| Brand | Asahi Seiko |
|---|---|
| Origin | Japan |
| Model | EG01-6-1MR |
| Test Principle | Gurley-type differential pressure method |
| Measurement Units | Gurley seconds (s), air permeability [µm/(Pa·s)] |
| Accuracy | ±2% |
| Measurement Time | Up to 50× faster than conventional constant-volume methods |
| Pressure Source | 0.25 MPa (2.5 kgf/cm²) |
| Display | Red LED digital display |
| Timer Range | 0–999 s |
| Interface | RS-232C |
| Power Supply | AC 100–240 V, 50/60 Hz |
| Dimensions (W×D×H) | 320 × 520 × 520 mm |
| Net Weight | 20 kg |
| Compliance | JIS P 8117:2009 |
| Brand | ASECOS |
|---|---|
| Country of Origin | Germany |
| Model | Q90.195.120.FU.WDC |
| Fire Resistance Rating | 90 min (EN 14470-1 certified) |
| External Dimensions (W×D×H) | 1193 × 615 × 1953 mm |
| Internal Dimensions (W×D×H) | 1050 × 522 × 1647 mm |
| Door Opening Depth | 1165 mm |
| Net Weight | 424 kg |
| Maximum Uniform Load per Shelf | 150 kg |
| Total Load Capacity | 600 kg |
| Spill Containment Sump Capacity | 33 L |
| Exhaust Connection | DN 75 |
| Air Exchange Rate | 10×/h (9 m³/h) |
| Differential Pressure at 10× Air Exchange | 5 Pa |
| Floor-Level Adjustment Range | ±15 mm |
| Surface Finish | Cabinet Body RAL 7016 (Charcoal Grey), Door Options RAL 1004 (Safety Yellow) or RAL 7035 (Light Grey) |
| Door Mechanism | Dual-action self-closing with integrated hydraulic closing system |
| Locking | Cylindrical lock with status indicator (red/grey LED) |
| Compliance | EN 14470-1, EN 16121, EN 16122, FM Approval UL/ULC 1275, GS Mark, CE Mark |
| Brand | ASECOS |
|---|---|
| Origin | Germany |
| Model | Q90.195.120 / Q90.195.060 |
| Fire Resistance Rating | 90 min (EN 14470-1) |
| External Dimensions (W×D×H, mm) | 1193×615×1953 (Q90.195.120) / 599×615×1953 (Q90.195.060) |
| Internal Dimensions (W×D×H, mm) | 1050×522×1647 / 450×522×1647 |
| Net Weight | 424 kg / 265 kg |
| Spill Sump Capacity | 33 L / 22 L |
| Shelf Load Capacity (uniformly distributed) | 75 kg per shelf |
| Maximum Static Load | 600 kg |
| Air Extraction Connection | DN 75 |
| Air Exchange Rate | 10×/h (94 m³/h) |
| Pressure Differential at 10× Air Exchange | 55 Pa |
| Transport Base Entry Height | 90 mm |
| Transport Base Entry Width | 1120 mm / 526 mm |
| Color Options | Cabinet Body RAL 7016 (Charcoal Grey), Door Standard RAL 1004 (Warning Yellow) or RAL 7035 (Light Grey), plus 5 optional door colors (no surcharge) |
| Brand | ALPHA |
|---|---|
| Origin | USA |
| Model | AR5431P |
| Compatibility | ELTRA®, HORIBA® LECO®, Bruker® ONH analyzers |
| Packaging | 100 pcs per box |
| OEM Cross-Reference | ELTRA® 775-431, LECO® 775-431, HORIBA® 775-431, Bruker® 775-431 |
| Brand | Alpha Resources |
|---|---|
| Origin | USA |
| Model | AR433 |
| Compatibility | ELTRA®, HORIBA® LECO®, Bruker® ONH-p/D Series |
| Packaging | 50 pcs per box |
| OEM Cross-Reference | 90185775-433 |
| Brand | ADOLF KUHNER |
|---|---|
| Origin | Switzerland |
| Model | ISF1-Z |
| Instrument Type | Temperature-Controlled Orbital Shaking Incubator |
| Drive System | Direct-Drive DC Motor |
| Speed Range | 20–500 rpm (up to 700 rpm optional at select amplitudes) |
| Adjustable Amplitude | 3 / 6 / 9 / 12.5 / 19 / 25 / 50 / 70 mm (0–70 mm, continuously variable) |
| Temperature Range | Ambient +10°C to 80°C (lower limit down to –5°C with Peltier or compressor cooling) |
| Temperature Uniformity | < ±0.2°C at 37°C |
| Chamber Volume | 378 L |
| Chamber Material | Electropolished Stainless Steel (AISI 316L) |
| Humidity Control (optional) | 50–85% r.H. (EcoDew® system) |
| CO₂ Control (optional) | 0–20% v/v, IR sensor, ±0.4% abs accuracy at 5% CO₂ |
| Interface | Standard CAN-Bus |
| Power Supply | 230 V AC, 50/60 Hz |
| Max. Power Consumption | ~1000 W |
| Dimensions (L×D×H) | 1288 × 859 × 771 mm |
| Weight | 200–225 kg (model-dependent) |
| Brand | ADOLF KUHNER |
|---|---|
| Origin | Switzerland |
| Model | ISF4-X |
| Instrument Type | Temperature-Controlled Shaking Incubator |
| Speed Range | 20–500 rpm |
| Temperature Range | Ambient +10°C to 80°C (or –10°C to 80°C with compressor option) |
| Temperature Uniformity | ±0.3°C (at 37°C, across full shaker tray) |
| Chamber Volume | 1272 L |
| Power Consumption | <1700 W (standard), <2000–2600 W (with compressor & humidity) |
| Tray Dimensions | 800 × 420 mm |
| Max Load per Tray | 25 kg |
| Orbit Diameters | Ø12.5 mm, Ø25.0 mm, Ø50.0 mm (circular) |
| CO₂ Control | Optional (0–20% vol, NDIR sensor, ±0.4% accuracy at 5%) |
| Humidity Control | Optional (up to 85% r.h., capacitive sensor, ±2% r.h.) |
| Interface | CAN-bus (standard), USB/Ethernet (optional) |
| Lighting | 2 fluorescent lamps |
| Operating Languages | DE/FR/IT/EN/ES |
| Ambient Temp Range | 10–35°C |
| Brand | ADOLF KUHNER |
|---|---|
| Origin | Switzerland |
| Model | LT-X/XC |
| Instrument Type | Temperature-Controlled Orbital/Linear Shaking Incubator |
| Speed Range | 20–500 rpm |
| Speed Accuracy | ±0.5 rpm |
| Temperature Range | Ambient +10 °C to 80 °C (LT-XC: 5–60 °C with enhanced stability) |
| Chamber Volume | 260 L |
| Drive System | Brushless Magnetic Direct Drive |
| Oscillation Modes | Orbital (Ø12.5 / 25.0 / 50.0 mm), Linear (12.5 / 25.0 / 50.0 mm) |
| Temperature Uniformity | ±0.25 °C at 37 °C (across tray, LT-XC variant) |
| Humidity Control | Up to 85 % RH (optional) |
| CO₂ Control | 0–20 % (IR sensor, ±0.4 % accuracy at 5 % CO₂, standard on LT-XC) |
| O₂ Control | 0–20.9 % (zirconia sensor, optional) |
| Airflow | 160 m³/h |
| Power Supply | 220–240 V / 50–60 Hz |
| Weight | 170 kg |
| IP Rating | IP22 (splash-protected drive) |
| Warranty | 5-year manufacturer warranty |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Model | SU250 |
| Instrument Type | Upright Chamber |
| Temperature Range | −40 °C to +180 °C |
| Humidity Range | 10 % to 98 % RH |
| Temperature Uniformity | ≤ ±0.5 °C |
| Humidity Uniformity | ≤ ±3 % RH (at >75 % RH) / ≤ ±5 % RH (at ≤75 % RH) |
| Heating Rate | 3 °C/min |
| Internal Dimensions (W×D×H) | 600 × 600 × 700 mm |
| Compliance | IEC 60068-3-5, IEC 60068-3-6, EN 60068-2-1, EN 60068-2-2, EN 60068-2-14, EN 60068-2-30 |
| Brand | Otsuka Electronics |
|---|---|
| Origin | Japan |
| Model | RETS-100nx |
| Measurement Range (Retardation) | 0–60,000 nm |
| Wavelength Range | 400–800 nm (optional extensions available) |
| Retardation Repeatability (n=30) | ≤0.08 nm (quartz waveplate, ~600 nm) |
| Cell Gap Range | 0–600 µm (An=0.1) |
| Cell Gap Repeatability (n=30) | ≤0.005 µm (at ~3 µm gap, An=0.1) |
| Axis Detection Repeatability (n=30) | ≤0.08° |
| Spot Diameter | φ2 mm (standard) |
| Light Source | 100 W halogen lamp |
| Detector | Proprietary high-speed multichannel spectrometer (≈500 wavelength channels) |
| Standard Stage | 100×100 mm fixed platform |
| Optional Accessories | Motorized XY stage, tilt-rotary stage for Rth and 3D birefringence analysis, axis-angle compensation module |
| Brand | Hettich |
|---|---|
| Origin | Germany |
| Model | ROTIXA 500 RS |
| Type | Floor-standing Refrigerated Centrifuge |
| Max Speed | 11,500 rpm |
| Max RCF | 18,038 × g |
| Max Capacity | 4 × 1000 mL (horizontal rotor) |
| Temperature Range | −20 °C to +40 °C |
| Dimensions (W×D×H) | 650 × 814 × 973 mm |
| Weight | ~219 kg |
| Noise Level | 58 dB(A) |
| Power Supply | 230–240 V, 1~ |
| Power Consumption | 3,800 VA |
| EMC Compliance | EN/IEC 61326-1, Class B |
| [Brand | Alpha / ALPHA |
|---|---|
| Origin | USA |
| Model | AR3818F |
| Type | Low-carbon graphite crucible |
| Compatibility | LECO, HORIBA, ELTRA, Bruker ONH/O/N/H analyzers |
| Purity | <5 ppm C (typical), <10 ppm S (typical) |
| Dimensions | Ø25 mm × 35 mm (ID × height, nominal) |
| Max. Operating Temperature | 3,000 °C in inert atmosphere |
| Packaging | 10 pcs per sealed vacuum bag, 100 pcs per box] |
| Brand | Otsuka Electronics |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ELSZ-neo SE |
| Price | Upon Request |
| Particle Size Range | 0.6 nm – 10 µm |
| Temperature Control Range | 0–90 °C |
| Particle Sizing Method | Dynamic Light Scattering (Photon Correlation Spectroscopy) |
| Sample Concentration Range | Zeta Potential: 0.001–40% w/v |
| Particle Size | 0.00001% (0.1 ppm) – 40% w/v*¹ |
| Zeta Potential Measurement Range | No practical upper limit |
| Zeta Potential Principle | Electrophoretic Light Scattering (Laser Doppler Velocimetry) |
| Particle Size Principle | Dynamic Light Scattering (DLS) |
| Optical Configuration | Heterodyne for Zeta Potential |
| Light Source | Narrow-band Diode Laser |
| Detector | High-Sensitivity APD |
| Standard Cell | Flow-through Cell for Simultaneous Zeta & Size |
| Optional Accessories | Fluorescence Cut-off Filter, Flat-sample Electrode Cell for High-Salt Surface Zeta, Temperature Gradient Module |
| Power Supply | 100 V ±10%, 250 VA |
| Dimensions (W×D×H) | 330 × 565 × 245 mm |
| Weight | 22 kg |
| Brand | Dispermill |
|---|---|
| Origin | Netherlands |
| Model | Discovery 100 |
| Power | 0.75 kW (1.0 HP) |
| Speed Range | 0 – 12,000 rpm |
| Dispersion Disc Diameter | 70 mm |
| Torque | 1.3 N·m |
| Real-time Speed Display | Yes |
| Voltage/Frequency | 230 V, 50/60 Hz |
| Dimensions (D × W × H) | 485 × 501 × 991 mm |
| Net Weight | 55 kg |
| Container Capacity | 0.5 – 10 L |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | 500nano HR |
| Measurement Principle | Static image analysis with high-resolution CMOS imaging and collimated blue backlighting |
| Measurement Mode | Dry dispersion (integrated vacuum dispersion system) and reflective mode |
| Particle Size Range (dry) | 0.4–2000 µm |
| Pixel Resolution | 0.38–4.7 µm/pixel |
| Camera | 6.6 MP or 10 MP progressive-scan industrial CMOS |
| Optical System | Zoom telecentric lens |
| Light Source | 440 nm collimated blue LED |
| Field of View | 836 × 1140 µm @ 0.38 µm/pixel to 10266 × 1400 µm @ 4.7 µm/pixel |
| Software | Callisto 2D |
| Compliance Options | IQ/OQ/PQ validation support |
| Dimensions (W×D×H) | 540 × 540 × 720 mm (standard) |
| Weight | 38.5 kg / 43.5 kg |
| Brand | Lab Companion |
|---|---|
| Origin | South Korea |
| Model | IB-15G |
| Temperature Range | Ambient + 5°C to 70°C |
| Temperature Uniformity | ±0.1°C at 37°C |
| Chamber Volume | 102 L |
| Internal Dimensions | 480 × 410 × 520 mm |
| External Dimensions | 675 × 605 × 855 mm |
| Standard Shelving | 2 stainless steel wire shelves (max. 6) |
| Shelf Load Capacity | 30 kg per shelf |
| Net Weight | 55 kg |
| Heating Time to 37°C | 22 min |
| Temperature Recovery Time after Door Opening (at 37°C) | 2 min |
| Display Resolution | 0.1°C |
| Timer Range | 1 min – 99 h 59 min |
| Safety | Dual-stage overtemperature protection (patent KR 10-0397583), current overload protection, controller lockout, error code display with audible alarm |
| Compliance | Meets DIN 12880:2015 requirements for general-purpose incubators |
| Brand | JeioTech |
|---|---|
| Origin | South Korea |
| Model | TH-G-408 |
| Chamber Volume | 408 L |
| Temperature Range (dry) | −40 °C to +150 °C |
| Humidity Range | 25 %RH to 95 %RH |
| Temp. Uniformity (at 40 °C, 75 %RH) | ±0.5 °C |
| Temp. Stability (at 40 °C, 75 %RH) | ±0.3 °C |
| Humidity Stability (at 40 °C, 75 %RH) | ±0.4 %RH |
| Humidity Deviation (at 40 °C, 75 %RH) | ±3 %RH |
| Heating Rate | 2.6 °C/min |
| Internal Dimensions (W×D×H) | 600 × 850 × 800 mm |
| Standard Shelving | 2 adjustable stainless steel shelves (max. 10), load capacity per shelf: 25 kg, total payload: 65 kg |
| Water Tank Capacity | 15 L |
| Net Weight | 410 kg |
| Power Supply | 3-phase 380–415 VAC, 50/60 Hz |
| Compliance | DIN 12880, IEC 60068 |
| Brand | C&W |
|---|---|
| Origin | Netherlands |
| Model | CW1001 |
| Spray Method | Direct Air-Atomized Nozzle |
| Fog Output Rate | 1–2 mL/h |
| Nozzle Operating Pressure | 8.44 kg/cm² (≈120 psi) |
| Fog Collection Rate | 1–2 mL per 80 cm² per hour |
| Temperature Range | Ambient to 55 °C |
| Compliance | ASTM B117, ISO 9227, EN ISO 7253, DIN 50021, JIS Z 2371, SAE J2334, Ford CETP, GMW 14872, VW PV1210, BMW GS 90031, Renault D17 2025, etc. |
| [Brand | Alpha |
|---|---|
| Origin | USA |
| Model | AR008 |
| Type | High-Purity Combustion Flux for Inert Gas Fusion Analyzers |
| Compatibility | LECO, HORIBA, ELTRA, Bruker ONH/CS Instruments |
| Form | Granular |
| Purity | ≥99.95% (certified) |
| Packaging | Sealed 100 g or 500 g HDPE bottles under argon atmosphere |
| Storage | Dry, cool, inert environment |
| Safety | Non-hygroscopic, low volatility, compliant with OSHA and GHS handling guidelines] |