| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | UltiMate 3000 RSLCo |
| Instrument Type | Nano-LC System |
| Flow Range | 50 nL/min – 50 µL/min (nano to capillary/micro) |
| Auxiliary Microflow Pump | up to 2500 µL/min |
| Maximum Pressure | 860 bar |
| Technology | ProFlow™ Nanoflow Control, oViper™ Hand-Tight Fitting, Dual Gradient Architecture (High-Pressure Binary + Microflow Ternary) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICS-1100 |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Operating Pressure Range | Up to 5000 psi |
| Column Oven Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM (KOH), adjustable per eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Vanquish Duo |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Configurations | Dual-Gradient LC, Tandem LC, LC-MS Coupling, Back-Flush Gradient LC |
| Software Platform | Thermo Scientific Chromeleon CDS (FDA 21 CFR Part 11 Compliant) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TraceFinder |
| Price Range | USD $6,800 – $13,600 (est. based on ¥50,000–¥100,000 at 1 USD ≈ ¥7.35) |
| Software Type | Mass Spectrometry Data Acquisition & Processing Platform |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | iCAP RQplus ICP-MS |
| Price | Upon Request |
| Application Environment | Laboratory |
| Mass Range (amu) | 2–290 |
| Unit Mass Resolution (amu) | 2–290 |
| Instrument Detection Limits (ng·L⁻¹) | Be < 0.5, In < 0.1, Bi < 0.1 |
| Sensitivity (Mcps / mg·L⁻¹) | Li > 65, Co > 110, In > 270, U > 400 |
| Short-Term Stability (RSD, 10 min) | < 2% |
| Long-Term Stability (RSD, 2 h) | < 3% |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | LC IsoLink |
| Instrument Category | Dedicated HPLC–IRMS Interface System |
| Measurement Precision | High-precision isotopic ratio detection (δ¹³C, δ²H, δ¹⁵N, δ¹⁸O achievable with <0.2‰ 1σ reproducibility under optimized conditions) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TRACE 1310 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | +3 °C to 450 °C |
| Injector Maximum Operating Temperature | 450 °C |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Q Exactive UHMR |
| Instrument Type | Quadrupole-Orbitrap Hybrid Mass Spectrometer |
| Mass Range | Up to 80,000 m/z |
| Precursor Selection Range | Up to 25,000 m/z |
| Ion Transmission | Enhanced In-Source Capture |
| Fragmentation | HCD in Injection Flatapole Cell |
| Application Focus | Native MS, Top-Down Proteomics, Intact Protein & Mega-Dalton Complex Analysis |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Accela |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Maximum Operating Pressure | 1250 bar (18,130 psi) |
| Flow Rate Range | 0.001–2.000 mL/min |
| Gradient Delay Volume | ≤70 µL |
| Flow Accuracy | ≤±0.5% |
| Gradient Accuracy | ≤±0.5% |
| Pressure Ripple | <0.5 bar (peak-to-peak) |
| Typical Peak Width (FWHM) | <1 s |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Orbitrap Astral Zoom Mass Spectrometer |
| Instrument Type | Orbitrap Mass Spectrometer |
| Application Scope | Specialized |
| Mass Range | m/z 40–6000 |
| Sensitivity | SIM mode — 50 fg on-column reserpine, S/N ≥ 150:1 |
| MS/MS mode — 50 fg on-column reserpine, S/N ≥ 100 | 1 |
| Resolution | 100,000 FWHM at m/z 138 |
| Mass Accuracy | <5 ppm RMS |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Operating Pressure | 150 MPa (22,000 psi) |
| Sample Capacity | 8832 positions |
| Injection Volume Range | 0.01–100 µL |
| Column Oven Temperature Range | 5–120 °C |
| Data Acquisition Rate | 200 Hz |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported Instrument |
| Model | NEPTUNE Plus |
| Price Range | USD 680,000 – 950,000 (FOB Hamburg) |
| Instrument Type | Magnetic Sector Mass Spectrometer |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | ICS-4000 |
| Pump Pressure Rating | 6000 psi |
| Flow Rate Range | 0.001–0.100 mL/min |
| Eluent Flow Rate | 0.001–0.100 mL/min |
| Maximum Operating Pressure | 6000 psi |
| Operating Temperature Range | 10°C–40°C |
| Temperature Reproducibility | ±0.2°C |
| Eluent Concentration Range | 0–100 mM (KOH), dependent on eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | UltiMate 3000 Binary Rapid Separation System (U3000) |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Maximum Flow Rate | 8 mL/min |
| Maximum Backpressure | 100 MPa (15,000 psi / 1000 bar) |
| Column Oven Temperature Range | 5–110 °C |
| Gradient Delay Volume | Adjustable via SpinFlow™ Technology |
| Autosampler Injection Precision | <0.25% RSD |
| Carryover | <0.005% |
| Detector Compatibility | UV-Vis (DAD, MWD, VWD), Fluorescence, CAD, RID, MS interfaces |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | iCAP MTX ICP-MS |
| Application | Laboratory-based elemental and isotopic analysis |
| Mass Range (amu) | 2–290 u (m/z >225 available only with intelligent Mass Resolution [iMR] enabled) |
| Resolution (Unit Mass Resolution, amu) | User-configurable |
| Detection Limits (ng·L⁻¹) | ⁹Be <0.3, ¹¹⁵In <0.1, ²⁰⁹Bi <0.1 |
| TQ-O₂ mode | ³²S (as SO⁺) <50, ³¹P (as PO⁺) <15, ⁷⁸Se (as SeO⁺) <1, ²⁸Si (as SiO⁺) <50 |
| Sensitivity (Mcps/mg·L⁻¹) | Standard Mode: ⁷Li 65, ⁵⁹Co 180, ¹¹⁵In 400, ²⁰⁹Bi 340, ²³⁸U 550 |
| KED Mode | ⁵⁹Co 60 |
| Short-term Stability (RSD, 10 min) | <2% |
| Long-term Stability (RSD, 2 h) | <3% |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported Instrument |
| Model | Orbitrap ID-X™ |
| Instrument Type | Orbitrap-based Tribrid™ Mass Spectrometer |
| Configuration | Integrated with Quadrupole, Linear Ion Trap, and Orbitrap™ Analyzers |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Instant Connect FID |
| Instrument Type | Flame Ionization Detector (FID) |
| Detection Limit (MDL) | <1.4 pg C/s |
| Sensitivity | >0.03 C/gC |
| Linear Dynamic Range | >10⁷ (±10%) |
| Maximum Operating Temperature | 450°C (0.1°C increment) |
| Carrier Gas Flow Control | N₂ or He, 0–50 mL/min (0.1 mL/min increment) |
| Hydrogen Flow Control | 0–100 mL/min (0.1 mL/min increment) |
| Air Flow Control (IEC) | 0–500 mL/min (0.1 mL/min increment) |
| Column Compatibility | 1/8″ and 1/16″ packed columns |
| Flame Monitoring | Auto-ignition and flame-out detection |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | iCAP TQ |
| Instrument Type | Triple Quadrupole ICP-MS |
| Quadrupole Configuration | Three Sequential Quadrupole Mass Filters |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | NPD Detector |
| Instrument Category | Element-Selective Chromatographic Detector |
| Compatibility | Designed for Thermo Scientific TRACE 1300/1310 GC and ISQ EC/LSQ MS platforms |
| Brand | Thermo Fisher |
|---|---|
| Origin | Mexico |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | Aquion |
| Pump Pressure Rating | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Column Oven Temperature Range | 30–60 °C |
| Temperature Reproducibility | ±0.5 °C |
| Eluent Concentration Range | 0.1–100 mM (dependent on eluent chemistry) |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TRACE 1300 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Pricing Range | USD 65,000 – 130,000 (FOB US Port) |
| Module Architecture | Plug-and-Play, User-Replaceable Inlet & Detector Modules |
| Compliance | Designed to support GLP/GMP workflows and 21 CFR Part 11–compliant data integrity requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Instrument |
| Model | Exactive LC/MS – Benchtop FT Orbitrap High-Resolution LC-MS |
| Instrument Category | Ion Trap |
| Price Range | USD 140,000 – 280,000 (based on configuration and regional duties/taxes) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | U3000 Standard Binary System |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Maximum Flow Rate | 8 mL/min |
| Maximum Backpressure | 100 MPa (15,000 psi / 1000 bar) |
| Column Temperature Range | 5–110 °C |
| Gradient Delay Volume | Adjustable via SpinFlow™ Technology |
| Autosampler Carryover | < 0.001% |
| Detector Compatibility | UV-Vis (DAD, MWD, VWD), Fluorescence, CAD, RID, MS |
| Brand | Thermo Fisher |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | UltiMate 3000 RSLC |
| Instrument Category | Rapid Separation Liquid Chromatography (RSLC) |
| Maximum Pressure | 1034 bar (15,000 psi) |
| Maximum Flow Rate | 8 mL/min |
| System Configurations | Binary, Quaternary, or Dual Triple-Quaternary Pump Options |
| Column Particle Size Compatibility | Down to 1.7 µm |
| Software Platform | Chromeleon CDS (Chromatography Data System) with Method Transfer & Development Tools |
| Fitting Technology | Viper™ fingertight fittings |
| Separation Speed Gain vs. Conventional HPLC | Up to 50× |