Temperature & Humidity Detector
Filter
Showing 151–180 of 351 results
| Brand | NK |
|---|---|
| Origin | USA |
| Model | DROP D2 |
| Channel Count | Multi-Channel |
| IP Rating | IP67 (30-min submersion) |
| Drop Resistance | MIL-STD-810G (1 m drop) |
| Operating Range | –10°C to +55°C (14°F to 131°F) |
| Temp Accuracy | ±0.5°C (±0.9°F) |
| Sensor Type | External-sealed thermistor & humidity sensor with thermal isolation |
| Battery | CR2032 lithium coin cell (up to 4 months typical life) |
| Memory Capacity | >7,000 combined temperature/humidity data points |
| Wireless Protocol | Bluetooth® 4.0 (BLE) |
| Max Bluetooth Range | 100 ft (30 m, line-of-sight) |
| Dimensions | 24 × 46 × 60 mm (1 × 1.8 × 2.4 in) |
| Weight | 34 g (1.2 oz) |
| App Compatibility | Kestrel LiNK for iOS 6+ (iPhone 4s or newer, iPad 3rd gen+, iPod Touch 5th gen+) and Android 4.3+ with Bluetooth Smart® support |
| Brand | NK |
|---|---|
| Origin | USA |
| Model | DROP D2AG |
| Channel Count | Multi-channel |
| IP Rating | IP67 (30-min submersion) |
| Drop Resistance | MIL-STD-810G (1 m drop) |
| Operating Range | –10°C to 55°C (14°F to 131°F) |
| Temperature Accuracy | ±0.5°C (±0.9°F) |
| Humidity Sensing | Capacitive Polymer Sensor |
| Battery | CR2032 Lithium Coin Cell (up to 4 months typical life) |
| Memory Capacity | >7,000 temperature/humidity data points |
| Wireless Protocol | Bluetooth® 4.0 Low Energy (BLE) |
| Max Wireless Range | 30 m (100 ft) line-of-sight |
| Dimensions | 24 × 46 × 60 mm |
| Weight | 34 g |
| Calculated Indices | Heat Stress Index (HSI), Dew Point Temperature, Temperature-Humidity Index (THI) |
| Compliance | RoHS, FCC Part 15, IC RSS-247 |
| Brand | NK |
|---|---|
| Origin | USA |
| Model | DROP D2HS |
| Temperature Range | -10 to 55°C |
| Temperature Accuracy | ±0.5°C |
| Resolution | 0.1°C |
| Operating Environment | -18°C to 60°C |
| Power Supply | User-replaceable CR2032 coin cell |
| Dimensions | 6 × 4.5 × 2.3 cm |
| Weight | 34 g |
| IP Rating | IP67 (30-min submersion) |
| Shock Resistance | MIL-STD-810G (1 m drop) |
| Data Capacity | >7,000 temperature/humidity records |
| Battery Life | Up to 4 months (typical use) |
| Wireless Range | Up to 30 m (100 ft) via Bluetooth® 4.0+ |
| Computation Capabilities | Heat Stress Index (HSI), Dew Point Temperature |
| Brand | NK |
|---|---|
| Origin | USA |
| Model | DROP D3 |
| Channel Count | Multi-channel |
| Dimensions | 6 × 4.5 × 2.3 cm |
| Mounting | Wall-mountable |
| IP Rating | IP67 |
| Weight | 34 g |
| Bluetooth Range | Up to 30 m (100 ft) line-of-sight |
| Logging Interval | Configurable from 2 sec to 12 hr |
| Battery Life | Up to 3 months (typical use, 1-min interval) |
| Memory Capacity | 16,384 data points per sensor |
| Operating Temperature | –20 °C to 60 °C |
| Relative Humidity Range | 0–100 % RH (non-condensing) |
| Pressure Range | 300–1100 hPa |
| Accuracy (Temp) | ±0.5 °C (–10 to 50 °C) |
| Accuracy (RH) | ±3 % RH (20–80 % RH) |
| Accuracy (Pressure) | ±1.5 hPa |
| Brand | NK |
|---|---|
| Origin | USA |
| Model | DROP D3FW |
| Channel Count | Multi-channel |
| Dimensions | 60 × 46 × 24 mm (2.36 × 1.81 × 0.94 in) |
| Mounting | Wall-mountable with integrated D-ring |
| Enclosure Material | Engineering-grade ABS plastic |
| Ingress Protection | IP67 |
| Shock Resistance | MIL-STD-810G compliant |
| Weight | 34 g (1.2 oz) |
| Wireless Range | Up to 30 m (100 ft) line-of-sight via Bluetooth® 4.0+ |
| Logging Interval | Configurable from 2 seconds to 12 hours |
| Memory Capacity | Up to 13,000 data points per parameter |
| Battery Life | Up to 3 months (typical use, 1-min interval) |
| Operating Temperature | –20 °C to 60 °C (–4 °F to 140 °F) |
| Relative Humidity Range | 5–95 %RH (non-condensing) |
| Pressure Range | 300–1100 hPa (mbar) |
| Accuracy (Temp) | ±0.5 °C (±0.9 °F) @ 25 °C |
| Accuracy (RH) | ±3 %RH @ 20–80 %RH |
| Accuracy (Pressure) | ±1.5 hPa |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 240 |
| Channel Options | 2-channel (240-2P) or 8-channel (240-8P) |
| Temperature Range | 1 K to 800 K |
| Sensor Compatibility | Cernox®, Platinum RTDs, DT-670/DT-470 Diodes, Germanium, Carbon-Glass, RhFe, Rox™, GaAlAs |
| Excitation | 4-wire differential, constant current (10 µA) with polarity reversal |
| Isolation | Opto-isolated sensor inputs (channel-to-ground), non-isolated channel-to-channel |
| Communication | PROFIBUS-DP v1, USB 2.0 |
| Display | 128×32-pixel OLED, dual-parameter real-time readout (K/°C/°F/V/Ω), update rate: 2 Hz |
| Calibration | User-loadable 200-point curves per channel |
| Mounting | DIN-rail compatible, rear busbar for shared power & fieldbus |
| Compliance | CE, RoHS, PROFIBUS Nutzerorganisation (PNO) certified |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model Series | DT-670, Cernox® CX-1050/CX-1070, Rox™ RX-102B-RS/RX-102A, DT-621-HR, GR-100, CT-400, TC-E/K, Pt-100/200 |
| Temperature Range | 0.005 K to 1543 K (model-dependent) |
| Calibration | NIST-traceable, standard curves per IEC 60751 (Pt), ASTM E1137 (RTD), MIL-STD-883 (radiation) |
| Vacuum Compatibility | Up to 1×10⁻¹⁰ Pa (ultra-high vacuum) |
| Magnetic Field Tolerance | < ±0.1% reading up to 20 T (Cernox®, Rox™) |
| Radiation Hardness | Qualified to 1×10⁸ rad(Si) (Cernox®, GR-100, HR series) |
| Interchangeability | DT-670, Rox™, and Pt-series sensors comply with standardized resistance-vs-temperature curves (e.g., DT-670 curve, Rox™ Curve #1, Pt-100 DIN 43760) |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 211 |
| Temperature Range | 1.4 K to 800 K |
| Input Channels | 1 |
| Sensor Types Supported | Silicon Diode, GaAlAs Diode, 100 Ω Pt, 1000 Ω Pt, Carbon-Glass, Cernox®, Rox™ |
| A/D Resolution | 24-bit |
| Measurement Update Rate | 7 Hz |
| Display Resolution | 0.001 K (0–99.999 K), 0.01 K (100–999.99 K), 0.1 K (>1000 K) |
| Display | 5-digit LED |
| Output Options | 0–10 V, 4–20 mA, Relay, RS-232/RS-485 Serial Interface |
| User Calibration Curves | 1 × 200-point non-volatile memory |
| Excitation Method | Constant-current, 4-wire differential |
| Isolation | Not chassis-ground isolated |
| Compliance | Designed for cryogenic vacuum and magnetic field environments |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 218 |
| Input Channels | 8 |
| Sensor Compatibility | Diode (Si, GaAlAs) and Resistance (Pt100, Pt1000, Germanium, Carbon-Glass, Cernox®, Rox™) |
| Temperature Range | 1.2 K to 375 K |
| Resolution | 0.001 K (0–99.999 K), 0.01 K (100–999.99 K), 0.1 K (>1000 K) |
| Update Rate | 16 readings/s total (2 full scans of all 8 channels per second) |
| Calibration Curves | 8 × 200-point user-definable curves |
| SoftCal™ Support | DT-470 diode (30–375 K, ±0.25 K improvement), Pt resistance (70–325 K, ±0.25 K improvement) |
| Interfaces | IEEE-488 (GPIB), RS-232C, dual analog voltage outputs, 8 relay outputs |
| Display | 4-line × 20-character backlit LCD |
| Excitation | 8 independent constant-current sources, 4-wire differential measurement |
| Brand | Lake Shore |
|---|---|
| Origin | USA |
| Model | 224 |
| Sensor Channels | 12 (2 dedicated, 10 multiplexed) |
| Operating Range | 300 mK to 375 K |
| Input Types | Cernox®, silicon diodes (e.g., DT-670), Pt RTDs (100 Ω / 1000 Ω), Rox™, germanium, carbon-glass |
| A/D Resolution | 24-bit |
| Update Rate | up to 10 readings/s (dedicated channels), 1–2 readings/s (scanned channels) |
| Isolation | optical isolation between sensor inputs and system ground |
| Calibration Storage | 39 user-defined 200-point curves |
| Display | 240 × 64 pixel LCD (8 × 40 characters), LED backlit |
| Interface | front-panel 6-pin DIN connectors |
| Compliance | designed for GLP/GMP-aligned lab environments |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Model | P1200B |
| Temperature Range | 150–1150 °C |
| Cavity Diameter | 50 mm |
| Cavity Depth | 400 mm |
| Emissivity | 0.998 |
| Temperature Stability | ±0.2 °C over 60 min |
| Temperature Uniformity | < ±0.15% t across central 40 mm of 50 mm cavity |
| Heating Rate | ~2 h to reach 1000 °C |
| Controller | Eurotherm PID with N-type Thermocouple |
| Power Supply | 220–240 V, 50–60 Hz |
| Brand | LAND |
|---|---|
| Origin | United Kingdom |
| Model | P1600B2 |
| Temperature Range | 500–1550 °C |
| Emissivity | 0.998 |
| Stability | ±0.2 °C per 60 min |
| Uniformity | < ±0.15% of setpoint over central 40 mm of 50 mm-diameter cavity |
| Cavity Dimensions | Ø50 mm × 400 mm |
| Temperature Resolution | 1 °C |
| Heating Time | 90 min to 1400 °C |
| Cooling Time | 180 min to 200 °C |
| Ambient Operating Conditions | 10–40 °C |
| Controller | Eurotherm PID with Type R Thermocouple |
| Power Supply | 220–240 V, 50–60 Hz |
| Origin | UK |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | EL-USB-2-LCD |
| Pricing | Available Upon Request |
| Temperature Range | −35 °C to +80 °C |
| Humidity Range | 0–100 %RH |
| Temperature Accuracy | ±0.5 °C |
| Humidity Accuracy | ±3 %RH (20–80 %RH), ±5 %RH (outside) |
| Memory Capacity | 16,379 readings |
| Battery Life | Up to 1 year (typical at 25 °C, 2-min logging interval) |
| Display | Integrated LCD (shows real-time temp/RH, min/max, status) |
| Interface | USB-A plug-and-play for data download and configuration |
| Logging Interval | Configurable from 1 second to 12 hours |
| Operating Environment | Indoor, non-condensing environments |
| Brand | LaVision GmbH |
|---|---|
| Origin | Germany |
| Model | ICOS-Temperature |
| Application Domain | In-cylinder combustion diagnostics |
| Measurement Principle | Tunable Diode Laser Absorption Spectroscopy (TDLAS) in the near-infrared (NIR) range |
| Output Resolution | Crank-angle-resolved (≤0.1° CA), single-cycle or multi-cycle averaged |
| Probe Options | Non-intrusive fiber-coupled optics or minimally intrusive sapphire-windowed probes |
| Compliance | Designed for integration into ISO 2534, SAE J1939, and EU Regulation (EC) No 715/2007 test environments |
| Data Interface | Ethernet (TCP/IP), synchronized with engine position encoder (e.g., AVL PUMA, ETAS INCA) |
| Brand | Linkam |
|---|---|
| Origin | United Kingdom |
| Model | FDCS196 |
| Temperature Range | –196 °C to +125 °C (with LN₂ cooling pump) |
| Heating Rate | Up to 150 °C/min |
| Temperature Stability | < 0.1 °C |
| Sensor | 100 Ω Platinum RTD |
| Vacuum Level | Down to 10⁻³ mbar |
| Sample Area | Ø22 mm |
| XY Manipulation Range | 15 mm |
| Window Thickness | 0.5 mm (single ultra-thin optical window) |
| Sample Volume | As low as 5 µL |
| Compatible With | Polarized light, phase contrast, confocal microscopy, Raman spectroscopy, FTIR, and X-ray imaging |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-108 |
| Instrument Type | Fixed-Mount Thermal Screening Gateway |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Thermal Resolution | ±0.3 °C |
| Measurement Range | 20 °C to 50 °C |
| Detection Distance | 1.5 m to 5 m |
| Throughput Capacity | 150–200 persons/min |
| Blackbody Emissivity | 0.96 ± 0.02 |
| NETD | ≤60 mK (F/1, 300 K, 50 Hz) |
| IR Sensor | Uncooled Microbolometer Array (160 × 120 pixels, 17 µm pitch, 8–14 µm spectral band) |
| Visible Camera | 2 MP CMOS, 6 mm lens, 0.01 Lux (color), SNR > 56 dB |
| Onboard Processing | Broadcom BCM2711 (64-bit quad-core @ 1.5 GHz), VideoCore VI GPU, dual-band Wi-Fi 802.11ac + Gigabit Ethernet |
| Power Input | 5 V/3 A via USB-C |
| Operating Temperature | 0 °C to 40 °C |
| Enclosure | Flame-retardant, waterproof PVC composite (IP54-rated indoor/outdoor use with optional rain canopy) |
| Passage Dimensions | 1900 (H) × 700 (W) × 580 (D) mm |
| Brand | Mechanical Devices |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | Max TC |
| Measurement Method | Contact-Based |
| Temperature Range | -60°C to +175°C |
| Cooling Power | 52 W @ -40°C, ~200 W @ 0°C |
| Thermal Ramp Performance | 25°C → -40°C in < 2 min |
| Temperature Stability | ±0.1°C at high-temperature setpoints |
| Power Supply | Standard AC outlet (100–240 VAC, 50/60 Hz) |
| Environmental Compliance | Compressor-free operation, frost-free control, no compressed air or cryogenic fluids required |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | INE700 |
| Pricing | Upon Request |
| Brand | METER |
|---|---|
| Origin | Germany |
| Model | TEROS 06 |
| Temperature Range | –20 to 50 °C |
| Accuracy | ±0.1 °C (0–30 °C), ±0.2 °C (–20 to 50 °C) |
| Resolution | ±0.03 °C |
| Measurement Depths | –5, –10, –20, –30, –50, –100 cm |
| Output Interfaces | SDI-12, RS-485 (Modbus RTU / tensioLINK), DDI |
| Power Supply | 3.9–28.0 VDC |
| Operating Temperature | –30 to 60 °C |
| Probe Diameter | 20 mm |
| Length | 1040 mm |
| Housing Material | PA66GF30 |
| Sensing Element | Stainless Steel |
| Cable Standard | 4.5 m (custom up to 75 m) |
| Compliance | ISO 9001:2015, CE (EMC per ISO/IEC 17050:2010) |
| Sampling Resolution | 8-bit (EC600/EC650), 10-bit (EC700/EC750), 16-bit (EC800/EC850) |
|---|---|
| Temperature Range | –40 to +80 °C (EC700–EC850) |
| Relative Humidity Range | 5–95 %RH (EC700–EC850) |
| Temp Accuracy | ±0.2 °C (EC700–EC850), ±0.6 °C (EC600/EC650) |
| RH Accuracy | ±2 %RH (EC700–EC850), ±3 %RH (EC650) |
| Temp Resolution | 0.04–0.2 °C |
| RH Resolution | 0.1 %RH |
| Memory Capacity | 16,000–52,000 samples (multi-channel) |
| Sampling Interval | 10 s to 2 h (EC600–EC750) |
| Display | 2-digit 7-segment LCD (EC600/EC650) |
| Communication | RS-232 (EC600–EC750), Mini USB (EC800/EC850) |
| Power | ½ AA or ⅔ AA 3.6 V lithium battery |
| Battery Life | ~1.5–2 years (sampling-dependent) |
| Enclosure Rating | IP54 or IP65 |
| Compliance | CE, RoHS |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Model | HWSK-6 |
| Channel Count | Single-channel |
| Display | Backlit LCD with Chinese UI |
| Input Sensor | Type K thermocouple |
| Temperature Range | Ambient to 1000 °C |
| Resolution | 0.1 °C |
| Temperature Accuracy | ±3 °C |
| Time Programmability | 000–999 min (1-min resolution) |
| Control Algorithm | PID |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Max Load Power | ≤5 kW |
| Enclosure Material | Cast iron |
| Dimensions | 330 × 290 × 120 mm (L×W×H) |
| Mounting | Benchtop fixed installation |
| Weight | ~6 kg |
| Operating Environment | 0–40 °C, RH ≤80% |
| Cold-junction Compensation | Integrated constant-current circuit |
| Programmable Ramp Profiles | Up to 15 segmented temperature/time steps |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SWK-B |
| Channel Count | Single-Channel |
| Dimensions (L×W×H) | 330 × 290 × 120 mm |
| Mounting | Fixed Benchtop Installation |
| Power Supply | AC 220 V ±10%, 50 Hz |
| Output Voltage Range | 0–220 V (continuously adjustable) |
| Maximum Load Capacity | 5 kW |
| Control Output | Bidirectional SCR (zero-crossing switching) |
| Control Algorithm | PID with auto-tuning capability |
| Display | LED digital temperature indicator |
| Compliance | Designed for laboratory-grade thermal process control in accordance with GB/T 19001 (ISO 9001) manufacturing practices |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | SWK-S |
| Channel Count | Single-Channel |
| Dimensions (L×W×H) | 330 × 290 × 120 mm |
| Mounting | Benchtop Fixed Installation |
| Enclosure Material | Cast Iron |
| Input Voltage | 220 V AC, 50 Hz |
| Output Voltage Range | 0–220 V AC (Continuously Adjustable) |
| Maximum Load Capacity | 5 kW |
| Accuracy Class | 1.0 |
| Compatible Thermocouple | Type S (Platinum/Rhodium), 0–1600 °C |
| Operating Ambient Temperature | 0–40 °C |
| Control Algorithm | PID with Auto-Tuning Capability |
| Output Switching Device | Solid-State Relay (SSR), Contactless |
| Display | Dual-Digital LED (Setpoint & Process Value) |
| Brand | MingShen Science |
|---|---|
| Origin | Henan, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | WSWK-5 |
| Channel Count | Single-Channel |
| Dimensions (L×W×H) | 330 × 290 × 120 mm |
| Mounting | Benchtop Fixed Installation |
| Control Principle | PID Algorithm with Phase-Angle Triggered SCR Power Regulation |
| Temperature Range | Ambient to 1200 °C |
| Temperature Resolution | 1 °C |
| Sensor Input | Type K Thermocouple |
| Time Range | 0–999 minutes |
| Time Resolution | Auto-switching between 1 s, 10 s, and 1 min |
| Temp. Measurement Accuracy | ±3 °C |
| Timer Drift | <6 s per 24 h |
| Supply Voltage | 220 V ±10%, 50 Hz |
| Max. Load Power | 5 kW |
| Instrument Power Consumption | 10 W |
| Operating Environment | 0–40 °C, RH ≤80% |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MS+ |
| Price | Upon Request |
| Temperature Range | -32 to 530 °C |
| Optical Resolution | 20:1 |
| Spot Size at 20 | 1: ≥13 mm |
| Emissivity Adjustment | 0.100–1.000 (0.001 step) |
| Response Time | 300 ms |
| Accuracy | ±1% or ±1 °C (0–530 °C) |
| Display Features | Max/Min Hold, Backlit LCD, High/Low Temperature Alarm |
| Safety Certification | Ex ia II C T4 (Intrinsically Safe) |
| Power Supply | 9 V Alkaline Battery |
| Brand | MSR |
|---|---|
| Origin | Switzerland |
| Model Variants | MSR63, MSR64, MSR83, MSR84 |
| Sensor Type | Integrated temperature and/or relative humidity |
| Temperature Range | –30 °C to +70 °C |
| Relative Humidity Range (MSR64/MSR84) | 0–98 %RH (at –30 °C to +70 °C) |
| Temperature Accuracy | ±0.5 °C |
| RH Accuracy | ±3 %RH |
| Resolution | 0.1 °C |
| Logging Interval | 1 min |
| Storage Capacity | 16,000 points (MSR63/MSR83), 32,000 points total (16,000 temp + 16,000 RH for MSR64/MSR84) |
| Battery | 3.0 V lithium cell |
| Battery Life | ~12 months |
| Enclosure Rating | IP54 |
| Dimensions (MSR63/MSR64) | 39 × 8 × 58 mm, 18 g |
| Dimensions (MSR83/MSR84) | 43 × 10 × 80 mm, 30 g |
| Interface | USB 2.0 |
| Compliance | DIN 12830, FDA 21 CFR Part 11 |
| Calibration | Factory-provided 6-point certificate included |
| Brand | NPL (National Physical Laboratory) |
|---|---|
| Origin | United Kingdom |
| Instrument Category | Temperature Verification and Calibration System |
| Calibration Fixed Points | Fe–C (1153 °C), Co–C (1324 °C), Pd–C (1492 °C), Pt–C (1738 °C), Ru–C (1953 °C), Lr–C (2290 °C), Ag (961.8 °C), Cu (1084.6 °C) |
| Expanded Uncertainty (k = 2) | ±0.17 °C to ±1.6 °C depending on fixed point |
| Accreditation | UKAS ISO/IEC 17025 |
| Compliance | JJF (Military) 130–2017, ITS-90 extension protocols |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Mini-InfraPro4 |
| Price | Upon Request |
| Temperature Range (Mini-InfraPro4) | –18 °C to 400 °C |
| Temperature Range (Mini-InfraPro6) | –30 °C to 500 °C |
| Resolution | 0.1 °C/°F |
| Accuracy | ±3 °C (–18 to –1 °C), ±1 °C (10 to 30 °C), ±2% or ±2 °C (whichever is greater) for –1 to 400 °C |
| Response Time | 500 ms (95% response) |
| Emissivity | Fixed at 0.95 |
| Laser Targeting | Single-point, Class II |
| Distance-to-Spot Ratio | 8:1 (Mini-InfraPro4), 10:1 (Mini-InfraPro6) |
| Dimensions (L × W × H) | 10.2 × 15.2 × 4.0 cm |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Product Origin | Imported |
| Model | 91426-50 |
| Pricing | Available Upon Request |
| Sensor Type | High-Accuracy Thermistor Probe |
| Temperature Range | –40 °C to +150 °C |
| Accuracy | ±0.03 °C (–40 to 99.99 °C), ±0.1 °C (100 to 125 °C), ±0.5 °C (125 to 150 °C) |
| Resolution | 0.01 °C (–40 to 99.99 °C), 0.1 °C (100 to 150 °C) |
| Display | Backlit LED, Dual-Unit (°C/°F), Min/Max/Hold |
| Data Logging | 2000-point internal memory |
| Interface | USB 2.0 |
| Sampling Interval | 1 s to 60 min |
| Enclosure Rating | IP54 |
| Dimensions (L×W×H) | 10.2 × 17.8 × 5.1 cm |
| Power | 4 × AA batteries (included), Auto-off, Low-battery indicator |
| Calibration | Internal auto-calibration routine |
| Standard Accessories | Protective carrying case (probe not included) |
| Brand | Pixsys |
|---|---|
| Origin | Italy |
| Model | ATR224 |
| Input Types | Thermocouples (K, S, R, J, T, N, B), RTDs (PT100/500/1000, Ni100, PTC1K, NTC10K), 0–10 V, 0/4–20 mA, 0–60 mV, Potentiometer (1–150 kΩ) |
| Input Resolution | 16-bit |
| Sampling Time | Programmable down to 2.1 ms (up to 470 Hz) |
| Control Outputs | 2 x Relay (2 A / 250 V AC resistive), 1 x SSR (12/24 V DC / 25 mA), 1 x Auxiliary 12/24 V DC (30 mA max for sensor excitation) |
| Digital Input | 1 x PNP |
| Communication | microUSB (MyPixsysLab PC software), NFC/RFID (MyPixsys mobile app for Android/iOS) |
| Display | 48 × 48 mm front panel, IP65-rated polycarbonate (UL94V2), housing IP20 |
| Power Supply | 24–230 V AC/DC ±15%, 50/60 Hz, 2.5 kV galvanic isolation |
| Power Consumption | 8 VA |
| Operating Environment | 0–45 °C, 35–95 % RH (non-condensing), max. 2000 m altitude |
| Dimensions | 48 × 48 × 105 mm (W×H×D) |
| Weight | ~185 g |
| Compliance | CE-marked, conforms to EN 61000-6-2 (immunity) and EN 61000-6-4 (emission), designed for industrial control environments per IEC 61000-4 series |