ModelPY-1
Instrument TypeFixed-Position Capillary Viscometry Preparation System
Viscosity Range0.1–4.0 dL/g
Temperature Control Point30 °C
Temperature Stability±0.1 °C (typical for thermostatted capillary viscometry workflows)
ComplianceDesigned for ASTM D4603, ISO 1628-1, USP <911>, and GB/T 12005.1–1989 polymer intrinsic viscosity testing protocols
Software InterfaceTouchscreen HMI with audit trail logging (GLP-compliant event timestamps)
Power Supply220 V AC, 50 Hz
Dimensions320 × 280 × 360 mm
Weight12.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSRD NCY-X
Instrument TypeCapillary Viscometer
Viscosity Range0.1–1000 mPa·s
Configuration OptionsNCY-X/2, NCY-X/4, NCY-X/6 (2/4/6 parallel capillary units)
Temperature Stability±0.01 °C long-term uniformity (JWC precision thermostatic bath)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
ModelRL-Z1B1
OriginShanghai, China
Power Supply198–242 V AC, 50 Hz, 3 A
Temperature Control Range100–400 °C
Temperature Display Accuracy< ±0.1 °C
8-h Thermal Stability< ±0.10 °C
Temperature Recovery Time≤ 4 min
Standard Die Orifice DiametersΦ2.095 ± 0.005 mm and Φ1.18 ± 0.01 mm
Standard Load Masses325, 1200, 2160, 3800, 5000, 10000, 12500, 21600 g
MFR/MVR Measurement Range0.01–9999 g/10 min (automated)
Sample CompatibilityThermoplastics including PE, PP, PC, PA, PS, POM, ABS, PMMA, cellulose esters, fluoropolymers (e.g., F46)
Cutting ModeMicroprocessor-controlled automatic timer-based extrudate cutting
Data OutputIntegrated thermal printer with MFR, MVR, melt density (ρ), test duration, and calibration metadata
Dimensions (W×D×H)520 × 380 × 730 mm
Net WeightMain Unit 40 kg, Weight Set 22 kg
ComplianceASTM D1238, ISO 1133-1 & ISO 1133-2, GB/T 3682.1–2018, GB/T 3682.2–2018
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSRD NCY-S Series Automated Capillary Viscometer
Instrument TypeFixed-Position Capillary Viscometer
Operating EnvironmentAmbient Temperature
Viscosity Range0.1–1000 mPa·s
Temperature Range0–75 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C
ComplianceASTM D445, ISO 3104, GB/T 265, USP <911>
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
ModelSWB-300C
Temperature RangeAmbient to 300 °C
Heating Rate5 ± 0.5 °C/6 min or 12 ± 1.0 °C/6 min
Temperature Accuracy±0.5 °C
Temperature Uniformity±0.5 °C across 3 sensing points
Bath Volume25 L
Test Stations3
Displacement Resolution0.01 mm
Vicat Needle Cross-Section1.000 ± 0.015 mm² (d = 1.128 ± 0.0085 mm)
HDT Probe RadiusR = 3.0 ± 0.2 mm
HDT Support Span100 ± 0.5 mm
Load Rod Mass88.35 g
Max. Thermal Expansion of Fixture≤0.01 mm (automatically compensated)
Heating Power4 kW
Power Supply220 VAC, 20 A
Dimensions (L×W×H)830 × 500 × 540 mm
Net Weight (C-type)58 kg (excl. heat transfer oil)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
ModelHRC
Instrument TypeConstant-Temperature Heating Bath
Number of Sample Positions24 (arranged in 4 zones × 6 positions)
Temperature RangeAmbient to 135 °C
Temperature Stability±1 °C
Vessel CompatibilityStandard Glass Vials with Magnetic Stir Bars
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSF-2
PriceUSD 1,950 (approx.)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSierda/SRD
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelNCY
Instrument TypeFixed-Position Capillary Viscometer
Operating EnvironmentAmbient Temperature
Viscosity Range0.4–1.5 dL/g (intrinsic viscosity)
Temperature Range5–75 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
ModelNWC-G
Instrument TypeFixed-Station Capillary Viscometer with Integrated Thermostatic Bath
Temperature Range50–150 °C
Temperature Resolution0.01 °C
Temperature Stability±0.01–±0.03 °C (medium-dependent)
ComplianceASTM D445, ISO 3104, JIS K 2283, GB/T 265
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
ModelNCY Series
TypeFixed-Position Automated Capillary Viscometer
OriginShanghai, China
Viscosity Timing Range0.01–999.99 s
Temperature Range5–80 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C
Temperature Uniformity±0.01 °C
Timing Resolution0.01 s
Intrinsic Viscosity Range0.1–4.0 dL/g (typical: 0.5–1.5 dL/g)
Average Degree of Polymerization100–10,000 (typical: ~1,200)
Dynamic Viscosity5–800 mPa·s (typical: 100–300 mPa·s)
Kinematic Viscosity0.1–300 mm²/s
Heating Power1 kW
Cooling Capacity125/220 kcal/h
Power Supply220 V, 6–10 A
Configurable Test Units2–6 parallel capillary stations
Preloaded Calculation Formulas10 standard polymer-specific algorithms (e.g., Huggins, Kraemer, Schulz-Blaschke)
ComplianceDesigned for ASTM D4603, ISO 1628-1/3, GB/T 17931, GB/T 14189, USP <911>
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
ModelRL-Z1B1+
Temperature Range100–400 °C
Temp. Accuracy±0.2 °C (125–300 °C)
Temp. Stability≤±0.1 °C (8-h drift ≤0.1 °C)
Barrel ID9.550 ±0.020 mm
Die ID2.095 ±0.005 mm
Load Accuracy±0.5%
Standard Loads325 g to 21,600 g
MFR Range0.02–2000 g/10 min
MVR Range0.03–50000 cm³/10 min
Timing Resolution0.001 s
Auto-Cut Interval0–999 s
ComplianceISO 1133:1997(E), ASTM D1238-95, GB/T 3682-2000, JJG 878, JIS K 7210
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
ModelJWC-52B1
Instrument TypeCirculating Constant-Temperature Bath
Circulation ModeInternal Circulation
Temperature ControlRefrigeration & Heating
Bath Volume30 L
Temperature Range0–70 °C
Temperature Stability±0.01 °C
Temperature Resolution0.01 °C
Temperature Uniformity±0.01 °C (within ambient ±30 °C)
Refrigeration Capacity220 kcal/h
Heating Power1 kW
Power Supply220 V, 10 A, 50 Hz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
ModelSF-1
Measurement PrincipleDifferential Pressure (Manometric) Method
Temperature Control RangeAmbient to 250 °C
Temperature Stability±2.0 °C
Vacuum Level≤100 Pa
Moisture Detection Range5–3000 ppm (sample mass: 0.5–10 g)
Power Supply220 V AC, 2 A
ComplianceISO 6188:1980 (Plastics — Poly(ethylene terephthalate) granules — Determination of water content)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelZ1B1
PriceUSD 4,950 (FOB Shanghai)
Temperature Control Range100–400 °C
Temperature Display Accuracy< 0.1 °C
8-h Thermal Stability< 0.10 °C
Temperature Recovery Time≤ 4 min
Standard Load Masses325, 1200, 2160, 3800, 5000, 10000, 12500, 21600 g
Die Orifice DiametersΦ2.095 ± 0.005 mm and Φ1.18 ± 0.01 mm
Power Supply198–242 V AC, 50 Hz, 3 A
Dimensions (W×D×H)520 × 380 × 730 mm
Net WeightMain Unit 40 kg, Weight Kit 22 kg
Measuring Range0.01–9999 g/10 min (MFR, automatic mode)
ComplianceASTM D1238, ISO 1133-1 & ISO 1133-2, GB/T 3682.1–2018
Sample CompatibilityThermoplastics including PE, PP, PC, PA, PS, POM, ABS, PMMA, cellulose esters, fluoropolymers (e.g., FEP, F46)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
ModelNWC-4
Instrument TypeCapillary Viscometer System
Viscosity Measurement Range0.01–999.99 s (efflux time)
Temperature Control Range0–80 °C
Temperature Resolution0.01 °C
Temperature Stability±0.01 °C (within ambient ±30 °C)
Temperature Uniformity±0.01 °C (within bath volume)
Timing Range0–999.99 s
Timing Resolution0.01 s
Timing Accuracy±0.2 s per 999 s
Bath Volume42 L
Bath Chamber Dimensions640 × 195 × 340 mm (L×W×H)
Observation Window475 × 270 mm
Heating Power1 kW
Refrigeration Unit (XWC-100/1)Cooling Capacity: 250 kcal/h
Minimum Output Temperature<−15 °C (short-circuit condition)
Power SupplyMain Unit: 220 V, 6 A, 50 Hz
Chiller220 V, 3 A, 50 Hz
ConstructionPowder-coated steel chassis with stainless-steel front panel
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
ModelRL-Z1B1-
Temperature Control Range100–400 °C
Temperature Display Accuracy< 0.1 °C
8-Hour Temperature Stability< 0.10 °C
Temperature Recovery Time≤ 4 min
Standard Die Orifice DiametersΦ2.095 ± 0.005 mm and Φ1.18 ± 0.01 mm
Available Test Loads325, 1200, 2160, 3800, 5000, 10000, 12500, 21600 g
MFR Measurement Range0.01–9999 g/10 min (automatic mode)
Power Supply198–242 V AC, 50 Hz, 3 A
Dimensions (W×D×H)520 × 380 × 730 mm
Net WeightMain Unit 40 kg, Weight Set 22 kg
ComplianceASTM D1238, ISO 1133, GB/T 3682
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSRD RL-Z1B1
PriceUSD 5,750 (FOB Shanghai)
Temperature Control Range100–400 °C
Temperature Display Accuracy< 0.1 °C
8-h Thermal Stability< 0.10 °C
Temperature Recovery Time≤ 4 min
Standard Load Masses325, 1200, 2160, 3800, 5000, 10000, 12500, 21600 g
Die Orifice DiametersΦ2.095 ± 0.005 mm and Φ1.18 ± 0.01 mm
Power Supply198–242 V AC, 50 Hz, 3 A
Dimensions (W×D×H)520 × 380 × 730 mm
Net WeightMain Unit 40 kg, Weight Set 22 kg
Measuring Range0.01–9999 g/10 min (auto mode)
ComplianceASTM D1238, ISO 1133-1 & ISO 1133-2, GB/T 3682.1–2018, GB/T 3682.2–2018
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
ModelRL-11B1
Temperature Control Range100–400 °C
Temperature Display Accuracy< 0.2 °C
8-Hour Temperature Stability< 0.1 °C
Temperature Recovery Time≤ 4 min
Timing Range0–999.9 s & 0–9999 s
Standard Die DimensionsΦ2.095 ± 0.005 mm & Φ1.180 ± 0.010 mm
Load Options325 g, 2160 g, 5000 g (standard configuration)
MFR/MVR Measurement Range0.01–9999 g/10 min (automated mode)
ComplianceGB/T 3682–2000, ISO 1133:1997(E), JIS K7210
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelJWC-32C1
Instrument TypeCirculating Constant-Temperature Bath
Circulation ModeExternal Circulation
Temperature ControlRefrigeration & Heating
Bath Volume42 L
Temperature Range0–80 °C
Temperature Stability±0.01 °C
Temperature Resolution0.01 °C
Heating Power1 kW
Cooling Capacity220 kcal/h
Cold Source Output Temp (short-circuit)–15 °C
Input Voltage220 V AC, 50 Hz
Dimensions (Bath Unit)75 × 26/38 (with/without backlight box) × 61 cm (L×W×H)
Internal Chamber64 × 19.5 × 34 cm (L×W×H)
Viewing Window47.5 × 27 cm (L×H)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
ModelNCY-2
TypeFixed-Position Automated Capillary Viscometer
Viscosity Range (Efflux Time)0.01–999.99 s
Temperature Range5–75 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C
Timing Resolution0.01 s
Timing Range0.01–999.99 s
Measured ParametersIntrinsic Viscosity (0.1–4.0 dL/g), Average Polymerization Degree (100–10,000), Kinematic Viscosity (0.1–300 mm²/s), Dynamic Viscosity (5–800 mPa·s)
Heating Power1 kW
Cooling Capacity125/220 kcal/h
Power Supply220 V AC, 6–10 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
ModelLB-100
Application ScopePolymer Processing Simulation (Compounding, Extrusion, Molding)
Core FunctionReal-time Torque, Temperature & Pressure Monitoring During Dynamic Shear Processing
Measurement PrincipleCouette-type Rotational Rheometry with Intensified Shear History Simulation
Compliance ContextDesigned for ASTM D3835, ISO 11443, ISO 25577, and GLP-aligned R&D workflows
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
ModelSWB-300A/B
Temperature RangeAmbient to 300 °C
Heating Rate Options5 ± 0.5 °C/6 min or 12 ± 1.0 °C/6 min
Temperature Accuracy±0.5 °C
Temperature Uniformity±0.5 °C across bath
Bath Volume25 L
Test Stations3
Deformation MeasurementDial Gauge (0.01 mm resolution)
HDT Indenter RadiusR = 3.0 ± 0.2 mm
HDT Span Length100 ± 0.5 mm
Load Rod Mass88.35 g
Vicat Needle Cross-Sectional Area1.000 ± 0.015 mm² (d = 1.128 ± 0.0085 mm)
Thermal Expansion of Test Frame≤ 0.01 mm (with correction value provided if exceeded)
Heating Power4 kW
Power Supply220 VAC, 20 A
Dimensions (L×W×H)830 × 500 × 540 mm
Net WeightSWB-300A — 58 kg
Optional FeatureMotorized Lift Mechanism (SWB-300B only)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
ModelNCY-PET
Viscosity Range0.01–999.99 mPa·s
Temperature Range5–75 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C
Timing Range0.01–999.99 s
Timing Resolution0.01 s
Inherent Viscosity Range0.1–4.0 dL/g
Average Degree of Polymerization100–10,000
Kinematic Viscosity Range0.1–300 mm²/s
Thermal Stability±0.01 °C (uniformity & fluctuation)
Power Supply220 V AC, 6–10 A
Heating Capacity1 kW
Cooling Capacity125/220 kcal/h
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSierda
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (PRC)
ModelNCY-C1
Instrument CategoryCapillary Viscometer Accessory
Mounting TypeFixed-Station Integrated Unit
Operating EnvironmentAmbient Temperature
Compatible HostNCY Series Automatic Capillary Viscometers
Temperature Control Range0–80 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C
Show next
InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0