Small Animal In Vivo Imaging System
Filter
Showing 31–60 of 95 results
| Origin | Sichuan, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | C2008 |
| Pricing | Upon Request |
| Brand | Clinox |
|---|---|
| Origin | Shanghai, China |
| Model | IVScope 8200 |
| Imaging Modality | Optical (Bioluminescence & Fluorescence) |
| Camera | 6 MP, Front-Illuminated Cooled CCD (Optional Water-Cooled) |
| Cooling Temperature | Down to −90 °C |
| Lens | Motorized f/0.8 Aperture |
| Field of View | Adjustable from 10.5 cm × 8.4 cm to 23.5 cm × 18.8 cm |
| Maximum FOV | 24 cm × 24 cm |
| Spatial Resolution | 1024 × 1024 pixels |
| Minimum Exposure Time | <10 ms |
| Sample Capacity | Up to 5 Mice Simultaneously |
| Stage Temperature Control | Ambient to 42 °C |
| Illumination Sources | White Light (Reflectance), Optional UV/Visible/NIR LED Arrays & Upconversion Laser Module |
| Filter Wheel | Motorized, Supports Multiple Emission Filters |
| Software | Integrated Acquisition & Quantitative Analysis Suite with ROI-Based Radiance Calibration |
| Brand | Clinox |
|---|---|
| Origin | Shanghai, China |
| Model | IVScope 8500 |
| Imaging Modality | Bioluminescence & Fluorescence Optical Imaging |
| Camera | 1 MP Front-Illuminated Cooled CCD (Optional Water-Cooled) |
| Cooling Temperature | Down to –90 °C (with optional chiller) |
| Lens | Motorized f/0.8 Wide-Aperture Lens |
| Field of View | Adjustable from 11 cm × 11 cm to 25 cm × 25 cm |
| Maximum FOV | 24 cm × 24 cm |
| Spatial Resolution | 1024 × 1024 pixels |
| Minimum Exposure Time | <10 ms |
| Sample Capacity | Up to 5 Mice Simultaneously |
| Stage Temperature Control | Ambient to 42 °C |
| Excitation Sources | White Light (Reflectance), Optional UV/Vis/NIR LED Arrays & Upconversion Laser Module |
| Filter Wheel | Motorized, Supports Multiple Emission Filters |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | Clinox |
|---|---|
| Origin | Shanghai, China |
| Model | IVScope 8500X |
| Imaging Modality | Optical (Bioluminescence/Fluorescence) + X-ray |
| Max Sample Capacity | 5 mice |
| CCD Resolution | 1024 × 1024 |
| Field of View | 11 cm × 11 cm to 25 cm × 25 cm (continuously adjustable) |
| X-ray Minimum Resolvable Feature Size | 0.16 mm |
| Lens Aperture | f/0.8 motorized auto-focus lens |
| Radiation Shielding | ≤0.5 mR/h at 5 cm from chassis wall (compliant with FDA 21 CFR 1020.40) |
| Stage Temperature Control | Ambient to 42 °C |
| Camera Type | Front-illuminated CCD (water-cooling optional) |
| Excitation Sources | White light reflectance (standard), UV/VIS/NIR reflectance & upconversion laser modules (optional) |
| Filter System | Motorized filter wheel with emission filter support |
| Anesthesia Interface | Integrated gas anesthesia delivery |
| Brand | Clinx |
|---|---|
| Origin | Shanghai, China |
| Model | IVScope 8200X |
| Imaging Modality | Optical (Bioluminescence/Fluorescence) + X-ray |
| Max Sample Capacity | 5 mice |
| CCD Resolution | 1024 × 1024 |
| Field of View | 11 cm × 11 cm to 25 cm × 25 cm |
| X-ray Minimum Resolvable Feature Size | 0.16 mm |
| Lens Aperture | f/0.8 motorized auto-focus lens |
| Camera | 6 MP front-illuminated cooled CCD (optional water-cooling to −90 °C) |
| Sample Stage Temperature Control | Ambient to 42 °C |
| Radiation Shielding | ≤0.5 mR/h at 5 cm from base enclosure (compliant with FDA 21 CFR 1020.40) |
| Illumination Sources | Standard white-light reflectance |
| Filter System | Motorized filter wheel with emission filter slots |
| Anesthesia Interface | Integrated gas anesthesia delivery system |
| Software | FDA 21 CFR Part 11–compliant acquisition and quantification suite |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Model | BHP6601 |
| Type | Single-Head Gamma Camera-Based SPECT System |
| Effective Field of View | ≥510 mm × 390 mm |
| Energy Range | 50–400 keV |
| Intrinsic Spatial Resolution | ≤3.8 mm FWHM |
| Maximum Count Rate | ≥140 kcps |
| Intrinsic Uniformity (Differential) | ≤2.2% |
| (Integral) | ≤2.8% |
| Dimensions (System) | 170 × 183 × 200 cm |
| Weight (System) | 1950 kg |
| Patient Table | 266 × 57 × 65 cm, 250 kg |
| Power Cabinet | 43 × 50 × 96 cm, 47 kg |
| Collimator Cart (Single) | 71 × 83 × 124 cm, 180 kg |
| Software | Full-featured, Chinese-language native interface |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Origin | Hebei, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | BHP6603 |
| Instrument Type | Radionuclide Imaging System |
| Power Supply | 220 V AC ±10%, 50–60 Hz, 8 A, Single-Phase, 1.7 kVA |
| Thermal Dissipation | 5100 kJ/h |
| Operating Temperature | 15–30 °C (59–86 °F), Max Temp. Ramp Rate: ±3 °C/h |
| Relative Humidity | 20–70 % RH |
| System Weight | 1500 kg (3307 lb) |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Origin | Hungary |
| Manufacturer | Mediso Medical Imaging Systems |
| Instrument Type | Nuclear Medicine SPECT Scanner |
| Detector Configuration | Dual-Head, Variable-Angle |
| Acquisition Modes | Planar & Tomographic (SPECT) |
| Key Hardware | Fully Digital High-Resolution Detectors, Integrated Single-Board Electronics, Motorized Collimator Changer, NIR-Based Patient Contour Mapping |
| Field of View (FOV) | ≥530 mm × 390 mm |
| Energy Range | 40–600 keV |
| Intrinsic Spatial Resolution | ≤3.6 mm FWHM |
| Maximum Count Rate | ≥220 kcps |
| Intrinsic Uniformity (Differential/Integral) | ≤1.9% / ≤2.4% |
| Intrinsic Spatial Linearity (Differential/Absolute) | ≤0.18 mm / ≤0.38 mm |
| Gantry Dimensions (L×W×H) | 1160 × 1520 × 1500 mm |
| Total System Weight | 2200 kg |
| Patient Table (L×W×H) | 2000 × 800 × 650 mm |
| Weight | 350 kg |
| Collimator Cart (L×W×H) | 750 × 560 × 1250 mm |
| Weight | 125 kg |
| Brand | Hamamatsu Photonics (BHP) |
|---|---|
| Origin | Japan |
| Model | A12801-01 |
| Mounting | C-mount to C-mount (linear configuration) |
| Input Mount | C-mount (female) |
| Output Mount | C-mount (male) |
| Relay Lens Magnification | 1.0× |
| Field of View (W-VIEW mode) | 13 mm × 6.4 mm |
| Field of View (Bypass mode) | 13 mm × 13 mm |
| Transmission Wavelength Range | 400–800 nm |
| Peak Transmission (Bypass mode) | ≥97% |
| Dichroic Mirror Compatibility | 25.2 mm × 35.6 mm (±0.1 mm, max thickness 2.0 mm) |
| Bandpass Filter Compatibility | Ø25.4 mm (−0/+0.6 mm tolerance, max thickness 6.0 mm) |
| Chromatic Aberration Correction | Integrated achromatizing lens unit for magnification matching between channels |
| Operating Temperature | 0–40 °C |
| Storage Temperature | −10–50 °C |
| Relative Humidity (non-condensing) | ≤70% |
| Mode Switching | Manual dichroic insertion/removal for W-VIEW ↔ Bypass operation |
| Optical Path Geometry | Collinear, symmetric design for upright and inverted microscopes |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HTNMR (Huantong NMR) |
| Model | HT-3DNMR-25 |
| Instrument Type | Benchtop Permanent-Magnet MRI System |
| Field Strength | 0.45–0.5 T |
| ¹H Resonance Frequency | 18–22 MHz |
| Bore Diameter | 150 mm |
| Effective Imaging Volume (FOV) | 25 mm × 25 mm × 25 mm |
| Gradient Strength | 10 G/cm (max 70 mT/m per axis) |
| Spatial Resolution (isotropic) | 0.08 mm (high-res mode) |
| Image Matrix | Up to 256 × 256 × 128 |
| Magnetic Homogeneity | < 8 ppm over 25 mm DSV |
| Temperature Stability | ±0.06 K/h (after 2 h warm-up) |
| Field Drift | ≤100 Hz/h (Larmor frequency) |
| Linearity | >98% in X/Y/Z over 20 mm DSV |
| RF Probe ID | 25 mm diameter solenoid or saddle coil |
| Sample Compatibility | Live mice (≥4 weeks), plant tissues, insects, hydrogels, food samples, polymer phantoms |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | HT-AMNMR-50 |
| Instrument Type | Benchtop Permanent-Magnet MRI System |
| Animal Model Compatibility | Rat |
| Magnetic Field Strength | 0.3–0.54 T |
| ¹H Resonance Frequency | 18–23 MHz |
| Magnet Bore Diameter | 250 mm |
| Sample Aperture | Φ50 mm |
| Magnetic Field Homogeneity | <8 ppm over 45×45×45 mm³ |
| Image Matrix | up to 256×256×128 |
| Spatial Resolution | down to 0.08 mm (isotropic) |
| Temperature Stability | ±0.06 K/h (after 2-h warm-up) |
| Field Drift | ≤100 Hz/h (Larmor frequency) |
| Maximum Gradient Strength | 70 mT/m (X/Y/Z) |
| Image Linearity | >98% over 50×50×50 mm³ |
| Brand | HTNMR |
|---|---|
| Model | HT-LFMR |
| Field Strength | < 0.5 T |
| Animal Compatibility | Mouse (in vivo) |
| Maximum Sample Penetration Depth | 60 mm |
| Bore Diameter Options | 40 mm / 60 mm |
| Operating Temperature Range | Customizable (Low-Temp & High-Temp Options Available) |
| Primary Measurement Parameters | T₁ Relaxation Time, T₂ Relaxation Time, Diffusion Coefficient (D) |
| Application Domain | Non-Destructive Quantitative Analysis of Water Distribution, Oil Content, Seed Viability, Food Quality, and Biomaterial Microstructure |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Domestic |
| Model | HT-MRSI60-25 |
| Instrument Type | Magnetic Resonance Imaging (MRI) & Magnetic Resonance Spectroscopic Imaging (MRSI) System |
| Spatial Resolution | 0.8 ppm (chemical shift resolution) |
| Field of View (FOV) | 25 mm × 30 mm |
| Magnetic Field Strength | 1.5 T |
| ¹H Resonance Frequency | 55–59 MHz |
| Homogeneity | <2 ppm over 25 mm DSV |
| Temperature Stability | ±0.06 K/h after 2-h warm-up |
| SNR | 55 dB |
| Geometric Distortion | <1% |
| Image Matrix | Up to 512 × 512 (2D), 128 × 128 × 128 (3D), 64 × 64 × 64 × 64 (4D MRSI) |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | OEM Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HT-MRSI60-35 |
| Instrument Type | Magnetic Resonance Imaging (MRI) System |
| Animal Species | Mouse (also compatible with rat and small plant specimens) |
| Maximum Sample Diameter | 35 mm |
| Maximum Sample Height | 50 mm |
| Spatial Resolution | 0.08 mm (high-resolution mode) |
| Field Homogeneity | ≤ 8 ppm over DSV 20 mm |
| Field Stability | Frequency drift ≤ 100 Hz/h |
| Imaging Matrix Options | 128×128×128 (standard), 256×256×128 (high-res), 512×512×128 (ultra-high-res) |
| Multi-nuclear Capability | ¹H, ¹⁹F, ³¹P |
| Magnet Type | Permanent Magnet (1.5 T) |
| Cryogen-Free | Yes |
| Passive Shielding | Integrated self-shielding design |
| RF Coil Configuration | Tunable multi-nuclei volume coil (standard) |
| Number of Simultaneous Samples | 1 |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Region of Origin | Domestic (China) |
| Model | HT-MRSI60-50 Series |
| Instrument Type | Preclinical Magnetic Resonance Imaging System |
| Animal Model | Mouse (also compatible with rat and small biological specimens) |
| Spatial Resolution (in vivo) | 0.15 mm (standard), down to 0.08 mm (high-resolution mode) |
| Field Strength | 1.5 T (permanent magnet) |
| Bore Diameter | Φ50 mm × H80 mm |
| Maximum Sample Depth | 50 mm |
| Image Matrix Options | 128×128×128 (standard), 256×256×128 (high-res), 512×512×128 (ultra-high-res) |
| Nuclei Supported | ¹H, ¹⁹F, ³¹P |
| Magnetic Field Homogeneity | ≤8 ppm over DSV 30 mm |
| Field Stability | ≤100 Hz/h frequency drift |
| Shielding | Integrated self-shielding (no external RF or magnetic shielding required) |
| Cryogen-Free | Yes (permanent magnet design) |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Magnetic Resonance Imaging (MRI) System |
| Animal Model Compatibility | Rat, Mouse |
| Field of View (FOV) | 50 mm diameter × 80 mm height |
| Maximum Sample Diameter | Φ50 mm |
| Detection Depth | 50 mm |
| Spatial Resolution | 0.15 mm (standard mode), 0.08 mm (high-resolution mode) |
| Image Matrix Options | 128×128×128, 256×256×128, 512×512×128 |
| Magnetic Field Homogeneity | ≤8 ppm over 20 mm DSV |
| Field Stability | Frequency drift ≤100 Hz/h |
| Multi-Nucleus Capability | ¹H, ¹⁹F, ³¹P |
| Magnet Type | Permanent Magnet (1.5 T) |
| Cryogen-Free Operation | Yes |
| Passive Shielding | Integrated self-shielding design |
| Compliance | Designed for GLP-compliant preclinical research environments |
| Brand | HTNMR |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | HTNMR Scientific Equipment Co., Ltd. |
| Instrument Type | Magnetic Resonance Imaging (MRI) System |
| Animal Model | Rat (also compatible with mouse) |
| Spatial Resolution | 0.15 mm |
| Field of View (FOV) | 50 mm |
| Matrix Sizes | 128×128×128 (standard), 256×256×128 (high-resolution), 512×512×128 (ultra-high-resolution) |
| Maximum Sample Depth | 50 mm |
| Sample Capacity | 1 animal per scan |
| Magnet Type | Permanent magnet (cryogen-free) |
| Brand | Huatong NMR (HTNMR) |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Category | Preclinical MRI System |
| Animal Model | Rat |
| Magnetic Field Strength | 1.2 T ±0.05 T |
| Proton Resonance Frequency | 51 MHz ±2 MHz |
| Magnet Pole Diameter | 300 mm |
| Effective Imaging Volume (Coil Bore) | Φ50 mm × H80 mm |
| Field Homogeneity | <8 ppm over 50 mm × 50 mm × 80 mm DSV |
| Spatial Resolution (in-plane) | 0.08 mm (measured on 0.05 mm water phantom) |
| Gradient Strength | 10 G/cm (100 mT/m) |
| Max Gradient Amplitude | 200 mT/m (X/Y/Z) |
| Image Matrix | Up to 256 × 256 × 128 |
| Image Linearity | >98% in X/Y/Z (50 mm × 50 mm × 80 mm) |
| Temperature Stability | ±0.005 °C chamber control, 1 m°C display resolution |
| Field Drift | <100 Hz/h (Larmor frequency drift) |
| Data Format | DICOM-compliant export |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Hyper |
| Instrument Type | Tomographic Imaging System |
| Energy Resolution | 1.4–5.3 mT |
| Spatial Resolution | 100 µm |
| Scan Time | 10 s per volume |
| Field of View (FOV) | 60 mm × 60 mm × 120 mm |
| Sample Capacity | 1 animal |
| Brand | INDEC BioSystems |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Type | Optical In Vivo Imaging System |
| Scan Speed | Millisecond (ms) Exposure |
| Channel Configuration | 1 or 3 User-Selectable Fluorescence Channels |
| Spectral Range | 400–900 nm (Customizable Across Visible to Near-Infrared) |
| Software | FluorVivo Imaging & Analysis Suite (v5.x) with Spectral Unmixing, ROI Quantification, and Video Capture |
| Optional Modules | FluorVivo Pathfinder (Fluorescence-Guided Surgery Platform), FluorVivo Mag (In Vivo Cell-Level Imaging Interface for Stereo/Fluorescence Microscopes) |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | IVIM |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Optical In Vivo Imaging System |
| Energy Resolution | 4 keV |
| Scan Resolution | 512 × 512 pixels |
| Frame Rate | 100 fps |
| Field of View | 10 × 10 µm to 100 × 100 mm² |
| Sample Thickness Capacity | 4 mm |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IVM-MS |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Optical Imaging System |
| Energy Resolution | 0.2 keV |
| Scan Resolution | 1024 × 1024 pixels |
| Frame Rate | 100 fps |
| Field of View (FOV) | 100 × 100 µm² to 10 × 10 mm² |
| Sample Capacity | 1 animal per imaging session |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | IVM-CM |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Optical Imaging System |
| Energy Resolution | 0.2 keV |
| Scanning Resolution | 512 × 512 pixels |
| Frame Rate | 100 fps |
| Field of View (FOV) | 100 × 100 µm² to 10 × 10 mm² |
| Sample Capacity | 1 animal per session |
| Origin | South Korea |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | IVM-M |
| Price Range | USD 420,000 – 700,000 |
| Instrument Type | Optical Imaging System |
| Energy Resolution | 0.2 keV |
| Scanning Resolution | 512 × 512 pixels |
| Frame Rate | 100 fps |
| Field of View (FOV) | 100 × 100 µm² to 10 × 10 mm² |
| Sample Capacity | 1 animal per imaging session |
| Brand | KeChenStarFly |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LumiFluor AVIS Faye A |
| Instrument Type | Optical In Vivo Imaging System |
| Price Range | USD 70,000 – 700,000 (approx.) |
| Imaging Modalities | Bioluminescence & Fluorescence |
| Brand | Lei-Tech |
|---|---|
| Origin | Tianjin, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | LK-TSBM |
| Instrument Type | Optical Imaging System |
| Optical System | Galilean |
| Total Magnification Range | 6.3×–80× |
| Eyepiece Field of View | 22 mm |
| Objective Working Distance | 80 mm |
| Zoom Ratio | 12.5:1 (0.63×–8×) |
| Illumination | Adjustable Color Temperature LED Ring Light (3000–5600 K), Brightness-Controlled Lower LED Array (144 LEDs), Optional Oblique Illumination |
| Focus Mechanism | Coaxial Coarse/Fine Focus with 50 mm Travel, 2 µm Fine Adjustment Resolution |
| Eyepiece Configuration | Widefield High-Eyepoint WF10×/22 mm, Interpupillary Distance 50–76 mm, Tiltable Trinocular Head (5°–45°), Dual Light Path Selection (100% Binocular or 100% Trinocular) |
| Aperture Diaphragm | Integrated Manual Control |
| Objective Lens | Achromatic Apo-Corrected 1× Main Objective |
| Stage Compatibility | Compatible with LK-TSHWT-60 Heated Stage (Temp. Range: RT–60 °C, Accuracy: ±0.2 °C, Output: 36 V / 50 W) |
| Compliance | Designed for GLP-aligned laboratory workflows |
| Brand | Magtech |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Nuclear Magnetic Resonance Imaging System |
| Time Resolution | 20 ns |
| Field of View (FOV) | 60 mm × 60 mm |
| Model | MT-MRI-20 |
| Brand | Molecular Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | SpectraMax MiniMax 300 Cell Imaging System |
| Instrument Type | Optical Imaging System |
| Compatibility | Designed exclusively for integration with SpectraMax i3x Multi-Mode Microplate Readers |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Momentum |
| Instrument Type | Tomographic Imaging |
| Energy Resolution | 1.4–5.3 mT |
| Spatial Resolution | 100 µm |
| Scan Speed | 10 s per volume |
| Field of View (FOV) | 6 cm × 6 cm × 12 cm |
| Sample Capacity | 1 animal |
| Brand | NIUMAG |
|---|---|
| Origin | Israel |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | M3 |
| Instrument Type | Preclinical Magnetic Resonance Imaging (MRI) System |
| Magnet Type | Permanent Magnet, 1.0 T |
| Spatial Resolution | ≤ 235 µm (isotropic) |
| Scan Time | As low as 8–9 min per sequence |
| Cooling | Passive (No Cryogens or Chiller Required) |
| Shielding | Self-Shielded, Zero Stray Field |
| Regulatory Compliance | CE Marked, Designed for GLP-Compliant Preclinical Research |
| Application Focus | Mouse Phenotyping, Longitudinal In Vivo Imaging |