BrandPhoenix
OriginJiangsu, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelPX01005
Price RangeUSD 4,200 – 7,000
Dimensions650(W) × 375(D) × 530(H) mm
Power SupplyAC 220 V, 50/60 Hz, 2 A
Weight~30 kg
Required Gas SourcesO₂ ≥99.99%, N₂ ≥99.99%, C₃H₈ ≥95%
Oxygen Sensor TypeParamagnetic
Oxygen Measurement Accuracy±0.1% vol
Control SystemPLC + 7″ HMI Touchscreen
OptionalPC-based LOI control & data management software
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhinix
ModelPX04006
Combustion Chamber Dimensions750(W) × 300(D) × 900(H) mm
Control Cabinet Dimensions650(W) × 650(D) × 1600(H) mm
Power SupplyAC 220 V, 50 Hz, 16 A
Weight~180 kg
Fuel SourcePropane (≥95% purity)
Heat Flux Calibration Range0–100 kW/m²
Heat Flux Accuracy<±3%
Response Time0.2 s
Emissivity>0.95
Radiant Heat SourceNine T150 quartz infrared tubes (13 kW/m² ±4 kW/m²)
Convective Heat SourceTwo 45°-inclined Meker burners (38 mm outer diameter, 5/16″ inner orifice), 25 kW total output
Total Incident Heat Flux84 kW/m² ±2 kW/m²
Temperature MeasurementOMEGA thermocouples with stainless-steel calibration disk, 0–1100 °C range, 0.1 °C display resolution
Cooling SystemIntegrated chiller (10 L/min flow rate), water-cooled aluminum heat sink plate (340 × 286 mm), portable closed-loop water source
AutomationPLC-controlled electromechanical positioning modules for specimen and heat flux sensor actuation
Software PlatformNI LabVIEW-based HMI with real-time curve visualization, data logging, audit-trail-enabled reporting, and GLP-compliant export formats
Added to wishlistRemoved from wishlist 0
Add to compare
BrandPhinix
ModelPX03002
Standards ComplianceUL 94 HB/V0/V1/V2/5VA/5VB, IEC 60695-11-10/-11-20, ISO 1210/9770/9773, GB/T 2408/5169.17
Chamber Volume>0.75 m³
Viewing WindowLarge tempered glass, interior illumination ≤20 lux
Flame SourceHUMBOLDT Trillium burner (ID 9.5±0.3 mm, ASTM D5025 compliant)
Flame OrientationMotorized 0°/20°/45° adjustment
IgnitionHigh-voltage pulse auto-ignition
Gas ControlImported rotameter + differential pressure sensor + precision pressure regulator + solenoid valve
Sample PositioningMotorized linear stage (horizontal/vertical), software-controlled
Control SystemPLC + industrial touchscreen HMI
Safety FeaturesAuto gas cutoff after 10 min idle, flame duration alert, real-time V (mm/min) calculation and display
Optional50W/500W flame calibration kit with ±0.1°C certified thermocouples
PowerAC 220 V, 50 Hz, 2 A
Dimensions (Upper Cabinet)1350×700×1000 mm (W×D×H)
(Lower Cabinet)1350×700×650 mm
Weight~70 kg