Empowering Scientific Discovery

Shanghai Mitong Mechanical & Electrical Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG (Shanghai Mitong Instrument Co., Ltd.)
OriginShanghai, China
ModelSYP-0983
Penetration Measurement Range0–700 dmm
Temperature Control Range0–65 °C
Temperature Control Accuracy±0.1 °C
Penetration Resolution0.01 mm
Maximum Penetration Depth±1 dmm
Standard Cone (No. 1)(102.5 ± 0.05) g
Cone Rod Mass(47.5 ± 0.05) g
Timing Options5, 8, 10, 12, 30, 60 s (±0.1 s accuracy)
Power SupplyAC 220 V ±10 %, 50 Hz, ≤300 W
Dimensions (L×W×H)280 × 350 × 700 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG
OriginShanghai, China
ModelSYP1015-IV
Power SupplyAC 198–242 V, 49–51 Hz
Equivalent Output Voltage Range0–220 V
Heating Power350 W
Display3.5-digit segmented LCD
Control Core8-bit microcontroller
Mains CompensationYes (voltage-fluctuation compensation via proportional heating control)
Triggering MethodZero-crossing solid-state switching
ComplianceGB/T 260, ASTM D95
Measurement Result Formatmass percent (%)
Operating EnvironmentAmbient temperature
Power Consumption350 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG
OriginShanghai, China
ModelSKY2001-I
Distillation Temperature Range0–400 °C
Receiver Bath Temperature Control0–60 °C (±0.1 °C)
Cold Bath Temperature Control0–60 °C (±0.1 °C)
Heating Power0–1200 W (continuously adjustable)
Total Power Consumption2000 W
Input Voltage220 V ±10%, 50 Hz ±1 Hz
Display10.4″ integrated LCD touch screen
Interface PortsUSB, RS-232, Ethernet
Volume Measurement Points99 programmable recovery points
Refrigeration MethodSemiconductor cooling
ComplianceGB/T 6536–2010, ISO 3405, ASTM D86, IP 123, SY/T 5648
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG (Shanghai Mitong Instrument Co., Ltd.)
OriginShanghai, China
ModelSYP-0595
Measurement Range0–650 Penetration Units (0.1 mm)
Minimum Readout0.1 Penetration Unit
Resolution0.01 mm
Penetration Accuracy±1 Penetration Unit
Timing Options5 s, 8 s, 10 s, 12 s, 30 s, 60 s (timing error < ±0.1 s)
Standard Cone Mass102.5 ± 0.05 g
Power SupplyAC 220 ± 10% V, 50 Hz, ≤300 W
Dimensions280 × 350 × 700 mm (L×W×H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG
ModelSYP-6538A
TypeFoam Trend Analyzer
Channels4
Temperature Control RangeAmbient to 100 °C
Temperature Stability±0.1 °C
Bath Capacity27 L (Dual-Cylinder Design)
Gas Flow Rate300 mL/min (N₂)
Stirring Motor6 W, 1200 rpm
Foaming TubeBorosilicate Glass with Graduations & Fritted Disc
Temperature SensorPt100 Industrial Platinum Resistance Thermometer
Power SupplyAC 220 V ±10 %, 50 Hz ±5 %
Max. Power Consumption≤1800 W
Operating Environment−10 °C to +35 °C, RH <85 %
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG (Shanghai Mitong Instrument Co., Ltd.)
OriginShanghai, China
ModelSYP-2102H
Measurement Range5–80 °C (water bath) / 32–162 °C (glycerol bath)
Temperature Resolution0.1 °C
Heating Rate1.0–1.5 °C/min
Sample Capacity2 specimens simultaneously
Bath Vessel DimensionsØ110 mm × 130 mm H
StirringAdjustable magnetic stirrer
Data Storage200 test records (.csv export via USB)
Power Supply220 VAC ±10%, 50 Hz
Max. Power Consumption800 W
Net Weight12.0 kg
Dimensions (L×W×H)390 mm × 300 mm × 575 mm
ComplianceChinese Pharmacopoeia 2020 Edition, General Chapter 2102
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG
OriginShanghai, China
ModelSYP-22459D
Penetration Range0–650 dmm (0.1 mm increments)
Minimum Readout0.1 dmm
Resolution0.01 mm
Penetration Accuracy±1 dmm
Temperature Control Range0.00–50.00 °C (±0.1 °C stability)
Timing Range0–250 s (±0.1 s accuracy)
LVDT Displacement Sensor0–66 mm range, ≤±0.1 mm repeatability
Standard Cone AssemblyTotal mass 102.5 g ±0.05 g, cone rod mass 47.5 g ±0.05 g (conforms to GB/T 22459.1–2008)
Data Storage200 test records
CommunicationRS-485 (MODBUS RTU), USB data export
Power Supply220 VAC ±10%, 50 Hz
Dimensions390 × 310 × 575 mm (L×W×H)
Net Weight12.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG (Shanghai Mitong Instrument Co., Ltd.)
ModelSYP-7534B
OriginShanghai, China
ConstructionQuartz-glass distillation apparatus
Cold Bath Temperature Control Range−10 °C to +70 °C
Condensate Cylinder Temperature Control Range−10 °C to +60 °C
Volume Detection Range0–100 mL (0.01 mL resolution)
Volume Measurement Accuracy< 0.1 mL
Distillation Rate4–5 mL/min
Heating PowerUp to 1200 W (programmable ramp control)
RefrigerationImported German compressor
Temperature SensorPt100 glass probe (IEC 60751 Class A)
Liquid Level DetectionInfrared photoelectric system
Display12.1″ embedded color touch screen
Data Storage100 test records
Power SupplyAC 220 V, 50 Hz
Max. Power Consumption1500 W
Operating Ambient10–40 °C
Storage Ambient0–50 °C
Atmospheric Pressure CompensationIntegrated barometric sensor with real-time correction
Safety FeaturesFlame detector with automatic fire suppression
Compliance StandardsGB/T 7534, GB/T 615, GB 338–2011, GB/T 6536
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG
OriginShanghai, China
ModelSYP-0983H
Penetration Range0–650 dmm
Minimum Readout0.1 dmm
Resolution0.01 mm
Penetration Accuracy±1 dmm
Temperature Control Range0.00–50.00 °C
Temperature Stability±0.1 °C
Timing Range0–250 s
Timing Accuracy±0.1 s
LVDT Displacement Sensor Range0–66 mm
Displacement Resolution0.01 mm
Cone Mass (Type I)102.5 ± 0.05 g
Cone Rod Mass47.5 ± 0.05 g
Power Supply220 ± 10% VAC / 50 Hz
Net Weight12.5 kg
Dimensions (L×W×H)390 × 310 × 575 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG
ModelSYP-476A
OriginShanghai, China
Measurement Range (H)0–20 wt%
Measurement Range (C)0–100 wt%
Combustion Furnace Temp850 °C ±3 °C
Conversion Furnace Temp350 °C ±3 °C
Temperature Control Accuracy±1 °C
H-Determination Time10 min
C-Determination Time15 min
Electrolytic Cell Dimensions250 mm length × 5 mm ID × 8 mm OD
Electrolysis Voltage (Coating)10 V
Operating Voltage24 V
Max Electrolysis Current600 mA
Endpoint Current≤65 mA
Heating Rate25–30 °C/min
Power Supply220 V AC, 50 Hz
Rated Power3 kW
Heating ElementNi-Cr Resistance Wire
Temperature SensorK-Type Thermocouple
Sample Size≤0.2 mm (80 mesh)
Sample Capacity1 per run
ComplianceGB/T 476–2008
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG (Shanghai Mitong Instrument Co., Ltd.)
OriginShanghai, China
ModelSYD-2801C-1
Penetration Range0–700 dmm
Temperature Control Range0–65 °C
Temperature Stability±0.1 °C at 25 °C
Penetration Resolution0.01 mm
Penetration Accuracy±1 dmm
Standard Needle50 mm length, 2.5 g ±0.05 g
Standard Cone102.5 g ±0.05 g
Timing Options5, 8, 10, 12, 30, 60 s (±0.1 s tolerance)
Bath TypeRigid borosilicate glass cylinder with magnetic stirrer
Power SupplyAC 220 V ±10%, 50 Hz, ≤300 W
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG (Shanghai Mitong Instrument Co., Ltd.)
OriginShanghai, China
ModelSYP-154E
Penetration Range0–650 Penetration Units (0.1 mm per unit)
Minimum Readout0.1 Penetration Unit
Resolution0.01 mm
Penetration Accuracy±1 Penetration Unit
Temperature Control Range0.00–50.00 °C (with ±0.1 °C stability)
Timing Accuracy±0.1 s (0–250 s programmable)
Displacement SensorLaser-based, 0–66 mm range, ±0.1 mm repeatability
Cone Assembly Mass37.5 g ±0.05 g (cone: 22.5 g ±0.025 g
rod15 g ±0.05 g)
Test Fixture200 mm diameter solid hemispherical PET support (Shore A hardness: 75–85)
Data Storage200 test records
CommunicationRS-485 (MODBUS RTU), USB export
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG
OriginShanghai, China
ModelSYD-24521
ComplianceGB/T 24521–2009
Sample Chamber Internal Diameter16.3 ± 0.05 mm
Compaction Mass6 kg (main weight), 1 kg (auxiliary weight)
Standard Steel Column DiameterΦ16.3 ± 0.03 mm
Sieve Apertures0.315 mm and 0.500 mm (100 mm diameter × 50 mm height)
Particle Size Ranges0.315–0.500 mm (Φ2.5 mm sieve), 0.500–1.000 mm (Φ4 mm sieve)
Leveling Sensitivity1 mm/m (200 mm spirit level)