Temperature & Humidity Detector
Filter
Showing 31–60 of 164 results
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Model | C1-C0P-10 |
| Channel Count | Multi-Channel |
| Dimensions | 8.8 × 2.6 × 6.8 cm |
| Temperature Range | −196 °C to +100 °C |
| Accuracy | ±0.1 °C (−50 °C to +50 °C) |
| Sampling Interval | 1–10 min |
| Wireless Transmission Distance | 2300 m (line-of-sight) |
| Penetration Capability | Two-story reinforced concrete structure |
| Sensor Interface | Single external temperature sensor port |
| Brand | Duling |
|---|---|
| Origin | Anhui, China |
| Model | C2-AGS-11 |
| Instrument Type | Multi-Channel Data Logger |
| Temperature Range | -40°C to +65°C |
| Humidity Range | 0–99% RH |
| Temp. Accuracy | ±0.5°C |
| RH Accuracy | ±5% RH |
| Internal Sensor | SHT30 |
| External Probe Support | NTC |
| Logging Interval | 2 s – 24 h (adjustable) |
| Memory Capacity | ≥60,000 records |
| Display | 1.3″ OLED (128×64 px) |
| Power | 5000 mAh Li-Polymer battery |
| Connectivity | USB Mass Storage (offline), Virtual COM Port (online), Nano-SIM (China Mobile/Unicom), LBS-based positioning (≤300 m typical accuracy) |
| Brand | Ellab |
|---|---|
| Origin | Denmark |
| Model | TrackSense Pro Compact |
| Temperature Range | –90 °C to +140 °C |
| Channel Type | Multi-Channel |
| Sensor Integration | Integrated Pt1000 RTD |
| Battery Life | Up to 30 days (typical, dependent on logging interval) |
| Pressure Measurement | Optional integrated pressure sensor |
| Compliance | FDA 21 CFR Part 11, ISO 13485, EU GMP Annex 15, ASTM E2810, USP <1059> |
| Brand | Beijing BoLun JingWei Tech Dev Co., Ltd. |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | MIJ-NLTP |
| Price | USD 1.00 (Reference Only) |
| Measurement Range | -30 °C to 1100 °C |
|---|---|
| Accuracy | ±0.5 °C |
| Resolution | 1 °C |
| Repeatability | ±1 °C |
| Spectral Band | 8–14 µm |
| Optical Field of View | Standard 2° or 15°, optional 60° |
| Emissivity Adjustment | 0.2–0.98 (user-selectable via rear panel) |
| Response Time | 0.1 s |
| Operating Ambient Temperature | -10 °C to 50 °C, ≤99% RH (non-condensing) |
| Storage Temperature | -10 °C to 50 °C |
| Lens Material | Dual-coated zinc selenide (ZnSe), MIL-C-13508 compliant |
| Output Signal | RS-232C standard, optional 1 mV/°C analog output |
| Power Supply | Rechargeable NiCd battery, 40 h continuous operation |
| Battery Charger | 120 V/60 Hz/3 W or 230 V/50 Hz optional |
| Minimum Measurement Distance | 2 cm |
| Maximum Measurement Distance | 300 m |
| Housing | Stainless steel |
| Origin | Imported |
| Manufacturer Type | Distributor |
| Origin | Imported |
|---|---|
| Manufacturer Type | Distributor |
| Model | HBW Series |
| Pricing | Upon Request |
| Accuracy Class | A (±0.1 °C), B (±0.2 °C to ±0.3 °C) |
| Measurement Range | HBW-1: −50 °C to +50 °C |
| HBW-2 | −50 °C to +80 °C |
| Sensor Element | IEC 60751-compliant Pt100 (α = 0.00385 Ω/Ω/°C) |
| Configuration | 4-wire RTD |
| Cable | Shielded 4-core, standard 10 m (custom lengths available) |
| Probe Dimensions | 70 mm sheath length, 4 mm sensing tip diameter, 10 mm sheath OD |
| Mass | 0.35 kg (including 10 m cable) |
| Calibration Interval | 2 years |
| Compliance | IEC 60751:2022, EN 60751, ASTM E1137/E1137M |
| Brand | HORIBA |
|---|---|
| Origin | Japan |
| Model | IT-230 |
| Temperature Range | 0–300 °C |
| Output | Analog (4–20 mA or 0–10 V selectable) |
| Alarm Outputs | Dual independent relay outputs |
| Mounting | Benchtop / Fixed-installation compatible |
| Compliance | CE marked, RoHS compliant |
| Enclosure Rating | IP65 (front panel) |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 993, 996 |
| Instrument Type | Blackbody Calibrator |
| Temperature Range | −10 °C to 550 °C |
| Stability | ≤ 0.1 °C |
| Temperature Resolution | 0.01 °C |
| Warm-up Time | 40 min (from ambient to 80 °C) |
| Cool-down Time | 45 min (from ambient to −10 °C) |
| Operating Ambient Temperature | −29 °C to 50 °C |
| Cavity Aperture | 50 mm (Model 993), 65 mm (Model 996) |
| Emissivity | > 0.995 |
| Temperature Uniformity | ≤ ±0.15 °C or ±0.15% of reading (whichever is greater) |
| Enclosure Rating | IP56 |
| Interface | RS-232 |
| Internal Cavity Dimensions | 355 mm × 279 mm × 406 mm |
| External Dimensions (D×W×H) | 355 mm × 279 mm × 406 mm |
| Mass | 18.1 kg |
| Compliance | MIL-PRF-28800F, BS EN 60068-2-1:2007, BS EN 60068-2-14:2009, ISO 3744:2010 |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Product Type | Portable Dry-Block Temperature Calibration System |
| Primary Components | Millik Precision Thermometer + ISOTECH Dry-Block Furnace (Model B) |
| Temperature Range | −45 °C to 1200 °C |
| Measurement Channels | 3 independent inputs (simultaneous differential measurement supported) |
| Input Types | Thermocouples (all standard types), RTDs (Pt100, Pt1000), Thermistors (2-wire/3-wire/4-wire), and 4–20 mA current loops |
| Internal Reference | Built-in ITS-90 temperature conversion algorithms |
| Compliance | Designed for traceable calibration per ISO/IEC 17025, ASTM E2877, and IEC 60584 |
| Software Interface | USB and RS232 connectivity with optional ISOTECH CalSoft™ for automated calibration reporting and audit trails |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 414 |
| Maximum Operating Temperature | 1000 °C |
| Control System | Integrated Programmable Temperature Controller |
| Application | Annealing, Heat Treatment and Stabilization of Platinum Resistance Thermometers (PRTs) |
| Compliance | Designed for use in calibration laboratories adhering to ISO/IEC 17025, ASTM E1137/E2877, and IEC 60751 |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | 471 |
| Temperature Fixed Point | Argon Triple Point (−189.3442 °C) |
| Uncertainty (k=2) | 1.844 mK |
| Plateau Duration | ≥4 h |
| Accuracy | ±1 mK |
| Dimensions (H×W×D) | 1250 × 380 × 615 mm (Apparatus Height: 900 mm) |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | POTS-SLIM |
| Type | Portable Dry-Block Fixed-Point Preservation Furnace |
| Heating Configuration | Triple-zone (main + upper/lower auxiliary heaters) |
| Vertical Temperature Uniformity | ±0.1 °C over fixed-point cell height |
| Operating Modes | Freezing Curve & Melting Curve Execution |
| Compliance | Designed for ITS-90 fixed-point realization and calibration traceability |
| Brand | ISOTECH |
|---|---|
| Origin | United Kingdom |
| Model | TTI-22 |
| Temperature Range | −250 °C to 960 °C |
| Measurement Uncertainty | ≤1 mK (0.001 °C) |
| Resolution | 0.0001 °C |
| Operating Ambient Temperature | 10 °C to 30 °C |
| Power Supply | 1 × AC mains input (100–240 V, 50/60 Hz) |
| Dimensions (W×H×D) | 190 mm × 112 mm × 240 mm |
| Weight | 1.8 kg |
| Sensor Compatibility | Pt25.5, Pt100 (industrial & standard), 4-wire configuration |
| Calibration Storage Capacity | Up to 30 sensor-specific calibration tables |
| Interface | RS232 serial port, Ethernet (TCP/IP), embedded web server |
| Compliance | ITS-90 (for SPRTs), DIN EN 60751 (for industrial Pt100), GLP/GMP-ready data logging with timestamped audit trail |
| Brand | JOFRA |
|---|---|
| Origin | Denmark |
| Model | ASC-400 |
| Type | Multifunction Process Calibrator |
| Input/Output Capabilities | RTD, Thermocouple, mA, V, Ω, Hz, Pulse Train |
| Pressure Calibration Support | Compatible with APM CPF Pressure Modules (Gauge & Absolute) |
| Temperature Calibration Support | Compatible with Dry-Block Calibrators |
| Display | Full-color LCD |
| Interface | True-Ohm RTD Measurement, Dual-Window Task Recall, Cursor + Function Keys |
| Protection | Fuseless Overload Protection |
| Compliance | Designed for Industrial Process Instrumentation Calibration |
| Brand | JOFRA |
|---|---|
| Origin | Denmark |
| Model | MTC Marine Dry-Block Calibrator |
| Temperature Range | 28 to 650°C |
| Stability | ±0.1°C |
| 1-Year Accuracy | ±0.9°C |
| 3-Year Accuracy | ±1.8°C |
| Power Supply Immunity | MVI (Microprocessor-Based Voltage Independence) Technology |
| Weight | Lightweight, Portable Design |
| Block Configuration | Multi-Hole Insert Kit Included |
| Application | In-Situ Calibration on Vessels and Offshore Platforms |
| Brand | KE-Technologe GmbH |
|---|---|
| Origin | Germany |
| Model | LP4 / LP5 |
| Temperature Range (LP4) | 650–3000 °C (Si detector) |
| Temperature Range (LP5) | up to 3400 °C (Si), up to 2500 °C (InGaAs) |
| Photocurrent Range | 1 pA – 8 nA |
| Accuracy Class | ±0.1% of reading |
| Spectral Bandpass | Interchangeable interference filters from 500 nm to 1600 nm (standard: 650 nm ±10 nm HBW) |
| Field of View | Target diameter 0.22 mm (LP5) / 0.25 mm (LP4) |
| Objective Lens | f = 143 mm, achromatic |
| Working Distance | 600 mm or 2000 mm (target-to-lens) |
| Expanded Uncertainty (k=2) | 0.8 K @ 1200 K, 1.2 K @ 1600 K, 2.1 K @ 2000 K, 3.4 K @ 2400 K, 4.8 K @ 2800 K |
| Long-Term Stability (6 months, 22 °C ±3 °C, k=1) | 0.25–2.4 K depending on temperature point |
| Power Supply | 115 V or 230 V, 50/60 Hz |
| Dimensions (H×W×D) | Host unit: 600×178×140 mm (LP4), 500×138×120 mm (LP5) |
| Power supply | 215×110×78 mm (LP4), 220×120×75 mm (LP5) |
| Weight | Host ~12 kg (LP4), ~9 kg (LP5) |
| Brand | KELLER HCW |
|---|---|
| Origin | Germany |
| Model | CellaCast |
| Type | Online Infrared Thermometer |
| Temperature Range | 650–1700 °C |
| Measurement Principle | Two-Color (Ratio) Infrared Radiometry |
| Optical Field of View | Rectangular |
| Special Features | Clean Surface Detection (CSD), Automatic Temperature Detection (ATD), Analog & Serial Data Output, Integrated Alarm Interface, IP65 Housing (with optional air purge & water cooling) |
| Brand | KELLER HCW |
|---|---|
| Origin | Germany |
| Type | Portable Optical Pyrometer |
| Model | PV11 |
| Temperature Range | 700–3500 °C |
| Minimum Spot Size | 0.1 mm |
| Distance-to-Spot Ratio | up to 5000:1 (e.g., Ø1 mm target at 5 m) |
| Measurement Principle | Visual Intensity Comparison (Two-Color Reference Filament Method) |
| Emissivity Sensitivity | Low |
| Display | Integrated Digital Readout |
| Brand | KELLER |
|---|---|
| Origin | Germany |
| Model | HCW Series |
| Measurement Principle | Two-Color (Ratio) and Single-Wavelength Pyrometry |
| Temperature Range | –30 °C to 3500 °C (model-dependent, segmented calibration) |
| Optical Resolution (Distance-to-Spot Ratio) | Up to 300:1 |
| Spectral Response | 0.8–1.1 µm (short-wave), 1.6 µm, 2.2 µm, or 8–14 µm (depending on model) |
| Output Signals | 4–20 mA, 0–10 V, thermocouple emulation, RS232/RS422/RS485 |
| Environmental Rating | IP65 (standard), optional IP67/IP69K housings |
| Housing Material | Anodized aluminum or AISI 316 stainless steel |
| Compliance | CE, RoHS, EMC Directive 2014/30/EU, IEC 61326-1 (industrial environments) |
| Brand | KELLER MSR |
|---|---|
| Origin | Germany |
| Type | Online Infrared Pyrometer |
| Model | PA Series |
| Optical Configurations | 4 Interchangeable Lenses |
| Target Spot Size | Down to 0.3 mm |
| Distance-to-Spot Ratio | Adjustable via Lens Selection |
| Analog Outputs | 2 (configurable as input/output) |
| Input/Output Flexibility | One analog channel可 configured as process input (e.g., furnace reference compensation) |
| Emissivity Compensation | Adjustable + Custom Correction Curve |
| Environmental Compensation | Transmission loss correction for protective windows, ambient radiation compensation |
| Targeting Options | Eyepiece viewfinder, Class 2 laser pointer, external video camera interface |
| Interface | USB, RS-485 (multi-drop network capable) |
| Display & Control | Integrated LED display + membrane keypad |
| Signal Processing | Adjustable smoothing, linearization, hold functions |
| Brand | Loobo |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | LB-108 |
| Instrument Type | Fixed-Mount Thermal Screening Gateway |
| Price Range | USD 1,400 – 7,000 (FOB) |
| Thermal Resolution | ±0.3 °C |
| Measurement Range | 20 °C to 50 °C |
| Detection Distance | 1.5 m to 5 m |
| Throughput Capacity | 150–200 persons/min |
| Blackbody Emissivity | 0.96 ± 0.02 |
| NETD | ≤60 mK (F/1, 300 K, 50 Hz) |
| IR Sensor | Uncooled Microbolometer Array (160 × 120 pixels, 17 µm pitch, 8–14 µm spectral band) |
| Visible Camera | 2 MP CMOS, 6 mm lens, 0.01 Lux (color), SNR > 56 dB |
| Onboard Processing | Broadcom BCM2711 (64-bit quad-core @ 1.5 GHz), VideoCore VI GPU, dual-band Wi-Fi 802.11ac + Gigabit Ethernet |
| Power Input | 5 V/3 A via USB-C |
| Operating Temperature | 0 °C to 40 °C |
| Enclosure | Flame-retardant, waterproof PVC composite (IP54-rated indoor/outdoor use with optional rain canopy) |
| Passage Dimensions | 1900 (H) × 700 (W) × 580 (D) mm |
| Origin | Germany |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Imported |
| Model | MS+ |
| Price | Upon Request |
| Temperature Range | -32 to 530 °C |
| Optical Resolution | 20:1 |
| Spot Size at 20 | 1: ≥13 mm |
| Emissivity Adjustment | 0.100–1.000 (0.001 step) |
| Response Time | 300 ms |
| Accuracy | ±1% or ±1 °C (0–530 °C) |
| Display Features | Max/Min Hold, Backlit LCD, High/Low Temperature Alarm |
| Safety Certification | Ex ia II C T4 (Intrinsically Safe) |
| Power Supply | 9 V Alkaline Battery |
| Brand | MSR |
|---|---|
| Origin | Switzerland |
| Model Variants | MSR63, MSR64, MSR83, MSR84 |
| Sensor Type | Integrated temperature and/or relative humidity |
| Temperature Range | –30 °C to +70 °C |
| Relative Humidity Range (MSR64/MSR84) | 0–98 %RH (at –30 °C to +70 °C) |
| Temperature Accuracy | ±0.5 °C |
| RH Accuracy | ±3 %RH |
| Resolution | 0.1 °C |
| Logging Interval | 1 min |
| Storage Capacity | 16,000 points (MSR63/MSR83), 32,000 points total (16,000 temp + 16,000 RH for MSR64/MSR84) |
| Battery | 3.0 V lithium cell |
| Battery Life | ~12 months |
| Enclosure Rating | IP54 |
| Dimensions (MSR63/MSR64) | 39 × 8 × 58 mm, 18 g |
| Dimensions (MSR83/MSR84) | 43 × 10 × 80 mm, 30 g |
| Interface | USB 2.0 |
| Compliance | DIN 12830, FDA 21 CFR Part 11 |
| Calibration | Factory-provided 6-point certificate included |
| Brand | Pixsys |
|---|---|
| Origin | Italy |
| Model | ATR224 |
| Input Types | Thermocouples (K, S, R, J, T, N, B), RTDs (PT100/500/1000, Ni100, PTC1K, NTC10K), 0–10 V, 0/4–20 mA, 0–60 mV, Potentiometer (1–150 kΩ) |
| Input Resolution | 16-bit |
| Sampling Time | Programmable down to 2.1 ms (up to 470 Hz) |
| Control Outputs | 2 x Relay (2 A / 250 V AC resistive), 1 x SSR (12/24 V DC / 25 mA), 1 x Auxiliary 12/24 V DC (30 mA max for sensor excitation) |
| Digital Input | 1 x PNP |
| Communication | microUSB (MyPixsysLab PC software), NFC/RFID (MyPixsys mobile app for Android/iOS) |
| Display | 48 × 48 mm front panel, IP65-rated polycarbonate (UL94V2), housing IP20 |
| Power Supply | 24–230 V AC/DC ±15%, 50/60 Hz, 2.5 kV galvanic isolation |
| Power Consumption | 8 VA |
| Operating Environment | 0–45 °C, 35–95 % RH (non-condensing), max. 2000 m altitude |
| Dimensions | 48 × 48 × 105 mm (W×H×D) |
| Weight | ~185 g |
| Compliance | CE-marked, conforms to EN 61000-6-2 (immunity) and EN 61000-6-4 (emission), designed for industrial control environments per IEC 61000-4 series |
| Brand | R.M. Young |
|---|---|
| Origin | USA |
| Model | 41342LC |
| Output Signal | 4–20 mA |
| Measurement Range | −50 to +50 °C |
| Accuracy (at 0 °C) | ±0.3 °C (±0.1 °C optional) |
| Time Constant | 42 s (with Model 43408 radiation shield) |
| Sensor Type | 1000 Ω Pt RTD (IEC 60751 Class B, standard |
| Enclosure | Weatherproof junction box |
| Calibration | Configurable for °C or °F output scaling |
| Recommended Radiation Shield | Model 43502 (aspirated) or Model 41003P (multi-plate passive) |
| Cable Recommendation | 2-pair shielded, 22 AWG (e.g., Part #18641) |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | RS-HW-N01 |
| Instrument Type | Fixed-mount |
| Power Supply | 10–30 V DC |
| Power Consumption | 0.4 W |
| Sensor Type | Dual-element pyroelectric infrared (PIR) sensor |
| Alarm Duration Options | 5 s / 10 s / 30 s (configurable) |
| Delay-on-Alarm | Software-configurable |
| Mounting Method | Ceiling-mounted |
| Installation Height | 2.5–6 m |
| Detection Range | Ø6 m (at 3.6 m mounting height) |
| Detection Pattern | Omnidirectional 360° horizontal coverage |
| Output Interface | RS-485 |
| Communication Protocol | Modbus-RTU |
| Operating Temperature | −10 °C to +50 °C |
| Operating Humidity | ≤95% RH (non-condensing) |
| RFI Immunity | 20–1000 MHz |
| Microcontroller | 8-bit low-power CMOS |
| Auto Temperature Compensation | Yes |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | Domestic (China) |
| Model | RS-WD-*-2 |
| Pricing | Upon Request |
| Power Supply | 10–30 V DC |
| Output Options | 4–20 mA / 0–5 V / 0–10 V |
| Default Accuracy | ±0.5 °C @ 25 °C |
| Operating Ambient Temp | −40 °C to +60 °C |
| Probe Temp Range | −40 °C to +120 °C (varies by probe type) |
| Humidity Range (probe) | 0–99 %RH |
| Long-Term Stability | ≤0.1 °C/year |
| Response Time | ≤10 s (at 1 m/s airflow) |
| Load Capacity | ≤600 Ω (current), ≤250 Ω (voltage) |
| Enclosure Type | IP65-rated wall-mounted “Wangzi” (character-style) housing |
| Mounting | Screw + anchor (included) |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM/ODM Manufacturer |
| Country of Origin | China |
| Model | RS-WS-DY |
| Communication | FHSS Radio (868 MHz ISM Band) |
| Display | 2.8" LCD with Real-Time Temp/RH/Time/Address/Storage Status |
| Power Supply | 10–30 V DC (AC/DC Adapter Included for 220 V AC Input) |
| Operating Temperature (Electronics) | −20 °C to +60 °C |
| Operating Humidity (Electronics) | 0–80 %RH |
| Sensor Operating Range (Standard Probe) | −40 °C to +80 °C, 0–99 %RH |
| Sensor Operating Range (Optional −B Wide-Temp Probe) | −40 °C to +120 °C |
| Accuracy (Class A) | ±0.4 °C @ 25 °C, ±2 %RH @ 25 °C (5–95 %RH) |
| Accuracy (Class B, Default) | ±0.5 °C @ 25 °C, ±3 %RH @ 25 °C (5–95 %RH) |
| Resolution | 0.1 °C / 0.1 %RH |
| Long-Term Drift | ≤0.1 °C/year, ≤1 %RH/year |
| Response Time (Standard Probe) | ≤25 s (Temp), ≤8 s (RH) at 1 m/s airflow |
| Response Time (−B Probe) | ≤18 s (Temp), ≤6 s (RH) at 1 m/s airflow |
| Data Storage Capacity | 65,535 records |
| Recording Interval | 1–65,535 minutes (configurable, default 30 min) |
| Storage Duration (at 30-min interval) | ~4 years |
| Storage Mode | Auto-cyclic overwrite |
| Alarm Outputs | 2 programmable relay outputs (NO/NC), 1 internal buzzer (85 dB), optional external sound-light alarm interface |
| Calibration | Password-protected on-device offset calibration for temperature and humidity |
| Compliance | FCC Part 15 Subpart C, CE RED Directive 2014/53/EU, RoHS 2011/65/EU |
| Wireless Protocol | Proprietary FHSS (Frequency-Hopping Spread Spectrum), 868 MHz, 100 kbps data rate |
| Line-of-Sight Range | ≥800 m |
| Wall Penetration | 3–4 reinforced concrete walls |
| Max Nodes per RS-JSQ-W Gateway | 200 units |
| Enclosure Rating | IP65 (housing), IP67 (optional −B and −6 waterproof probe variants) |
| Brand | RenKe |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | Manufacturer |
| Country of Origin | China |
| Model | RS-YS-GPRS-Y-LY |
| Price | USD 105 (approx.) |
| Brand | RM Young |
|---|---|
| Origin | USA |
| Model | 41342 |
| Sensor Type | 1000 Ω Pt RTD (Class A) |
| Output Options | 4-wire Pt RTD / 0–1 VDC (5 mA, 8–24 VDC supply) / 4–20 mA (20 mA, 12–30 VDC supply) |
| Temperature Range | –50 to +50 °C |
| Calibration Accuracy at 0 °C | ±0.3 °C (NIST-traceable certificate included) |
| Optional Enhanced Accuracy | ±0.1 °C |
| Recommended Radiation Shields | Gill 41003P Passive Multi-Plate Shield or 43502 Active Ventilated Shield |
| Compliance | NIST-traceable calibration, ISO/IEC 17025-compliant calibration procedures |