Empowering Scientific Discovery

Shanghai Ziqi Experimental Equipment Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
OriginShanghai, China
ModelYC-80
Capacity80 L
Temperature Range2–8°C
Internal Dimensions360 × 400 × 680 mm
External Dimensions472 × 500 × 870 mm
Power Consumption150 W
Rated Voltage/Frequency220 V / 50 Hz
Net Weight30.5 kg
Gross Weight34 kg
Shelving3 adjustable wire shelves
Compressor & FanInternational brand compressor + EBM high-efficiency DC fan motor
Temperature Display Resolution0.1°C
Alarm SystemDual-mode (audible + visual), remote alarm output, battery-backed temperature logging during power outage
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
OriginShanghai, China
ModelDW-86W102
Capacity102 L
Internal Dimensions (mm)450 × 430 × 540
External Dimensions (mm)1125 × 765 × 890
Power Supply220 V / 50 Hz
Rated Power558 W
Temperature Range−40 °C to −86 °C
ConfigurationHorizontal (top-opening)
InsulationHigh-density polyurethane foam, dual-door sealing system
CompressorImported high-efficiency cascade compressor
Fan MotorEBM precision AC fan motor
RefrigerantEnvironmentally compliant non-CFC/non-HCFC blend
ComplianceDesigned per IEC 61000-6-3 (EMC), GB/T 20154–2014 (Chinese ULT freezer standard), GLP-ready architecture
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
OriginShanghai, China
ModelDW-40L206
Capacity206 L
Interior Dimensions (mm)506 × 451 × 1007
Exterior Dimensions (mm)717 × 656 × 1543
Power Supply220 V / 50 Hz
Rated Power210 W
Temperature Range–10 °C to –40 °C
Cabinet TypeUpright, Side-Opening
InsulationHigh-density polyurethane foam with microcellular structure
RefrigerantEco-friendly, non-CFC/HCFC-free blend
CompressorImported high-efficiency compressor
Fan MotorEBM premium AC fan motor
Door SealDual-gasket sealing system
DisplayLED digital temperature display on door
Safety FeaturesAudible/visual high-low temperature alarm, keypad lock, delayed start, compressor protection interval, remote alarm interface
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAUCMA
OriginShanghai, China
ModelDW-25W147
Capacity147 L
Interior Dimensions (mm)599 × 389 × 677
Exterior Dimensions (mm)739 × 564 × 837
Temperature Range–10 °C to –25 °C
Power Supply220 V / 50 Hz
Rated Power87 W
Cabinet TypeHorizontal (Top-Opening)
InsulationCFC-free polyurethane foam with microcellular structure
RefrigerantR134a (non-ozone-depleting)
CompressorHigh-efficiency sealed rotary compressor
Control SystemMicroprocessor-based digital temperature controller with dual-stage alarm logic
Safety FeaturesAudible/visual high-low temperature alarm, sensor fault detection, keypad lock, compressor delay protection, pressure equalization valve
ComplianceDesigned per IEC 61000-6-3 (EMC), GB/T 20154–2014 (Chinese standard for low-temperature cabinets), and aligned with general requirements of ISO 13485 for medical device storage environments
Added to wishlistRemoved from wishlist 0
Add to compare
BrandYiheng
OriginShanghai, China
Heating MethodSix-Side Direct Heating
Air CirculationForced Convection
Control SystemDigital PID Temperature Control
Temperature RangeRT + 5°C to 80°C
Temperature Resolution0.1°C
Temperature Fluctuation±0.2°C
Temperature Uniformity±1.5°C at 37°C
Chamber Capacity42 L
External Dimensions (W×D×H)505 × 635 × 600 mm
Power Consumption250 W
Standard Shelving2 adjustable stainless steel shelves
Inner Chamber MaterialMirror-Finish Stainless Steel
Observation WindowNot equipped
Test PortØ25 mm on left side
Safety FeaturesIndependent Over-Temperature Alarm with visual/audible alert
Optional AccessoriesMulti-segment programmable controller, embedded thermal printer, RS485 communication interface with PC software, USB data export (U-disk), UV germicidal lamp
Added to wishlistRemoved from wishlist 0
Add to compare
BrandZiQi
OriginShanghai, China
Manufacturer TypeDirect Manufacturer
Region of OriginDomestic (China)
ModelZQMO-2
Display TypeDigital Control Panel
FunctionTemperature-Controlled Oscillation
Speed Range100–1200 rpm
Orbit Diameter2 mm
Capacity2 standard microplates (e.g., 96-well or 384-well plates)
Time Setting Range1 min – 99 h 59 min
Temperature RangeAmbient +5°C to 70°C
Temperature Accuracy≤ ±0.5°C
Temperature Uniformity≤ ±0.5°C
Heating Rate≤20 min (from ambient to 70°C)
Speed Resolution1 rpm
Power SupplyAC 100–230 V, 50–60 Hz, 120 W
Dimensions (W×D×H)270 × 300 × 158 mm
Weight6.3 kg
Show next