| Brand | ALPHA |
|---|---|
| Origin | USA |
| Model | AR5431P |
| Compatibility | ELTRA®, HORIBA® LECO®, Bruker® ONH analyzers |
| Packaging | 100 pcs per box |
| OEM Cross-Reference | ELTRA® 775-431, LECO® 775-431, HORIBA® 775-431, Bruker® 775-431 |
| Brand | Alpha Resources |
|---|---|
| Origin | USA |
| Model | AR433 |
| Compatibility | ELTRA®, HORIBA® LECO®, Bruker® ONH-p/D Series |
| Packaging | 50 pcs per box |
| OEM Cross-Reference | 90185775-433 |
| Brand | ACS |
|---|---|
| Origin | Italy |
| Model | SU250 |
| Instrument Type | Upright Chamber |
| Temperature Range | −40 °C to +180 °C |
| Humidity Range | 10 % to 98 % RH |
| Temperature Uniformity | ≤ ±0.5 °C |
| Humidity Uniformity | ≤ ±3 % RH (at >75 % RH) / ≤ ±5 % RH (at ≤75 % RH) |
| Heating Rate | 3 °C/min |
| Internal Dimensions (W×D×H) | 600 × 600 × 700 mm |
| Compliance | IEC 60068-3-5, IEC 60068-3-6, EN 60068-2-1, EN 60068-2-2, EN 60068-2-14, EN 60068-2-30 |
| [Brand | Alpha / ALPHA |
|---|---|
| Origin | USA |
| Model | AR3818F |
| Type | Low-carbon graphite crucible |
| Compatibility | LECO, HORIBA, ELTRA, Bruker ONH/O/N/H analyzers |
| Purity | <5 ppm C (typical), <10 ppm S (typical) |
| Dimensions | Ø25 mm × 35 mm (ID × height, nominal) |
| Max. Operating Temperature | 3,000 °C in inert atmosphere |
| Packaging | 10 pcs per sealed vacuum bag, 100 pcs per box] |
| Brand | Otsuka Electronics |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | ELSZ-neo SE |
| Price | Upon Request |
| Particle Size Range | 0.6 nm – 10 µm |
| Temperature Control Range | 0–90 °C |
| Particle Sizing Method | Dynamic Light Scattering (Photon Correlation Spectroscopy) |
| Sample Concentration Range | Zeta Potential: 0.001–40% w/v |
| Particle Size | 0.00001% (0.1 ppm) – 40% w/v*¹ |
| Zeta Potential Measurement Range | No practical upper limit |
| Zeta Potential Principle | Electrophoretic Light Scattering (Laser Doppler Velocimetry) |
| Particle Size Principle | Dynamic Light Scattering (DLS) |
| Optical Configuration | Heterodyne for Zeta Potential |
| Light Source | Narrow-band Diode Laser |
| Detector | High-Sensitivity APD |
| Standard Cell | Flow-through Cell for Simultaneous Zeta & Size |
| Optional Accessories | Fluorescence Cut-off Filter, Flat-sample Electrode Cell for High-Salt Surface Zeta, Temperature Gradient Module |
| Power Supply | 100 V ±10%, 250 VA |
| Dimensions (W×D×H) | 330 × 565 × 245 mm |
| Weight | 22 kg |
| Brand | Occhio |
|---|---|
| Origin | Belgium |
| Model | 500nano HR |
| Measurement Principle | Static image analysis with high-resolution CMOS imaging and collimated blue backlighting |
| Measurement Mode | Dry dispersion (integrated vacuum dispersion system) and reflective mode |
| Particle Size Range (dry) | 0.4–2000 µm |
| Pixel Resolution | 0.38–4.7 µm/pixel |
| Camera | 6.6 MP or 10 MP progressive-scan industrial CMOS |
| Optical System | Zoom telecentric lens |
| Light Source | 440 nm collimated blue LED |
| Field of View | 836 × 1140 µm @ 0.38 µm/pixel to 10266 × 1400 µm @ 4.7 µm/pixel |
| Software | Callisto 2D |
| Compliance Options | IQ/OQ/PQ validation support |
| Dimensions (W×D×H) | 540 × 540 × 720 mm (standard) |
| Weight | 38.5 kg / 43.5 kg |
| Brand | JeioTech |
|---|---|
| Origin | South Korea |
| Model | TH-G-408 |
| Chamber Volume | 408 L |
| Temperature Range (dry) | −40 °C to +150 °C |
| Humidity Range | 25 %RH to 95 %RH |
| Temp. Uniformity (at 40 °C, 75 %RH) | ±0.5 °C |
| Temp. Stability (at 40 °C, 75 %RH) | ±0.3 °C |
| Humidity Stability (at 40 °C, 75 %RH) | ±0.4 %RH |
| Humidity Deviation (at 40 °C, 75 %RH) | ±3 %RH |
| Heating Rate | 2.6 °C/min |
| Internal Dimensions (W×D×H) | 600 × 850 × 800 mm |
| Standard Shelving | 2 adjustable stainless steel shelves (max. 10), load capacity per shelf: 25 kg, total payload: 65 kg |
| Water Tank Capacity | 15 L |
| Net Weight | 410 kg |
| Power Supply | 3-phase 380–415 VAC, 50/60 Hz |
| Compliance | DIN 12880, IEC 60068 |
| Brand | C&W |
|---|---|
| Origin | Netherlands |
| Model | CW1001 |
| Spray Method | Direct Air-Atomized Nozzle |
| Fog Output Rate | 1–2 mL/h |
| Nozzle Operating Pressure | 8.44 kg/cm² (≈120 psi) |
| Fog Collection Rate | 1–2 mL per 80 cm² per hour |
| Temperature Range | Ambient to 55 °C |
| Compliance | ASTM B117, ISO 9227, EN ISO 7253, DIN 50021, JIS Z 2371, SAE J2334, Ford CETP, GMW 14872, VW PV1210, BMW GS 90031, Renault D17 2025, etc. |
| [Brand | Alpha |
|---|---|
| Origin | USA |
| Model | AR008 |
| Type | High-Purity Combustion Flux for Inert Gas Fusion Analyzers |
| Compatibility | LECO, HORIBA, ELTRA, Bruker ONH/CS Instruments |
| Form | Granular |
| Purity | ≥99.95% (certified) |
| Packaging | Sealed 100 g or 500 g HDPE bottles under argon atmosphere |
| Storage | Dry, cool, inert environment |
| Safety | Non-hygroscopic, low volatility, compliant with OSHA and GHS handling guidelines] |