- All
- Favorite
- Popular
- Most rated
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | UltiMate 3000 RSLCo |
| Instrument Type | Nano-LC System |
| Flow Range | 50 nL/min – 50 µL/min (nano to capillary/micro) |
| Auxiliary Microflow Pump | up to 2500 µL/min |
| Maximum Pressure | 860 bar |
| Technology | ProFlow™ Nanoflow Control, oViper™ Hand-Tight Fitting, Dual Gradient Architecture (High-Pressure Binary + Microflow Ternary) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | ICS-1100 |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Operating Pressure Range | Up to 5000 psi |
| Column Oven Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM (KOH), adjustable per eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Vanquish Duo |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Application Configurations | Dual-Gradient LC, Tandem LC, LC-MS Coupling, Back-Flush Gradient LC |
| Software Platform | Thermo Scientific Chromeleon CDS (FDA 21 CFR Part 11 Compliant) |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Instrument |
| Model | TRACE 1310 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Oven Temperature Range | +3 °C to 450 °C |
| Injector Maximum Operating Temperature | 450 °C |
| Origin | USA |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Accela |
| Price Range | USD 28,000 – 70,000 |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Maximum Operating Pressure | 1250 bar (18,130 psi) |
| Flow Rate Range | 0.001–2.000 mL/min |
| Gradient Delay Volume | ≤70 µL |
| Flow Accuracy | ≤±0.5% |
| Gradient Accuracy | ≤±0.5% |
| Pressure Ripple | <0.5 bar (peak-to-peak) |
| Typical Peak Width (FWHM) | <1 s |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Flow Rate Range | 0.001–5.000 mL/min |
| Maximum Operating Pressure | 150 MPa (22,000 psi) |
| Sample Capacity | 8832 positions |
| Injection Volume Range | 0.01–100 µL |
| Column Oven Temperature Range | 5–120 °C |
| Data Acquisition Rate | 200 Hz |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | ICS-4000 |
| Pump Pressure Rating | 6000 psi |
| Flow Rate Range | 0.001–0.100 mL/min |
| Eluent Flow Rate | 0.001–0.100 mL/min |
| Maximum Operating Pressure | 6000 psi |
| Operating Temperature Range | 10°C–40°C |
| Temperature Reproducibility | ±0.2°C |
| Eluent Concentration Range | 0–100 mM (KOH), dependent on eluent chemistry |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | UltiMate 3000 Binary Rapid Separation System (U3000) |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Maximum Flow Rate | 8 mL/min |
| Maximum Backpressure | 100 MPa (15,000 psi / 1000 bar) |
| Column Oven Temperature Range | 5–110 °C |
| Gradient Delay Volume | Adjustable via SpinFlow™ Technology |
| Autosampler Injection Precision | <0.25% RSD |
| Carryover | <0.005% |
| Detector Compatibility | UV-Vis (DAD, MWD, VWD), Fluorescence, CAD, RID, MS interfaces |
| Brand | Thermo Fisher |
|---|---|
| Origin | Mexico |
| Manufacturer | Thermo Fisher Scientific |
| Product Type | Imported Laboratory Instrument |
| Model | Aquion |
| Pump Pressure Rating | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Column Oven Temperature Range | 30–60 °C |
| Temperature Reproducibility | ±0.5 °C |
| Eluent Concentration Range | 0.1–100 mM (dependent on eluent chemistry) |
| Brand | Thermo Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | TRACE 1300 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Pricing Range | USD 65,000 – 130,000 (FOB US Port) |
| Module Architecture | Plug-and-Play, User-Replaceable Inlet & Detector Modules |
| Compliance | Designed to support GLP/GMP workflows and 21 CFR Part 11–compliant data integrity requirements |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | U3000 Standard Binary System |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph (UHPLC) |
| Maximum Flow Rate | 8 mL/min |
| Maximum Backpressure | 100 MPa (15,000 psi / 1000 bar) |
| Column Temperature Range | 5–110 °C |
| Gradient Delay Volume | Adjustable via SpinFlow™ Technology |
| Autosampler Carryover | < 0.001% |
| Detector Compatibility | UV-Vis (DAD, MWD, VWD), Fluorescence, CAD, RID, MS |
| Brand | Thermo Fisher |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | UltiMate 3000 RSLC |
| Instrument Category | Rapid Separation Liquid Chromatography (RSLC) |
| Maximum Pressure | 1034 bar (15,000 psi) |
| Maximum Flow Rate | 8 mL/min |
| System Configurations | Binary, Quaternary, or Dual Triple-Quaternary Pump Options |
| Column Particle Size Compatibility | Down to 1.7 µm |
| Software Platform | Chromeleon CDS (Chromatography Data System) with Method Transfer & Development Tools |
| Fitting Technology | Viper™ fingertight fittings |
| Separation Speed Gain vs. Conventional HPLC | Up to 50× |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer | Thermo Fisher Scientific |
| Category | Imported Instrument |
| Model | AAA-Direct |
| Pricing | Upon Request |
| Pump Material | PEEK (chemically inert, pH 0–14 compatible) |
| Pump Type | Tandem dual-piston, constant stroke |
| Flow Rate Range | 0.001–10 mL/min |
| Flow Accuracy | <0.1% at 1.0 mL/min |
| Flow Precision | <0.1% RSD at 1.0 mL/min |
| Pressure Range | 50–5000 psi |
| Pressure Pulsation | ≤1% |
| Gradient Ratio Accuracy | ±0.5% at 2.0 mL/min |
| Gradient Ratio Precision | ±0.5% RSD at 2.0 mL/min |
| Eluent Options | Isocratic: 1 |
| Gradient | up to 4 |
| Gradient Delay Volume | <400 µL |
| EG Concentration Range | 0.01–100 mM |
| EG Compatible Eluents | KOH, LiOH, NaOH, CO₃²⁻/HCO₃⁻, CO₃²⁻, MSA |
| EG Concentration Increment | 0.01 mM |
| EG Flow Range | 0.1–3.0 mL/min |
| Max EG Operating Pressure | 3000 psi (21 MPa) |
| Organic Solvent Tolerance | Anion mode: ≤25% methanol |
| Cation mode | solvent-free aqueous only |
| Operating Temperature | 4–40 °C |
| Operating Humidity | 5–95% RH (non-condensing) |
| Dimensions (H×W×D) | 41×23×56 cm |
| Weight | 25 kg |
| Power | 90–265 V AC, 47–63 Hz |
| Ion Reservoir Dimensions | 23×7×10 cm, 1.6 kg |
| Cr-TC Trap Column | 3.8×3.8×5.8 cm, 60 g |
| Eluent Organizer (EO) | Holds four 1–2 L or two 4 L chemically resistant PE/epoxy-coated bottles |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish Flex Binary UHPLC System |
| Price Range | USD 65,000 – 130,000 |
| Instrument Type | Ultra-High Performance Liquid Chromatograph (UHPLC) |
| Maximum Pressure | 1000 bar (15,000 psi) |
| Flow Rate Range | 0.001–8.0 mL/min |
| Solvent Channels | 6 |
| Injector Capacity | 208 injections (single vial) |
| Column Oven Temperature Range | 5–120°C (dual-mode: static air + forced-air circulation) |
| Detection Options | Diode Array (DAD), Fluorescence (FLR), Electrospray Ionization (ESI) Charged Aerosol Detection (CAD), and MS-coupling ready |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Category | Imported Laboratory Instrument |
| Model | ICS-4000 QD |
| Pump Pressure Rating | 6000 psi |
| Flow Rate Range | 0.001–0.100 mL/min |
| Eluent Flow Rate | 0.001–0.100 mL/min |
| Maximum Operating Pressure | 6000 psi |
| Operating Temperature Range | 10–40 °C |
| Temperature Reproducibility | ±0.2 °C |
| Eluent Concentration Range | 0.1–200 mM |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | ICS-2100 |
| Instrument Type | Laboratory Benchtop System |
| Maximum Pump Pressure | 6000 psi |
| Operating Pressure Range | Up to 5000 psi |
| Column Oven Temperature Range | 4–40 °C |
| Eluent Concentration Range | 0–100 mM KOH (varies with eluent chemistry) |
| Detection Principle | Suppressed Conductivity Detection with Electrolytic Eluent Generation and Electrolytic Sample Preparation |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | Prelude SPLC |
| Instrument Type | Conventional High-Performance Liquid Chromatography (HPLC) System |
| Price Range | USD 68,000 – 136,000 (based on configuration and regional duties) |
| Wavelength Range | Not Applicable |
| Data Acquisition Frequency | Not Applicable |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | U3000 Rapid Separation Quaternary System |
| Instrument Type | Rapid Liquid Chromatograph |
| Maximum Flow Rate | 8 mL/min |
| Maximum Backpressure | 100 MPa (15000 psi / 1000 bar) |
| Column Temperature Range | 5–110 °C |
| Gradient Delay Volume | Adjustable via SpinFlow™ Technology |
| Autosampler Carryover | < 0.001% |
| Detector Compatibility | UV-Vis (DAD, MWD, VWD), FLR, CAD, RID, MS |
| Brand | Thermo Fisher |
|---|---|
| Origin | Mexico |
| Manufacturer | Thermo Fisher Scientific |
| Origin Category | Imported |
| Model | Aquion RFIC |
| Instrument Type | Laboratory |
| Maximum Pump Pressure | 5000 psi |
| Flow Rate Range | 0.00–5.00 mL/min |
| Eluent Flow Rate Range | 0.00–5.00 mL/min |
| Maximum Operating Pressure | 5000 psi |
| Operating Temperature Range | Ambient +5°C to 60°C |
| Temperature Reproducibility | ±0.05°C |
| Eluent Concentration Range | 0.1–100 mM |
| Brand | Thermo Fisher |
|---|---|
| Origin | Italy |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | TRACE 1300 |
| Instrument Type | Laboratory Gas Chromatograph |
| Application Scope | General-Purpose |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | UltiMate3000 |
| Price Range | USD 42,000 – 56,000 (FOB) |
| Application Level | Laboratory-Scale |
| Instrument Type | Medium-to-Low Pressure Preparative LC |
| Maximum Operating Pressure | 620 bar |
| Data Acquisition Rate | 100 Hz |
| Maximum Flow Rate | 10 mL/min |
| Pump Configuration Options | 7 single-pump and 5 dual-pump modular combinations |
| Dimensionality Support | 1D, 2D, and multi-dimensional LC workflows |
| Brand | Thermo Fisher |
|---|---|
| Model | Ultimate |
| Type | Nano-LC / Capillary LC System |
| Flow Range | 50 nL/min – 10 µL/min |
| Column Compatibility | 50–360 µm ID capillary & nano columns |
| Detection Interface | ESI-MS, nano-ESI source compatible |
| Regulatory Compliance | GLP-ready architecture, 21 CFR Part 11–ready software options |
| Pump Technology | Dual high-precision micro-piston pumps with active solvent compressibility compensation |
| Injector | FAMOS autosampler with <100 nL injection precision |
| UV Detection | Scanning diode array detector (DAD), optional nano-flow UV cell (Z- or U-path, 10–50 nL volume) |
| Temperature Control | Optional thermostatted column compartment (4–80 °C) |
| Software Platform | Chromeleon CDS (Chromatography Data System), supporting audit trail, electronic signatures, and method validation workflows |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Import Status | Imported |
| Model | UltiMate 3000 Basic Manual System |
| Instrument Type | Conventional High-Performance Liquid Chromatograph (HPLC) |
| Maximum Flow Rate | 10 mL/min |
| Maximum Backpressure | 62 MPa (9000 psi / 620 bar) |
| Integrated Degasser | 4-channel solvent degasser (LPG-3400SD) |
| Detection Compatibility | UV-Vis (DAD, MWD, VWD), Fluorescence, CAD, RID, MS |
| Software Platform | Chromeleon CDS v6.x and v7.x (including eWorkflow, audit trail, 21 CFR Part 11 compliance support) |
| Column Oven | TCC-3000SD (thermostatically controlled, field-upgradeable with up to two column switching valves) |
| Injection Options | Manual or motorized injection valve with contact-closure triggering |
| Fluidic Interface | Dionex Viper fingertight fittings (near-zero dead volume) |
| Flow Control Technology | Dionex SmartFlow for <±0.1% flow accuracy and retention time stability |
| Brand | Thermo Fisher |
|---|---|
| Origin | Germany |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Origin Category | Imported |
| Model | Vanquish Neo UHPLC |
| Instrument Type | Ultra-High-Performance Liquid Chromatograph |
| Application Scope | General-Purpose LC-MS Platform |
| Flow Rate Range | 100 nL/min–100 µL/min |
| Maximum Operating Pressure | 150 MPa |
| Flow Precision | ≤0.2% RSD or ≤0.1 µL/min SD (whichever is greater), validated per IQ protocol using Cytochrome C tryptic digest peptides (TGQAPGFSYTDANK) |
| Injection Volume Range | 100 nL–100 µL |
Show next