- All
- Favorite
- Popular
- Most rated
| Brand | A&D |
|---|---|
| Origin | Japan |
| Model | MS-70 |
| Heating Source | 400 W Halogen Lamp |
| Weighing Range | 71 g |
| Readability | 0.0001 g |
| Moisture Content Resolution | 0.001 % / 0.01 % / 0.1 % |
| Temperature Range | 30–200 °C |
| Sample Pan Diameter | 85 mm |
| Dimensions (W×D×H) | 215 × 320 × 173 mm |
| Weight | 6.0 kg |
| Compliance | GLP/GMP/ISO-compliant data logging, RS-232 interface, WinCT-Moisture software support |
| Brand | A&D |
|---|---|
| Origin | Shanghai, China (Imported Japanese Design & Core Technology) |
| Heating Source | 400 W Halogen Lamp |
| Weighing Range | 51 g |
| Readability | 0.002 g |
| Moisture Content Accuracy | ±0.05 % / ±0.1 % / ±1.0 % (depending on sample mass and drying behavior) |
| Temperature Range | 50–200 °C |
| Sample Pan Diameter | 85 mm |
| Dimensions (W×D×H) | 215 × 320 × 173 mm |
| Weight | ~6.0 kg |
| Measurement Modes | Standard, Automatic, Timed, Manual |
| Drying Programs | Standard, Ramp, Step, Rapid |
| Data Storage | 10 measurement methods, 50 result records |
| Interface | RS-232 serial port |
| Compliance | GLP/GMP/ISO-compliant data logging with timestamp, operator ID, calibration history, and audit trail capability |
| Brand | A&D |
|---|---|
| Model | MX-50 |
| Heating Source | 400 W Halogen Lamp |
| Weighing Range | 51 g |
| Readability | 0.001 g |
| Moisture Content Resolution | 0.01 % / 0.1 % |
| Temperature Range | 50–200 °C |
| Display | Fluorescent LCD |
| Interface | RS-232 |
| Compliance | GLP/GMP/ISO |
| Software | WinCT-Moisture (PC-Connected) |
| Sample Compatibility | Solids, Powders, Granules, Pastes, Liquids |
| Calibration Standard | Disodium Tartrate Dihydrate (15.66 % ± 0.3/−0.1 % H₂O) |
| Brand | Peiou |
|---|---|
| Origin | Shanghai, China |
| Model | SKD-100 |
| Instrument Type | Kjeldahl Nitrogen Determinator |
| Automation Level | Semi-Automated |
| Nitrogen Determination Range | 0.1–240 mg N |
| Sample Weight Capacity | ≤5 g (solid) / ≤15 mL (liquid) per sample |
| Alkali/Acid Addition Time Control | 0–99 s (segmented) |
| Distillation Time Setting | 0–99 min |
| Distillation Rate | 14–28 mL/min |
| Power Adjustment Range | 750–1500 W |
| Recovery Rate | >99.5% |
| Repeatability | RSD ≤0.5% |
| Dimensions (L×W×H) | 370×300×680 mm |
| Net Weight | 15 kg |
| Display | LED digital |
| Data Storage | 10 programmable distillation/alkali addition methods |
| Safety Features | Real-time liquid level monitoring, overpressure protection, dry-run prevention, emergency stop |
| Housing Material | Molded ABS engineering plastic (acid/alkali resistant) |
| Tubing | PEIU proprietary corrosion-resistant high-temp tubing |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Water Supply Requirement | ≥0.15 MPa pressure, ≤20 °C inlet temperature |
Show next