Small Animal In Vivo Imaging System
Filter
Showing 91–95 of 95 results
| Brand | RWD |
|---|---|
| Origin | Shenzhen, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | RFSLI ZW |
| Instrument Type | Optical Imaging System |
| Maximum Scan Resolution | 2048 × 2048 pixels |
| Frame Rate | 120 FPS |
| Field of View | 90 mm × 90 mm |
| Simultaneous Sample Capacity | 4 |
| Spatial Resolution | 3.9 µm/pixel |
| Laser Power Stability | <1% RMS fluctuation |
| Minimum Perfusion Unit (PU) Resolution | 0.001 PU |
| Optical Zoom | 12× |
| Data Acquisition Mode | Real-time dynamic contrast imaging |
| Origin | Imported |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Model | SFA-500-2V |
| Price | Upon Request |
| Sample Volume | 50 µL |
| Analysis Time | 4.5 min |
| Temperature Control Range | 25–42 °C ±0.2 °C |
| Concentration Range | 5–250 × 10⁶/mL |
| Velocity Thresholds | V > 4 µm/sec (motile), V > 25 µm/sec (highly motile) |
| Mean Sperm Velocity | µm/sec |
| Coefficient of Variation | <5% (precision & repeatability) |
| Dimensions (W×D×H) | 300 × 300 × 185 mm |
| Weight | 2.8 kg |
| Power Supply | 230 V / 50 Hz |
| Includes | Quartz Cuvette, Dedicated Acquisition & Analysis Software |
| Brand | SOPTOP |
|---|---|
| Origin | Zhejiang, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (China) |
| Model | NIR-II-MS |
| Price Range | USD 210,000 – 350,000 |
| Instrument Category | Optical Imaging System |
| Spectral Sensitivity Range | 900–1700 nm |
| Maximum Penetration Depth | Up to 1.4 mm |
| Brand | Analytik Jena |
|---|---|
| Origin | USA |
| Manufacturer | Analytik Jena GmbH (Germany) |
| Model | UVP Biospectrum Advanced 900 |
| Imaging Modality | Optical Bioluminescence & Fluorescence Imaging |
| Spectral Sensitivity Range | 405–810 nm |
| Field of View | 33.5 cm × 32 cm |
| Maximum Simultaneous Samples | 10 mice |
| Detector | −100 °C Cooled Back-Illuminated CCD |
| Lens | Fixed-focus f/0.95 lens |
| Integrated Temperature-Controlled Stage | Yes |
| Onboard Isoflurane Anesthesia Delivery | Yes |
| Software Compliance | FDA 21 CFR Part 11, Audit Trail, Electronic Signatures |
| Filter Customization | User-selectable excitation/emission filter sets |
| Brand | Analytik Jena |
|---|---|
| Origin | Germany |
| Model | UVP iBOX Scientia |
| Imaging Modality | Optical (Bioluminescence & Fluorescence) |
| Detector | Cooled CCD Camera |
| Lens | Fixed-focus, High-Aperture |
| Filter Options | 21 Position Motorized Filter Wheel (GFP, RFP, NIR, etc.) |
| Temperature Control | Integrated Heating Stage (37 °C ± 0.5 °C) |
| Anesthesia | Onboard Isoflurane Delivery System |
| Throughput | Up to 5 Mice Simultaneously |
| Compliance | CE, ISO 13485 (as applicable to lab instrumentation), GLP-Compatible Data Management |