Temperature & Humidity Detector
Filter
Showing 121–150 of 164 results
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9055 |
| Temperature Measurement Principle | K-Type Thermocouple |
| Measurement Method | Contact |
| Temperature Range | −50 to +350 °C (short-term up to +500 °C) |
| Resolution | 0.1 °C |
| Accuracy | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Stability | ±1 °C (−50 to +99.9 °C), ±1 % of reading (remaining range) |
| Response Time t₉₉ | 10 s (in water) |
| Weight | 80 g |
| Dimensions (L×W×H) | 270 × 40 × 70 mm |
| Operating Temperature | 0 to +40 °C |
| Storage Temperature | −20 to +70 °C |
| Probe Sheath Length | 200 mm |
| Probe Tip Length | 4 mm |
| Probe Rod Diameter | 3 mm |
| Display | Single-line LCD |
| Housing Material | ABS |
| Power Supply | 3 × AAA batteries |
| Battery Life | Up to 1000 h |
| CE Marking | 2014/30/EU |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9056 |
| Temperature Measurement Principle | K-type Thermocouple |
| Measurement Method | Contact |
| Temperature Range | -50 to +350 °C (short-term up to +500 °C) |
| Resolution | 0.1 °C |
| Accuracy | ±(1 °C ±1 % of reading) |
| Stability | ±(1 °C ±1 % of reading) |
| Response Time (t₉₉) | 5 s |
| Weight | 80 g |
| Dimensions (L×W×H) | 220 × 40 × 70 mm |
| Operating Temperature | 0 to +40 °C |
| Storage Temperature | -20 to +70 °C |
| Probe Sheath Length | 150 mm |
| Probe Tip Length | 40 mm |
| Probe Stem Diameter | 3 mm |
| Probe Head Diameter | 12 mm |
| Display | Single-line LCD |
| Battery | 3 × AAA (rechargeable) |
| Battery Life | ~1000 h |
| Auto Power-off | After 10 min idle |
| Housing Material | ABS |
| Color | Black |
| Compliance | CE 2004/108/EC |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9221 |
| Temperature Measurement Principle | Thermocouple (Type K) |
| Measurement Method | Contact |
| Temperature Range | -50 to +1000 °C |
| Resolution | 0.1 °C (-50 to +199.9 °C), 1 °C (remaining range) |
| Accuracy | ±(0.5 °C + 0.3 % of reading) (-40 to +900 °C), ±(0.7 °C + 0.5 % of reading) (remaining range) |
| Stability | Same as accuracy specification |
| Operating Environment | -20 to +50 °C |
| Weight | 171 g |
| Dimensions | 182 × 64 × 40 mm |
| Power Supply | 9 V battery |
| Battery Life | 200 h (probe connected, backlight off), 68 h (probe connected, backlight on) |
| IP Rating | IP65 |
| Housing Material | ABS |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9255 |
| Temperature Measurement Principle | Thermocouple (Type K) |
| Measurement Method | Contact |
| Temperature Range | -50 to +1000 °C |
| Resolution | 0.1 °C (-50 to +199.9 °C), 1 °C (remaining range) |
| Accuracy | ±(0.5 °C + 0.3 % of reading) (-40 to +900 °C), ±(0.7 °C + 0.5 % of reading) (remaining range) |
| Stability | Identical to accuracy specification |
| Operating Environment | -20 to +50 °C |
| Dimensions | 182 × 65 × 40 mm |
| Weight | 171 g |
| Power Supply | 9 V battery |
| Battery Life | 200 h (backlight off, probe connected), 68 h (backlight on, probe connected) |
| Housing Material | ABS |
| Protection Rating (with optional protective sleeve) | IP65 |
| Channel Count | 1-channel |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9261 |
| Temperature Measurement Principle | Thermocouple (Type T, Type K compatible) |
| Measurement Method | Contact |
| Temperature Range | -50 to +400 °C |
| Resolution | 0.1 °C (-50 to +199.9 °C), 1 °C (remaining range) |
| Accuracy | ±0.3 °C (-20 to +70 °C) |
| Stability | ±0.3 °C (-20 to +70 °C) |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| IP Rating | IP65 (with optional protective sleeve) |
| Dimensions | 177 × 64 × 40 mm |
| Weight | 182 g (incl. 9 V battery) |
| Battery Life | 200 h (backlight off), 68 h (backlight on) |
| Compliance | EN 13485, HACCP principles, FDA-relevant food safety practices |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0560 9261 |
| Temperature Measurement Principle | Thermocouple (Type T & K) |
| Measurement Method | Contact |
| Temperature Range | -50 to +400 °C |
| Resolution | 0.1 °C (-50 to +199.9 °C), 1 °C (remaining range) |
| Accuracy | ±0.3 °C (-20 to +70 °C) |
| Stability | ±0.3 °C (-20 to +70 °C) |
| Operating Temperature | -20 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| IP Rating | IP65 (with optional protective sleeve) |
| Dimensions | 177 × 64 × 40 mm |
| Weight | 182 g (incl. 9 V battery) |
| Battery Life | 200 h (backlight off), 68 h (backlight on) |
| Compliance | EN 13485, HACCP-ready |
| Data Logging | Max/Min auto-capture, user-defined alarm thresholds with audible alert |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 0572 2166 |
| Input Interface | 4–20 mA / 0–10 V analog signals |
| Output Interface | Digital communication via TUC bus to testo 150 TUC4 Data Logger |
| Channel Capacity | Multi-channel (up to 8 analog inputs per coupler) |
| Compliance | Designed for GxP environments, supports audit trail-ready data acquisition per FDA 21 CFR Part 11 and EU Annex 11 requirements |
| Integration | Native component of testo Saveris Pharma platform |
| Communication | WLAN, LAN, or UltraRange radio-enabled via connected testo 150 TUC4 unit |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2034 |
| Channel Count | Single-channel |
| Temperature Range | −30 to +50 °C |
| Temp. Accuracy | ±0.5 °C |
| Temp. Resolution | 0.1 °C |
| RH Range | 0 to 100 %RH |
| RH Accuracy | ±2 %RH |
| RH Resolution | 0.1 %RH |
| Memory Capacity | 2 × 10,000 measurements |
| IP Rating | IP30 |
| Dimensions | 115 × 82 × 31 mm |
| Weight | 250 g |
| Power Supply | 4 × AA batteries (typical battery life: 24 months at +25 °C, 15-min interval) |
| Wireless Protocol | Wi-Fi (MQTT), supports WEP/WPA/WPA2/WPA2 Enterprise encryption |
| Time Sync | SNTP-capable |
| Operating Temperature | −30 to +50 °C |
| Storage Temperature (no battery) | −40 to +70 °C |
| Cloud Communication Interval | Basic license: fixed 15 min |
| Advanced license | adjustable from 1 min to 24 h |
| Measurement Interval | Basic: fixed 15 min |
| Advanced | adjustable from 1 min to 24 h |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2035 |
| Channel Count | Multi-channel |
| Measurement Range (Internal) | -30 to +50 °C, 0 to 100 %RH |
| Display | Integrated LCD |
| External Probe Interface | 1 x Pt1000 / capacitive humidity sensor (optional) |
| Memory Capacity | 2 × 10,000 readings |
| IP Rating | IP54 |
| Power Supply | 4 × AA batteries (typ. 24 months at 15-min interval, +25 °C) |
| Wireless Protocol | Wi-Fi (802.11 b/g/n), MQTT, SNTP time sync |
| Encryption | WEP / WPA / WPA2 / WPA2 Enterprise |
| Cloud Communication Interval | Basic: fixed 15 min |
| Advanced | adjustable 1 min – 24 h |
| Measurement Interval | Basic: fixed 15 min |
| Advanced | adjustable 1 min – 24 h |
| Data Retention (Cloud) | Basic: 3 months |
| Advanced | up to 24 months |
| Alarm Types | Upper/lower limit, delay alarm, system alarms (low battery, WLAN disconnection, power failure) |
| Notification Methods | Email (Basic & Advanced), SMS (Advanced only, 25 messages/year/device) |
| API Access | Yes |
| Compliance | Designed for GLP/GMP environments |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2031 |
| Channel Count | Single-channel |
| Measurement Range | −30 to +50 °C |
| Accuracy | ±0.5 °C |
| Resolution | 0.1 °C |
| Storage Capacity | 10,000 readings |
| IP Rating | IP65 |
| Battery | 4 × AA (24-month typical life at +25 °C, 15-min interval) |
| Wireless Protocol | MQTT over Wi-Fi (WEP/WPA/WPA2/WPA2 Enterprise supported) |
| Time Sync | SNTP-capable |
| Compliance | EN 12830 certified (TÜV-tested) |
| Cloud Communication Interval | 1 min – 24 h (Advanced license) |
| Operating Temperature | −30 to +50 °C |
| Dimensions | 95 × 75 × 30.5 mm |
| Weight | 240 g |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2103 |
| Channels | Dual-channel |
| Measurement Range | -50 to +150 °C |
| Accuracy | ±0.5 °C |
| Resolution | ±0.1 °C |
| IP Rating | IP65 |
| Weight | 240 g |
| Dimensions | 95 × 75 × 30.5 mm |
| Operating Temperature | -30 to +50 °C |
| Storage Temperature | -40 to +70 °C |
| Battery Life | Up to 12 months (typical, at +25 °C, 15-min measurement interval) |
| Memory Capacity | 10,000 data points |
| Power Supply | 4 × AA batteries (Energizer L91 recommended below -10 °C) |
| Compliance | EN 12830 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2032 |
| Channel Count | Multi-channel (2× NTC + 1× door contact) |
| IP Rating | IP65 |
| Compliance | DIN EN 12830 certified by TÜV |
| Measurement Range (NTC) | −50 to +150 °C |
| Accuracy | ±0.3 °C |
| Resolution | 0.1 °C |
| Memory Capacity | 2 × 10,000 values |
| Power Supply | 4× AA batteries (typical 24-month life at 25 °C, 15-min interval) |
| Operating Temperature | −30 to +50 °C |
| Storage Temperature (without battery) | −40 to +70 °C |
| Wireless Protocol | MQTT over WLAN (WEP/WPA/WPA2/WPA2 Enterprise supported) |
| Time Sync | SNTP-capable |
| Cloud Integration | testo Cloud (Basic free tier |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 2033 |
| Channel Count | 2-channel |
| Communication | Wi-Fi (802.11 b/g/n), MQTT protocol, SNTP time sync |
| Enclosure Rating | IP54 |
| Operating Temperature | -30 to +50 °C |
| Storage Capacity | 2 × 10,000 measurements |
| Battery | 4 × AA (24-month typical life) |
| Thermocouple Types Supported | K, T, J |
| Temp. Range (K) | -195 to +1350 °C |
| Temp. Range (T) | -200 to +400 °C |
| Temp. Range (J) | -100 to +750 °C |
| Accuracy | ±(0.5 + 0.5 % of reading) °C |
| Resolution | 0.1 °C |
| Cloud Reporting | Basic (free, 3-month retention, 15-min interval) / Advanced (2-year retention, 1-min interval, SMS alerts, API, multi-user support) |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 9320 |
| Channel Capacity | Up to 3,000 measurement channels |
| Power Backup | Integrated rechargeable emergency battery |
| Connectivity | Ethernet, Wi-Fi, testo UltraRange™ long-range encrypted radio (optional module) |
| Alarm Outputs | Visual alerts, email/SMS notifications, relay-triggered audible/visual alarms |
| Compliance | Designed for GxP environments (aligned with EU GMP Annex 15, FDA 21 CFR Part 11, ISO 14644, and ICH Q5C temperature/humidity monitoring requirements) |
| Included | Base unit, built-in rechargeable battery, charging cable |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Channel Type | Imported |
| Category | Multi-Channel Temperature & Humidity Data Logger and Controller |
| Compliance | Designed for HACCP, ISO 22000, and FDA Food Code compliance |
| Brand | Testo |
|---|---|
| Origin | Germany |
| Model | 0646 0073 |
| Temperature Range | +116 to +138 °C |
| Accuracy | ±1.5 °C |
| Operating Ambient Temperature | +116 to +138 °C |
| Dimensions | 15 mm diameter |
| Weight | 1 g |
| Quantity per Pad | 10 units |
| Indication Points | +116, +122, +128, +132, +138 °C (customizable thresholds per variant) |
| Response Time | ≤3 seconds upon exceeding threshold |
| Irreversible Visual Indication | Yes |
| Compliance | CE-marked, RoHS-compliant, designed for industrial process monitoring and cold chain validation |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0554 9313 01 |
| Channel Count | Multi-channel |
| Communication Protocols | UltraRange proprietary long-range radio, Ethernet, WLAN |
| Compliance | CE, RoHS, EN 300 328, EN 301 489 |
| Integration | Designed exclusively for testo 150 data logger platform |
| Enclosure Rating | IP20 |
| Operating Temperature | 0 °C to +50 °C |
| Power Supply | 12–24 V DC via testo 150 base unit |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0572 9310 |
| Channel Capacity | Up to 40 testo 150 data logger modules |
| Communication Interface | Ethernet (RJ45), UltraRange proprietary long-range wireless protocol (868 MHz, encrypted) |
| Power Supply | External (not included) |
| Compliance | CE, RoHS, EN 300 220-1, EN 301 489-1/17 |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0554 9313 02 |
| Channel Capacity | Multi-Channel |
| Compliance | CE, RoHS, FCC Part 15 Subpart C (for US deployment) |
| Operating Frequency | 868 MHz (EU), 915 MHz (US) |
| Max Line-of-Sight Range | Up to 2 km (outdoor, unobstructed) |
| Indoor Penetration | Up to 15 concrete floors or equivalent attenuation |
| Data Encryption | AES-128 |
| Protocol | Proprietary ultra-low-power TDMA-based mesh-capable radio protocol |
| Interface | SPI + UART for integration with testo 150 series data loggers |
| Firmware Upgradable | Yes, via Saveris Cloud or local gateway |
| Brand | testo |
|---|---|
| Origin | Germany |
| Model | 0554 9320 |
| Communication Interface | IEEE 802.11 b/g/n (2.4 GHz) |
| Security Protocol | WPA2-PSK, TLS 1.2 |
| Operating Temperature | 0–50 °C |
| Humidity Range | 10–90 % RH non-condensing |
| Certifications | CE, FCC, IC, RCM |
| Integration | Plug-and-play with testo 150 modular system |
| Channel Capacity | Supports multi-channel environmental monitoring (temperature, humidity, CO₂, differential pressure, etc.) |
| Compliance | Designed for GxP environments |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported |
| Model | Temp JKT |
| Price | Upon Request |
| Thermocouple Types | J, K, T |
| Temperature Range | –250 °C to 1372 °C (K-type), –250 °C to 400 °C (T-type), –2.00 °C to 1000 °C (J-type) |
| Resolution | 0.1 °C (–99.9 °C to 299.9 °C) |
| Accuracy | ±0.2% of reading + 0.5 °C (t > –99.9 °C) |
| Offset Adjustment | ±10 °C |
| Display | LCD |
| Power | 4 × 1.5 V AAA alkaline batteries |
| Battery Life | >200 hours |
| Operating Temperature | –10 °C to 50 °C |
| Dimensions (unit) | 140 × 70 × 35 mm |
| Weight (unit) | 200 g |
| Input Connector | 2-pin ANSI mini thermocouple interface |
| Data Hold | Yes |
| Auto Power-Off | Yes |
| Low-Battery Indicator | Yes |
| Factory-Calibrated | Yes |
| Self-Diagnostic Functions | Yes |
| Key-Based Calibration | Yes |
| Power-Save Mode | Yes |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TL1-A |
| Temperature Range | -10°C to 160°C |
| Accuracy | ±0.07°C (-10°C to 160°C), ±0.1°F (14°F to 320°F) |
| Resolution | 0.01°C |
| Operating Ambient Temperature | -20°C to 54°C (-4°F to 130°F) |
| Display | 0.25" LCD |
| Power Supply | 3V CR2032 coin cell battery |
| Probe Length | 20 cm (8"), Probe Diameter: 6.35 mm (1/4"), Tip Diameter: 4.76 mm (3/16") |
| Enclosure | Anodized aluminum housing (3.5" × 12"), silicone-sealed |
| Weight | 93 g (3.3 oz) |
| Auto-off | After 20 minutes of inactivity or continuous operation |
| Units | Switchable °C / °F |
| Sensor Material | Stainless steel |
| Thermal Response Time (in water bath) | 14 seconds |
| Battery Life | ~400 hours at 21°C (70°F) |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TL1-R |
| Temperature Range | -18°C to 150°C |
| Accuracy | ±0.04°C or ±0.07°F |
| Resolution | 0.001°C |
| Operating Ambient Temperature | -20°C to 54°C (-4°F to 130°F) |
| Display | 0.25-inch LCD |
| Power Supply | 3V CR2032 lithium coin cell |
| Probe Length | 20 cm (8 in), Diameter: 6.35 mm (1/4 in) |
| Weight | 124 g |
| Sensor Type | 200 Ω wound-wire Pt RTD |
| Immersion Depth | 11 cm (4 in) |
| Response Time | ≤3 min to ±0.1°C in water bath (0–50°C) |
| Auto-off | After 20 min idle or continuous operation |
| Units | Switchable °C/°F |
| Enclosure | Anodized aluminum housing (3.5" × 12"), silicone-sealed |
| Battery Life | 400 hours at 21°C (70°F) |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TL1-W |
| Temperature Range | -10°C to 160°C |
| Accuracy | ±0.1°F |
| Resolution | 0.01°C |
| Operating Ambient Temperature | -20°C to 54°C (-4°F to 130°F) |
| Display | 0.25-inch LCD |
| Power | 3V CR2032 lithium coin cell battery |
| Probe Length | 20 cm (8 in), Probe Diameter: 6.35 mm (1/4 in), Tip Diameter: 4.76 mm (3/16 in) |
| Enclosure | Aluminum housing (3.5" × 12"), silicone-sealed |
| Weight | 180 g |
| Sensor Type | 100 Ω, Class A 1/3 DIN RTD |
| Immersion Depth | 11 cm (4 in) |
| Stabilization Time in Water Bath | 14 s |
| Battery Life | 400 h at 21°C (70°F) |
| Intrinsic Safety Rating | II 2 G EEx ib IIB T4 |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TL2 |
| Temperature Range | -20 to 150°C |
| Accuracy | ±0.03°C (at ambient, NIST-traceable) |
| Resolution | 0.001°C |
| Display | LCD |
| Power Supply | Internal rechargeable battery (50 h typical life) |
| Operating Ambient Temperature | -20°C to +54°C |
| Enclosure | Powder-coated steel, IP65-rated |
| Dimensions | 184 × 133 × 57 mm (7.25" × 5.25" × 2.25") |
| Weight | 1000 g |
| Sensor Interface | Standard 5-pin DIN connector, compatible with 200 Ω 4-wire RTD probes |
| Compliance | NIST-traceable calibration certificate included |
| Brand | ThermoProbe |
|---|---|
| Origin | Germany |
| Model | TL3 |
| Temperature Range | -40 °C to 204 °C ±0.06 °C |
| Accuracy | ±0.06 °C |
| Resolution | 0.01 °C |
| Operating Ambient Temperature | -20 °C to 54 °C |
| Display | 0.5-inch LCD with low-battery and error indicators |
| Power | CR2032 3 V lithium coin cell |
| Probe Length | 200 mm or 300 mm |
| Probe Diameter | 6.35 mm (shaft), 4.76 mm (tip) |
| Weight | 150 g |
| Stabilization Time in Water Bath | 6.5 s |
| Battery Life | >100 h at 21 °C |
| Battery Operating Temp Range | -20 °C to 54 °C |
| Compliance | NIST-traceable 4-point calibration certificate included |
| Warranty | 1 year |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TP5C |
| Temperature Range | -40°C to +204°C |
| Accuracy | ±0.2°F (-40°F to 200°F), ±0.5°F (200°F to 400°F) |
| Resolution | 0.1°C |
| Operating Ambient Temperature | -20°C to +54°C (-4°F to 130°F) |
| Display | LCD |
| Power Supply | 3V CR2032 coin cell battery |
| Dimensions | 9.5"L × 7.2"H × 1.76"W in (241 mm × 183 mm × 45 mm) |
| Weight | 124 g |
| Probe Material | 304 Stainless Steel |
| Safety Certification | UL Listed for Class I, Division 1, Groups B, C, D |
| Calibration | NIST-traceable 4-point calibration report |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TP7-C |
| Temperature Range | −10 °C to 188 °C (14 °F to 370 °F) |
| Accuracy | ±0.2 °F (32–200 °F), ±0.5 °F (200–300 °F) |
| Resolution | 0.1 °C |
| Operating Ambient Temperature | −20 °C to 54 °C |
| Display | LCD |
| Power | 9 V alkaline battery (≈50 h life) |
| Dimensions | 34.3 × 18.4 × 11.4 cm |
| Weight | 1.4 kg (with 23 m cable) |
| Sensor | Pt100 platinum RTD in stainless steel sheath |
| Cable | FEP/PFA-insulated, aramid-reinforced, static-dissipative jacket |
| Enclosure Materials | Polypropylene blend, stainless steel, aluminum |
| Safety Certification | ATEX II 2 (1) EEx ib[ia] IIB T4 |
| Compliance | API RP 14C, IEC 60079-0/-11, UL 913 Class I, Div 1, Groups B, C, D |
| Brand | Thermoprobe |
|---|---|
| Origin | USA |
| Model | TP9 |
| Temperature Range | -40°C to 204°C |
| Accuracy (Calibrated) | ±0.1°C (0–100°C), ±0.3°C (100–200°C), ±0.5°C (200–204°C) |
| Long-Term Drift | ≤0.05%/year |
| Resolution | 0.1°C |
| Operating Ambient Temperature | -20°C to +54°C |
| Display | LCD |
| Power Supply | 3V CR2032 coin cell battery |
| Dimensions | 254 mm L × 108 mm H × 163 mm W |
| Weight | 2.0 kg |
| Enclosure Material | Anodized aluminum housing with stainless steel fasteners |
| Probe Construction | 304 stainless steel sensor tip, reinforced aramid fiber cable jacket (FEP or PFA), coaxial design |
| Certification | ATEX II 2 (1) EEx ib[ia] IIB T4 |
| Compliance | API RP 14C, NIST-traceable 4-point calibration certificate included |
| Brand | AS ONE |
|---|---|
| Origin | Japan |
| Manufacturer | AS ONE Corporation |
| Model No. | 1-6124-81 |
| Temperature Range | 0–500 °C |
| Sensor Type | K-type Thermocouple |
| Display | Dual-digit LED (PV/SV) |
| Control Method | PID with Auto-Tuning & Over-Temperature Suppression |
| Output Terminal | 2P Socket + M4 Screw Terminal |
| Load Capacity | Up to 1000 W (Resistive Load) |
| Power Supply | AC 220 V |
| Dimensions | 135 × 110 × 82 mm |
| Included Accessory | K-type Thermocouple (φ3.2 mm × 200 mm, SUS304 Sheath, 1.9 m Cable) |
| Temperature Indication Accuracy | ±max(0.3% of SV, 3 °C) |
