Synthesis/Reaction Equipment
Filter
Showing 151–180 of 234 results
| Brand | ZXYIQI |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | K-PSA-150ML |
| Price | ¥46,000 |
| Usable Volume | 150 mL (Small-scale) |
| Construction Material | Stainless Steel (304/316L standard) |
| Operating Pressure Range | Low-to-Medium Pressure (up to 30 MPa, per series specification) |
| Vacuum Capability | ≤ –0.1 MPa (gauge) |
| Heating Power | 0–2500 W |
| Temperature Range | 0–600 °C |
| Stirring Speed | 0–400 rpm |
| Motor | Brushless DC, 100 W |
| Sealing Options | Soft (PTFE/Gasket) or Hard (Metal-to-Metal) |
| Safety Features | Overpressure rupture disc (Hastelloy), overtemperature/over-time alarm, automatic pressure relief |
| Control System | Dual-loop PID temperature control, programmable ramp-soak profiles (optional), real-time data logging |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | CFRD |
| Price Range | USD 1,400 – 14,000 (FOB) |
| Maximum Operating Pressure | 10 MPa (100 bar) |
| Maximum Operating Temperature | 800 °C |
| Catalyst Bed Volume | 0.5–5 mL |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | FLB-4 |
| Price Range | USD 2,800 – 7,000 (FOB) |
| Chamber Capacity | Small-scale (≤50 mL typical use) |
| Operating Pressure | Low-pressure ambient environment |
| Vacuum Capability | Not applicable |
| Structural Material | Anodized aluminum housing with borosilicate glass viewport |
| Cooling System | Dual axial fans (rear-mounted, thermostatically regulated) |
| LED Mounting | Four fixed-position Kessil A365/A400-series compatible sockets (M4 threaded, 12 V DC input) |
| Power Input | 100–240 V AC, 50/60 Hz |
| IP Rating | IP20 (indoor laboratory use only) |
| Brand | LXTECH |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LX-EP1 |
| Price Range | USD 14,000 – 1.4 million |
| Brand | -- |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Regional Classification | Domestic |
| Model | Lynsys |
| Pricing | Upon Request |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MaxiClave |
| Price Range | USD 135,000 – 270,000 (FOB) |
| Usable Volume | Medium-scale |
| Construction Material | ASTM A276 Type 316 Stainless Steel |
| Maximum Operating Pressure | Up to 700 bar (HPII) / 1000 bar (custom) |
| Nominal Capacity | 1000 mL |
| Ultimate Vacuum | ≤ 1×10⁻⁵ Torr |
| Temperature Range | −269°C to 1300°C (model-dependent) |
| Heating Configuration | Hot-wall or cold-wall variants available |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasyMax 102 LT/ULT |
| Temperature Range | −90 °C to 150 °C |
| Temperature Control Accuracy | ±0.2 mK |
| Reaction Vessels | 1–10 units |
| Reaction Volume per Vessel | 8–100 mL |
| Cooling Method | Solid-State Thermoelectric (Peltier) |
| Real-Time Data Acquisition | Yes |
| Software Platform | iControl 6.1 |
| Low-Temperature Observation Capability | Yes (frost-free reactor wall down to −80 °C) |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasyMax/Optimax |
| Temperature Range | –40 to 180 °C |
| Temperature Control Accuracy | ±0.2 mK |
| Reaction Vessels | 1–10 units |
| Reaction Volume Capacity | 8 mL to 1000 mL |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasyMax™ 102 HFCal |
| Temperature Range | –40 to 180 °C |
| Temperature Control Accuracy | ±0.2 mK |
| Reaction Vessel Capacity | 8–1000 mL |
| Number of Reaction Units | 1–10 |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | EasySampler 1210 |
| Temperature Range | –20 °C to 140 °C |
| Sample Type Compatibility | Homogeneous, heterogeneous, slurry, air- and moisture-sensitive, exothermic/hazardous reactions |
| Compliance | Designed for GLP/GMP-aligned workflows, supports 21 CFR Part 11–compliant data integrity when integrated with iC Software Suite |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | OptiMax™ |
| Temperature Range | −40 to 180 °C (jacket) |
| Temperature Control Accuracy | ±0.2 mK |
| Reaction Vessels | 1–10 units |
| Vessel Volume | 8–1000 mL |
| Stirring Speed | 30–1200 rpm (±5 rpm) |
| Dimensions | 388 × 414 × 539 mm (W × D × H) |
| Weight | 35 kg |
| Brand | METTLER TOLEDO |
|---|---|
| Origin | Switzerland |
| Model | RX-10 |
| Application Scope | Jacketed laboratory reactors (mL to L scale) |
| Integrated PAT Compatibility | In-situ pH, FTIR, FBRM, PVM, particle size analysis |
| Control Interface | Touchscreen + iC/iControl software suite |
| Regulatory Support | 21 CFR Part 11 compliant audit trail, electronic signature, data integrity features |
| Thermal Control Integration | Compatible with external chillers, heaters, and circulators |
| Data Acquisition | Synchronized timestamped logging of temperature, stirring speed, dosing volume, pH, and PAT sensor streams |
| Brand | NAI Instruments |
|---|---|
| Origin | Shanghai, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | NAAI-DMH |
| Pricing | Available Upon Request |
| Brand | NAI |
|---|---|
| Origin | Shanghai, China |
| Model | NAI-WBC6 / NAI-WBC12 |
| Sample Capacity | 6 or 12 vessels |
| Vessel Material | PTFE inner + PEEK outer |
| Inner Volume | 100 mL per vessel |
| Temperature Range | 0–300 °C |
| Temp. Control Accuracy | ±0.5 °C |
| Pressure Range | 0–10 MPa |
| Microwave Output | 0–1600 W, continuous auto-frequency modulation |
| Safety features | self-locking anti-explosion door, rupture disc + pressure relief valve, real-time fault diagnostics, automatic microwave cutoff on overpressure/overtemperature |
| Cooling | forced-air circulation ≥5 m³/min, integrated cavity air-cooling |
| Display | 8″ industrial touch HMI (Siemens PLC-based) |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Type | Imported Laboratory Cascade Reactor System |
| Model | 4-Stage Cascade Synthesis Reactor |
| Pricing | Available Upon Request |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Capacity | 50 L (adjustable range: 0.25 L to 200 L) |
| Construction Material | DIN 7080 / ISO 3585 borosilicate glass 3.3 (BSG 3.3) |
| Operating Pressure Range | -0.1 MPa (full vacuum) to +0.3 MPa (gauge) |
| Temperature Range | -30 °C to +200 °C |
| Contact Materials | BSG 3.3 and PTFE only |
| Modular Control Interface | Analog & digital I/O for temperature, pressure, stirring speed, and pH/DO sensors |
| Compliance | CE-marked, conforms to EN 61000-6-3 (EMC), EN 61000-6-2 (immunity), and DIN 12573 Part 1 (laboratory glassware standards) |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | 50L Reactor-Distillation System |
| Construction Material | Borosilicate Glass 3.3 (Duran®) |
| Vessel Volume | 50 L |
| Heating/Cooling | Thermostatic Oil Circulation Bath with Jacket |
| Vacuum Compatibility | High-vacuum capable (≤1 mbar) |
| Bottom Valve | PTFE-sealed pneumatic discharge valve, zero-dead-volume design |
| Sensors | Integrated pH and Pt100 temperature probes |
| Automation | PC-based control unit with real-time data acquisition and process logging |
| Compliance | ISO 719-HGB1, ISO 720-HGA1, ISO 1776, ISO 695-A |
| Modular Interface Standard | DIN 2817 / ISO 2853 flange system |
| Stirring System | Explosion-proof magnetic or overhead drive, variable speed (0–250 rpm) |
| Distillation Assembly | Packed or structured packing column, reflux condenser with phase separation, fraction receiver with automated switching |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Model | Normag |
| Type | Falling-Film Photochemical Reactor with Dual Thermal Management |
| Cooling/Heating Interface | External Circulating Oil Bath (via Inner Jacket) |
| Vacuum Insulation | Silver-Coated High-Vacuum Outer Jacket |
| Light Source Configuration | Central Axial Lamp Assembly |
| Flow Control | Integrated Peristaltic or Diaphragm Circulation Pump |
| Sample Introduction | Modular Inlet with Counter-Current Gas Sparging |
| Compliance | Designed for ISO/IEC 17025-aligned lab environments, compatible with GLP documentation workflows |
| Brand | NORMAG |
|---|---|
| Origin | Germany |
| Construction Material | Borosilicate Glass 3.3 (DIN ISO 3585) |
| Pressure Rating | Up to 0.5 bar(g) |
| Volume Range | 2 L – 20 L (Standard Configurations) |
| Design Standard | DIN 1561 / DIN 28120 / ASTM E438 Type I, Class A |
| Sealing System | PTFE-Coated Ground Glass Joints (ISO 2768-fine Tolerance) |
| Drive Type | Digital Speed-Controlled DC Motor with Torque Monitoring |
| Temperature Range | –80 °C to +200 °C (with Compatible Circulating Chiller/Heater) |
| Brand | Ahkemi |
|---|---|
| Origin | Anhui, China |
| Model | NSV Plus |
| Vessel Capacity | 25 mL, 50 mL, 100 mL, 300 mL, 500 mL |
| Maximum Operating Pressure | 10 MPa |
| Maximum Operating Temperature | 300 °C |
| Heating Method | Embedded Stainless Steel Heating Module (1 kW) |
| Stirring Speed Range | 100–1200 rpm |
| Stirring Type | Internal Magnetic Stirring |
| Construction Material | Standard 316L Stainless Steel (Hastelloy C-276, Titanium TA2, Zirconium 702, Inconel 600, and other alloys available upon request) |
| Viewport | Sapphire Crystal Window (26 mm clear aperture for 25–50 mL |
| Sealing System | Dual-axis sealing with DuPont Kalrez perfluoroelastomer O-rings |
| Safety Systems | Integrated MEAS pressure transducer, Ashcroft analog pressure gauge, Swagelok inlet/outlet needle valves, Fitok safety relief valve + custom rupture disc, overtemperature cutoff, audible overpressure alarm |
| Control Interface | 7-inch capacitive touchscreen (real-time display of temperature, pressure, stirring speed, elapsed time) |
| Compliance | Designed to meet ASME BPVC Section VIII Div. 1 design principles |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | Parr Modular Reaction System (MRS) with 16-Station High-Throughput Configuration |
| Reactor Type | Benchtop Batch/Parallel Autoclave Reactor |
| Heating Method | Electric Cartridge Heaters with Aluminum Block Thermal Management |
| Control Architecture | Dual 4871 Process Controllers with 16 × 4875 Power Modules |
| Pressure Rating | Up to 2000 psi (13.8 MPa) |
| Temperature Range | Ambient to 350 °C |
| Vessel Capacity | Standard 4560 Microreactors (25–100 mL) |
| Stirring | Magnetic or Mechanical Drive Options |
| Safety Features | Rupture Discs, Pressure Relief Valves, Interlocked Access Doors |
| Compliance | Designed per ASME BPVC Section VIII Div. 1, CE Marked for EU Lab Use |
| Software Interface | Parr PC-Based Control Suite (Supports ASTM E2500-19, FDA 21 CFR Part 11 Audit Trail & Electronic Signature Ready) |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 3900 Series |
| Operating Pressure | Up to 5 atm |
| Max. Temperature | 80 °C |
| Drive Mechanism | Motorized Oscillating Motion |
| Heating Method | External Electric Heating Jacket |
| Temperature Control | PID Controller with Internal Thermocouple Feedback |
| Safety Certification | Explosion-Proof Options Available |
| Compliance | Designed for GLP-compliant hydrogenation research in pharmaceutical development |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 4500 Series |
| Vessel Capacity | 0.075–2 L |
| Construction Material | 316 Stainless Steel |
| Maximum Operating Pressure | 3000–5000 psi (207–345 bar) |
| Vacuum Capability | Yes (rated for full vacuum to full positive pressure) |
| Drive Type | Magnetic Coupling or Gear-Driven Stirring |
| Temperature Range | Up to 540 °C |
| Certifications | ASME Section VIII Div. 1, UL/cUL, CSA, CE, ISO 9001 |
| Brand | PARR |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | 4520 |
| Volume Range | 1000 mL – 2000 mL |
| Maximum Operating Pressure | 130 atm (13.2 MPa) |
| Maximum Operating Temperature | 350 °C |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Vacuum Capability | Not Designed for Vacuum Service |
| Regulatory Compliance | Compliant with ASTM G187 (High-Pressure Reaction Vessel Safety), FDA-relevant design principles for pharmaceutical process development |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4530 Series |
| Vessel Capacity | 1000 mL / 2000 mL |
| Max Operating Temperature | 350 °C |
| Max Operating Pressure | 130 atm (13.2 MPa) |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 4540 Series |
| Vessel Capacity | 600 mL / 1200 mL |
| Max Operating Temperature | 350 °C |
| Max Operating Pressure | 345 atm (5000 psi) |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |
| Configuration | Benchtop & Floor-Standing Options |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4550 Series |
| Volume Options | 3.75 L (1 gal) and 7.5 L (2 gal) |
| Max Operating Temperature | 350 °C |
| Max Operating Pressure | 130 atm |
| Construction Materials | 316 Stainless Steel, Hastelloy® C-276, Hastelloy® C-2000 |
| Certifications | ASME BPVC Section VIII Div. 1, CSA, CE, uV, ISO 9001 |
| Brand | Parr |
|---|---|
| Origin | USA |
| Manufacturer Authorization | Authorized Distributor |
| Import Status | Imported |
| Model | 4555 Series |
| Price Range | USD $130,000–$260,000 (FOB) |
| Usable Volume | 10 L to 18.75 L |
| Maximum Operating Pressure | 130 atm (13.2 MPa) |
| Maximum Operating Temperature | 350 °C |
| Construction Materials | 316 Stainless Steel, Hastelloy C-276, Hastelloy C-2000 |
| Vacuum Capability | Not rated for vacuum service |
| Certification | ASME Section VIII Div. 1, UL/cUL Listed (uV), ISO 9001:2015, CSA C22.2 No. 61010-1, CE Marked |
| Brand | PARR |
|---|---|
| Origin | USA |
| Model | 4560 Pressure Stirred Autoclave |
| Volume Range | 100–600 mL (Models 4561–4568) |
| Max Operating Pressure | 200 bar |
| Max Operating Temperature | 225–350 °C |
| Configuration | Benchtop Miniature Autoclave System |
| Certification | ASME BPVC Section VIII Div. 1 Compliant Vessels |
| Drive Type | Magnetically Coupled or Mechanical Seal Stirring Assembly |
| Brand | Parr |
|---|---|
| Origin | USA |
| Model | 4590 Series |
| Working Pressure | Up to 575 bar |
| Maximum Temperature | Up to 600 °C |
| Vessel Volume Options | 25 mL – 18.75 L |
| Construction Materials | ASTM-certified alloys (e.g., 316 SS, Hastelloy C-276, Inconel 600, Titanium Grade 2, Zirconium), borosilicate glass, or PTFE-lined configurations |
| Stirring Options | Magnetic drive (0–1800 rpm), gear-driven, pneumatic, or explosion-proof motorized agitators |
| Heating Methods | Electric heating mantle, aluminum block heater, steam/oil jacket |
| Closure Types | Clamp-style (open-loop) or threaded (screw-cap) head design |
| Certifications | ASME Section VIII Div. 1, CSA, CE, ISO 9001, uV Listed |