Used Instruments
Filter
Showing 31–60 of 79 results
| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Instrument Category | Imported |
| Model | GE AKTA Explorer 100 |
| Operational Age | >10 years |
| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Import Status | Imported |
| Model | GE AKTA Explorer 100 Biological Purification System |
| Operational Age | >10 years |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Operating Temperature | 4–35 °C |
| Relative Humidity | 20–95% (non-condensing) |
| Power Consumption | 1100 W (instrument: 800 W, PC: 300 W) |
| UV Detection Range | –6 to +6 AU |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| Temperature Sensor Range | 0–99 °C (±1.5 °C accuracy, 4–45 °C) |
| pH Sensor Range | 0–14 pH (±0.1 pH accuracy, pH 2–12) |
| Fraction Collector Volume Range | 0.1–50 mL |
| Integrated Pressure Sensors | System pump, sample pump, column inlet, column outlet |
| Integrated Air Bubble Detectors | Sample inlet, Pump A, Pump B |
| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | GE AKTA Explorer 100 Protein Purification System |
| Price Range | USD $10,500 – $15,800 (FOB) |
| Operational Age | >10 years |
| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | GE AKTA Explorer |
| Operational Age | >10 Years |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Operating Temperature | 4–35 °C |
| Relative Humidity | 20–95% (non-condensing) |
| Power Consumption | 1100 W (Instrument: 800 W |
| PC | 300 W) |
| UV Detection Range | −6 to +6 AU |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| Temperature Sensor Range | 0–99 °C (±1.5 °C accuracy, 4–45 °C) |
| pH Sensor Range | 0–14 pH (±0.1 pH accuracy, pH 2–12) |
| Fraction Collector Volume Range | 0.1–50 mL |
| Integrated Pressure Sensors | System pump, sample pump, column inlet, column outlet |
| Integrated Air Bubble Detectors | Sample inlet, Pump A, Pump B |
| Brand | Baker Hughes (formerly GE Healthcare) |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Product Category | Imported Instrument |
| Model | AKTA Explorer 100 |
| Operational Age | >10 Years |
| Dimensions (L×W×H) | 860 × 710 × 660 mm |
| Weight | 116 kg |
| Operating Temperature | 4–35 °C |
| Relative Humidity | 20–95% RH (non-condensing) |
| Power Consumption | 1100 W (system: 800 W, PC: 300 W) |
| UV Detection Range | –6 to +6 AU |
| Conductivity Accuracy | ±0.01 mS/cm or ±2% |
| Temperature Sensor Range | 0–99 °C (±1.5 °C accuracy, 4–45 °C range) |
| pH Sensor Range | 0–14 pH units (±0.1 pH accuracy, pH 2–12 range) |
| Fraction Collector Volume Range | 0.1–50 mL |
| Integrated Pressure Sensors | System pump, sample pump, column inlet, column outlet |
| Integrated Air Bubble Detectors | Sample inlet, Pump A, Pump B |
| Brand | Hitachi High-Technologies |
|---|---|
| Origin | Japan |
| Model | S-3400N |
| Operating Age | ~10 years |
| Vacuum System | Turbo-molecular pump |
| SE Resolution | 3.0 nm @ 30 kV (high vacuum), 10 nm @ 3 kV (high vacuum) |
| BSE Resolution | 4.0 nm @ 30 kV (low vacuum) |
| Accelerating Voltage | 0.3–30 kV |
| Magnification | ×5 to ×300,000 |
| Max Sample Diameter | 200 mm |
| Stage Types | Manual (Type I) and Motorized 5-Axis (Type II) |
| Stage Travel (Type II) | X 0–100 mm, Y 0–50 mm, Z 5–65 mm, R 360°, T –20° to +90° |
| Max Sample Height | 80 mm (WD = 10 mm) |
| Detector Configuration | High-sensitivity semiconductor BSE detector (5-segment), Everhart-Thornley SE detector |
| Analytical Compatibility | Simultaneous EDX, WDX, and EBSD integration supported |
| Beam Control | Auto filament saturation, auto gun alignment, auto stigmation, auto focus, auto brightness/contrast, manual & automatic beam current adjustment, fixed-ratio & manual & auto 4-quadrant biasing |
| Aperture | Movable 4-position objective aperture |
| Brand | Hitachi High-Technologies |
|---|---|
| Origin | Japan |
| Manufacturer Type | Authorized Distributor |
| Category | Imported Instrument |
| Model | HITACHI SU-3500 |
| Price | USD 62,500 (FOB Yokohama) |
| Operational Age | 5 years |
| Secondary Electron Resolution | 3 nm @ 30 kV, 7.0 nm @ 3 kV |
| Backscattered Electron Resolution | 4.0 nm @ 30 kV, 10.0 nm @ 5 kV |
| Magnification Range | 5× to 300,000× (typical working range: 20×–50,000× for standard bulk samples) |
| Accelerating Voltage | 0.3–30 kV |
| Detector Configuration | In-lens SE detector, Everhart-Thornley SE detector, solid-state BSE detector |
| Brand | INNOTEG |
|---|---|
| Model | GC-5000C |
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Price Range | USD 14,000 – 28,000 (FOB) |
| Column Oven Temperature Range | Ambient + 5°C to 450°C |
| Max Ramp Rate | 150°C/min |
| Temperature Control Zones | 5 Standard + 4 Optional |
| Display | 9-inch Full-Color Touchscreen |
| Injector Configurations | Up to 3 Inlet Ports (simultaneous dual-injection capable) |
| Carrier Gas Control | Electronic Flow Control (EFC) |
| Compliance | Designed to meet ISO/IEC 17025 laboratory requirements for chromatographic analysis |
| Brand | INNOTEG |
|---|---|
| Model | HP-HG250 |
| Origin | Guangdong, China |
| Output Flow Rate | 250 mL/min |
| Hydrogen Purity | ≥99.9996% |
| Technology | Proton Exchange Membrane (PEM) Electrolysis |
| Water Feed | Deionized Water (Resistivity ≥1 MΩ·cm) |
| Maintenance | Maintenance-Free Drying System |
| Safety Features | Internal/External H₂ Leak Detection, Overpressure Protection, Overtemperature Protection, Real-Time Water Level Monitoring, Conductivity-Based Water Quality Monitoring |
| Compliance Context | Designed for GLP-compliant GC labs |
| Brand | AB |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Ion Proton Sequencer |
| Quoted Price | USD 1,450 (FOB) |
| Operational Age | ≥5 Years |
| Configuration | Includes Integrated Ion Chef System |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JSM-7001F |
| Vacuum Mode | High Vacuum / Low Vacuum (up to 50 Pa) |
| Resolution | 3.0 nm @ 30 kV (Backscattered Electron Imaging) |
| Sample Chamber Diameter | Up to 200 mm |
| Stage | Motorized 5-axis (X, Y, Z, Tilt, Rotation) |
| Detector Compatibility | EDS, WDS, EBSD, CL, SE, BEI |
| Operating System | Windows XP (original factory configuration) |
| Gun Chamber Pressure | ≤5 × 10⁻⁷ Pa |
| Recommended Gas for LV Mode | Dry Nitrogen |
| Instrument Age | ~10 years |
| Condition | Refurbished & Functionally Verified |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JSM-7610FPLUS |
| Year of Manufacture | 2017 |
| Operational Age | 5 years |
| Vacuum System | Turbo-molecular + Ion Pump |
| Max Magnification | 1,000,000× |
| Resolution (SE) | 0.8 nm @ 15 kV, 1.0 nm @ 1 kV |
| Acceleration Voltage | 100 V – 30 kV |
| Electron Source | Schottky Thermal Field-Emission Gun |
| Beam Current | Up to 200 nA |
| Working Distance | 8 mm |
| Stage | 5-axis Motorized, ±5° to +70° tilt, 360° rotation |
| EDS Detector Area | ≥20 mm², Be–Am detection range, Mn-Kα resolution ≤127 eV |
| EBSD Compatibility | Yes |
| Compliance | ASTM E1558, ISO 16700, IEC 61000-4-5 (EMC), GLP-ready data logging |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JSM-IT100 |
| Vacuum Modes | High Vacuum & Low Vacuum (10–300 Pa) |
| Resolution | 3 nm @ 30 kV (HV), 4 nm @ 30 kV (LV) |
| Acceleration Voltage | 0.5–30 kV (optional extension to 30 kV) |
| Magnification | ×5 to ×300,000 |
| Stage Travel | X 80 mm, Y 40 mm, Z 5–48 mm, Tilt −10° to +90°, Rotation 360° |
| Max Sample Diameter | 150 mm |
| EDS Functions | Point analysis, elemental mapping, line scan, real-time filtering |
| Detector Options | Dry SD (10/30/60/100 mm² active area) |
| Software | InTouchScope™ GUI with integrated SEM/EDS workflow |
| Power Requirement | 100 V AC, no cooling water required |
| Footprint | ~30% smaller than prior JEOL benchtop SEMs |
| Operational Age | 2 years |
| Compliance | Designed per JEOL’s internal quality system aligned with ISO 9001 |
| Brand | JEOL |
|---|---|
| Origin | Japan |
| Model | JSM-IT200 |
| Instrument Age | 2 years |
| Configuration | Standard SEM + EDS (Energy Dispersive X-ray Spectroscopy) |
| Vacuum Mode | High Vacuum & Low Vacuum (LA) compatible |
| Sample Stage | Motorized Tilt/Rotation/XYZ |
| CCD Navigation Camera | 5 MP, 6 × 4.5 cm FOV, Digital Zoom up to ×20 |
| Software Platform | SMILE VIEW™ Lab |
| Compliance | Fully serviceable per JEOL OEM maintenance protocols |
| Brand | OtO |
|---|---|
| Origin | Taiwan |
| Model | SW2860-050 |
| Wavelength Range | 900–1700 nm |
| Detector | 256-pixel InGaAs linear array |
| Cooling | Thermoelectric (TE) |
| Usage Duration | 2 years |
| Warranty | ≥3 years |
| Condition | Refurbished, Fully Tested |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | ARVO X3 |
| Condition | Factory-Refurbished |
| Configuration | Complete System with Onboard Software, Filter Wheels, and Standard Optical Modules |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Lambda 2 |
| Product Category | Spectroscopy |
| Instrument Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Complete system, fully tested and calibrated |
| Compliance | Meets original factory specifications for optical performance and photometric accuracy |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | NexION 300Q |
| Instrument Type | Inductively Coupled Plasma Mass Spectrometer (ICP-MS) |
| Operational Age | 4 years |
| Warranty | 6 months |
| Compliance | Fully refurbished and performance-verified per ASTM D5673 and ISO/IEC 17025-aligned protocols |
| Software | Syngistix v3.5 or later (FDA 21 CFR Part 11 compliant configuration available) |
| Detection Limit Performance | Sub-femtogram-level sensitivity for key isotopes (e.g., ⁹Be, ¹¹⁵In, ²⁰⁸Pb) under optimized conditions |
| Vacuum System | Dual-stage turbomolecular pumping with integrated cryo-trapping capability |
| Ion Optics | Triple-cone interface + three quadrupole mass filters (Q1: ion/molecule separation |
| Q2 | universal cell reaction/collision zone |
| Q3 | high-resolution mass filtering) |
| Brand | PerkinElmer |
|---|---|
| Origin | USA |
| Model | Spectrum ONE |
| Instrument Type | Fourier Transform Infrared (FTIR) Spectrometer |
| Age | 3–4 years |
| Warranty | 6 months |
| Configuration | Includes Spectrum ONE main unit, Spectrum Spotlight FTIR Imaging System, and dedicated PC with proprietary software |
| Compliance | Fully refurbished and performance-verified per ASTM E1421–22 standard for FTIR instrument qualification |
| Software | Spectrum v6.x (with full license transfer eligibility) |
| Detector | Dual-channel DTGS/KBr beam splitter configuration |
| Spectral Range | 4000–400 cm⁻¹ (standard) |
| Resolution | Adjustable down to 0.5 cm⁻¹ |
| Scan Speed | Up to 20 kHz mirror velocity |
| Data Format | Compatible with JCAMP-DX, ASCII, and HDF5 export |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | ADS |
| Configuration | 12-Position Auto-Sampler with Peristaltic Pump & UV-Vis Spectrophotometer Integration |
| Software | Win DISS 32 (21 CFR Part 11 Compliant) |
| UV Cell Options | 8- or 16-cell carousel, pathlengths 0.1–20 mm |
| Pump Type | IPC8/IPC16 Multi-Channel Peristaltic Pump |
| Regulatory Alignment | ASTM USP <711>, EP 2.9.3, JP 17, FDA Guidance for Industry |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | DFC1220SP |
| Configuration | Offline semi-automatic dissolution system with fraction collector and in-situ or EPE-1220 sampling |
| Compliance | USP <711>, USP <724>, Ph. Eur. 2.9.3 & 2.9.4 |
| Stirring Stations | 8 |
| Sampling Method | Programmable timed aspiration via dual PT-SP8 syringe pumps or optional Ismatec peristaltic/CAT piston pumps |
| Temperature Monitoring | Optional ITM-1220 in-line probe |
| Media Replacement | Automated media replenishment capability |
| Tablet Drop Test | Compatible with TM-1220/TMA-1220 tablet drop modules |
| Reporting | PT-RP80 thermal printer support |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTWS 1220 |
| Configuration | 12-position, single-drive, paddle/basket dissolution apparatus |
| Compliance | USP <711>, USP <724>, EP 2.9.3 & 2.9.4, JP <15>, ChP |
| Temperature Control Range | 37.0 ± 0.2 °C (typical operational stability) |
| Sampling Capability | Automated timing with optical/acoustic alerts |
| Data Storage | SD card (FAT32 formatted, up to 32 GB) |
| User Management | Role-based access control (admin/operator) |
| Instrument Status Indication | Tri-color LED traffic-light display (green/yellow/red) |
| Calibration Support | Integrated self-test at power-on |
| Brand | Pharma-test |
|---|---|
| Origin | USA |
| Model | PTWS 1420 |
| Configuration | Dual-motor independent paddle/stirrer control |
| Test Stations | 14 dissolution vessels + 2 auxiliary heating/medium reservoir vessels |
| Compliance | USP <711>, <724>, EP 2.9.3 & 2.9.4, BP, DAB, JP 15 |
| Temperature Monitoring | Individual cup-level ITM sensors |
| Automated Sampling | EPE robotic arm with precise Z-axis immersion and positioning |
| Dosing | TMA automatic tablet/capsule drop module |
| Drive System | Monoshaft™ single-shaft universal adapter for USP Apparatus 1 (basket), 2 (paddle), 5 (paddle-over-disk), and 6 (cylinder) |
| Method Storage | Unlimited protocols via SD card |
| Calibration & Qualification | Built-in OQ/PQ reminder, pre-run self-diagnostic (optical + audible feedback) |
| Fluid Handling | DSR-M 13-channel piston pump with LCD display, 20-sample capacity, HPLC vial/tube rack compatibility |
| Thermal System | 1500 W rapid-heating water bath with removable tank, diffuser-assisted uniformity, low-volatility vessel lids |
| Connectivity | USB remote control, RS232 printer interface |
| Acoustic Design | Low-noise, vibration-damped recirculating pump |
| Software Features | User management, method management, stepwise manual start, audit-ready event logging |
| Brand | Pharma-test |
|---|---|
| Origin | USA |
| Model | PTWS 1420 |
| Configuration | Dual-drive, 14-vessel dissolution system with independent paddle/stirrer speed control per side |
| Compliance | Fully compliant with USP <711>, <724>, EP <2.9.3>, <2.9.4>, BP, DAB, and JP <15> |
| Vessel capacity | 14 test positions + 2 auxiliary temperature-controlled media reservoirs |
| Temperature monitoring | Individual cup-level ITM sensors (±0.2 °C accuracy) |
| Automated dosing | TMA tablet drop module |
| Sampling system | EPE robotic autosampler with precise XYZ positioning and immersion depth control |
| Drive architecture | Monoshaft™ single-shaft design for seamless USP Apparatus 1 (basket), 2 (paddle), 5 (paddle-over-disk), and 6 (cylinder) interchangeability without re-heighting |
| Method storage | Unlimited methods via SD card with user-accessible encryption and audit trail metadata |
| Pump system | DSR-M 13-channel piston pump with LCD interface, 20-sample programmable sequence, compatible with standard HPLC vials and tube racks (2–20 mL) |
| Water bath | 1500 W rapid-heating stainless-steel bath with detachable design, integrated diffuser for ±0.1 °C thermal uniformity across all vessels |
| Acoustic & vibration performance | Low-noise circulation pump with anti-vibration mounting |
| Pre-run diagnostics | Integrated self-test with visual LED indicators and audible status tones |
| Qualification support | Built-in OQ/PQ checklist prompts and timestamped event logging |
| Connectivity | USB host for PC remote operation |
| Safety & ergonomics | Low-volatility vessel lids, step-start manual mode, dual-motor left/right independent drive control |
| Software compliance | Audit-trail-enabled method execution logs meeting FDA 21 CFR Part 11 requirements for electronic records and signatures |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Model | PTWS 610 |
| Configuration | 8-position, single-drive dissolution apparatus |
| Regulatory Compliance | USP <711>, USP <724>, Ph. Eur. 2.9.3 & 2.9.4, JP <15>, ChP |
| Temperature Control Range | 37.0 ± 0.2 °C (typical operating condition) |
| Sampling Mechanism | Automated timed sampling with optical/audible alerts |
| Data Storage | SD card (user-replaceable, FAT32 formatted) |
| User Access Control | Role-based login (administrator, operator, reviewer) |
| System Diagnostics | Power-on self-test (POST), real-time status monitoring via tri-color LED indicator |
| Calibration & Qualification Support | Built-in OQ/PQ reminder logic, audit-ready event logging |
| Brand | Pharma-test |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | PTWS 820D |
| Price | USD 33,500 (FOB Hamburg, ex-works condition) |
| Origin | Germany |
|---|---|
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | EDM 5000 |
| Price | USD 8,400 (excl. VAT, FOB terms available) |
| Brand | SCIEX |
|---|---|
| Origin | USA |
| Instrument Type | Hybrid Triple Quadrupole / Linear Ion Trap Mass Spectrometer |
| Model | QTRAP 4000 |
| Application Domain | LC-MS/MS Quantitation & Structural Characterization |
| Operational Age | 3–4 years in active service |
| Total Service Life | ~7 years |
| Warranty | 6 months limited hardware warranty |
| Regulatory Compliance | Designed to support GLP/GMP workflows, 21 CFR Part 11–ready software environment (with optional audit trail configuration) |
| Sample Introduction | Compatible with multiple HPLC/UHPLC platforms (Agilent, Shimadzu, Waters, Thermo) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-QP2010 Plus |
| Mass Range | m/z 10–1090 |
| Scan Speed | 10,000 amu/sec |
| Vacuum System | Dual-inlet turbo molecular pump (≥360 L/s) |
| Ion Source | Shielded design with uniform temperature distribution |
| Detection Mode | Scan/SIM simultaneous acquisition via FASST |
| Mass Analyzer | Molybdenum quadrupole with pre-rod |
| Retention Time Correction | AART (Automatic Adjustment of Retention Time) |
| Software | Compound Composer, Method Package, EPA-compliant modules, GPC-GC/MS integration capability (Prep-Q system) |
| Warranty | 1 year |
| Instrument Age | 3–5 years |
| Compliance | Designed for GLP/GMP environments |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GCMS-TQ8050 |
| Year of Manufacture | 2018 |
| Condition | Refurbished & Certified Pre-Owned |
| Configuration | Complete Benchtop System with GC, TQMS, Autosampler, and GCMS Insight Software |