Temperature & Humidity Detector
Filter
Showing 1–30 of 164 results
| Brand | ACM |
|---|---|
| Origin | Austria |
| Model | TS.60 |
| Power Supply | 24 VDC / 1 W |
| Output Signal | RS-485 |
| Measurement Range | 0–100 °C |
| Accuracy | ±0.1 °C |
| Principle | Infrared Radiation Thermometry |
| Compliance | CE, RoHS, EN 61326-1 (EMC for Industrial Environments) |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | B17-HP |
| Temperature Accuracy | ±0.3°C |
| Temperature Resolution | 0.01°C |
| Response Time Constant | 5 s |
| Operating Temperature Range | 0–30°C |
| Supply Voltage | 6–28 VDC |
| Max Current Draw | 30 mA |
| Output Protocols | NMEA 0183 / NMEA 2000® |
| Output Sentence | YXMTW (NMEA 0183), PGN 130310 (NMEA 2000®) |
| Mounting Hole Diameter | 51 mm |
| Housing Material Options | Bronze, Stainless Steel, Plastic |
| Profile Height | 5 mm |
| Cable Length (Max) | 100 m |
| Weight | 1.3 kg |
| Brand | Airmar |
|---|---|
| Origin | USA |
| Model | HT200 |
| Temperature Range | 0–30°C |
| Accuracy | ±0.3°C |
| Resolution | 0.01°C |
| Response Time | 0.15 s |
| Output Protocol | NMEA 2000® |
| Update Rate | 2 Hz |
| Supply Voltage | 9–50 VDC |
| Current Draw | ≤30 mA |
| Cable Length | 6 m |
| Housing Compatibility | P17, B17, SS577 |
| Mounting Hole Diameter | 51 mm |
| NMEA 2000 LEN | 1 |
| Weight (Bronze) | 1.3 kg |
| Weight (Stainless Steel) | 1.6 kg |
| Brand | Amensio |
|---|---|
| Origin | Germany |
| Model | Sens-o-Spheres |
| Dimensions | Ø9 mm |
| Mass | 0.5 g |
| Wireless Communication | 2.4 GHz ISM band |
| Operating Temperature Range | –20 °C to +120 °C (typical for sterilizable variants) |
| Max Concurrent Sensors per Gateway | 24 |
| Compliance | CE, RoHS, IP67 (sensor housing) |
| Material | Biocompatible PEEK or medical-grade stainless steel (depending on variant) |
| Brand | AMETEK JOFRA |
|---|---|
| Origin | Denmark |
| Instrument Type | Dry-Block Calibrator |
| Temperature Range | −100 °C to 1205 °C |
| Models | RTC, PTC, CTC, MTC, ETC Series |
| Accuracy (typ.) | ±0.04 °C to ±0.5 °C |
| Stability (typ.) | ±0.005 °C to ±0.1 °C |
| Display | Full-color touchscreen interface |
| Control Architecture | Active dual-zone or triple-zone thermal control (RTC), MVI active power fluctuation immunity (CTC/MTC), DLC dynamic load compensation (RTC) |
| Compliance | Designed for ISO/IEC 17025-accredited calibration labs |
| Brand | Ametek JOFRA |
|---|---|
| Origin | Denmark |
| Product Type | Reference-Grade Dry-Block Temperature Calibrator |
| Model | RTCt Series |
| Temperature Range | –35 °C to 125 °C (standard block), –35 °C to 660 °C (with optional high-temp block) |
| Display | 7-inch full-color capacitive touchscreen with customizable UI |
| Connectivity | USB, Ethernet, Wi-Fi (IEEE 802.11 b/g/n) |
| Dual Sensor Inputs | Yes (simultaneous dual-channel reference and UUT monitoring) |
| Auto Ramp/Soak Control | Full rate control across all operating modes (ramp, soak, switch, multi-step) |
| Preset Temperatures | Up to 6 user-defined setpoints with nameable calibration profiles |
| Graphical Stability Monitoring | Real-time dual-mode visualization (absolute temperature vs. stability threshold → automatic transition to delta-T relative mode upon stabilization) |
| Multi-Step Switch Calibration | Up to 5 sequential temperature switches per automated sequence |
| Compliance | Designed for ISO/IEC 17025 accredited labs |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | AP-400 / AP-450 |
| Input Channels | 1 (Thermocouple) |
| Thermocouple Types Supported | AP-400 — E or K only |
| Measurement Range | E: −200 to +800 °C |
| K | −200 to +1370 °C |
| J | −200 to +1100 °C |
| T | −200 to +400 °C |
| R | 0 to +1760 °C |
| Resolution | 0.1 °C (within specified ranges), auto-switches to 1 °C outside |
| Accuracy | ±(0.05% of reading + 0.2 °C) for E/K/J/T at 0–100 °C |
| Reference Junction Compensation Accuracy | ±0.2 °C at 25 ±10 °C |
| Temp. Coefficient | ±0.01% of range per °C outside 25 ±10 °C |
| Operating Environment | 0–40 °C, 0–80% RH (non-condensing) |
| Storage | −20 to +50 °C, 0–85% RH (non-condensing) |
| Sampling Rate | 2 Hz (no print), down to 1 sample/min (interval modes) |
| Battery Life | Up to 120 hours (1-min interval, no print) |
| Power | 4 × AA alkaline batteries (included) or optional AC adapter (AD-100/115/220-500-HR-R) |
| Display | LCD |
| Printer | Thermal line printer, 2.5 mm character height, 37 mm paper width, 1000 lines per roll |
| Memory Capacity | 100 data records |
| Data Output | Absolute timestamp (HH:MM:SS), sequential numbering, batch print |
| Linearization | Digital, compliant with IEC 60584-1:2013 |
| Dimensions | ~68 × 201 × 42 mm (W×H×D, excl. protrusions) |
| Weight | ~350 g (incl. batteries) |
| Backup Power | Rechargeable lithium cell (real-time clock only) |
| Accessories Included | Carrying pouch, 4 × AA alkaline batteries, paper holder, user manual, ACAP4 thermal paper (1 roll), calibration report, registration card |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | AR-6500H / AR-6501H |
| Measurement Principle | Radiation-based (Infrared) + Contact (Thermocouple) |
| Measurement Modes | Non-contact IR + K-type thermocouple contact |
| Temperature Range (IR) | –50.0 to 500.0 °C (AR-6500H), 0 to 1200 °C (AR-6501H) |
| Temperature Range (Contact) | –50.0 to 500.0 °C (K-type, ≤500 Ω) |
| Resolution | 0.1 °C (–50.0 to 525.0 °C display range), 1 °C (up to 1250 °C) |
| Accuracy (IR, AR-6500H) | ±3 °C (<0 °C), ±2 °C (0–250 °C), ±0.8% of reading +1 digit (250–500 °C) |
| Accuracy (Contact, K-type) | ±(0.05% of reading + 0.1 °C) ±1 digit |
| Emissivity Adjustment Range | 0.10–2.00 (0.01 step) |
| Spectral Response | 8–14 µm |
| Detector | Thermopile |
| Response Time | ≈300 ms |
| Laser Targeting | Integrated Class II red laser (650 nm) |
| Repeatability | ±0.4% of reading +1 digit |
| Reference Junction Compensation Accuracy | ±0.2 °C (at 25 °C ±10 °C) |
| Temperature Coefficient | ±0.01% / °C of measured range |
| Analog Output | –1 mV/°C (optional, sensor sold separately) |
| Output Accuracy | ±(0.15% FS + 1 mV) at 25 °C ±5 °C |
| Power | Rechargeable Ni-Cd battery |
| Operating Time | >30 hours per full charge (varies with usage) |
| Operating Environment | 0–40 °C, 0–80% RH (non-condensing) |
| Storage Environment | –20–50 °C, 0–85% RH (non-condensing) |
| Dimensions | As per manufacturer’s mechanical drawing |
| Weight | Approx. 400 g |
| Compliance | IEC 60584-1:2013 (K-type linearization), CE marking, RoHS compliant |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1100E / HD-1100K |
| Measurement Range | E-type: −200 to +800°C |
| K-type | −200 to +1370°C |
| Accuracy | ±(0.05% of reading + 0.2°C) at 0°C (0.1°C resolution range) |
| Resolution | 0.1°C (−104.9 to +504.9°C for both E & K), otherwise 1°C |
| Waterproof Rating | IPX5 |
| Display | Large LCD |
| Power | 4 × AA alkaline batteries (300 h typical life) |
| Data Logging | Up to 9999 records, 9 programmable intervals, manual trigger, playback & PC transfer via AMS-100 software |
| Compliance | CE, RoHS |
| Operating Environment | 0–40°C, 0–80% RH (non-condensing) |
| Dimensions | 76 × 167 × 36 mm (W×H×D) |
| Weight | ~350 g (incl. batteries) |
| Input | Single-channel thermocouple (E or K type), integrated cold-junction compensation, max input resistance 500 Ω |
| Sampling Rate | ~300 ms |
| Linearization | Digital, compliant with IEC 60584-1:2013 |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1150E / HD-1150K |
| Temperature Range (E-type) | −200 to +800 °C |
| Temperature Range (K-type) | −200 to +1370 °C |
| Resolution | 0.1 °C (−104.9 to +504.9 °C), 1 °C elsewhere |
| Accuracy (0.1 °C range, ≥0 °C) | ±(0.05% of reading + 0.2 °C) |
| Accuracy (0.1 °C range, <0 °C) | ±0.5 °C |
| Reference Junction Compensation Accuracy | ±0.2 °C (at 25 °C ±10 °C) |
| IP Rating | IPX5 |
| Display | Backlit LCD |
| Battery Life | Up to 300 hours (4 × AA alkaline) |
| Dimensions | 76 × 167 × 36 mm (W×H×D) |
| Weight | ~350 g (including batteries) |
| Compliance | CE, RoHS, IEC 60584-1:2013 |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1250E / HD-1250K |
| Temperature Range (E-type) | −200 to 800 °C |
| Temperature Range (K-type) | −200 to 1370 °C |
| Accuracy (0 °C, 0.1 °C resolution) | ±(0.05% of reading + 0.2 °C) |
| Accuracy (0 °C, 1 °C resolution) | ±(0.1% of reading + 1 °C) |
| Reference Junction Compensation Accuracy | ±0.2 °C at 25 °C |
| Temperature Coefficient | ±0.01% F.S./°C |
| IP Rating | IPX5 |
| Display | Backlit LCD |
| Power | 4 × AA alkaline batteries (300 h typical life) |
| Dimensions | 76 × 167 × 36 mm (W × H × D) |
| Weight | ~350 g (incl. batteries) |
| Compliance | CE, RoHS |
| Input | Single-channel thermocouple (E or K type), ANP connector |
| Linearization | Digital, compliant with IEC 60584-1:2013 |
| Sampling Rate | ~300 ms |
| Data Logging | Up to 9999 records, programmable interval (9 options), manual trigger, peak/valley hold, playback, PC transfer via AMS-100 software |
| Brand | Anritsu Meter |
|---|---|
| Origin | Japan |
| Model | HD-1350E / HD-1350K |
| Temperature Range (E-type) | −200 to 800 °C |
| Temperature Range (K-type) | −200 to 1370 °C |
| Resolution | 1 °C or 0.1 °C (auto-switching) |
| Accuracy (0.1 °C mode) | ±(0.05% of reading + 0.2 °C) from 0 °C |
| Reference Junction Compensation Accuracy | ±0.2 °C at 25 °C ±10 °C |
| Sampling Rate | ~300 ms |
| Input | Single-channel thermocouple (E or K standard |
| Display | Backlit LCD |
| Power | 4 × AA alkaline batteries (300 h typical life) or optional AC adapter |
| IP Rating | Waterproof housing (IEC 60529 IP54 equivalent) |
| Compliance | CE, RoHS |
| Dimensions | 76 × 167 × 36 mm (W×H×D, excl. protrusions) |
| Weight | ~350 g (incl. batteries) |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer | Anton Paar GmbH |
| Product Type | Imported Precision Resistance Thermometer |
| Model | MKT 50 |
| Temperature Range | −260 °C to +962 °C (−436 °F to +1764 °F) |
| Resistance Range | approx. 0 Ω to 440 Ω |
| Temperature Accuracy | ±0.0001 °C (±0.1 mK) for Pt100 |
| Resistance Accuracy | < 0.4 mΩ |
| Resolution | 40 μΩ (0.1 ppm full scale) |
| Operating Ambient Temperature | 0 °C to 35 °C (32 °F to 95 °F) |
| Display | Graphic LCD with LED backlight, 128×64 dots (≈65 mm × 35 mm) |
| Power Supply | 2 × AA batteries (1.2–1.5 V) or AC adapter: 100–240 VAC, 50/60 Hz, output 7.5 VDC, 5.34 A, max 40 W |
| Dimensions | 240 mm × 190 mm × 110 mm |
| Weight | 2 kg |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | MI Series Handheld Infrared Radiometer |
| Field of View (FOV) | MI-210: 22° half-angle |
| MI-220 | 18° half-angle |
| MI-2H0 | 32° horizontal half-angle, 13° vertical half-angle |
| Spectral Range | 8–14 µm |
| Accuracy | ±0.3 °C (−30 to +65 °C, target–detector ΔT ≤ 20 °C) |
| Repeatability | ±0.1 °C |
| Stability | <2% per year |
| Response Time | 0.6 s |
| Operating Environment | 0–50 °C, 0–90% RH (non-condensing) |
| Instrument Dimensions | 126 × 70 × 24 mm |
| Sensor Dimensions | Ø23 × 60 mm |
| Weight | 270 g (with radiation shield) |
| Cable Length | 2 m |
| Warranty | 4 years |
| Brand | Apogee Instruments |
|---|---|
| Origin | USA (Manufactured in Logan, UT) |
| Model | SI-111 |
| Output Type | Analog Voltage (Non-Amplified) |
| Field of View | 22°30′ |
| Spectral Range | 8–14 µm |
| Measurement Range | −60 °C to +110 °C |
| Calibration Uncertainty | ±0.2 °C (−20 °C to +65 °C) |
| Response Time (95%) | 0.6 s |
| Sensitivity | 60 µV/°C |
| Thermopile Output Range | −3.3 mV to +3.3 mV |
| Thermistor Output Range | 0–2500 mV (excitation-dependent) |
| Excitation Voltage | 2500 mV (typ.) |
| Operating Environment | −55 °C to +80 °C, 0–100% RH (non-condensing) |
| Housing | Marine-grade stainless steel (IP68 connector at sensor head) |
| Dimensions | Ø23 mm × 60 mm |
| Mass | 190 g (incl. 5 m cable) |
| Cable | 5 m, 4-conductor, shielded twisted-pair, TPR jacket (UV-stable, hydrophobic, low-temp flexible) |
| Long-term Drift | <2% per year (with clean germanium window) |
| Warranty | 4 years |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model Variants | SI-111, SI-121, SI-131, SI-1H1, SI-411 |
| Output Type | Analog Voltage (SI-1xx) / SDI-12 Digital (SI-4xx) |
| Field of View | 22.5° (SI-111/SI-411), 5° (SI-121/SI-421), 1° (SI-131/SI-431), 180° horizontal (SI-1H1/SI-4H1) |
| Spectral Range | 8–14 µm |
| Measurement Range | –60 °C to +110 °C |
| Calibration Uncertainty | ±0.2 °C (–20 °C to +65 °C), ±0.5 °C (–40 °C to +80 °C) |
| Response Time (95%) | 0.6 s |
| Sensitivity | 60 µV/°C |
| Operating Environment | –55 °C to +80 °C, 0–100% RH (non-condensing) |
| IP Rating | IP68 connector |
| Cable | 5 m, 4-conductor shielded twisted-pair, TPR jacket |
| Mass | 190 g (incl. cable) |
| Warranty | 4 years |
| Brand | Apogee |
|---|---|
| Origin | USA |
| Model | SIL-411 |
| Field of View (Half-Angle) | 22° |
| Measurement Range | 0 to 50 °C |
| Accuracy (0–50 °C, target and sensor within 20 °C) | ±0.5 °C |
| Repeatability | <0.05 °C |
| Long-Term Drift | <2 %/year |
| Response Time | 0.6 s |
| Spectral Range | 8–14 µm |
| Operating Environment | −50 to 80 °C |
| Dimensions | Ø23 mm × 60 mm |
| Weight | 190 g (including 5 m cable) |
| Cable | 5 m, 4-conductor shielded twisted pair with TPR jacket |
| Warranty | 4 years |
| Brand | AS ONE |
|---|---|
| Origin | Taiwan |
| Manufacturer Type | Manufacturer |
| Country of Origin | China (Domestic) |
| Model No. | 1-5812-01 |
| Temperature Range | -50 to +1300 °C |
| Resolution | 0.1 °C / 1 °C (switchable) |
| Display | 3.5-digit LCD with backlight |
| Accuracy | ±0.3% rdg + 1 °C (-50 to +1000 °C) |
| Sampling Rate | 2.5 readings/sec |
| Power Supply | 1 × 006P (9 V) battery (included) |
| Dimensions | 155 × 65.5 × 35 mm |
| Weight | 177 g |
| Thermocouple Type | K-type |
| Functions | Data Hold, Max Value Storage & Recall, Auto-Hold Trigger |
| Brand | AS ONE |
|---|---|
| Model | 2-3799-01 |
| Type | Digital Thermometer (Waterproof) |
| Display | LED |
| Dimensions | 70 × 40 × 175 mm |
| Compliance | RoHS 2 (EU Directive 2015/863) |
| Origin | China |
| Manufacturer | AS ONE (AS ONE Co., Ltd.) |
| Instrument Category | Temperature Measuring Instrument |
| Brand | ASP / Advanced Sensing Products |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrumentation |
| Model | YKF Series |
| Instrument Class | Temperature Verification and Calibration System |
| Temperature Range | –260 °C to +850 °C |
| Nominal Resistance at 0.01 °C | 25.5 Ω or 100 Ω (per model) |
| TCR (Temperature Coefficient of Resistance) | 0.003850 Ω/Ω/°C or 0.003925 Ω/Ω/°C |
| Long-Term Stability | <0.0025 °C/year @ 0 °C |
| High-Temperature Drift (500 h) | <0.006 °C @ 500 °C |
| Repeatability | <0.0005 °C (–260 °C to 260 °C, 20 cycles) |
| Probe Diameter | 3.2 mm (standard sensing tip) |
| Standard Sheath Diameters | 4.78 mm or 6.35 mm |
| Standard Length | 305 mm |
| Vibration Resistance | 20 G, 10–2000 Hz |
| Standard Connector | 6-pin |
| Optional Connectors | Spade terminals, 5-pin DIN, 2-pin DIN, 4-pin DIN |
| Brand | ASP/Advanced Sensing Products |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | YKF200 |
| Instrument Type | Temperature Verification and Calibration System |
| Temperature Range | −260 °C to +260 °C |
| Nominal Resistance | 25.5 Ω or 100 Ω at 0 °C |
| TCR (α) | 0.003850 Ω/Ω/°C or 0.003925 Ω/Ω/°C |
| Stability Drift | <0.0025 °C/year at 0 °C |
| Repeatability (R₀) | <0.0005 °C over 20 consecutive cycles across full range |
| Vibration Resistance | 20 G, 10–2000 Hz |
| Dimensions | Ø3.2 mm × 9.7 mm |
| Fill Gas | Dry Helium |
| Sheath Material | Gold-Plated Copper |
| Primary Application | NIST-Traceable Cryogenic Reference Standard |
| Brand | ASP / Advanced Sensing Products |
|---|---|
| Origin | USA |
| Model | YKI Series |
| Temperature Range | −200 °C to 1100 °C |
| Resistance at 0 °C | 10 Ω, 100 Ω, 500 Ω, or 1000 Ω (customizable) |
| TCR (α) | 0.003850 Ω/Ω/°C |
| Accuracy Class | IEC 60751 DIN Class A (±0.06 °C at 0 °C) or Class B (±0.12 °C at 0 °C) |
| Stability | R₀ drift < 0.002 °C after 1000 h at 300 °C |
| Repeatability | R₀ deviation < 0.002 °C over 100 cycles (25–300 °C) |
| Thermal Hysteresis | < 0.001 °C (−196 °C to 300 °C) |
| Sheath Material | Stainless steel or Inconel® alloy |
| Standard Diameter | 3–6.35 mm |
| Standard Length | 305–457 mm (12–18 in) |
| Vibration Resistance | 20 g from 10–5000 Hz |
| Brand | ASP / Advanced Sensing Products |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | YKI1100 |
| Instrument Class | Temperature Verification and Calibration System |
| Temperature Range | −200 °C to 1100 °C |
| Nominal Resistance | 10 Ω or 100 Ω (customizable at 0.01 °C reference) |
| Temperature Coefficient of Resistance (TCR) | 0.003850 Ω/Ω/°C |
| Stability | ΔR₀ < 0.1 °C after 100 h continuous exposure at 1100 °C |
| Repeatability | ΔR₀ < 0.020 °C over 10 consecutive cycles from 25 °C to 1100 °C |
| Shock & Vibration Resistance | Withstands 20 G acceleration across 10–5000 Hz frequency range |
| Standard Probe Dimensions | Ø6.35 mm × 450 mm (custom lengths/diameters available) |
| Brand | ASP/Advanced Sensing Products |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | YKS Series |
| Instrument Type | Temperature Verification and Calibration System |
| Temperature Range | -250 °C to +850 °C |
| Nominal Resistance at 0.01 °C | 25.5 Ω or 100 Ω (customizable) |
| Temperature Coefficient of Resistance (TCR) | 0.003850 Ω/Ω/°C or 0.003925 Ω/Ω/°C |
| Accuracy Class | IEC 60751 DIN Class A (±0.06 °C), Class B (±0.12 °C), or W(Ga) ≥ 1.11807 |
| Long-Term Stability | R₀ drift < 0.002 °C after 1000 h at 300 °C |
| Repeatability | R₀ deviation < 0.005 °C over repeated cycling from −196 °C to +850 °C |
| Probe Housing Material | Inconel® alloy (nickel-chromium) |
| Standard Probe Dimensions | Ø 0.188" (4.78 mm), Ø 6 mm, or Ø 0.25" (6.35 mm) |
| Vibration Resistance | Withstands 20 G acceleration across 10–2000 Hz |
| Brand | ASP/Advanced Sensing Products |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | YKS500 Series |
| Instrument Category | Standard Platinum Resistance Thermometer (SPRT) |
| Temperature Range | −200 °C to +500 °C |
| Nominal Resistance | 25.5 Ω or 100 Ω (customizable) |
| Temperature Coefficient | α = 0.003850 Ω/Ω/°C or 0.003925 Ω/Ω/°C (IEC 60751 / ASTM E1137 compliant) |
| Stability (25–500 °C, 100 thermal cycles) | R₀ drift < 0.008 °C |
| Repeatability (25–500 °C, 100 cycles) | R₀ deviation < 0.008 °C |
| Vibration Resistance | 20 G, 10–2000 Hz |
| Probe Diameter | 4.78 mm (0.188″) or 6.35 mm (0.25″) |
| Probe Length | 305–457 mm (12–18″), customizable |
| Brand | AUCMA |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | AKMS-03 (Standard Temp/Humidity Logger), AKMB-03D (Cryogenic Sensor Module), AKMB (Wireless Gateway) |
| Instrument Type | Multi-Channel |
| IP Rating | AKMS-03: IP67 |
| AKMB-03D & AKMB | IP54 |
| Operating Frequency | 433 MHz |
| Temperature Range | AKMS-03 (Standard Battery): –20 °C to +60 °C |
| AKMS-03 (Low-Temp Battery) | –40 °C to +70 °C |
| AKMB-03D | –200 °C to +150 °C |
| Temperature Accuracy | AKMS-03: ±0.5 °C |
| AKMB-03D | ±(0.3 + 0.005t) °C |
| Temperature Resolution | 0.1 °C |
| Humidity Range | 0–99% RH |
| Humidity Accuracy | ±3% RH (typical, 20–80% RH) |
| Memory Capacity | AKMS-03: 4 Mbit (≈100,000 records) |
| AKMB | ≥100,000 records (expandable) |
| Battery | AKMS-03: 2 × CR2450 (non-rechargeable, 2–5 yr life) |
| AKMB-03D & AKMB | 2 × 18650 Li-ion (rechargeable) |
| Communication | interBow® proprietary LPWAN protocol (433 MHz), GPRS/2G (mobile & Unicom networks) |
| Transmission Distance | ≥650 m (line-of-sight) |
| Data Security | End-to-end encrypted transmission |
| Brand | BCC |
|---|---|
| Origin | Hebei, China |
| Model | KSD-1000 |
| Instrument Type | Relative Humidity (RH) Sensor |
| Measurement Range | 0–100% RH |
| Accuracy | ±1.5% RH |
| Resolution | 1% RH |
| Operating Ambient Temperature | −20 to +50 °C |
| Power Supply | 220 VAC, 50 Hz |
| Sensing Principle | Polymer Thin-Film Capacitive |
| Output Signal | 4–20 mA DC |
| Enclosure Rating | IP65 (Dust-Resistant & Corrosion-Resistant) |
| Brand | Campbell Scientific |
|---|---|
| Model | TM320 |
| Origin | USA |
| Temperature Range | −20 to 70 °C |
| Temperature Accuracy | ±0.5 °C |
| Relative Humidity Range | 0 to 95 %RH (non-condensing) |
| RH Accuracy | ±2 %RH |
| Operating Environment | −20 to 70 °C |
| Power Supply | 4 × AA alkaline batteries or optional AC adapter |
| Memory Capacity | 32,000 data points |
| Sampling Interval | Adjustable from 1 second to 24 hours (in 10-second increments) |
| Alarm Function | User-configurable high/low limits with audible alert |
| Housing Material | Polycarbonate |
| Dimensions | 10.2 × 7.7 × 3.9 cm |
| Weight | 255 g (9 oz) |
| Certifications | CE |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | C1-AGP-10 |
| Instrument Type | Multi-Channel |
| External Dimensions | 8.8 × 2.6 × 6.8 cm |
| Temperature Range | −196 °C to +100 °C |
| Temperature Accuracy | ±0.5 °C |
| Sampling Interval | 1–10 minutes per reading |
| Sensor Interface | 1 x External Temperature & Humidity Probe (RS485/Modbus or analog optional) |
| Communication | Embedded LTE-M/NB-IoT or Wi-Fi (configurable) |
| Display | Integrated OLED screen for real-time local readout |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Model | C1-AGS-10(4G) |
| Dimensions | 8.8 × 2.6 × 6.8 cm |
| Temperature Range | −40 °C to +100 °C |
| Temp. Accuracy | ±0.5 °C |
| Humidity Range | 0–100 %RH |
| RH Accuracy | ±2 %RH |
| Logging Interval | 1–10 min |
| Channel Count | Multi-Channel (1 external温湿度 sensor input) |
| Connectivity | Embedded 4G LTE module for cloud transmission |