| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Acona Technology Co., Ltd. |
| Model | A7000 AD |
| Instrument Type | Optical Particle Counter (Single-Particle Optical Sizing, SPOS) |
| Detection Principle | Combined Extinction + Light Scattering |
| Dynamic Range | 0.5–400 µm |
| Resolution | 1024 channels, down to 0.01 µm bin width |
| Sensitivity | ≤10 ppt (particles per trillion) for large particle counting (LPC) |
| Compliance | FDA 21 CFR Part 11, cGMP/GLP-ready |
| Software | Embedded audit-trail-enabled control suite with role-based access, electronic signature, and LIMS integration capability |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Acona Technology Co., Ltd. |
| Model | A7000APS |
| Instrument Type | Optical Particle Counter (SPOS-based) |
| Detection Principle | Single Particle Optical Sensing (SPOS) with Dual-Mode Extinction + Scattering |
| Dynamic Range | 0.5 – 400 µm |
| Resolution | 0.01 µm (1024 channels) |
| Sensitivity | 10 ppt (particles per trillion) |
| Max Sample Concentration | 10¹¹ #/mL |
| Compliance | 21 CFR Part 11, USP <729>, ChP 2020 |
| Dilution System | Patented Two-Step Automatic Dilution Module |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | Acona A7000SIS |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Single Particle Optical Sizing (SPOS) with Dual-Mode Extinction & Scattering |
| Dynamic Range | 0.5–400 µm |
| Minimum Sample Volume | 50 µL |
| Resolution | 0.01 µm |
| Data Channels | 1024 |
| Sensitivity | 10 ppt (particles per trillion) |
| Compliance | USP <787>, USP <729>, 21 CFR Part 11, cGMP/GLP |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | Acona Technology Co., Ltd. |
| Model | Acona 7000 SIS |
| Instrument Type | Optical Particle Counter (SPOS-based) |
| Detection Principle | Dual-mode Extinction + Light Scattering |
| Dynamic Range | 0.5–400 µm |
| Minimum Sample Volume | 50 µL |
| Channel Resolution | 1024 channels |
| Size Resolution | 0.01 µm |
| Sensitivity | 10 ppt (particles per trillion) |
| Compliance | USP <787>, USP <729>, 21 CFR Part 11, cGMP/GLP |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | Acona7000APS |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Single-Particle Optical Sensing (SPOS) with Dual-Mode Extinction & Scattering |
| Dynamic Range | 0.5 – 400 µm |
| Resolution | 0.01 µm (1024-channel binning) |
| Sensitivity | 10 ppt (particles ≥ 0.8 µm) |
| Max Sample Concentration | 10¹¹ #/mL (with patented two-step auto-dilution) |
| Regulatory Compliance | USP <729>, CP 2020 Vol IV, 21 CFR Part 11, cGMP/GLP-ready |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Regional Category | Domestic (China) |
| Model | Acona 7000 APS |
| Instrument Type | Optical Single-Particle Counter |
| Detection Principle | SPOS (Single Particle Optical Sensing) with Dual-Mode Extinction + Scattering |
| Dynamic Range | 0.5 – 400 µm |
| Resolution | 0.01 µm (1024-channel binning) |
| Sensitivity | 10 ppt (particles per trillion) |
| Dilution Capability | Auto-dilution up to 10¹¹ #/mL original concentration |
| Regulatory Compliance | FDA 21 CFR Part 11, USP <729>, Chinese Pharmacopoeia 2020 Edition |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Product Category | Domestic |
| Model | Acona A7000 APS |
| Instrument Type | Optical Particle Counter (Light Obscuration / SPOS) |
| Detection Principle | Single Particle Optical Sensing (SPOS) with Dual-Mode Extinction + Scattering |
| Dynamic Range | 0.5–400 µm |
| Resolution | 1024 channels, down to 0.01 µm bin width |
| Sensitivity | ≤10 ppt (particles per trillion) for ≥0.8 µm |
| Max Sample Concentration | 10¹¹ particles/mL (with integrated two-step auto-dilution) |
| Regulatory Compliance | 21 CFR Part 11, USP <729>, Chinese Pharmacopoeia 2020 Edition |
| Software | Audit-trail enabled, role-based access control, electronic signature, LIMS-compatible |
| Brand | Acona |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | Acona A7000AD |
| Instrument Type | Optical Particle Counter |
| Detection Principle | Single Particle Optical Sensing (SPOS) with Dual-Mode Extinction & Scattering |
| Dynamic Range | 0.5 – 400 µm |
| Resolution | 0.01 µm |
| Channel Count | 1024 |
| Sensitivity | 10 ppt (particles per trillion) |
| Compliance | FDA 21 CFR Part 11, cGMP, GLP |