Added to wishlistRemoved from wishlist 0
Add to compare
BrandJIAHANG
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
ModelJHD50
Temperature RangeAmbient to 400 °C
Temperature Resolution0.1 °C
Accuracy±0.2 °C (≤250 °C), ±0.5 °C (>250 °C)
Heating Rate0.1–20 °C/min
Sample Capacity2 samples per run
DisplayDual-screen — 5.6″ + 4.3″ color TFT LCD
User AccountsUp to 15
Predefined Methods100 stored protocols
Data InterfacesUSB, RS-232, Ethernet
GLP ComplianceYes
Power Supply220 V, 50 Hz, 120 W
Standards ComplianceASTM D3204, D3461, D3104, D3954, D6090
ISO 21761972, 4625:2
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJIAHANG
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelAIpol-JHD50
PriceUpon Request
Temperature RangeAmbient to 400 °C
Temperature Resolution0.01 °C
Heating Rate0.1–20 °C/min (200-step continuous adjustment)
Accuracy±0.2 °C (<250 °C), ±0.4 °C (>250 °C)
Repeatability±0.1 °C at 0.1 °C/min
Sample Capacity2 parallel channels (2 drop point cups: 2.8 mm orifice
2 softening point cups6.35 mm orifice)
Optical MagnificationStandard 9×, adjustable
Display10.4″ FTF color touchscreen
Data Storage64 GB internal
Method Library600 preloaded, user-lockable
User Management4-tier permission control
Audit TrailCompliant with FDA 21 CFR Part 11
Electronic SignatureEnabled
Data Export FormatsPDF, Excel
ConnectivityUSB, RS232, SD card, Wi-Fi, RJ45, U-disk interface
Barcode Scanner SupportYes
Power Supply110–230 V AC, 50/60 Hz, 120 W
Dimensions (W×D×H)430 × 320 × 370 mm
Net Weight6.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJIAHANG
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelHSY-3536D
Detection MethodCleveland Open-Cup (COC)
Operation ModeFully Automatic
Applicable StandardGB/T 3536–2008
Repeatability≤8 °C (flash point and fire point)
Ignition MethodElectronic spark ignition
Temperature RangeAmbient to 400 °C
Power SupplyAC 220 V ±10%, 50 Hz
Display8-inch industrial true-color touchscreen (Windows CE OS, bilingual Chinese/English interface)
Temperature SensorImported German PT1000 (resolution: 0.1 °C)
MicrocontrollerRenesas MCU
Data Storage120 test records onboard
Safety FeaturesAuto-shutdown on overtemperature, flame-quenching lid for fire point, real-time millisecond-level flash detection
Environmental Operating Conditions10–40 °C, RH ≤80%
Power Consumption≤500 W
Dimensions (lowered/lifted)520 × 360 × 310 / 420 mm (L×W×H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJIAHANG
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeLaboratory Wet-Dispersion Laser Diffraction Particle Size Analyzer
Measurement Range0.01 µm – 2000 µm
Repeatability<1% RSD (D50)
Measurement Time≤10 seconds per run
Dispersing Medium Volume≥180 mL (standard), optional 10 mL micro-circulation mode
Ultrasonic Power100 W with dry-run protection
Optical AlignmentFully automated mechanical–optical dual-axis centering (≤15 s, 0.2 µm step resolution)
Detector Channels121
ComplianceISO 13320:2020, GB/T 19077–2016, USP <429>, FDA 21 CFR Part 11 ready (with audit trail, electronic signature, role-based access control)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandJIAHANG
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Country of OriginChina
ModelJH-D2102
Price RangeUSD 1,400 – 2,800
Measurement PrincipleRing-and-Ball Method (ASTM D36 / ISO 4625 / ChP 2020 General Chapter 2102 / USP <741>)
Temperature Range5–80 °C (water bath) / 32–162 °C (glycerol bath)
Temp. Resolution0.1 °C
Heating Rate1.0–1.5 °C/min (linear ramp, PID-controlled)
Sample Capacity2 specimens simultaneously
StirringAdjustable magnetic stirrer (infinitely variable speed)
Detection MethodDual-channel laser beam interruption detection
Data Storage200 test records (CSV export via USB)
ComplianceFully compliant with ChP 2020 Edition General Chapter 2102, supports audit trail per FDA 21 CFR Part 11 requirements
InterfaceRS-485 (Modbus RTU)
Dimensions (L×W×H)390 × 300 × 575 mm
Weight12.0 kg
Power Supply220 ±10% VAC, 50 Hz
Max. Power Consumption≤800 W