Used Instruments
Filter
Showing 61–79 of 79 results
| Brand | Skalar |
|---|---|
| Origin | Netherlands |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SAN++ |
| Price | USD 70,000 (FOB Rotterdam) |
| Operational Age | 6 years |
| Throughput | Up to 800 samples/day |
| Simultaneous Parameters | Up to 16 per sample |
| Compliance | ASTM, ISO, EPA, CEN, DIN, ASBC, EBC, CORESTA, USP, FDA 21 CFR Part 11 |
| Brand | TA Instruments |
|---|---|
| Origin | USA |
| Model | DSC-25 |
| Temperature Range | –180 °C to 725 °C |
| Baseline Flatness (–50 °C to 300 °C) | ≤100 µW |
| Baseline Repeatability (–50 °C to 300 °C) | <40 µW |
| Temperature Accuracy | ±0.1 °C |
| Temperature Precision | ±0.01 °C |
| Enthalpy Accuracy | ±0.1% |
| Operational Age | 2 years |
| Condition | Fully Functional |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | iCAP 6000 |
| Optical System | Echelle grating with cross-disperser |
| Spectral Range | 166–847 nm |
| Resolution | High spectral resolution for trace analysis in complex matrices |
| Detector | High-sensitivity CCD |
| RF Generator | 27.12 MHz solid-state |
| Power Range | 750–1500 W (adjustable) |
| Cooling | Air or water cooling |
| Nebulizer | Concentric or optional ultrasonic |
| Spray Chamber | Chemically resistant (e.g., PTFE) |
| Peristaltic Pump | 4-channel, flow-rate adjustable |
| Sample Throughput | As low as 30 s per sample |
| Detection Limits | Sub-ppb (element-dependent) |
| Linear Dynamic Range | 6–7 orders of magnitude |
| Precision | RSD < 2% |
| Software | Thermo Scientific iTEVA |
| Compliance | 21 CFR Part 11 ready |
| Dimensions | ~700 × 650 × 600 mm |
| Weight | ~80 kg |
| Power Supply | 200–240 V, 50/60 Hz |
| Operating Environment | 15–30 °C, <80% RH (non-condensing) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Orbitrap Fusion Lumos |
| Pricing | Upon Request |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Thermo Orbitrap Fusion Tribrid High-Resolution Mass Spectrometer |
| Price | Upon Request |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | Dionex ICS-6000 |
| Operating Pressure | Up to 5000 psi (34.5 MPa) |
| Column Compatibility | Capillary and Analytical Format (e.g., 4 µm particle size columns) |
| Detector Options | DC Conductivity Detector (dual-zone temperature control), ED Electrochemical Detector, VWD/PDA UV-Vis Detector |
| Software | Dionex Chromeleon Chromatography Data System (CDS) |
| Compliance | Designed for GLP/GMP environments |
| Typical Service Life | ~10 years (refurbished & validated) |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Quanta 250 |
| Instrument Age | 5 Years |
| Vacuum Modes | High Vacuum, Low Vacuum, Environmental SEM (ESEM) Mode |
| Max Chamber Pressure | 2600 Pa |
| Accelerating Voltage Range | 200 V – 30 kV (continuously adjustable) |
| Stage Travel (Quanta 250) | X = Y = 50 mm |
| SE Resolution | 3.0 nm @ 30 kV (HV), 8 nm @ 3 kV (HV), 7 nm @ 3 kV (HV deceleration mode, optional), 3.0 nm @ 30 kV (LV), 10 nm @ 3 kV (LV), 3.0 nm @ 30 kV (ESEM) |
| BSE Resolution | 4.0 nm @ 30 kV |
| Brand | Thermo Fisher Scientific |
|---|---|
| Origin | USA |
| Model | XSeries II ICP-MS (Refurbished) |
| Mass Range | 2–260 amu |
| Sensitivity (Li-7) | 50 Mcps/ppm |
| Sensitivity (Y-89) | 60 Mcps/ppm (XSeries II standard configuration) |
| Sensitivity (Tl-205) | 80 Mcps/ppm |
| Detection Limit (Be-9) | 0.5 ppt |
| Detection Limit (In-115, Bi-209) | 0.1 ppt |
| Oxide Ratio (CeO+/Ce+) | ≤1.5% |
| Doubly Charged Ion Ratio (Ce2+/Ce+) | ≤3.0% |
| Isotopic Ratio Precision (107Ag/109Ag) | RSD ≤0.1% |
| Abundance Sensitivity (low-mass) | 5 × 10⁻⁷ |
| Abundance Sensitivity (high-mass) | 1 × 10⁻⁷ |
| Collision Cell | ORS3™ (He-only mode) |
| High Matrix Tolerance | Up to 3% total dissolved solids (TDS) via HMI technology |
| Software Platform | MassHunter Workstation (QA/QC, audit trail, automated method execution) |
| Brand | Thermo Fisher |
|---|---|
| Origin | USA |
| Model | UltiMate 3000 |
| Instrument Type | Liquid Chromatograph (UHPLC) |
| Maximum Pressure | 620 bar |
| UV Detector Wavelength Range | 190–900 nm |
| UV Noise | < ±2.5 µAU |
| UV Drift | < 0.1 mAU/h |
| Fluorescence Excitation/Emission Range | 200–900 nm |
| Wavelength Accuracy | ±2 nm |
| Wavelength Repeatability | ±0.2 nm |
| Autosampler Carryover | < 0.005% |
| Injection Cycle Time | 15 s |
| Column Oven Temperature Range | 5–85 °C |
| Temperature Stability | < ±0.1 °C |
| Solvent Channels | 6 |
| Degasser | Integrated Online Vacuum Degasser |
| Pump Configuration | Dual Triple-Quaternary Gradient System |
| Software | Chromeleon CDS (7.x or later) |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | 1200L |
| Mass Range | 10–1500 u |
| Scan Rate | 500–6000 u/s |
| ESI SIM Sensitivity | 10 pg reserpine, S/N > 50:1 |
| ESI MS/MS Sensitivity | 10 pg reserpine, S/N > 50:1 |
| Instrument Age | 4 years |
| Warranty | 6 months |
| Configuration | Triple quadrupole LC-MS/MS system with ProStar 210 dual LC pumps, ProStar 500 column valve module, Rainin CH-1 column heater, ProStar 410 autosampler, ProStar 330 PDA or 345 UV-Vis detector, rotary vacuum pump, dedicated P4 PC with Varian 1200/1200L MS workstation software and documentation |
| Brand | Varian |
|---|---|
| Origin | USA |
| Model | SpectrAA-220 |
| Detection Principle | Flame and Graphite Furnace Atomic Absorption Spectroscopy |
| Wavelength Range | 185–900 nm |
| Graphite Furnace Detection Limit (Cd) | ≤0.37 pg |
| Flame Detection Limit (Cu) | ≤0.0057 mg/mL |
| Precision (Graphite Furnace, Cd) | RSD <2% |
| Precision (Flame, Cu) | RSD <0.3% |
| Atomization System | Transversely Heated Graphite Tube (LTT-HP/LTT-HGO compatible) |
| Sample Introduction | Manual or SPS-5 Autosampler / SIPS-10 Dilution Module (optional) |
| Light Source | Multi-element Hollow Cathode Lamps |
| Dimensions (est.) | 800 × 500 × 450 mm (L×W×H) |
| Weight (est.) | 70–90 kg |
| Compliance | ASTM E1376, ISO 8288, USP <730>, GLP-ready data handling |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | e-SAT/IN |
| Condition | Refurbished & Fully Tested |
| Regulatory Status | CE-marked, Compliant with IEC 61000-6-3 EMI Standards |
| Interface | RS-232 / TTL-compatible digital output |
| Input Range | ±10 V analog input, 12-bit resolution |
| Sampling Rate | Up to 1 kHz (typical in legacy HPLC system integration) |
| Power Supply | +5 V DC (supplied via host chromatograph interface) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | Waters SQD |
| Mass Range | m/z 50–1000 |
| Ionization Sources | ESI and APCI |
| Detection Modes | Full Scan, SIM, SIR |
| Software | MassLynx v4.2 or later |
| Dynamic Range | 10⁶–10⁷ |
| Compliance | Designed for GLP/GMP environments |
| Brand | Waters |
|---|---|
| Origin | USA |
| Instrument Type | Triple Quadrupole LC-MS/MS |
| Mass Range | m/z 10–2000 |
| Ionization Sources | ESI & APCI |
| Scan Modes | Full Scan, SIM, MRM |
| MRM Acquisition Rate | Up to 1000 transitions/sec |
| Dynamic Range | 10⁶–10⁷ |
| Detection Limit | Low pmol/L (ESI-MRM) |
| Software | MassLynx v4.2 or later |
| Compliance | Designed for GLP/GMP environments |
| Typical Service Life | 3–5 years (verified operational history, full service logs available upon request) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Model | TQD |
| Mass Range | m/z 10–2000 |
| Ionization Sources | ESI & APCI |
| Scan Modes | Full Scan, SIM, MRM |
| MRM Transition Rate | Up to 1000 transitions/sec |
| Dynamic Range | 10⁶–10⁷ |
| Detection Limit | Low pmol/L (ESI) |
| Software | MassLynx v4.2 or later |
| Compliance | ASTM D7598, USP <1225>, FDA 21 CFR Part 11 (with audit trail enabled) |
| Brand | Waters |
|---|---|
| Origin | USA |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | UPLC + Xevo TQD |
| Price Range | USD $26,000 – $39,000 (FOB) |
| Operational Age | 3–5 years |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported Instrument |
| Model | SUPRA 1540 |
| Operational Age | 10 Years |
| Resolution | 2 nm @ 15 kV, 3 nm @ 1 kV |
| Magnification Range | 12× to 2,000,000× |
| Accelerating Voltage | 20 V – 30 kV (continuously adjustable) |
| Probe Current | 5 pA – 20 nA (optional extended range: 12 pA – 100 nA) |
| Chamber Dimensions | Ø330 mm × 270 mm (H) |
| Stage Motion | 5-axis motorized eucentric stage (X = 130 mm, Y = 130 mm, Z = 50 mm, Tilt = –3° to +70°, Rotation = 360° continuous) |
| Control System | SmartSEM software suite on Windows 7 platform, compatible with mouse, keyboard, and dedicated hardware control panel |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Model | GEMINI SUPRA 40 VP |
| Resolution | 1.3 nm @ 15 kV, 2.1 nm @ 1 kV, 5.0 nm @ 0.1 kV (Standard Mode) |
| Magnification Range | 12× – 900,000× |
| Accelerating Voltage | 0.02 – 30 kV |
| Beam Current | 4 pA – 10 nA (optional up to 20 nA) |
| Electron Source | Thermal Field Emission Gun (TFEG) |
| Detector Configuration | In-lens SE, ETSE, VPSE, STEM-in-SEM, and integrated Energy Dispersive X-ray Spectrometer (EDS) |
| Brand | ZEISS |
|---|---|
| Origin | Germany |
| Configuration | SUPRA 40VP + Oxford X-MaxN EDS + Symmetry EBSD |
| Operating Hours | ~6 years |
| Resolution | 1.0 nm @ 20 kV (SE), 2.0 nm @ 30 kV (VP mode) |
| Acceleration Voltage | 0.1–30 kV |
| Vacuum Mode Range | 2–133 Pa (variable pressure, 1 Pa step) |
| Probe Current | 4 pA–10 nA (up to 20 nA optional) |
| Chamber Dimensions | Ø330 mm × H270 mm |
| Stage Motion | 5-axis motorized (X/Y ±130 mm, Z 0–50 mm, Tilt −3° to +70°) |
| Magnification | 12×–900,000× |