BrandSRD
OriginShanghai, China
ModelPY-1
Instrument TypeFixed-Position Capillary Viscometry Preparation System
Viscosity Range0.1–4.0 dL/g
Temperature Control Point30 °C
Temperature Stability±0.1 °C (typical for thermostatted capillary viscometry workflows)
ComplianceDesigned for ASTM D4603, ISO 1628-1, USP <911>, and GB/T 12005.1–1989 polymer intrinsic viscosity testing protocols
Software InterfaceTouchscreen HMI with audit trail logging (GLP-compliant event timestamps)
Power Supply220 V AC, 50 Hz
Dimensions320 × 280 × 360 mm
Weight12.5 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSRD NCY-X
Instrument TypeCapillary Viscometer
Viscosity Range0.1–1000 mPa·s
Configuration OptionsNCY-X/2, NCY-X/4, NCY-X/6 (2/4/6 parallel capillary units)
Temperature Stability±0.01 °C long-term uniformity (JWC precision thermostatic bath)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelSRD NCY-S Series Automated Capillary Viscometer
Instrument TypeFixed-Position Capillary Viscometer
Operating EnvironmentAmbient Temperature
Viscosity Range0.1–1000 mPa·s
Temperature Range0–75 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C
ComplianceASTM D445, ISO 3104, GB/T 265, USP <911>
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSierda/SRD
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (China)
ModelNCY
Instrument TypeFixed-Position Capillary Viscometer
Operating EnvironmentAmbient Temperature
Viscosity Range0.4–1.5 dL/g (intrinsic viscosity)
Temperature Range5–75 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
ModelNWC-G
Instrument TypeFixed-Station Capillary Viscometer with Integrated Thermostatic Bath
Temperature Range50–150 °C
Temperature Resolution0.01 °C
Temperature Stability±0.01–±0.03 °C (medium-dependent)
ComplianceASTM D445, ISO 3104, JIS K 2283, GB/T 265
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
ModelNCY Series
TypeFixed-Position Automated Capillary Viscometer
OriginShanghai, China
Viscosity Timing Range0.01–999.99 s
Temperature Range5–80 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C
Temperature Uniformity±0.01 °C
Timing Resolution0.01 s
Intrinsic Viscosity Range0.1–4.0 dL/g (typical: 0.5–1.5 dL/g)
Average Degree of Polymerization100–10,000 (typical: ~1,200)
Dynamic Viscosity5–800 mPa·s (typical: 100–300 mPa·s)
Kinematic Viscosity0.1–300 mm²/s
Heating Power1 kW
Cooling Capacity125/220 kcal/h
Power Supply220 V, 6–10 A
Configurable Test Units2–6 parallel capillary stations
Preloaded Calculation Formulas10 standard polymer-specific algorithms (e.g., Huggins, Kraemer, Schulz-Blaschke)
ComplianceDesigned for ASTM D4603, ISO 1628-1/3, GB/T 17931, GB/T 14189, USP <911>
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
ModelNWC-4
Instrument TypeCapillary Viscometer System
Viscosity Measurement Range0.01–999.99 s (efflux time)
Temperature Control Range0–80 °C
Temperature Resolution0.01 °C
Temperature Stability±0.01 °C (within ambient ±30 °C)
Temperature Uniformity±0.01 °C (within bath volume)
Timing Range0–999.99 s
Timing Resolution0.01 s
Timing Accuracy±0.2 s per 999 s
Bath Volume42 L
Bath Chamber Dimensions640 × 195 × 340 mm (L×W×H)
Observation Window475 × 270 mm
Heating Power1 kW
Refrigeration Unit (XWC-100/1)Cooling Capacity: 250 kcal/h
Minimum Output Temperature<−15 °C (short-circuit condition)
Power SupplyMain Unit: 220 V, 6 A, 50 Hz
Chiller220 V, 3 A, 50 Hz
ConstructionPowder-coated steel chassis with stainless-steel front panel
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
ModelNCY-2
TypeFixed-Position Automated Capillary Viscometer
Viscosity Range (Efflux Time)0.01–999.99 s
Temperature Range5–75 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C
Timing Resolution0.01 s
Timing Range0.01–999.99 s
Measured ParametersIntrinsic Viscosity (0.1–4.0 dL/g), Average Polymerization Degree (100–10,000), Kinematic Viscosity (0.1–300 mm²/s), Dynamic Viscosity (5–800 mPa·s)
Heating Power1 kW
Cooling Capacity125/220 kcal/h
Power Supply220 V AC, 6–10 A
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSRD
OriginShanghai, China
ModelNCY-PET
Viscosity Range0.01–999.99 mPa·s
Temperature Range5–75 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C
Timing Range0.01–999.99 s
Timing Resolution0.01 s
Inherent Viscosity Range0.1–4.0 dL/g
Average Degree of Polymerization100–10,000
Kinematic Viscosity Range0.1–300 mm²/s
Thermal Stability±0.01 °C (uniformity & fluctuation)
Power Supply220 V AC, 6–10 A
Heating Capacity1 kW
Cooling Capacity125/220 kcal/h
Added to wishlistRemoved from wishlist 0
Add to compare
BrandSierda
OriginShanghai, China
Manufacturer TypeAuthorized Distributor
Regional ClassificationDomestic (PRC)
ModelNCY-C1
Instrument CategoryCapillary Viscometer Accessory
Mounting TypeFixed-Station Integrated Unit
Operating EnvironmentAmbient Temperature
Compatible HostNCY Series Automatic Capillary Viscometers
Temperature Control Range0–80 °C
Temperature Resolution0.01 °C
Temperature Accuracy±0.01 °C