| Key | High-Temp Zone: +60 °C to +200 °C |
|---|---|
| Low-Temp Zone Options | −10 °C to −40 °C / −10 °C to −60 °C / −10 °C to −70 °C |
| Test Chamber Range | 0 °C to −40 °C / −10 °C to −55 °C / −10 °C to −65 °C |
| Temp. Fluctuation | ±0.5 °C |
| Temp. Uniformity | ±3 °C |
| Temp. Recovery Time | 3–5 min |
| Heat-up Rate (HT Zone) | ~5 °C/min (avg.) |
| Cool-down Rate (LT Zone) | ~1.5 °C/min (avg.) |
| Dwell Time per Stage | ≥30 min |
| Transfer Time (Chamber-to-Chamber) | ≤15 s |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 11,200 (approx.) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | −70 °C to +150 °C |
| Thermal Shock Conditions | −40 °C ↔ +70 °C and −55 °C ↔ +85 °C |
| Temperature Uniformity | ≤ ±2 °C |
| Temperature Stability | ≤ ±0.5 °C |
| Transfer Time (Cold ↔ Hot) | ≤ 5 s |
| Temperature Recovery Time | ≤ 5 min |
| Control Resolution | 0.1 °C / 1 s |
| Programmable Capacity | 10 programs × 99 segments |
| Compliance | GB/T 2423.22–1989, GJB 150.5A–2009, MIL-STD-810G Method 503.5 |
| Key Features | Three-zone design (high-temperature chamber, low-temperature chamber, test chamber) |
|---|---|
| Programmable memory | 100 test profiles, up to 9999 cycles, max 999 h 59 min per segment |
| Data logging | paperless real-time curve display and archival |
| Compliance | MIL-STD-202, IEC 60068-2-14, JIS C 60068-2-14 |
| Optional | LN₂ rapid-cooling module, RS-485/RS-232C communication interface, external temperature data logger |
| Safety | PLC-controlled fault detection, automatic emergency shutdown on power fluctuation, dual thermal overprotection |
| Key Features | Three-zone design (hot zone, cold zone, test zone) |
|---|---|
| Temperature Range | Hot Zone: +80°C to +200°C |
| Cold Zone | −10°C to −70°C |
| Test Zone Operating Range | −10°C to +150°C |
| Temperature Control Accuracy | ±2°C |
| Resolution | 0.1°C |
| Hot Zone Ramp Rate | ~60 min (from ambient to +150°C) |
| Cold Zone Ramp Rate | ~120 min (from ambient to −60°C) |
| Test Zone Recovery Time | ≤3 min (with standard 2 kg I.C. load) |
| Internal Dimensions (Test Zone) | 500 × 350 × 500 mm (W×H×D) |
| External Dimensions | Approx. 1600 × 2050 × 2220 mm (W×H×D) |
| Construction | SUS304 stainless steel interior |
| Exterior | High-tensile cold-rolled steel with solvent-free powder coating |
| Insulation | Fire-retardant PU foam + glass wool, 100 mm thick |
| Compliance | GB10592–1989, GB2423.1, GB2423.2, GJB150.3, GJB150.4, IEC 60068-2-14, MIL-STD-810G |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Temperature Range | High Zone: +150°C to +200°C |
| Low Zone | -70°C to -40°C |
| Test Zone | -65°C to +180°C |
| Transition Time (5% Recovery) | ≤15 s (Typical, per IEC 60068-2-14) |
| Cycle Count | Up to 9999 Cycles |
| Soak Time per Zone | Adjustable 1–9999 min |
| Cooling System | Dual-Stage Cascade Refrigeration (Air-Cooled or Water-Cooled Options) |
| Control Interface | 7″ Full-Color TFT LCD Touchscreen with Bilingual (English/Chinese) GUI |
| Data Logging | Optional External Recorder or PC-Connected USB/RS485 Interface |
| Compliance | IEC 60068-2-14 (Test N), MIL-STD-810H Method 503.5, GJB 150.5A-2009, GB/T 2423.22–2012, ASTM D6279–20 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB China) |
| Internal Dimensions (W×H×D) | 40×35×30 cm to 70×60×60 cm |
| External Dimensions (W×H×D) | 145×180×140 cm to 190×170×270 cm |
| Hot Zone Temperature Range | RT to +200 °C |
| Cold Zone Temperature Range | RT to −70 °C |
| Test Zone Temperature Range | +60 °C to +150 °C (hot shock) |
| Switching Mechanism | Pneumatic air-door actuated, static sample placement |
| Preheat Time (RT → 150 °C) | ~30 min |
| Precool Time (RT → −70 °C) | ~85 min |
| Recovery Time | <5 min |
| Temperature Control Accuracy | ±0.5 °C |
| Temperature Uniformity | ±2.0 °C |
| Refrigeration System | Dual-stage cascade refrigeration with semi-hermetic German compressors (R404A/R23), water-cooled condenser requiring external 10 m³/h cooling tower |
| Inner Chamber Material | Mirror-finish SUS#304 stainless steel |
| Outer Chamber Material | SUS#304 stainless steel or powder-coated steel |
| Insulation | High-density, fire-retardant PU foam |
| Standard Accessories | One 50 mm diameter cable port |
| Power Supply | AC 380 V ±5 %, 50 Hz ±0.5 Hz, 3-phase 5-wire, 2.5 m cable |
| Brand | OK |
|---|---|
| Model | OK-HH-49 / OK-HH-80 / OK-HH-150 / OK-HH-225 |
| Type | Three-Zone (Hot/Cold/Test) or Two-Zone (Hot/Cold with Basket Transfer) Thermal Shock Test Chamber |
| Internal Dimensions (W×H×D, cm) | 40×35×30 to 70×60×60 |
| External Dimensions (W×H×D, cm) | 145×180×140 to 190×170×270 |
| Hot Zone Temperature Range | RT to +200 °C |
| Cold Zone Temperature Range | RT to −70 °C |
| Test Zone Temperature Range | +60 °C to +150 °C (hot shock) |
| Temperature Uniformity | ±2.0 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Shock Transition Time (Door Switching) | <5 min |
| Hot Zone Preheat Time (RT→150 °C) | ~30 min |
| Cold Zone Precool Time (RT→−70 °C) | ~85 min |
| Refrigeration System | Dual-stage cascade refrigeration with imported semi-hermetic compressors (Germany), R404A/R23 refrigerants |
| Cooling Water Requirement | 10 m³/h external cooling tower (user-supplied) |
| Construction | Interior – mirror-finish SUS#304 stainless steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Accessories | One φ50 mm cable port |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Temperature Range (Hot Zone) | RT to +200 °C |
| Temperature Range (Cold Zone) | RT to −70 °C |
| Test Zone Range | +60 °C to +150 °C (Hot Shock) |
| Switching Method | Pneumatic Air-Damper–Actuated Static Specimen Transfer |
| Recovery Time | <5 min |
| Temperature Uniformity | ±2.0 °C |
| Control Accuracy | ±0.5 °C |
| Refrigeration System | Dual-Stage Cascade with Semi-Hermetic German Compressors (R404A/R23) |
| Insulation | High-Density Fire-Retardant PU Foam |
| Interior Material | Mirror-Finish SUS304 Stainless Steel |
| Exterior Material | SUS304 or Powder-Coated Steel |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-Phase 5-Wire |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Temperature Range (Hot Zone) | RT to +200 °C |
| Temperature Range (Cold Zone) | RT to −70 °C |
| Test Zone Range | +60 °C to +150 °C (hot shock), 0 °C to −45/−55/−65 °C (cold shock) |
| Switching Mechanism | Pneumatic air-door actuated static sample transfer |
| Recovery Time | ≤5 min |
| Temperature Uniformity | ±2.0 °C |
| Temperature Control Accuracy | ±0.5 °C |
| Refrigeration System | Dual-stage cascade with semi-hermetic compressors (R404A/R23) |
| Internal Construction | Mirror-finish SUS304 stainless steel |
| Insulation | High-density fire-retardant PU foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Compliance | GB/T 2423.1–2022, GB/T 2423.2–2022, GB/T 2423.22–2022, GJB 150.3–2009, GJB 150.4–2009, GJB 150.5–2009, IEC 60068-2-14 (Test N), QC/T 17–1992, EIA-364-32 |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 12,500 (FOB) |
| Temperature Range Options | A: −20°C to 200°C |
| B | −40°C to 200°C |
| C | −60°C to 200°C |
| Temperature Uniformity in Test Zone | ≤ ±0.5°C (at steady state) |
| High/Low Chamber Temp Stability | ≤ ±2°C |
| Test Zone Dimensions | 450 mm (W) × 300 mm (H) × 300 mm (D) |
| Load Capacity | 20 kg / 30 kg / 50 kg (configurable) |
| Hot Zone Ramp Rate | ~30 min from ambient to 100°C |
| Cold Zone Ramp Rate | ~90 min from ambient to −50°C |
| Transfer Cycle Time | ~6 min (ambient → −40°C), ~5 min (−40°C → ambient), ~5 min (ambient → 85°C) |
| Insulation | High-density fiberglass + fire-retardant PU foam with K-type anti-sweat ducting |
| Construction | Interior & exterior SUS304 stainless steel |
| Actuation | Japanese linear pneumatic cylinder for thermal zone valve control |
| Compliance | Designed to meet ASTM D5229, IEC 60068-2-14, MIL-STD-810H Method 503.7, JIS C 60068-2-14, and CNS 12520 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Cooling Capacity | Dual-Stage Cascade Refrigeration System |
| Compressor | Imported Semi-Hermetic German Compressor |
| Cooling Water Requirement | 10 m³/h External Cooling Tower (User-Supplied) |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–2002, GJB 150.5–86, IEC 60068-2-14, EIA-364-32, QC/T 17–92 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 11,200 (FOB) |
| Power Supply | AC 380 V ±10%, 50/60 Hz |
| Refrigerants | R404A & R23 (EPA-approved) |
| Compressor | Tecumseh or Copeland High-Performance Hermetic Units |
| Cooling System | Dual-Stage Cascade Mechanical Refrigeration with Water-Cooled Condenser |
| Temperature Control | Touchscreen LCD Controller with RS232 Interface |
| Compliance | GB/T 2423.1–1989 (Test A), GB/T 2423.2–1989 (Test B), IEC 60068-2-1, MIL-STD-2164A, GJB 1032–1990, GJB 234–1985 |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Distributor |
| Origin Category | Domestic |
| Model | TS2 / TS3 |
| Pricing | Upon Request |
| High-Temperature Range | +60 °C to +200 °C |
| Low-Temperature Range | 0 °C to –55 °C or 0 °C to –65 °C |
| Temperature Transition Time | ≤10 s |
| Temperature Recovery Time | 3–5 min |
| Test Load Capacity | 1.0–20.0 kg |
| Internal Chamber Dimensions (W×D×H) | 200×200×150 mm to 650×500×400 mm |
| Compliance | MIL-883E, IEC 60068-2-14, JIS C 60068-2-14 |
| Key Features | Dual-chamber design (hot/cold) with pneumatic door switching |
|---|---|
| Temperature Range | Hot Zone RT to +200°C, Cold Zone RT to −70°C |
| Test Zone Range | +60°C to +150°C (heat shock), 0°C to −45/−55/−65°C (cold shock) |
| Temperature Uniformity | ±2.0°C |
| Temperature Control Accuracy | ±0.5°C |
| Recovery Time | <5 min |
| Preheating Time (RT→150°C) | ~30 min |
| Precooling Time (RT→−70°C) | ~85 min |
| Refrigeration System | Twin-stage cascade refrigeration using R404A/R23 |
| Construction | Interior – SUS#304 mirror-finish stainless steel |
| Insulation | High-density fire-retardant PU foam |
| Power Supply | AC 380 V ±5%, 50 Hz ±0.5 Hz, 3-phase 5-wire |
| Optional Customization | Internal dimensions scalable per user requirements |
| [Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 11,200 (approx. based on ¥80,000 at 1 USD = ¥7.15) |
| Compliance | GB/T 2423.1–2001, GB/T 2423.2–2001, GB/T 2423.22–2002, GJB 150.5–86, IEC 60068-2-14, QC/T 17–92, EIA-364-32 |
| Cooling System | Dual-stage cascade refrigeration with imported German semi-hermetic compressors |
| Cooling Requirement | External 10 m³/h water-cooled cooling tower] |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 11,200 (FOB) |
| Cooling System | Dual-Stage Cascade Refrigeration with Imported German Semi-Hermetic Compressors |
| Cooling Water Requirement | External 10 m³/h Cooling Tower (User-Supplied) |
| Compliance | GB/T 2423.1–2008, GB/T 2423.2–2008, GB/T 2423.22–2002, GJB 150.5–2009, IEC 60068-2-14, MIL-STD-810G Method 503.5, QC/T 17–1992, EIA-364-32 |
| Brand | OEM / Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Brand | OEM |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 11,200 (FOB) |
| Control System | TEMI880 Color Touchscreen Programmable Controller (English/Chinese Switchable) or TEMI300 Membrane Keypad Controller (English Only) |
| Protection Features | Compressor Overheat/Overcurrent/High-Pressure Protection |
| Standard Equipment | Dual-Layer Tempered Glass Viewing Window |
| Temperature/Humidity Control | Balanced Temperature and Humidity Control System (BTSC) |
| Operating Ambient | +5°C to +35°C |
| Heater | Nickel-Chromium Alloy Wire |
| Humidifier | Surface Evaporation Type |
| Blower | Centrifugal Fan |
| Airflow Pattern | Wide-Band Forced Circulation (Top-Out/Bottom-In) |
| Condensation Method | Air-Cooled |
| Refrigeration System | Hermetic “Tecumseh” (France) Compressor |
| Construction | Outer Shell: SUS304B Stainless Steel |
| Inner Chamber | Welded Austenitic Stainless Steel (Leak-Proof Seam Welding) |
| Sealing | Dual-Silicone Rubber Gasket at Door |
| Insulation | High-Density Mineral Wool (Low Thermal Conductivity) |
| Internal Fans | Axial-Flow Circulation Fans (Quantity Configured per Chamber Volume) |
| Cable Port | One φ50 mm Penetration Port (Left Wall) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 14,000 (approx.) |
| (在此处输出精准翻译� | �纯英文产品名称。极其重要:仅输出一行名称,严禁输出备选名、严禁换行重复、严禁包含任何中文字符) |
|---|---|
| [Brand | Other Brands |
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | -60°C to +80°C (selectable low-temp options: 0°C, -20°C, -40°C, -60°C) |
| Humidity Range | 20–98% RH (optional extended ranges: 5–98%, 10–98%, 20–98% RH) |
| Control System | Microprocessor-based PID + SSR + Timer |
| Compliance | GB/T 2423.1, GB/T 2423.2, GB/T 2423.22, GJB 150.5, GJB 360.7-87, GJB 367.2-87, IEC 60068-2-14, QC/T 17-92, EIA-364-32 |
| Construction | Inner chamber – SUS304B stainless steel |
| Origin | Guangdong, China |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic (China) |
| Model | WGD40 |
| Pricing | Available Upon Request |
| Temperature Range | −40 °C to +100 °C (optional up to +150 °C) |
| Temperature Uniformity | ±1.5 °C |
| Temperature Stability | ±0.5 °C |
| Heating Rate | −40 °C → +100 °C in ≈55 min |
| Cooling Rate | +20 °C → −40 °C in ≈60 min |
| Internal Volume | 408 L |
| Inner Dimensions (W×D×H) | 600 × 800 × 850 mm |
| Construction | SUS304 Stainless Steel Interior, Powder-Coated Cold-Rolled Steel Exterior |
| Insulation | High-Density Polyurethane Foam + Glass Wool |
| Refrigeration System | Single-Stage Mechanical Compression (R507) or Dual-Stage Cascade (R404A/R23) |
| Controller | LED-Based Programmable PID Controller, 4 Programs × 10 Segments, 9999 Cycles |
| Compliance | GB/T 10589, GB/T 11158, GB/T 10592, GB/T 2423.1–2423.22, IEC 60068-2-1/2/14, GJB 150.3/150.4 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Temperature Range | Low Temp Options: +25°C / 0°C / −20°C / −40°C / −60°C / −70°C |
| High Temp Options | 100°C / 150°C |
| Humidity Range | 5–98% RH (optional) |
| Temperature Resolution & Uniformity | 0.1°C / ±2.0°C |
| Humidity Resolution & Uniformity | 0.1% RH / ±3.0% RH |
| Temperature Control Accuracy | ±0.5°C / ±2.5% RH |
| Heating Rate | ~4.0°C/min |
| Cooling Rate | ~1.0°C/min |
| Interior/Exterior Material | SUS304 Stainless Steel |
| Refrigeration System | French Tecumseh Compressor with R404A Eco-Friendly Refrigerant |
| Viewing Window | Double-layered, anti-fog heated tempered glass with LED lighting |
| Controller | Imported LCD touchscreen interface supporting multi-segment programmable ramp/slope and step profiles |
| Structural Features | Rounded ergonomic housing, flat non-reactive door handle, double-gasketed airtight door seal, adjustable stainless steel shelves, external test port for signal/power feedthrough, integrated casters with locking mechanism |
| Optional Functions | External water supply system with automatic condensate recovery, humidity control capability |