatability±0.1 nm