Spectrometry Instruments
Filter
Showing 241–254 of 254 results
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PULSAR |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid and Liquid Samples |
| Sensitivity | SNR = 25:1 at 2.6 ppm for 1% ethylbenzene, single-scan |
| Resolution | 1.8 Hz (0.03 ppm) |
| Operating Frequency | 60 MHz |
| Magnet Type | Permanent Magnet |
| Cryogen-Free Operation | Yes |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | PULSAR-60 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Compatibility | Solid and Liquid Samples |
| Sensitivity | SNR ≥ 100:1 at 2.6 ppm for 1% ethylbenzene (single scan) |
| Resolution | 0.5 Hz (0.0083 ppm) |
| Operating Frequency | 60 MHz (1.4 T permanent magnet) |
| Sample Tube | Standard 5 mm OD NMR tube |
| Cryogen-Free Operation | Yes (permanent magnet, no liquid nitrogen or helium required) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X-Pulse 90 |
| Instrument Type | High-Field Benchtop NMR Spectrometer |
| Sensitivity | 240:1 for 1% ethylbenzene |
| Resolution | < 0.35 Hz (50% peak height) / < 15 Hz (0.55% peak height) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | X-Pulse |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Form | Liquid |
| Operating Frequency | 60 MHz |
| Data Acquisition Mode | Pulsed Fourier Transform |
| Signal-to-Noise Ratio | >180:1 |
| Spectral Resolution | <0.35 Hz |
| ¹H Quantitative Reproducibility | Excellent |
| Brand | Skyray Instrument |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Country of Origin | China |
| Model | WDX3300 |
| Pricing | Upon Request |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | SolarSIM-D2 |
| Pricing | Upon Request |
| Brand | Solinst |
|---|---|
| Origin | Canada |
| Manufacturer Status | Authorized Distributor |
| Origin Category | Imported |
| Model | 105 |
| Pricing | Upon Request |
| Brand | SPEC (Beijing Spark) |
|---|---|
| Origin | Beijing, China |
| Model | SPEC-3015V |
| Instrument Type | Magnetic Resonance Imaging (MRI) System |
| Sample Compatibility | Solid–Liquid Dual-Phase Core Samples |
| Operating Mode | Pulsed Fourier Transform (PFT) |
| Magnet Bore Diameter | 300 mm |
| Field Strength Range | 0.05–1.5 T (Tunable) |
| Maximum Operating Temperature | 150 °C |
| Maximum Confining Pressure | 100 MPa |
| Supported Nuclei | ¹H, ²³Na, ¹⁹F, ¹³C |
| Cryogen Requirement | Cryogen-Free (Zero-Liquid-Helium) |
| Brand | Spectral Evolution |
|---|---|
| Model | PSR-1900 |
| Spectral Range | 350–1900 nm |
| Detector | 512-pixel Si (350–1000 nm) + 256-pixel cooled InGaAs (970–1910 nm) |
| Spectral Resolution | 3.5 nm (350–1000 nm), 10 nm @ 1900 nm |
| Spectral Sampling Interval | ≤1 nm |
| Optical Interface | Interchangeable fore-optics (4°, 8°, 14° FOV) or fiber optic input |
| Integration Time | Adjustable from 1 ms to 60 s |
| Scan Speed | Full-spectrum acquisition in 100 ms (up to 10 Hz) |
| Wavelength Accuracy | ±0.5 nm (FWHM) |
| Wavelength Repeatability | ±0.1 nm |
| Radiometric Noise (4° lens, 0.5 s integration) | 1.0×10⁻⁹ W/cm²/nm/sr @ 400 nm, 1.5×10⁻⁹ W/cm²/nm/sr @ 1500 nm |
| Calibration Traceability | NIST-traceable |
| Data Storage | Onboard memory for 500 spectra |
| Connectivity | USB 2.0 and Bluetooth 4.0 |
| Power | Dual rechargeable Li-ion batteries (7.4 V, ≥2 h field operation) |
| Dimensions | 21.6 × 29.2 × 8.3 cm |
| Weight | 3.3 kg |
| Compliance | CE, FCC, RoHS |
| Brand | Spinlock |
|---|---|
| Origin | Argentina |
| Model | SLK-200 |
| Field Strength | Low-field (typically 0.05–0.1 T, ~2–4 MHz ¹H Larmor frequency) |
| Sample Type | Solid-Liquid Dual Compatibility |
| Measurement Time | Fat/Water: 4 s |
| Protein | 12 s |
| Fatty Acids | 20 s |
| Accuracy | Protein >99% |
| Automation | Optional SLK-AS-10 Auto-sampler (2 × 50-position modules) |
| Compliance | Designed for GLP-compliant workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | picoSpin 45 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Form | Liquid Only |
| Sensitivity | ≥600:1 SNR for Single-Scan H₂O |
| Resolution | 2.25 Hz (measured on 1% ethylbenzene in CDCl₃) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | picoSpin 80 |
| Instrument Type | Low-Field NMR Analyzer |
| Sample Form | Liquid |
| Sensitivity | 18 ppb (at 1.44 Hz linewidth) |
| Resolution | 5000 (for H₂O, single-scan) |
| Brand | Oxford Instruments |
|---|---|
| Origin | United Kingdom |
| Model | Wave500, Wave700 |
| Detector Integration | Ultim Max EDS |
| Geometry | Focusing Rowland Circle with Curved Crystals |
| Energy Resolution | <10 eV at Mn Kα |
| Detection Limit | <100 ppm (typical, matrix-dependent) |
| Slit Mechanism | Motorized Incident Slit for Resolution/Background Optimization |
| Mounting Configuration | Tilted Geometry for Enhanced SEM Compatibility and Reproducible Sample Positioning |
| Compliance | Designed for integration with Zeiss SEM platforms (e.g., GeminiSEM, Sigma, Merlin) |
| Brand | Zhongke-Niujin |
|---|---|
| Origin | Hubei, China |
| Manufacturer Type | Authorized Distributor & System Integrator |
| Product Category | Domestic High-Field NMR Spectrometer |
| Model | Quantum-I Plus |
| Operating Frequencies | 400 MHz and 600 MHz |
| Measurement Principle | Pulsed Fourier Transform (PFT) NMR |
| Sample Form | Liquid-state |
| Excitation Mode | RF Pulse Sequencing with Digital IF Sampling |
| Sensitivity | High (¹H S/N ≥ 500:1 @ 1% ethylbenzene, 1 scan, 5 mm probe) |
| Resolution | High (¹H linewidth ≤ 0.4 Hz, shimming optimized) |
| Quantitative Reproducibility | High (¹H integral RSD < 0.5% over 24 h) |
| Probe Compatibility | Broadband multinuclear (¹H, ¹³C, ¹⁵N, ³¹P, etc.), manual/automatic tuning, custom-configurable for 400–600 MHz superconducting magnets |