BrandMITONG (Shanghai Mitong Instrument Co., Ltd.)
OriginShanghai, China
ModelSYP-0595
Measurement Range0–650 Penetration Units (0.1 mm)
Minimum Readout0.1 Penetration Unit
Resolution0.01 mm
Penetration Accuracy±1 Penetration Unit
Timing Options5 s, 8 s, 10 s, 12 s, 30 s, 60 s (timing error < ±0.1 s)
Standard Cone Mass102.5 ± 0.05 g
Power SupplyAC 220 ± 10% V, 50 Hz, ≤300 W
Dimensions280 × 350 × 700 mm (L×W×H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG
OriginShanghai, China
ModelSYP-22459D
Penetration Range0–650 dmm (0.1 mm increments)
Minimum Readout0.1 dmm
Resolution0.01 mm
Penetration Accuracy±1 dmm
Temperature Control Range0.00–50.00 °C (±0.1 °C stability)
Timing Range0–250 s (±0.1 s accuracy)
LVDT Displacement Sensor0–66 mm range, ≤±0.1 mm repeatability
Standard Cone AssemblyTotal mass 102.5 g ±0.05 g, cone rod mass 47.5 g ±0.05 g (conforms to GB/T 22459.1–2008)
Data Storage200 test records
CommunicationRS-485 (MODBUS RTU), USB data export
Power Supply220 VAC ±10%, 50 Hz
Dimensions390 × 310 × 575 mm (L×W×H)
Net Weight12.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG
OriginShanghai, China
ModelSYP-0983H
Penetration Range0–650 dmm
Minimum Readout0.1 dmm
Resolution0.01 mm
Penetration Accuracy±1 dmm
Temperature Control Range0.00–50.00 °C
Temperature Stability±0.1 °C
Timing Range0–250 s
Timing Accuracy±0.1 s
LVDT Displacement Sensor Range0–66 mm
Displacement Resolution0.01 mm
Cone Mass (Type I)102.5 ± 0.05 g
Cone Rod Mass47.5 ± 0.05 g
Power Supply220 ± 10% VAC / 50 Hz
Net Weight12.5 kg
Dimensions (L×W×H)390 × 310 × 575 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandMITONG (Shanghai Mitong Instrument Co., Ltd.)
OriginShanghai, China
ModelSYP-154E
Penetration Range0–650 Penetration Units (0.1 mm per unit)
Minimum Readout0.1 Penetration Unit
Resolution0.01 mm
Penetration Accuracy±1 Penetration Unit
Temperature Control Range0.00–50.00 °C (with ±0.1 °C stability)
Timing Accuracy±0.1 s (0–250 s programmable)
Displacement SensorLaser-based, 0–66 mm range, ±0.1 mm repeatability
Cone Assembly Mass37.5 g ±0.05 g (cone: 22.5 g ±0.025 g
rod15 g ±0.05 g)
Test Fixture200 mm diameter solid hemispherical PET support (Shore A hardness: 75–85)