BrandLengguang Tech
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSteady-State Fluorescence Spectrometer
ModelF96Pro
Wavelength Range (Excitation)200–850 nm
Wavelength Range (Emission)200–900 nm
Excitation Source150 W Ozone-Free Xenon Lamp (Hamamatsu, 2000 h lifetime)
MonochromatorCzerny-Turner grating monochromator with interference filters
Slit Width (Spectral Bandpass)10 nm
Spectral Resolution10 nm
Wavelength Accuracy±1.0 nm
Wavelength Repeatability≤0.5 nm
Sensitivity (S/N)>150:1 (at water Raman peak, 350 nm excitation)
Scan SpeedUp to 48,000 nm/min (10-point resolution)
Linearity (R²)≥0.995
Standard Excitation Filter365 nm interference filter
SoftwareQuantitative & qualitative analysis suite with derivative spectroscopy (1st–4th order), multi-curve overlay, kinetic time-scan, spectral math, peak integration, and calibration curve fitting (linear, quadratic, cubic)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLengguang Tech.
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelsF97 / F97PRO / F97XP
Price RangeUSD 14,000 – 28,000
Dispersive ElementHolographic Grating
Instrument TypeSteady-State Fluorescence Spectrometer
Slit Width (Spectral Bandwidth)2.0 nm to 20 nm
Resolution2.0 nm
SensitivityS/N > 200 (peak-to-peak, F97XP)
Wavelength Accuracy±0.4 nm (F97XP), ±1.0 nm (F97PRO)
Light Source150 W Ozone-Free Xenon Arc Lamp (Hamamatsu, 2000 h lifetime)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLengguang Tech.
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelF98
Price RangeUSD 14,000–28,000
Dispersive ElementDual Grating Monochromator
Instrument TypeSteady-State Fluorescence Spectrometer
Slit Width (Spectral Bandpass)1.0–20.0 nm
Spectral Resolution1.0 nm
Sensitivity>350:1 (peak-to-peak)
Wavelength Accuracy±0.4 nm
Excitation Source150 W Ozone-Free Xenon Lamp (Hamamatsu, Japan)
Emission Detection Range200–900 nm
Excitation Range200–900 nm
Minimum Sample Volume0.5 mL (standard 10 mm cuvette)
Optical SystemDual-Beam Ratio-Monitoring with Horizontal Beam Geometry
LinearityR² ≥ 0.995
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLengguang Tech
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Product CategoryDomestic
ModelF93
Price RangeUSD 1,400 – 7,000
Dispersive ElementHolographic Grating
Instrument TypeSteady-State Fluorescence Spectrometer
Slit Width (Spectral Bandpass)12 nm
Spectral Resolution12 nm
Sensitivity≤1 × 10⁻⁹ mol/L (Quinine Sulfate in 0.1 M H₂SO₄)
Wavelength Accuracy±2.0 nm
Excitation SourceHigh-Stability LED
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLengguang Tech.
OriginShanghai, China
Manufacturer TypeOriginal Equipment Manufacturer (OEM)
Instrument TypeSteady-State Fluorescence Spectrometer
Wavelength Range (Excitation)200–900 nm
Wavelength Range (Emission)200–900 nm
Slit Width (Spectral Bandpass)1.0–20.0 nm
Spectral Resolution1.0 nm
Wavelength Accuracy±0.4 nm
Signal-to-Noise Ratio (Water Raman Peak)>350:1 (peak-to-peak)
Light Source150 W Ozone-Free Xenon Arc Lamp (Hamamatsu, 2000 h lifetime)
DetectorHamamatsu R928 Red-Sensitive Photomultiplier Tube (PMT)
Optical DesignHorizontal Slit, Dual-Beam Ratio-Monitoring Excitation Path
GratingImported JY (Jobin Yvon) Blazed Grating
Excitation/Emisson Grating Blaze300 nm (EX), 400 nm (EM)
Linearity (Fluorescence Intensity)≥0.995
Scan SpeedUp to 60,000 nm/min
Supported Scanning Modes3D Fluorescence Mapping, Time-Resolved Emission Scanning, Constant-Wavelength-Difference Synchronous Scanning, Constant-Wavenumber-Difference (Constant Energy Difference) Synchronous Scanning
Quantum Yield MeasurementOptional Integrated Accessory
Standard Cuvette Volume0.5 mL (10 mm pathlength)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandLengguang Tech
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Instrument TypeSteady-State Fluorescence Spectrometer
ModelF96S
Dispersion ElementHolographic Grating
Slit Width (Spectral Bandwidth)10 nm
Spectral Resolution10 nm
Sensitivity>90:1 (Water Raman SNR)
Wavelength Accuracy±1.0 nm
Excitation Wavelength Range250–600 nm (LED-based)
Emission Wavelength Range200–650 nm
Emission Wavelength Repeatability≤0.5 nm
Standard Excitation Sources365 nm, 376 nm, 392 nm, 405 nm LEDs
Scan SpeedUp to 48,000 nm/min
Normalization FunctionFluorescence Intensity Normalization
Software ModesFluorescence Intensity & Luminescence Intensity
Data Processing1st–4th Derivative Spectra, Peak Detection, Area Integration, Multi-Curve Overlay, Ratio Analysis
Quantitative MethodsCalibration Curve (1st–3rd order), Coefficient Method
Sample FormsLiquid, Powder, Thin Film
ComplianceDesigned for ISO/IEC 17025-aligned laboratory workflows, supports GLP documentation practices