Empowering Scientific Discovery

Shenzhen Yizheng Technology Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAMS Alliance
OriginItaly
ModelSmartchem 450
Sample ThroughputUp to 450 samples/hour (colorimetric), 150 samples/hour (ISE)
Reaction Temperature Range30–50 °C (adjustable, ±0.1 °C accuracy)
Optical SystemDual-beam, dual-wavelength photometer with 12 filters (340–880 nm), 10 mm pathlength cuvettes
Absorbance Linearity0.001–4.200 Abs
Resolution0.0001 Abs
Minimum Reaction Volume180 μL
Sample Capacity100 positions (5 rotating racks)
Reagent Capacity72 positions (refrigerated at 10 °C)
Dispensing Precision0.1 μL (1.0–900 μL sample
Dilution RatioUp to 100×
Cuvette Disk80 reusable quartz/glass cuvettes
ComplianceUS EPA Method 353.2 (with Cd-column module), ISO/IEC 17025-compatible operation
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAMS Alliance
OriginFrance
ModelPROXIMA
Product TypeContinuous Flow Analyzer
Wavelength Range340–1100 nm
Sample Capacity≥100 positions
Reagent Positions1–20
Flow Cell Pathlength15–50 mm
Light SourceTungsten-Halogen Lamp
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAMS Alliance
ModelFUTURA
TypeContinuous Flow Analyzer
Wavelength Range340–1100 nm
Sample Capacity≥100 positions
Reagent Positions≥100
Flow Cell Path Length15–50 mm
Light SourceTungsten-Halogen Lamp
Analysis Rate15–120 samples/hour
Sample Volume0.5–100 µL
Peristaltic Pump13 rollers per channel
Flow Rate Range50–3000 µL/min
Linear Absorbance Range0–2.5 AU
Dimensions240 × 650 × 410 mm
Weight17 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAMS Alliance
OriginItaly
ModelSmartChem200
Product TypeAutomated Discrete Analyzer
Wavelength Range420–880 nm
Sample Capacity126 positions
Reagent Positions10 (expandable to 28)
Cuvette Path Length10 mm
Light Source6 V / 10 W Halogen Tungsten Lamp (2000 h lifetime)
Measurement SpeedUp to 200 tests/hour (per method)
Minimum Reaction Volume300 µL
Absorbance Range0.001–2.500 Abs
Absorbance Resolution0.0001 Abs
Thermostat Accuracy37 °C ± 0.3 °C
Dimensions (H×W×L)420 × 650 × 1000 mm
Weight43 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAMS Alliance
OriginItaly
ModelSmartChem 600
Product TypeDiscrete Flow Analyzer
Wavelength Range340–880 nm
Sample Capacity200 positions
Reagent Positions100
Cuvette Pathlength6 or 10 mm
Light SourceLED
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAMS Alliance
OriginItaly
ModelSmartChem 450
Sample Capacity100 positions (standard configuration)
Reagent Positions72 (with optional refrigeration)
Wavelength Range340–880 nm
Cuvette Path Length6 mm
Light Source6 V / 10 W halogen lamp
Throughputup to 450 determinations per hour (including ISE module)
Absorbance Range0.001–4.200 Abs
Resolution0.0001 Abs
Temperature Control37 °C ± 0.3 °C
Dimensions500 × 700 × 1050 mm (H × W × L)
Weight48 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAMS Alliance
OriginItaly
ModelSmartchem140
Product TypeDiscrete Flow Analyzer
Wavelength Range330–840 nm
Sample Capacity64 positions
Reagent Positions24 + 10
Cuvette Path Length6 mm
Light SourceHalogen Lamp