- All
- Favorite
- Popular
- Most rated
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HS-TGA-302 |
| Test Environment | Ambient Pressure |
| Sample Capacity | 1 sample per run |
| Instrument Type | General-purpose |
| Temperature Range | RT to 1300 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 1 µg |
| Heating/Cooling Rate | 0–100 °C/min |
| Maximum Sample Mass | 5 g |
| Baseline Drift | ≤10 µg |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Transient Plane Source Method |
| Sample Capacity | Single sample per test |
| Test Environment | Ambient temperature (20–30 °C) |
| Dimensions (L×W×H) | 450 × 385 × 165 mm |
| Accuracy | ≤3% |
| Thermal Conductivity Range | 0.005–300 W/(m·K) |
| Repeatability | ≤3% |
| Probe Options | 7.5 mm and 15 mm diameter dual-spiral probes |
| Measurement Time | 5–160 s (user-configurable) |
| Max. Sample Temperature Rise | <15 °C |
| Power Supply | 220 V AC, <500 W |
| Compatible Sample Forms | Solid blocks, powders, pastes, gels, liquids, coatings, films, foams, and insulating materials |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HS-STA-302 |
| Price | Upon Request |
| Temperature Range | RT to 1300 °C |
| Heating Rate | 0.1–100 °C/min |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 3 g |
| Atmosphere | Nitrogen (dual-gas automatic switching, 0–300 mL/min, ≤0.5 MPa) |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Regional Category | Domestic (China) |
| Model | HS-TGA-101 |
| Operating Environment | Ambient Pressure |
| Sample Capacity | Single Sample |
| Instrument Type | General-Purpose |
| Temperature Range | RT to 1150 °C |
| Temperature Accuracy | ±0.1 K |
| Balance Sensitivity | 10 µg |
| Heating/Cooling Rate | 1–80 °C/min |
| Maximum Sample Mass | 2 g |
| Baseline Drift | ≤10 µg |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Origin | Domestic (China) |
| Model | HS-STA-002 (Simultaneous TGA-DTA Analyzer) |
| Temperature Range | Ambient to 1150 °C |
| Heating Rate | 0.1–80 °C/min |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 2 g |
| Atmosphere | Nitrogen (dual-gas auto-switching, 0–300 mL/min, ≤0.5 MPa) |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | HS-STA-002 |
| Coupling Technique | Thermogravimetry–Differential Scanning Calorimetry (TG-DSC) |
| Heating Rate | 0.1–80 °C/min |
| Temperature Range | Ambient to 1150 °C |
| Temperature Stability | ±0.1 °C |
| Maximum Sample Mass | 2 g (expandable to 30 g) |
| Atmosphere Control | Dual-gas channel with automatic switching (N₂ standard) |
| Flow Rate | 0–300 mL/min |
| TG Resolution | 10 µg |
| TG Dynamic Range | 1 mg–2 g |
| DSC Range | ±700 mW |
| DSC Sensitivity | 0.001 mW |
| Temperature Resolution | 0.01 °C |
| Temperature Accuracy & Repeatability | ±0.1 °C |
| Cooling Time (1000 °C → 100 °C) | 15 min |
| Control Modes | Programmable heating, isothermal hold, and cooling |
| Data Interface | Standard USB |
| Power Supply | AC 220 V / 50 Hz |
| Dimensions (L×W×H) | 470 × 580 × 460 mm |
| Display | 7-inch 24-bit color LCD touchscreen |
| Core Processor | 32-bit ARM Cortex-M3 |
| ADC | 24-bit, 4-channel synchronous sampling for TG, DSC, and T signals |
| Brand | HESON |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | DSC |
| Sample Capacity | Single |
| Temperature Range | Ambient to 600 °C |
| Temperature Accuracy | ±0.1 °C |
| Heating/Cooling Rate | 0.1–100 °C/min |
| Temperature Precision | ±0.01 °C |
| DSC Signal Range | 0 to ±600 mW |
| Temperature Stability (Drift) | ±0.01 °C |
| DSC Resolution | 0.001 mW |
| Temperature Resolution | 0.01 °C |
| Gas Flow Control | Dual-channel automatic switching, 0–300 mL/min (customizable) |
| Calibration Standards Included | Indium, Tin, Lead |
| Thermocouple Configuration | Triple thermocouples (sample, furnace ambient, overheat safety) |
| Power Supply | AC 220 V / 50 Hz |
| Interface | Standard USB |
| Display | 7-inch 24-bit color LCD touchscreen |
Show next