- All
- Favorite
- Popular
- Most rated
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | Smartchem 450 |
| Sample Throughput | Up to 450 samples/hour (colorimetric), 150 samples/hour (ISE) |
| Reaction Temperature Range | 30–50 °C (adjustable, ±0.1 °C accuracy) |
| Optical System | Dual-beam, dual-wavelength photometer with 12 filters (340–880 nm), 10 mm pathlength cuvettes |
| Absorbance Linearity | 0.001–4.200 Abs |
| Resolution | 0.0001 Abs |
| Minimum Reaction Volume | 180 μL |
| Sample Capacity | 100 positions (5 rotating racks) |
| Reagent Capacity | 72 positions (refrigerated at 10 °C) |
| Dispensing Precision | 0.1 μL (1.0–900 μL sample |
| Dilution Ratio | Up to 100× |
| Cuvette Disk | 80 reusable quartz/glass cuvettes |
| Compliance | US EPA Method 353.2 (with Cd-column module), ISO/IEC 17025-compatible operation |
| Brand | AMS Alliance |
|---|---|
| Origin | France |
| Model | PROXIMA |
| Product Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | ≥100 positions |
| Reagent Positions | 1–20 |
| Flow Cell Pathlength | 15–50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Brand | AMS Alliance |
|---|---|
| Model | FUTURA |
| Type | Continuous Flow Analyzer |
| Wavelength Range | 340–1100 nm |
| Sample Capacity | ≥100 positions |
| Reagent Positions | ≥100 |
| Flow Cell Path Length | 15–50 mm |
| Light Source | Tungsten-Halogen Lamp |
| Analysis Rate | 15–120 samples/hour |
| Sample Volume | 0.5–100 µL |
| Peristaltic Pump | 13 rollers per channel |
| Flow Rate Range | 50–3000 µL/min |
| Linear Absorbance Range | 0–2.5 AU |
| Dimensions | 240 × 650 × 410 mm |
| Weight | 17 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem200 |
| Product Type | Automated Discrete Analyzer |
| Wavelength Range | 420–880 nm |
| Sample Capacity | 126 positions |
| Reagent Positions | 10 (expandable to 28) |
| Cuvette Path Length | 10 mm |
| Light Source | 6 V / 10 W Halogen Tungsten Lamp (2000 h lifetime) |
| Measurement Speed | Up to 200 tests/hour (per method) |
| Minimum Reaction Volume | 300 µL |
| Absorbance Range | 0.001–2.500 Abs |
| Absorbance Resolution | 0.0001 Abs |
| Thermostat Accuracy | 37 °C ± 0.3 °C |
| Dimensions (H×W×L) | 420 × 650 × 1000 mm |
| Weight | 43 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem 600 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 340–880 nm |
| Sample Capacity | 200 positions |
| Reagent Positions | 100 |
| Cuvette Pathlength | 6 or 10 mm |
| Light Source | LED |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | SmartChem 450 |
| Sample Capacity | 100 positions (standard configuration) |
| Reagent Positions | 72 (with optional refrigeration) |
| Wavelength Range | 340–880 nm |
| Cuvette Path Length | 6 mm |
| Light Source | 6 V / 10 W halogen lamp |
| Throughput | up to 450 determinations per hour (including ISE module) |
| Absorbance Range | 0.001–4.200 Abs |
| Resolution | 0.0001 Abs |
| Temperature Control | 37 °C ± 0.3 °C |
| Dimensions | 500 × 700 × 1050 mm (H × W × L) |
| Weight | 48 kg |
| Brand | AMS Alliance |
|---|---|
| Origin | Italy |
| Model | Smartchem140 |
| Product Type | Discrete Flow Analyzer |
| Wavelength Range | 330–840 nm |
| Sample Capacity | 64 positions |
| Reagent Positions | 24 + 10 |
| Cuvette Path Length | 6 mm |
| Light Source | Halogen Lamp |