- All
- Favorite
- Popular
- Most rated
| Brand | ADInstruments (YUYANBIO is distributor, not manufacturer) |
|---|---|
| Origin | New Zealand |
| Manufacturer | ADInstruments Ltd. |
| Country of Manufacture | New Zealand |
| Model | PowerLab 35 |
| Input Sampling Rate | Up to 200 kS/s per channel (400 kS/s total) |
| ADC Resolution | 16-bit |
| Input Range | 2 mV–10 V (12 ranges) |
| Input Impedance | ~1 MΩ |
| Input Noise | <1 µVrms |
| Low-Pass Filter | 1 Hz–25 kHz (standard stepped settings) |
| Coupling | DC or AC (0.15 Hz cutoff) |
| Analog Output | 16-bit, ±10 V range, 50 mA max current |
| Trigger Input Threshold | 1.3 V (rising), 1.1 V (falling) |
| Dimensions (W×H×D) | 240 × 70 × 260 mm |
| Power Supply | 90–250 VAC, 50/60 Hz |
| Brand | ADInstruments (YUYANBIO distributed) |
|---|---|
| Country of Origin | New Zealand |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | PowerLab 35 Series |
| Price Range | USD 10,500 – 19,800 (FOB NZD equivalent) |
| Max Sampling Rate | 200 kS/s per channel (400 kS/s aggregate) |
| ADC Resolution | 16-bit |
| Input Voltage Range | ±2 mV to ±10 V (12 ranges) |
| Input Impedance | ~1 MΩ |
| Input Noise | <1 µVrms |
| Low-Pass Filter | 1 Hz–25 kHz (logarithmic step selection) |
| AC Coupling | DC or 0.15 Hz (software-selectable) |
| Analog Output | 16-bit, ±200 mV to ±10 V (6 ranges), 50 mA max drive |
| Trigger Threshold | +1.3 V (rising), +1.1 V (falling) |
| Dimensions (W×H×D) | 240 × 70 × 260 mm |
| Power Supply | 90–250 VAC, 50/60 Hz |
| Brand | ActiGraph |
|---|---|
| Origin | USA |
| Model | wGT3X-BT |
| Sensor Type | Tri-axial accelerometer (±6 g range) |
| Sampling Rate | 10–100 Hz configurable |
| Memory Capacity | 28 days @ 30-s epochs, 14 days @ 15-s epochs, 7 days @ 5-s epochs |
| Battery Life | Up to 30 days (typical use) |
| Connectivity | Bluetooth® Smart (BLE 4.0) |
| Water Resistance | IP67 rated |
| Dimensions | 4.3 × 3.3 × 1.3 cm |
| Weight | 14 g |
| Compatible Software | ActiLife v6.8.1+ |
| Data Output Formats | CSV, TXT, AGD |
| Compliance | FDA-listed device (Class II), ISO 13485-manufactured, GLP-supportive audit trail in ActiLife |
| Key | Brand: Thermal Technology |
|---|---|
| Model | NTE-2A |
| Temperature Range | 0–50 °C |
| Control Accuracy | ±0.1 °C |
| Resolution | 0.1 °C |
| Probe Tip Diameter | 13 mm |
| Probe Length | 16.5 cm |
| Response Time (Heating/Cooling) | <4 s |
| Base Temperature Adjustment Range | 20–30 °C |
| Input Power | 200–240 V AC, 50 Hz, 100 W |
| Dimensions | 20.3 × 17.8 × 38.1 cm |
| Weight | 12.7 kg |
| Compliance | ASTM F2696 (Standard Guide for Quantitative Sensory Testing), ISO 13485 (Medical Devices), FDA 21 CFR Part 11 (Software Validation Ready) |
| Brand | YUYANBIO |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Medical Device |
| Model | e-Celsius® Human Core Temperature Telemetry System |
| Pricing | Available Upon Request |
| Brand | YUYANBIO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YAN-505A |
| Testing Speed | 100 samples/hour |
| Sample Volume | 10 µL (whole blood, pre-diluted mode) |
| Sample Type | Whole Blood |
| Loading Mode | Automatic |
| White Blood Cell Differential Method | Multi-angle semiconductor laser scattering flow cytometry |
| Output Graphics | 3 histograms + 4 scatter plots (including dedicated BASO scatter plot) |
| Internal Storage Capacity | Up to 50,000 complete test records with graphical data |
| Display | 10.4-inch full-color capacitive touchscreen |
| LIS Connectivity | Bidirectional wireless LIS interface compliant with ASTM E1384 and HL7 v2.x |
| Regulatory Compliance | Designed for GLP-compliant preclinical research environments |
| Optional Module | Reticulocyte detection (YAN-505A variant only) |
| Brand | YUYANBIO |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Country of Origin | China |
| Model | YAN-105A |
| Price Range | USD 4,200 – 12,600 (FOB) |
| Throughput | 100 samples/hour |
| Sample Volume | 17 µL (whole blood mode) |
| Sample Type | Whole blood (native or pre-diluted) |
| Loading Mode | Fully automated aspiration and processing |
| Detection Principle | Coulter impedance + non-cyanide colorimetric hemoglobin assay |
| Output | 3-parameter histogram (WBC, RBC, PLT), integrated thermal printer, 50,000-sample onboard storage |
Show next