| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 6890N |
| Detector Options | FID (detection limit <5 pg C/s on propane), TCD, ECD, NPD, FPD, FTD |
| Oven Temperature Range | +4 °C above ambient to 450 °C |
| Inlet Pressure Range | 0–100 psi (optional 0–150 psi) |
| Carrier Gas Flow Range | 0–200 mL/min (N₂), 0–1000 mL/min (H₂ or He) |
| Integrated Control | Agilent 7683 Autoinjector |
| Compliance | ASTM D3606, D5503, ISO 10301, USP <621>, FDA 21 CFR Part 11 ready (with ChemStation Plus configuration) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Agilent 6890N (Refurbished) |
| Price Range | USD 4,200 – 11,200 |
| Detector | FID (Detection Limit: <5 pg C/s on propane) |
| Oven Temperature Range | Ambient +4 °C to 450 °C |
| Split/Splitless Injector Pressure Range | 0–100 psi (optional 0–150 psi) |
| Total Flow Range (Split/Splitless) | 0–200 mL/min N₂, 0–1000 mL/min H₂ or He |
| Autosampler | Integrated Agilent 7683 Control |
| GC Speed | Up to 10× faster than conventional GC |
| Compliance | Designed for ASTM D3606, D5186, ISO 6416, USP <621>, FDA 21 CFR Part 11-ready configurations available |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7820A |
| Dimensions (H×W×D) | 49 × 56 × 51 cm |
| Weight | 50 kg |
| Column Oven Temp Range | 8 °C above ambient to 425 °C |
| Max Ramp Rate | 75 °C/min |
| Temperature Stability | < 0.01 °C per 1 °C ambient change |
| Retention Time Reproducibility | < 0.06% RSD |
| Peak Area Reproducibility | < 2% RSD |
| EPC Pressure Control Accuracy | ±0.01 psi |
| FID MDL | < 3 pg C/s (tridecane) |
| TCD MDL | < 800 pg propane/mL (He carrier) |
| NPD MDL | < 0.4 pg N/s, < 0.2 pg P/s (azobenzene/mixture) |
| ECD MDL | < 0.02 pg/mL (lindane) |
| Operating Environment | 15–30 °C, 30–70% RH |
| Safety Compliance | UL 61010, CSA C22.2 No. 61010, IEC 61010, EN 61010 |
| EMC Compliance | CISPR 11 / EN 55011 Class A, IEC/EN 61326 |
| Quality System | ISO 9001 certified |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7820A |
| Condition | Refurbished & Certified Pre-Owned |
| Compliance | Fully Tested to Original Agilent Specifications |
| Software | Includes OpenLab CDS Basic (License Transferable per Agilent Policy) |
| Detector Options Supported | FID, TCD, ECD, NPD, FPD |
| Column Compatibility | Up to 2 x 30 m capillary columns or packed columns |
| Carrier Gas | Helium, Hydrogen, Nitrogen (with optional electronic pressure control) |
| Temperature Range | Oven: 35–450 °C |
| Injector | 50–450 °C |
| Detector | 50–450 °C |
| Data System | PC-based with USB/Ethernet connectivity |
| Regulatory Readiness | Supports 21 CFR Part 11-compliant audit trails when deployed with validated OpenLab CDS configuration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A |
| Detector Options | FID, TCD, NPD, PFPD, XSD |
| Inlet Options | SSL, PPIP, MMI, COC, COC-SVE, PTV, VI, GSV, LSV |
| Software | EZChrom Elite Compact, OpenLAB CDS |
| Warranty | 90 days |
| Certification | Factory-refurbished and performance-verified by SpectraLab Scientific |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890A |
| Configuration | Dual Inlet / Triple Detector (incl. TCD) |
| EPC Channels | Up to 16 |
| Temperature Range | –80 °C to 450 °C (with LN₂ cooling) |
| Retention Time Reproducibility | < 0.008% RSD |
| Peak Area Reproducibility | < 1% RSD |
| Column Oven Dimensions | 28 × 31 × 16 cm |
| Max Ramp Rate | 120 °C/min |
| Cooling from 450 °C to 50 °C | 4.0 min (standard), 3.5 min (with insert) |
| Pressure Control Precision | ±0.001 psi (0–99.999 psi range) |
| Data Acquisition Rate | Up to 500 Hz (FID) |
| Supported Detectors | FID, TCD, Micro-ECD, NPD, FPD, SCD, NCD, MSD (via interface) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | GC 7890A |
| Condition | Refurbished & Certified Pre-Owned |
| Compliance | Fully Tested to Original Agilent Specifications |
| Software | Compatible with OpenLab CDS (Legacy ChemStation Support Available) |
| Detector Options | FID, TCD, ECD, NPD, PID (Configurable per Unit) |
| Column Compatibility | Standard 1/4" and 0.53 mm ID Capillary Columns |
| Carrier Gas | Helium, Hydrogen, or Nitrogen (with Electronic Pressure Control) |
| Temperature Range | Oven: -10 °C to 450 °C (with LN2 cooling option available) |
| Injector | Up to 450 °C |
| Detector | Up to 450 °C |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Operational Age | 4–5 years |
| Configuration | Standard GC system with integrated 7683 autosampler control |
| Regulatory Readiness | Built-in 21 CFR Part 11 compliance features (audit trail, electronic signature support, user access levels) |
| Detection Options | FID, TCD, µECD, NPD, MSD, ICP-MS, and optional PFPD, SCD, AED via Agilent partner ecosystem |
| Injection Modes | Split/splitless (0–100 psi & 0–150 psi), packed column, on-column, PTV, and volatile analysis interface |
| Data Systems | Compatible with Agilent ChemStation Plus (ChemStore C/S, ChemAccess), PetroQA/QC Cerity NDS |
| Speed Capability | Fast GC mode (up to 10× faster than conventional GC) |
| Sample Introduction | Supports headspace, purge-and-trap, valve injection, and large-volume injection (LVI) without pre-concentration |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | Agilent 7890A |
| Instrument Age | 4–5 years |
| Configuration | Includes integrated Agilent 7683 autosampler control |
| Detector Options | FID, TCD, µECD, NPD, MSD, ICP-MS, FPD (upgraded), plus optional SCD, PFPD, AED via Agilent Partners |
| Inlet Types | Split/splitless (0–100 psi & 0–150 psi), packed column, on-column, PTV, VOA |
| Software Compatibility | Agilent ChemStation Plus (ChemStore C/S, ChemAccess), Cerity QA/QC for Petrochemicals |
| Regulatory Compliance | Supports 21 CFR Part 11 audit trails, GLP/GMP data integrity requirements |
| GC Speed | Capable of fast GC operation (up to 10× faster than conventional GC) |
| Sample Introduction | Large-volume injection (LVI) enabled, headspace, purge-and-trap, valve-based injection modules available |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B |
| Configuration | GC Mainframe with S/SL Inlet, FID Detector, 80-PAL Autosampler |
| Warranty | 90-day comprehensive hardware warranty |
| Certification | Fully tested and validated per Agilent-recommended performance verification protocols |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | 7890B |
| Carrier Gas Options | Helium, Hydrogen, Nitrogen |
| Column Oven Temperature Range | 0–450 °C |
| Maximum Ramp Rate | 120 °C/min |
| Detector Compatibility | FID, TCD, ECD, NPD, FPD, MSD (with appropriate interface) |
| Software Platform | OpenLab CDS (ChemStation-compatible mode available) |
| Compliance | ASTM D3606, D5186, ISO 10301, USP <621>, FDA 21 CFR Part 11 (when configured with audit trail & electronic signature) |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Manufacturer | Agilent Technologies |
| Instrument Type | Imported Used GC |
| Model | 6890N |
| Warranty | 12 months |
| Service Coverage | Global Agilent Field Service Network |
| Software Compatibility | Fully compatible with OpenLab CDS (v2.3+), ChemStation (Rev. E.02.02.1400+) |
| Regulatory Compliance | Designed to support GLP/GMP environments |
| Firmware | Updated to latest certified revision at time of refurbishment |
| Physical Condition | New chassis, refurbished internal modules, factory-cleaned flow paths, recalibrated detectors and injectors |
| Brand | Agilent Technologies |
|---|---|
| Origin | USA |
| Model | GC6890 |
| Condition | Refurbished & Fully Qualified |
| Compliance | Meets ASTM D3606, ISO 17025-relevant operational standards |
| Detector Options Supported | FID, TCD, ECD, NPD, FPD |
| Column Compatibility | Up to 0.53 mm ID capillary or packed columns |
| Oven Temperature Range | 4°C to 450°C (programmable) |
| Injector Types | Split/Splitless, Cool-on-Column, PTV |
| Data System | Compatible with Agilent ChemStation (Rev. A.10.x or later) |
| Regulatory Readiness | Audit-trail capable |
| Brand | INNOTEG |
|---|---|
| Model | GC-5000C |
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Country of Manufacture | China |
| Price Range | USD 14,000 – 28,000 (FOB) |
| Column Oven Temperature Range | Ambient + 5°C to 450°C |
| Max Ramp Rate | 150°C/min |
| Temperature Control Zones | 5 Standard + 4 Optional |
| Display | 9-inch Full-Color Touchscreen |
| Injector Configurations | Up to 3 Inlet Ports (simultaneous dual-injection capable) |
| Carrier Gas Control | Electronic Flow Control (EFC) |
| Compliance | Designed to meet ISO/IEC 17025 laboratory requirements for chromatographic analysis |
| Brand | INNOTEG |
|---|---|
| Model | HP-HG250 |
| Origin | Guangdong, China |
| Output Flow Rate | 250 mL/min |
| Hydrogen Purity | ≥99.9996% |
| Technology | Proton Exchange Membrane (PEM) Electrolysis |
| Water Feed | Deionized Water (Resistivity ≥1 MΩ·cm) |
| Maintenance | Maintenance-Free Drying System |
| Safety Features | Internal/External H₂ Leak Detection, Overpressure Protection, Overtemperature Protection, Real-Time Water Level Monitoring, Conductivity-Based Water Quality Monitoring |
| Compliance Context | Designed for GLP-compliant GC labs |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2010A (Red-Black Label) |
| Category | Imported Used Analytical Instrument |
| Distribution Type | Authorized Distributor |
| Price Range | USD 6,800 – 19,000 (FOB Asia) |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2010Plus |
| Configuration | Multi-detector, Dual Autosampler (AOC-20i ×2 + AOC-20s) |
| Column Oven Temp Range | Ambient +4°C to 450°C (down to –50°C with liquid CO₂ cooling option) |
| Cooling Rate | 450°C → 50°C in ≈3.4 min |
| Detector Options | FID (1.5 pgC/s), ECD (6 fg/s), FPD (P: 55 fgP/s |
| S | 3 pgS/s), TCD, FTD/NPD |
| AFC Pressure Control | 0–970 kPa, 7-segment programming |
| Max Simultaneous Detectors | 4 |
| Max Simultaneous Inlet Units | 3 |
| Display | 240 × 320 dot graphic LCD |
| Brand | Shimadzu |
|---|---|
| Origin | Japan |
| Model | GC-2014A |
| Column Oven Temp Range | Ambient +10 °C to 420 °C (–50 °C to 420 °C with liquid CO₂ cooling) |
| Injector Temp Range | Up to 420 °C |
| Detector Temp Range | Up to 420 °C (FID/TCD/FTD), up to 400 °C (ECD/FPD) |
| Max Simultaneous Inlets | 3 |
| Max Simultaneous Detectors | 4 |
| Programmed Temperature Ramping | 20-step, –250 to +250 °C/min |
| Pressure Control | Digital AFC (0–970 kPa, ramp rate –400 to +400 kPa/min) |
| Display | 240 × 320-pixel graphical LCD |
| Dimensions (W×H×D) | 607 × 690 × 400 mm |
| Weight | 48 kg (GC-2014AF configuration) |
| Power Supply | AC 200 V, 1800 VA, 50/60 Hz |