Synthesis/Reaction Equipment
Filter
Showing 91–120 of 234 results
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | CCR-1000G |
| Reactor Type | Flow-through Catalytic Hydrogenation System |
| Max Operating Pressure | 0.4 MPa |
| Temperature Range | Ambient +15°C to 200°C (Aluminum Block Heating Block) |
| Liquid Flow Rate | Up to 0.9 mL/min |
| Gas Flow Rate | Up to 100 mL/min (H₂) |
| Catalyst Cartridge | Stainless Steel Column (Ø5 × 50 mm, replaceable) |
| Wetted Materials | PP (reaction reservoir), Fluoropolymer (fluidic pathways), Perfluoroelastomer (O-rings), SUS316 (glass support components) |
| Power Supply | AC 100 V, 50/60 Hz, 2.5 A, 250 VA |
| Dimensions (W×D×H) | 356 × 461 × 389 mm |
| Safety Features | Pressure-sensor-triggered emergency shutdown, independent overtemperature protection for heating block, heater overload protection, leakage and overcurrent protection, self-diagnostic system, communication failure detection |
| Compliance | Designed for GLP-compliant laboratory environments |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | CCX |
| Temperature Control Range (CCX-1000/1010) | RT + 10°C to 160°C (with external chiller) |
| Temperature Control Range (CCX-1200/1210) | −78°C to RT (using dry ice/acetone or cryogenic circulator) |
| Number of Reaction Vessels | 1–12 |
| Reaction Volume per Vessel | 3–15 mL (max. 25 mL) |
| Stirring Method | High-torque magnetic stirring |
| Stirring Speed | 100–1200 rpm (in water) |
| Temperature Setting & Display | Digital PID controller with membrane keypad input and LED display (CCX-1000/1010) |
| Stirring Speed Control | Rotary knob |
| Reflux Capability | Integrated high-efficiency reflux condenser (CCX-1000/1010) |
| Gas Purging | Vacuum-assisted inert gas (N₂/Ar) exchange via septum-sealed ports |
| Vessel Compatibility | Standard Φ24 × 150 mm glass tubes (straight-mouth and flanged types), PTFE caps, nitrile rubber seals |
| Wetted Materials | Borosilicate glass, PTFE, nitrile rubber |
| External Dimensions (stand only) | 245 W × 275 D × 800 H mm |
| Weight | ~8 kg |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | CCX-3200 |
| Reaction Vessel Capacity | 0.5–60 mL |
| Number of Reaction Positions | 1–8 (up to 32 with optional adapter kits) |
| Temperature Range | Ambient +10°C to 280°C (max 200°C at 50–60 mL load) |
| Stirring Speed | ~100–1200 rpm (in water) |
| Stirring Type | High-strength magnetic coupling |
| Temperature Control | Digital keypad setting & LED display |
| Stirring Control | Analog knob adjustment |
| Reflux Capability | Optional water-cooled split-head condenser |
| Reagent Addition | Via pipettes, droppers, or calibrated dispensers |
| Wetted Materials | DURAN® borosilicate glass |
| Tube Diameter Compatibility | Φ12–34 mm (12 standard sizes), max height 50 mm |
| External Dimensions (W×D×H) | 245 × 275 × 800 mm (stand only) |
| Weight | ~8 kg |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | DDL-1000 / DDL-2000 |
| Reactor Type | Jacketed Laboratory Reactor System |
| Temperature Control Modes | Reaction Mass Control, Jacket Control, Isothermal Mode, Gradient Ramp Mode |
| Stirring | Mechanical Agitation (PTFE or SUS304 Impeller) |
| Temp. Range | 10–80 °C (Jacket) |
| Temp. Stability | ±0.1 °C |
| Stirring Speed | 10–1059 rpm |
| Max. Torque | 19.6 N·m (DDL-1000), 0.49 N·m (DDL-2000) |
| Cooling Rate (Jacket) | up to 30 K/min |
| Heating Rate (Jacket) | up to 7.0 K/min |
| Safety Systems | Independent Over-Temperature Protection, Leakage Current Breaker, Low-Coolant-Level Alarm, Emergency Rapid-Cooling Function, SSR Failure Detection, Dual Temperature Limit Alarms |
| Power Supply | AC 100 V, 50/60 Hz (7 A / 700 VA for DDL-1000 |
| Dimensions & Weight | 290×380×790 mm, 20 kg (DDL-1000) |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | DDS |
| Reactor Capacity | 4 × (50 / 100 / 250 mL, independent) |
| Temperature Control Range | −50 to 250 °C (requires external chiller) |
| Temperature Accuracy | ±0.5 K (−20–100 °C, aluminum block), ±1 K (100–180 °C, aluminum block) |
| Stirring Speed | 125–1000 rpm |
| Max. Heating Rate | Tr < 5.3 K/min, Tj < 19.3 K/min (250 mL water in glass reactor) |
| Max. Cooling Rate | Tr < 7.2 K/min, Tj < 29.6 K/min (250 mL water) |
| Max. Heat Removal Capacity | 0.74–1.1 W/g (200 mL water) |
| Heat Flow Measurement Resolution | 0.1 W, ±5% error (standard conditions) |
| Control Modes | Reactor temperature, aluminum block temperature, gradient, isothermal |
| Control Method | PID heating/cooling + cascade control |
| Liquid Addition | 8-channel volumetric dosing |
| Agitation Type | Propeller stirring |
| Optional pH Control | 0–14, acid/base titration |
| Heat Measurement Principle | Thermal conductivity-based calorimetry with calibration |
| Data Visualization | Real-time & historical trend graphs |
| Safety Systems | Leakage current protection, independent overtemperature cutoff, motor overload protection, software self-diagnosis |
| Flask Ports | Rodaviss 24, NS 14/23 (×3), GL 14 (×1) |
| Vessels | Borosilicate glass, round-bottom, graduated (50 mL or 250 mL) |
| Wetted Materials | Glass, PTFE, PPS, Karlez®, SUS316 |
| Dimensions (W×D×H) | 650 × 490 × 380 mm |
| Weight | ~59 kg |
| Power Supply | AC 100 V, 50 Hz, 2000 VA, 20 A |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | PPS-1511 / PPS-2511 / PPS-3511 |
| Reaction Vessels | 1–5 units (independently controlled) |
| Synthesis Volume | 1–4 mL (PPS-1511), 10–30 mL (PPS-2511), 50–60 mL (PPS-3511) |
| Temperature Range | −23 to 160 °C (PPS-1511), −27 to 160 °C (PPS-2511), −28 to 130 °C (PPS-3511) — each zone independently adjustable |
| Temp. Control Accuracy | ±0.5 °C |
| Stirring Speed | 100–1600 rpm (4 mL water, PPS-1511), 100–1300 rpm (30 mL water, PPS-2511), 100–1100 rpm (60 mL water, PPS-3511) |
| Stirring Input | Rotary knob with digital RPM display (20–2000 rpm) |
| Temp. Input & Display | Membrane keypad with digital display (−40.0 to 160.0 °C) |
| Gas Handling | Vacuum evacuation and inert gas purging (requires optional sealed reaction vessels) |
| Reflux Capability | Integrated high-efficiency reflux condenser |
| Reagent Addition | Syringe, pipette, or standard-taper dropping funnel — all under inert atmosphere |
| Visual Monitoring | Front-access observation slot with integrated LED illumination |
| Safety Systems | Leakage current breaker, thermal fuse, self-diagnostic firmware (including sensor fault detection and user-configurable upper temperature limit), dual-layer protective housing, drip tray, aluminum block presence detection, motor overheat protection |
| Vessel Dimensions (mm) | Φ15×150H (flanged, PPS-1511), Φ30×200H (flanged, PPS-2511), Φ35×200H (flanged, PPS-3511) |
| Stir Bar Sizes (mm) | Φ10×5H (cross-type), Φ20×7H (cross-type), Φ25×8H (cross-type) |
| External Dimensions (W×D×H, mm) / Weight | 465×335×390 / 25 kg (PPS-1511), 465×335×440 / 27 kg (PPS-2511), 465×335×450 / 28 kg (PPS-3511) |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | PPS-1520 / PPS-2520 / PPS-3520 / PPS-6520 |
| Tube Capacity | 1–5 (up to 20 with optional configuration) |
| Reaction Volume Range | 0.5–60 mL |
| Temperature Control Range | −28 °C to +160 °C (5-zone independent control) |
| Temperature Programming | 7-step ramp/hold profiles |
| Stirring | High-torque magnetic stirring (optional independent stirrer per position) |
| Dosing Control | External programmable peristaltic pump interface (dose volume, rate, temp-triggered start/stop, gradient coupling) |
| Display & Interface | LCD touchscreen |
| Data Logging | Real-time USB-exportable CSV/Excel-compatible records (time-stamped temperature, stirring status, dosing events) |
| Safety Enclosure | Dual-layer acrylic shield with anti-condensation design |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | PPS-5511 |
| Temperature Control Range | −23 to 160 °C (independent per module) |
| Temp. Accuracy | ±0.5 °C |
| Stirring Speed | 100–2000 rpm (load-dependent) |
| Reaction Volume per Vessel | 0.5–60 mL |
| Number of Simultaneous Reaction Vessels | 1–5 (expandable to 20 with optional tube rack configuration) |
| Tube Diameter Compatibility | Φ12–Φ35 mm (14 standard sizes) |
| Gas Handling | Vacuum evacuation & inert gas (N₂/Ar) purging capability (requires compatible sealed vessels) |
| Safety Systems | Dual-layer acrylic shield, motor overheat protection, leakage/overcurrent breaker, thermal fuse, real-time sensor diagnostics, user-configurable upper/lower temperature limits |
| External Dimensions | 465 W × 335 D × 390 H mm (main unit) |
| Weight | ~23 kg |
| Brand | EYELA (Tokyo Rikakikai Co., Ltd.) |
|---|---|
| Origin | Japan |
| Model | PPV-3430 / PPV-3460 / PPV-3461 |
| Reaction Vessel Capacity | PPV-3430: 10–30 mL (forked test tubes, 1–4 units) |
| PPV-3460 | 50–150 mL (3-neck reaction vessels, 1–4 units) |
| PPV-3461 | 50–150 mL (4-neck reaction vessels, 1–4 units) |
| Temperature Control Range | −27 to 200 °C (low-temperature operation requires external chiller) |
| Temperature Accuracy | ±0.5 °C |
| Stirring Method | High-torque magnetic stirring |
| Rotation Speed | 50–900 rpm (tested with 30 mL water for PPV-3430 |
| Temperature Setting & Display | Membrane keypad input with digital LED display |
| Stirring Speed Setting & Display | Analog knob with digital LED display |
| Reflux Configuration | Dual-path reflux condenser with independent coolant分流 (coolant distribution manifold) |
| Reagent Addition | Compatible with syringes, dropping funnels, and calibrated pipettes under inert or vacuum conditions |
| Reaction Observation | Front-mounted aluminum observation window with integrated LED illumination |
| Safety Systems | Leakage current circuit breaker, thermal fuse, temperature controller self-diagnostic function (programmable upper-limit temperature, sensor fault detection), dual-layer protective housing, drip collection tray, motor overheat protection |
| External Dimensions & Weight | 475 W × 383 D × 290 H mm |
| Brand | FD |
|---|---|
| Origin | Shanghai, China |
| Manufacturer | FD Catalyst Co., Ltd. |
| Model | FDGDC-1L |
| Design Pressure | 0.3 MPa |
| Maximum Operating Temperature | 750 °C |
| Catalyst Bed Volume | 1 L |
| Reactor Material | 316L Stainless Steel |
| Aspect Ratio (H/D) | ≥8:1 |
| Temperature Range | Ambient to 850 °C |
| Design Temperature | 900 °C |
| Feed Configuration | 1 Liquid + 5 Gas Inlets (N₂ purge included) |
| Gas Flow Rates | Air (30 NL/min), O₂ (6 NL/min), N₂ (24 NL/min), CH₄ (1 NL/min), H₂S (1 NL/min) |
| Control System | PLC + PC-based HMI |
| Optional Integrated Modules | Condenser + Gas-Liquid Separator + Online GC |
| Brand | Gongyi Yuyi Instrument |
|---|---|
| Origin | Henan, China |
| Model | MCR-3 |
| Microwave Frequency | 2450 MHz ±15 Hz |
| Microwave Output | Continuous wave, adjustable up to 800 W |
| Total Input Power | ≤1300 W |
| Temperature Control Range | Ambient to 250 °C |
| Temperature Control Accuracy | ±1 °C |
| Temperature Measurement Method | Contact-type PTFE-coated platinum resistance sensor (Class 0.2 accuracy) |
| Maximum Operating Pressure | Medium-pressure compatible (with optional vacuum accessory: –0.098 MPa) |
| Reaction Vessel Compatibility | 50–500 mL standard ground-glass joints (open-system configuration) |
| Construction Material | Stainless steel cavity and housing |
| Integrated Features | Built-in magnetic stirrer (stepless speed control), inert gas inlet port, ventilation/exhaust ducting, safety interlock door switch, magnetron overheat protection, multi-segment programmable operation (up to 5 segments), real-time temperature curve display, Flash memory parameter retention |
| Brand | Great Wall |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | GR-3L |
| Instrument Classification | Jacketed Glass Reactor |
| Usable Volume | 3 L |
| Vessel Material | Borosilicate Glass 3.3 |
| Operating Pressure Range | –0.1 to 0.0 MPa (gauge) |
| Vacuum Level | ≤ –0.098 MPa (absolute) |
| Jacket Pressure Rating | ≤ +0.03 MPa |
| Temperature Range | –80 °C to +200 °C |
| Stirring Speed | 50–500 rpm |
| Stirring Power | 70 W |
| Torque | 70 N·cm |
| Temperature Sensor | Pt100 (±0.1 °C accuracy) |
| Condenser Surface Area | ~0.025 m² |
| Constant-Pressure Funnel Capacity | 200 mL |
| Frame Material | SUS304 Stainless Steel |
| Sealing Material | PTFE |
| Electrical Supply | 110 V / 60 Hz or 220–240 V / 50–60 Hz |
| Dimensions (W×D×H) | ~480 × 420 × 1200 mm |
| Weight | Approx. 45 kg |
| Brand | Hanon |
|---|---|
| Origin | Shanghai, China |
| Model | UWave-2000 |
| Microwave Power | 0–1000 W (PID-controlled, non-pulsed continuous output) |
| Frequency | 2450 MHz (magnetron) |
| Temperature Control | Dual-mode (infrared: 0–300 °C, ±1 °C |
| Pt100 resistance probe | 0–250 °C, ±1 °C) |
| Pressure Control (sealed mode) | Piezoelectric sensor, 0–5 MPa, ±0.01 MPa |
| Max. Atmospheric Reaction Volume | 2000 mL (glass) |
| Max. Sealed Reaction Volume | 500 mL (stainless steel + PEEK/Quartz vessels) |
| Max. Sealed Operating Conditions | 230 °C, 2 MPa |
| Ultrasonic Module | Immersion-type, 0–800 W, 28 kHz, auto-sweep & frequency lock |
| UV Irradiation | Dual-source — standard 300 W @ 365 nm, optional 100 W @ 254 nm |
| Stirring | Dual-mode — magnetic (0–800 rpm), mechanical (30–1600 rpm, torque 300 N·m, PEEK or quartz shaft) |
| Safety Certification | ISO 9001:2008, CE compliant |
| Software | Windows-based PC interface with full parameter logging, real-time remote control, video capture, and audit-trail-capable data export |
| Brand | hte |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X2000 |
| Price Range | USD 1,500 – 150,000 (FOB Hamburg) |
| Brand | hte |
|---|---|
| Origin | Germany |
| Product Type | Imported Laboratory Catalyst Evaluation System |
| Model | X3000 Series Gas-Liquid Reaction System |
| Price Range | USD 1,500 – 150,000 (FOB Hamburg) |
| Brand | hte |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | X4500 |
| Pricing | Upon Request |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 1L Double-Jacketed Glass Reactor with Baffle Plate |
| Capacity | 1 L |
| Jacket Type | Dual vacuum-insulated jacket |
| Operating Temperature Range | −90 °C to +230 °C |
| Thermal Shock Limit (ΔT) | 60 °C |
| Pressure Range | 666 Pa (vacuum) to ambient pressure |
| Wetted Materials | Borosilicate glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4) |
| Max Stirring Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 22 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 1L Dual-Jacketed Reactor |
| Capacity | 1 L |
| Jacket Type | Dual (inner & outer thermal isolation) |
| Operating Temperature Range | −90 °C to +230 °C |
| Thermal Shock ΔT | 60 °C |
| Pressure Range | 666 Pa (vacuum) to ambient |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4) |
| Max Stirring Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 21 kg |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 1L Filtration Reactor |
| Vessel Capacity | 1 L |
| Jacketed Design | Yes |
| Operating Temperature Range | −90 °C to +200 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Operating Pressure Range | 666 Pa to ambient pressure |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4) |
| Maximum Agitator Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 28 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 5L Dual-Jacketed Baffle-Equipped Reactor |
| Capacity | 5 L |
| Jacket Type | Dual (inner heating/cooling jacket + outer vacuum insulation layer) |
| Operating Temperature Range | −90 °C to +230 °C |
| Thermal Shock Limit (ΔT) | 60 °C |
| Pressure Range | 666 Pa (0.5 mbar) to atmospheric pressure |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 ×1, TS 29/42 ×1, TS 24/40 ×4) |
| Max Stirring Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 28 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 5L Dual-Jacketed Reactor |
| Capacity | 5 L |
| Jacket Configuration | Dual (inner heating/cooling jacket + outer vacuum insulation jacket) |
| Operating Temperature Range | −90 °C to +230 °C |
| Maximum Thermal Shock ΔT | 60 °C |
| Operating Pressure Range | 666 Pa (0.5 mbar) to ambient |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 × standardized ground joints (SQG 29/42 ×1, TS 29/42 ×1, TS 24/40 ×4) |
| Max Stirring Speed | 800 rpm |
| Footprint | 380 mm × 380 mm |
| Height | 1206 mm |
| Net Weight | 28 kg |
| Compliance | Designed for GLP-compliant lab environments |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 5L Filter Reactor |
| Vessel Capacity | 5 L |
| Jacketed Design | Yes |
| Operating Temperature Range | −90 °C to +200 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Operating Pressure Range | 666 Pa to atmospheric |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 (SQG 29/42 × 1, TS 29/42 × 1, TS 24/40 × 4) |
| Maximum Agitator Speed | 800 rpm |
| Dimensions (W×D×H) | 380 mm × 380 mm × 1206 mm |
| Weight | 33 kg |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | 5L Pressurized Filtration Reactor |
| Vessel Capacity | 5 L |
| Construction | Single-layer borosilicate glass 3.3 vessel |
| Operating Temperature Range | −90 °C to +200 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Pressure Rating | Full vacuum to 0.2 MPaG (2 barg) |
| Wetted Materials | Borosilicate glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 × standardized ground joints (SQG 29/42 × 2, SQG 24/40 × 4) |
| Maximum Stirring Speed | 200 rpm |
| Dimensions (W × D × H) | 455 mm × 432 mm × 1206 mm |
| Weight | 39 kg |
| Modular Configuration | Integrated filtration & drying capability |
| Sealing System | Reinforced magnetic or mechanical shaft seal with leak-proof base design |
| Filtration Base | Removable, pressure-rated sintered frit or filter plate assembly |
| Accessories Included | Pt100 temperature probe, analog pressure gauge, pressure relief valve, quick-connect fluid ports with integrated shut-off valves, PTFE/FFKM-sealed discharge valve |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | AG! 1L Pressure Filtration Reactor |
| Vessel Capacity | 1 L (Note: corrected from misleading “5L” in description |
| Operating Temperature Range | −90 °C to +200 °C |
| Thermal Shock Resistance (ΔT) | 110 °C |
| Operating Pressure Range | Full Vacuum to 0.2 MPa (2 bar(g)) |
| Wetted Materials | Borosilicate Glass 3.3, PTFE, FFKM, FKM |
| Lid Ports | 6 × standardized ground joints (2 × SQG 29/42, 4 × SQG 24/40) |
| Max Stirring Speed | 200 rpm |
| Dimensions (W×D×H) | 455 mm × 432 mm × 1206 mm |
| Net Weight | 33 kg |
| Compliance | Designed per DIN 7080, EN ISO 15500-1, and CE Machinery Directive 2006/42/EC |
| Software Interface | None (standalone mechanical/electromechanical system) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | EasySyn 1000 Advanced |
| Reactor Type | Jacketed Glass Reactor |
| Usable Volume | 1 L |
| Operating Pressure Range | Low-pressure / Vacuum-compatible |
| Vacuum Level | 3 mbar |
| Construction Material | Borosilicate Glass 3.3 |
| Temperature Range | –50 °C to +200 °C |
| Stirrer Motor | EUROSTAR 100 control (Max. Torque: 100 N·cm) |
| Stirring Shaft Seal | High-integrity vacuum-rated mechanical seal |
| Vessel Fixation | DN 100 flange with FEP-coated O-ring |
| Lid Ports | 1 × NS 29/32 central, 2 × NS 29/32 lateral, 1 × NS 14/23 auxiliary |
| Drain System | LT 5.40 quick-drain module with valved thermal bath fluid lines |
| Control Interface | RS232 and USB |
| Software Integration | labworldsoft® 6 (optional external automation) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | EasySyn 1000 Advanced Reactor System |
| Rated Volume | 1 L |
| Minimum Usable Volume | 120 mL |
| Minimum Sample Volume with Temperature Sensor | 260 mL |
| Operating Temperature Range | −50 to 200 °C |
| Maximum Vacuum | 3 mbar (process), 25 mbar (seal rating) |
| Stirring Shaft Max Torque | 100 N·cm |
| Flange Size | DN 100 |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Interfaces | RS-232, Micro-USB |
| Jacket Drain System | LT 5.40 Quick-Drain Unit |
| Vessel Material | DIN 3.3 borosilicate glass |
| Bottom Valve | Spring-loaded PTFE-coated glass valve |
| Lid Ports | 1 × NS 29/32 central, 2 × NS 29/32 side, 1 × NS 14/23 |
| Stirrer | EUROSTAR 100 control with keyless chuck, integrated timer, overload protection & temperature input |
| Agitator Blade | PTFE-coated helical impeller |
| Seal Type | High-vacuum mechanical seal rated to 25 mbar |
| Software Control | labworldsoft® 6 (RS-232 optional) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Reactor |
| Model | EasySyn 1000 Starter |
| Vessel Capacity | 1 L |
| Vessel Material | Borosilicate Glass 3.3 |
| Operating Temperature Range | –50 °C to +200 °C |
| Maximum Vacuum | 3 mbar |
| Working Pressure | Low-pressure (up to 2 bar gauge, per IKA specification) |
| Stirring Torque | 60 N·cm |
| Flange Standard | DN 100 |
| Port Configuration | 1 × NS 29/32 (central), 2 × NS 29/32 (lateral), 1 × NS 14/23 |
| Sealing Material | FEP-coated O-ring |
| Valve Material | PTFE-lined bottom discharge valve |
| Stirrer Material | PTFE-coated helical impeller |
| Ambient Operating Conditions | 5–40 °C, ≤80% RH, ≤2000 m altitude |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | EasySyn 1000 Starter Reactor System |
| Rated Volume | 1 L |
| Minimum Usable Volume | 120 mL |
| Minimum Sample Volume with Temperature Sensor | 260 mL |
| Operating Temperature Range | −50 °C to +200 °C |
| Ultimate Vacuum | 3 mbar |
| Max. Stirring Torque | 60 N·cm |
| Flange Size | DN100 |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Jacketed Vessel Material | Borosilicate Glass 3.3 |
| Stirrer Type | Overhead Digital Motor (EUROSTAR 60 digital) |
| Sealing | Chemically Resistant FEP-Coated O-Ring & High-Vacuum Shaft Seal |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported |
| Model | EasySyn 2000 Advanced |
| Reactor Type | Jacketed Glass Reactor |
| Usable Volume | 2 L |
| Operating Pressure Range | Low-pressure (up to 25 mbar vacuum) |
| Ultimate Vacuum | 3 mbar |
| Temperature Range | –50 °C to +200 °C |
| Vessel Material | Borosilicate Glass 3.3 |
| Stirrer Motor | EUROSTAR 100 control, max. torque 150 N·cm |
| Stirring Shaft Seal | High-vacuum PTFE-sealed |
| Vessel Fixation | DN 150 clamp system with FEP-coated O-ring |
| Port Configuration | 1 × NS 29/32 central port, 2 × NS 29/32 side ports, 1 × NS 14/23 auxiliary port |
| Drain System | LT 5.40 quick-drain unit with integrated valves and thermostatic hose connections |
| Control Interface | RS232 and USB |
| Software Compatibility | labworldsoft® 6 (optional external automation) |
| Brand | IKA |
|---|---|
| Origin | Germany |
| Model | EasySyn 2000 Advanced Reactor System |
| Rated Volume | 2 L |
| Minimum Usable Volume | 120 mL |
| Minimum Sample Volume with Temperature Sensor | 400 mL |
| Operating Temperature Range | −50 to 200 °C |
| Ultimate Vacuum | 3 mbar (process vacuum), up to 25 mbar (seal rating) |
| Max. Stirring Torque | 100 N·cm |
| Flange Size | DN 150 |
| Dimensions (W × H × D) | 500 × 950 × 580 mm |
| Interfaces | RS-232, Micro-USB |
| Material | Borosilicate Glass 3.3 (DIN ISO 3585), FEP-coated O-rings, PTFE-coated impeller, stainless steel frame |