| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Models | SW-CJ-1F, SW-CJ-1FD, SW-CJ-2F, SW-CJ-2FD |
| Instrument Type | Vertical Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-Operator Single-Face, Single-Operator Dual-Face, Dual-Operator Single-Face, Dual-Operator Dual-Face |
| Airflow Pattern | Vertical Downflow |
| Regulatory Compliance | YY/T 1539–2017 (China CFDA Medical Clean Bench Standard), Class II Medical Device Registration Certificate Issued |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Variants | SW-CJ-1B, SW-CJ-1BU, SW-CJ-1C, SW-CJ-1CU |
| Instrument Category | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-user single-face or dual-user single-face |
| Airflow Pattern | Horizontal laminar flow |
| Regulatory Compliance | YY/T 1539–2017 (CFDA Medical Device Standard), Class II Medical Device Registration Certificate |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Cabinet Type | Class II, Type B2 (Total Exhaust, Non-Recirculating) |
| Models | BSC-1004IIB2, BSC-1304IIB2, BSC-1604IIB2, BSC-1804IIB2 |
| External Dimensions (L×W×H, mm) | 1200/1500/1800/2000 × 795 × 2050 |
| Internal Work Area Dimensions (L×W×H, mm) | 1004/1304/1604/1804 × 630 × 630 |
| ULPA Filter Efficiency | ≥99.9995% @ 0.12 µm |
| Airflow Control | Brushless DC Constant-Flow Fan with Intelligent Compensation |
| Filter Leak Integrity | Dual “Leak-Resistant” Sealing Technology for Supply & Exhaust Filters |
| Cleanliness Class | ISO 4 (equivalent to Federal Standard 209E Class 10) |
| Power Management | Power-Fail Memory & Standby Mode with Sash-Closure Trigger |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | SW-CJ-1F, SW-CJ-1FD, SW-CJ-2F, SW-CJ-2FD-II |
| Airflow Type | Vertical Downflow |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| Operator Configurations | Single-Person/Single-Side, Single-Person/Double-Side, Double-Person/Single-Side, Double-Person/Double-Side |
| Construction | Stainless Steel Work Surface, Powder-Coated Cold-Rolled Steel Enclosure |
| Pre-Filter | Quick-Release Design for Easy Cleaning and Replacement |
| UV Lamp Control | Programmable On/Off Scheduling with Runtime Monitoring |
| Fan Speed | Three-Step Adjustable |
| Safety Interlock | Lighting and UV Sterilization Systems Are Electrically Interlocked |
| Power Protection | Built-in Uninterruptible Power Backup Function |
| Mobility | Locking Swivel Casters with Brake Mechanism |
| Compliance | Factory-Tested per GB/T 25223–2010 (Chinese National Standard for Clean Benches), Meets General Requirements of YY 0569–2011 (Medical Device Safety for Biological Safety Cabinets) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Models | SW-CJ-1B / SW-CJ-1BU / SW-CJ-1C / SW-CJ-1CU-II |
| Instrument Type | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US Federal Standard 209E) |
| Noise Level | ≤62 dBA |
| User Configuration | Single- or Dual-Operator, Front-Access Only |
| Airflow Pattern | Horizontal Laminar Flow |
| Control Interface | Digital Display with Touch-Sensitive Keypad |
| UV Timer Function | Programmable On/Off Scheduling |
| Runtime Monitoring | Real-Time Accumulated Hours for Fan, UV Lamp, and Pre-Filter |
| Viewing Panels | Embedded Tempered Glass on Both Sides |
| Work Surface | Seamless Stainless Steel (AISI 304) |
| Enclosure Material | Cold-Rolled Steel with Ivory White Electrostatic Powder Coating |
| Structural Design | Aerodynamically Optimized Cabinet Profile |
| Mobility System | Locking Swivel Casters (360° Rotation) |
| Pre-Filter Access | Tool-Free Quick-Release Mechanism |
| Safety Interlock | UV Lamp Deactivation When Lighting Circuit Is Active |
| Power Protection | Built-in Backup Socket with Emergency Power-Off Capability |
| Compliance | Factory-Tested per GB/T 25227–2010 (Chinese National Standard for Clean Benches), Meets IEC 61010-1 Safety Requirements for Laboratory Equipment |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Variants | HS-840-II, HS-1300-II, HS-840-U-II, HS-1300-U-II |
| Instrument Category | Horizontal Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Sound Pressure Level | ≤62 dBA |
| User Configuration | Single-user single-face or dual-user single-face |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Control Interface | Digital display with touch-sensitive keypad |
| Fan Speed | 3-step adjustable |
| UV Lamp Control | Programmable on/off scheduling |
| Runtime Monitoring | Real-time cumulative operating time for fan, UV lamp, and filter |
| Viewing Panels | Embedded tempered glass on both side walls |
| Work Surface | Seamless 304 stainless steel with front-radius edge design |
| Cabinet Material | Cold-rolled steel with ivory-white electrostatic powder coating |
| Structural Design | Aerodynamically optimized chassis minimizing airflow turbulence |
| Mobility System | Dual-mode casters (swivel + locking brake) with leveling feet |
| Pre-filter Access | Tool-free rapid replacement and washable design |
| Safety Interlock | UV lamp and lighting circuits mutually interlocked |
| Power Features | Integrated backup socket with power-fail protection |
| Factory Certification | Performed per ISO 14644-1, IEST-RP-CC002.3, and GB/T 25227–2010 performance validation protocols |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model Variants | BSC-0605IIB2 / BSC-1005IIB2 / BSC-1305IIB2 / BSC-1605IIB2 / BSC-1805IIB2 |
| Instrument Class | Class II, Type B2 (Total Exhaust, Non-Recirculating) |
| External Dimensions (L×W×H, mm) | 1200/1500/1800/2000 × 795 × 2050 |
| Internal Work Area Dimensions (L×W×H, mm) | 1004/1304/1604/1804 × 630 × 630 |
| Filter Efficiency | ≥99.995% @ 0.3 µm (HEPA H14 per EN 1822-1) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model Variants | HS-840, HS-840-U, HS-1300, HS-1300-U |
| Instrument Category | Horizontal Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Noise Level | ≤62 dBA |
| User Configuration | Single-user single-face or dual-user single-face |
| Airflow Pattern | Horizontal unidirectional laminar flow |
| Regulatory Compliance | YY/T 1539–2017 (China CFDA Medical Clean Bench Standard), Class II Medical Device Registration Certificate issued |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Regional Category | Domestic (China) |
| Model Variants | BSC-0605IIA2 / BSC-1005IIA2 / BSC-1305IIA2 / BSC-1605IIA2 / BSC-1805IIA2 |
| Cabinet Type | Class II, Type A2 |
| External Dimensions (L×W×H, mm) | 1200/1500/1800/2000 × 795 × 2050 |
| Internal Work Area Dimensions (L×W×H, mm) | 1004/1304/1604/1804 × 630 × 630 |
| Filter Efficiency | ≥99.995% @ 0.3 µm (EN1822-1 H14/U15 certified) |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | HHS-1000-U / HHS-1300-U / HHS-1600-U / HHS-1800-U |
| Cleanliness Class | ISO Class 5 (100 @ ≥0.5 µm, per US FED-STD-209E) |
| Airflow Pattern | Horizontal laminar flow |
| Noise Level | ≤62 dBA |
| User Configuration | Single-user single-front or dual-user single-front |
| Compliance | YY/T 1539–2017 (China CFDA Medical Device Standard), Class II Medical Device Registration Certificate |
| Control Interface | Full-color LCD touchscreen with real-time display of airflow velocity, filter status, and fault diagnostics |
| Safety Interlocks | Integrated interlock between sash position, UV germicidal lamp activation, and LED lighting |
| Construction | Seamless curved stainless steel work surface (304 grade), ergonomically optimized for prolonged operation |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | BSC-1004IIA2 / BSC-1304IIA2 / BSC-1604IIA2 / BSC-1804IIA2 |
| External Dimensions (L×W×H, mm) | 1200/1500/1800/2000 × 795 × 2050 |
| Internal Work Area Dimensions (L×W×H, mm) | 1004/1304/1604/1804 × 630 × 630 |
| ULPA Filter Efficiency | ≥99.9995% @ 0.12 µm |
| Cabinet Classification | NSF/ANSI 49–2022 Class II, Type A2 |
| Airflow Velocity (Inflow/Downflow) | 0.50–0.55 m/s / 0.25–0.30 m/s (typical, per model and certification) |
| Filter Type | Dual ULPA (Supply & Exhaust) with Leak-Proof Sealing Technology |
| Power Supply | 220 V AC, 50 Hz |
| Motor Type | Brushless DC Constant-Flow Fan |
| Brand | AIRTECH |
|---|---|
| Origin | Jiangsu, China |
| Model Variants | HVS-1000-U, HVS-1300-U, HVS-1600-U, HVS-1800-U |
| Classification | Vertical Laminar Flow Clean Bench |
| Cleanliness Class | ISO Class 5 (equivalent to Federal Standard 209E Class 100 @ ≥0.5 µm) |
| Noise Level | ≤62 dBA |
| Operator Configuration | Single-user single-front or dual-user single-front |
| Airflow Pattern | Vertical downward laminar flow |
| Regulatory Compliance | YY/T 1539–2017 (China CFDA Medical Clean Bench Standard), Class II Medical Device Registration Certificate issued |
| Control Interface | Full-color LCD touchscreen with real-time display of inflow velocity, filter status, and fault alerts |
| Safety Interlocks | Integrated interlock between sash position, UV germicidal lamp activation, and lighting system |
| Construction | Seamless curved stainless steel work surface (304 grade), ergonomically contoured front edge |
| Fan System | Variable-air-volume (VAV) EC motor-driven blower with high-efficiency low-energy operation |
| Lighting | Uniform LED illumination (≥600 lux at work surface) |
| Pre-shipment Testing | 100% factory validation per ISO 14644-1 and YY/T 1539–2017 performance & safety protocols |
Show next