| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-0983 |
| Penetration Measurement Range | 0–700 dmm |
| Temperature Control Range | 0–65 °C |
| Temperature Control Accuracy | ±0.1 °C |
| Penetration Resolution | 0.01 mm |
| Maximum Penetration Depth | ±1 dmm |
| Standard Cone (No. 1) | (102.5 ± 0.05) g |
| Cone Rod Mass | (47.5 ± 0.05) g |
| Timing Options | 5, 8, 10, 12, 30, 60 s (±0.1 s accuracy) |
| Power Supply | AC 220 V ±10 %, 50 Hz, ≤300 W |
| Dimensions (L×W×H) | 280 × 350 × 700 mm |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SYP1015-IV |
| Power Supply | AC 198–242 V, 49–51 Hz |
| Equivalent Output Voltage Range | 0–220 V |
| Heating Power | 350 W |
| Display | 3.5-digit segmented LCD |
| Control Core | 8-bit microcontroller |
| Mains Compensation | Yes (voltage-fluctuation compensation via proportional heating control) |
| Triggering Method | Zero-crossing solid-state switching |
| Compliance | GB/T 260, ASTM D95 |
| Measurement Result Format | mass percent (%) |
| Operating Environment | Ambient temperature |
| Power Consumption | 350 W |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SKY2001-I |
| Distillation Temperature Range | 0–400 °C |
| Receiver Bath Temperature Control | 0–60 °C (±0.1 °C) |
| Cold Bath Temperature Control | 0–60 °C (±0.1 °C) |
| Heating Power | 0–1200 W (continuously adjustable) |
| Total Power Consumption | 2000 W |
| Input Voltage | 220 V ±10%, 50 Hz ±1 Hz |
| Display | 10.4″ integrated LCD touch screen |
| Interface Ports | USB, RS-232, Ethernet |
| Volume Measurement Points | 99 programmable recovery points |
| Refrigeration Method | Semiconductor cooling |
| Compliance | GB/T 6536–2010, ISO 3405, ASTM D86, IP 123, SY/T 5648 |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-0595 |
| Measurement Range | 0–650 Penetration Units (0.1 mm) |
| Minimum Readout | 0.1 Penetration Unit |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 Penetration Unit |
| Timing Options | 5 s, 8 s, 10 s, 12 s, 30 s, 60 s (timing error < ±0.1 s) |
| Standard Cone Mass | 102.5 ± 0.05 g |
| Power Supply | AC 220 ± 10% V, 50 Hz, ≤300 W |
| Dimensions | 280 × 350 × 700 mm (L×W×H) |
| Brand | MITONG |
|---|---|
| Model | SYP-6538A |
| Type | Foam Trend Analyzer |
| Channels | 4 |
| Temperature Control Range | Ambient to 100 °C |
| Temperature Stability | ±0.1 °C |
| Bath Capacity | 27 L (Dual-Cylinder Design) |
| Gas Flow Rate | 300 mL/min (N₂) |
| Stirring Motor | 6 W, 1200 rpm |
| Foaming Tube | Borosilicate Glass with Graduations & Fritted Disc |
| Temperature Sensor | Pt100 Industrial Platinum Resistance Thermometer |
| Power Supply | AC 220 V ±10 %, 50 Hz ±5 % |
| Max. Power Consumption | ≤1800 W |
| Operating Environment | −10 °C to +35 °C, RH <85 % |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-2102H |
| Measurement Range | 5–80 °C (water bath) / 32–162 °C (glycerol bath) |
| Temperature Resolution | 0.1 °C |
| Heating Rate | 1.0–1.5 °C/min |
| Sample Capacity | 2 specimens simultaneously |
| Bath Vessel Dimensions | Ø110 mm × 130 mm H |
| Stirring | Adjustable magnetic stirrer |
| Data Storage | 200 test records (.csv export via USB) |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Max. Power Consumption | 800 W |
| Net Weight | 12.0 kg |
| Dimensions (L×W×H) | 390 mm × 300 mm × 575 mm |
| Compliance | Chinese Pharmacopoeia 2020 Edition, General Chapter 2102 |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-22459D |
| Penetration Range | 0–650 dmm (0.1 mm increments) |
| Minimum Readout | 0.1 dmm |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Temperature Control Range | 0.00–50.00 °C (±0.1 °C stability) |
| Timing Range | 0–250 s (±0.1 s accuracy) |
| LVDT Displacement Sensor | 0–66 mm range, ≤±0.1 mm repeatability |
| Standard Cone Assembly | Total mass 102.5 g ±0.05 g, cone rod mass 47.5 g ±0.05 g (conforms to GB/T 22459.1–2008) |
| Data Storage | 200 test records |
| Communication | RS-485 (MODBUS RTU), USB data export |
| Power Supply | 220 VAC ±10%, 50 Hz |
| Dimensions | 390 × 310 × 575 mm (L×W×H) |
| Net Weight | 12.5 kg |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Model | SYP-7534B |
| Origin | Shanghai, China |
| Construction | Quartz-glass distillation apparatus |
| Cold Bath Temperature Control Range | −10 °C to +70 °C |
| Condensate Cylinder Temperature Control Range | −10 °C to +60 °C |
| Volume Detection Range | 0–100 mL (0.01 mL resolution) |
| Volume Measurement Accuracy | < 0.1 mL |
| Distillation Rate | 4–5 mL/min |
| Heating Power | Up to 1200 W (programmable ramp control) |
| Refrigeration | Imported German compressor |
| Temperature Sensor | Pt100 glass probe (IEC 60751 Class A) |
| Liquid Level Detection | Infrared photoelectric system |
| Display | 12.1″ embedded color touch screen |
| Data Storage | 100 test records |
| Power Supply | AC 220 V, 50 Hz |
| Max. Power Consumption | 1500 W |
| Operating Ambient | 10–40 °C |
| Storage Ambient | 0–50 °C |
| Atmospheric Pressure Compensation | Integrated barometric sensor with real-time correction |
| Safety Features | Flame detector with automatic fire suppression |
| Compliance Standards | GB/T 7534, GB/T 615, GB 338–2011, GB/T 6536 |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-0983H |
| Penetration Range | 0–650 dmm |
| Minimum Readout | 0.1 dmm |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Temperature Control Range | 0.00–50.00 °C |
| Temperature Stability | ±0.1 °C |
| Timing Range | 0–250 s |
| Timing Accuracy | ±0.1 s |
| LVDT Displacement Sensor Range | 0–66 mm |
| Displacement Resolution | 0.01 mm |
| Cone Mass (Type I) | 102.5 ± 0.05 g |
| Cone Rod Mass | 47.5 ± 0.05 g |
| Power Supply | 220 ± 10% VAC / 50 Hz |
| Net Weight | 12.5 kg |
| Dimensions (L×W×H) | 390 × 310 × 575 mm |
| Brand | MITONG |
|---|---|
| Model | SYP-476A |
| Origin | Shanghai, China |
| Measurement Range (H) | 0–20 wt% |
| Measurement Range (C) | 0–100 wt% |
| Combustion Furnace Temp | 850 °C ±3 °C |
| Conversion Furnace Temp | 350 °C ±3 °C |
| Temperature Control Accuracy | ±1 °C |
| H-Determination Time | 10 min |
| C-Determination Time | 15 min |
| Electrolytic Cell Dimensions | 250 mm length × 5 mm ID × 8 mm OD |
| Electrolysis Voltage (Coating) | 10 V |
| Operating Voltage | 24 V |
| Max Electrolysis Current | 600 mA |
| Endpoint Current | ≤65 mA |
| Heating Rate | 25–30 °C/min |
| Power Supply | 220 V AC, 50 Hz |
| Rated Power | 3 kW |
| Heating Element | Ni-Cr Resistance Wire |
| Temperature Sensor | K-Type Thermocouple |
| Sample Size | ≤0.2 mm (80 mesh) |
| Sample Capacity | 1 per run |
| Compliance | GB/T 476–2008 |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-2801C-1 |
| Penetration Range | 0–700 dmm |
| Temperature Control Range | 0–65 °C |
| Temperature Stability | ±0.1 °C at 25 °C |
| Penetration Resolution | 0.01 mm |
| Penetration Accuracy | ±1 dmm |
| Standard Needle | 50 mm length, 2.5 g ±0.05 g |
| Standard Cone | 102.5 g ±0.05 g |
| Timing Options | 5, 8, 10, 12, 30, 60 s (±0.1 s tolerance) |
| Bath Type | Rigid borosilicate glass cylinder with magnetic stirrer |
| Power Supply | AC 220 V ±10%, 50 Hz, ≤300 W |
| Brand | MITONG (Shanghai Mitong Instrument Co., Ltd.) |
|---|---|
| Origin | Shanghai, China |
| Model | SYP-154E |
| Penetration Range | 0–650 Penetration Units (0.1 mm per unit) |
| Minimum Readout | 0.1 Penetration Unit |
| Resolution | 0.01 mm |
| Penetration Accuracy | ±1 Penetration Unit |
| Temperature Control Range | 0.00–50.00 °C (with ±0.1 °C stability) |
| Timing Accuracy | ±0.1 s (0–250 s programmable) |
| Displacement Sensor | Laser-based, 0–66 mm range, ±0.1 mm repeatability |
| Cone Assembly Mass | 37.5 g ±0.05 g (cone: 22.5 g ±0.025 g |
| rod | 15 g ±0.05 g) |
| Test Fixture | 200 mm diameter solid hemispherical PET support (Shore A hardness: 75–85) |
| Data Storage | 200 test records |
| Communication | RS-485 (MODBUS RTU), USB export |
| Brand | MITONG |
|---|---|
| Origin | Shanghai, China |
| Model | SYD-24521 |
| Compliance | GB/T 24521–2009 |
| Sample Chamber Internal Diameter | 16.3 ± 0.05 mm |
| Compaction Mass | 6 kg (main weight), 1 kg (auxiliary weight) |
| Standard Steel Column Diameter | Φ16.3 ± 0.03 mm |
| Sieve Apertures | 0.315 mm and 0.500 mm (100 mm diameter × 50 mm height) |
| Particle Size Ranges | 0.315–0.500 mm (Φ2.5 mm sieve), 0.500–1.000 mm (Φ4 mm sieve) |
| Leveling Sensitivity | 1 mm/m (200 mm spirit level) |