UV Aging Test Chamber
Filter
Showing 61–90 of 107 results
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Sample Capacity | 500 × 400 mm Test Tray |
| Irradiation Source | Air-Cooled Metal Halide Lamp(s) |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Uniformity | ≥90% across Exposure Plane |
| Cooling Method | Internal Forced-Air Circulation |
| Filter | Custom High-Borosilicate Glass + Optional IR-Reduction Filter (30% IR attenuation) |
| UV Monitoring | Integrated Spectral Irradiance Transmitter (developed by No. 622 Research Institute) |
| Control Interface | LCD-Based Irradiance Accumulation Meter with Real-Time Dose Integration |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 21,500 (FOB) |
| Temperature Range | RT to 85 °C (Operating Range: 50 ±10 °C) |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temp. Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Irradiation Geometry | Top-Mounted Reflector-Based Direct Illumination |
| Spectral Output | 295–450 nm (UV-A/UV-B/Visible) |
| Irradiance Uniformity | ≥90 % across Sample Plane |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Temperature Range | RT to 85°C (operational test temp: 50 ± 10°C) |
| Humidity Range | 40–70% RH (lighting), 50–90% RH (dark cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW air-cooled metal halide lamp (1 unit) |
| Sample Rack | 500 × 400 mm stainless steel rack |
| Irradiation Geometry | Top-mounted, direct-reflection configuration |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² (at sample plane) |
| Irradiance Uniformity | ≥90% across exposure area |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50°C ±10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Irradiance | 200 ±8 W/m² (295–450 nm) |
| Spectral Range | 295–450 nm (UV-A/UV-B/VIS) |
| Irradiance Uniformity | ≥90% |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| UV Radiometer | Integrated Spectral Irradiance Transmitter (Calibrated per ISO 17025 Traceable Standards) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating Range: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted lamp with reflective direct irradiation |
| Spectral Range | 295–450 nm (UV-A/UV-B broadband) |
| Irradiance Level | 200 ± 8 W/m² |
| UV Radiometer | Integrated Spectral UV Irradiance Transmitter (developed by China Academy of Engineering Physics, Institute 622) |
| IR Filtering | Optional 30 % infrared energy rejection filter (custom order required) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85°C (Operating Range: 50°C ±10°C) |
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temperature Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temperature Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | ≤25 min (RT → 85°C) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted, Reflector-Assisted Direct Illumination |
| Spectral Range | 295–450 nm |
| Irradiance Uniformity | ≥90% across Exposure Plane |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 21,500 (approx.) |
| Key Features | Temperature Range: RT to 85°C (Operating Range: 50 ±10°C) |
|---|---|
| Humidity Range | 40–70% RH (Illumination), 50–90% RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5°C |
| Humidity Control Accuracy | ±2.0% RH |
| Temp. Uniformity | ±2.0°C |
| Humidity Uniformity | ±3.0% RH |
| Heating Rate | RT → 85°C in ≤25 min |
| Light Source | Single 2.5 kW Air-Cooled Metal Halide Lamp |
| Spectral Output | 295–450 nm (UV–Visible) |
| Irradiance at Sample Plane | 200 ±8 W/m² |
| Irradiance Uniformity | ≥90% |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-Mounted Reflector-Based Direct Irradiation |
| Compliance | Designed per ISO 4892-2, ASTM G154, IEC 60068-2-5, and GB/T 16422.2 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,600 (Reference Only) |
| UV Source | Fluorescent UVA-340 / UVB-313 Lamps |
| Condensation Mechanism | Integrated Cold Condensation System |
| Temperature Range | 40–70 °C (Operational Control) |
| Humidity Control | Simulated Dew via Condensation |
| Spray Function | Optional Water Spray Nozzle Assembly |
| Compliance | Designed to meet ASTM G154, ISO 4892-3, and SAE J2020 test protocols |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,650 (Reference Only) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 3,200 (FOB) |
| Internal Chamber Dimensions (W×H×D) | 114 × 40 × 40 cm |
| External Dimensions (W×H×D) | 135 × 140 × 65 cm |
| Temperature Range | Ambient to 70 °C |
| Humidity Range | ≥95% RH |
| Temperature Control Accuracy | ≤ ±0.5 °C |
| Temperature Uniformity | ≤ ±2 °C or ≤ ±3% |
| UV Lamp Type | Fluorescent UV Lamps (UVA-340 or UVB-313 equivalent) |
| UV Wavelength Range | 280–400 nm |
| Lamp Service Life | Approx. 2,000 hours |
| Exposure Time Setting Range | 0–999 h |
| Chamber Material | SUS#304 Stainless Steel (Interior & Exterior) |
| Heating System | U-shaped Titanium Alloy High-Speed Heating Elements |
| Safety Features | Interlocked UV lamp cutoff upon door opening, Overtemperature Protection, Low-Water Level Cut-off |
| Power Supply | AC 220 ±5 V, 50 ±0.5 Hz |
| Key | Brand: Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (operational test range: 50 ±10 °C) |
| Humidity Range | 40–70 % RH during irradiation |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Light Source | 2.5 kW air-cooled metal halide lamp (1 unit) |
| Sample Tray Dimensions | 500 × 400 mm |
| Irradiation Geometry | Top-mounted lamp with reflective direct irradiation |
| Spectral Range | 295–450 nm |
| Irradiance Level | 200 ±8 W/m² |
| UV Uniformity | ≥90 % across sample plane |
| Key Specifications | Temperature Range: RT to 85 °C (Operating Range: 50 ±10 °C) |
|---|---|
| Heating Rate | ≤25 min (RT → 85 °C) |
| Temp. Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temp. Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Humidity Range | 40–70 % RH (Illuminated) / 50–90 % RH (Dark Cycle) |
| Light Source | 2.5 kW Air-Cooled Metal Halide Lamp (1 unit) |
| Spectral Output | 295–450 nm |
| Irradiance | 200 ±8 W/m² (at sample plane) |
| Irradiance Uniformity | ≥90 % |
| Sample Tray Dimensions | 500 × 400 mm |
| Illumination Geometry | Top-mounted lamp with reflective direct irradiation |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Range | USD 2,500–3,200 (FOB) |
| UV Lamp Type | UVA-340 or UVB-313 |
| Temperature Range | 40–70 °C (controllable) |
| Humidity Control | Condensation cycle only (no active RH control) |
| Sample Capacity | Standard 48-position rack (75 mm × 150 mm specimens) |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, GB/T 14522 |
| Optional Features | Water Spray System, Black Panel Thermometer, Programmable Controller (LCD + USB data logging) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Temperature Range | RT to 85 °C (Operating: 50 ± 10 °C) |
| Humidity Range | 40–70 % RH (Illumination), 50–90 % RH (Dark Cycle) |
| Temp. Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temp. Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Ramp-up Time (RT → 85 °C) | ≤25 min |
| Light Source | 1 × 2.5 kW Air-Cooled Metal Halide Lamp |
| Spectral Range | 295–450 nm |
| Irradiance | 200 ± 8 W/m² |
| Irradiance Uniformity | ≥90 % |
| UV Sensor | Spectral Radiometric Transmitter (developed by No. 622 Institute) |
| Filter | Custom High-Borosilicate Glass (IR-blocking, ~30 % IR attenuation) |
| Black Panel Temperature (BPT) | 40–85 °C |
| Test Modes | UV Irradiation, Condensation, Water Spray, and Programmable Cycling |
| Sample Tray | 500 × 400 mm Stainless Steel Rack |
| Illumination Geometry | Top-mounted lamp with reflective direct irradiation |
| Cooling | Integrated Forced-Air Internal Circulation System |
| Irradiance Integration | LCD-based Real-Time Accumulated Dose Calculator |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (Reference Only) |
| Light Source | UVA-340 or UVB-313 Fluorescent Lamps |
| Cycle Modes | UV Irradiation + Condensation / UV + Spray |
| Temperature Range | 40–70°C (UV), 40–60°C (Condensation) |
| Humidity Control | 90–100% RH during Condensation Phase |
| Sample Capacity | Standard 48-position rack (75 × 150 mm specimens) |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, GB/T 14522 |
| Optional Features | Water Spray System, Black Panel Thermometer, Irradiance Monitoring Sensor |
| [Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (Reference Only)] |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (Reference Only) |
| UV Lamp Type | UVA-340 or UVB-313 Fluorescent Lamps |
| Temperature Range | 40–70°C (Irradiation), 30–60°C (Condensation) |
| Humidity Control | Condensation Cycle via Water Reservoir |
| Sample Capacity | Standard 3–5 Specimen Holders (75 × 150 mm) |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, GB/T 14522 |
| Optional Features | Water Spray System, Irradiance Monitoring Sensor, Programmable Cycling Controller |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,650 (Reference Only) |
| UV Lamp Type | UVA-340 or UVB-313 |
| Temperature Range | 40–70°C (Controlled) |
| Humidity Control | Condensation Cycle (Non-saturated) |
| Irradiance Control | Yes (Optional) |
| Spray Function | Integrated Water Spray System |
| Compliance | ASTM G154, ISO 4892-3, SAE J2020, GB/T 14522 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (Reference Only) |
| UV Lamp Type | UVA-340 or UVB-313 |
| Temperature Range | 40°C to 80°C (operational control) |
| Humidity Control | Condensation Cycle (50–95% RH) |
| Irradiance Control | Digital Radiometer with Feedback Loop |
| Sample Capacity | Standard 48-position rack (75 mm × 150 mm specimen area) |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020 |
| Optional Features | Water Spray System, Black Panel Thermometer, Programmable Cycle Sequencing |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (Reference Only) |
| UV Light Source | UVA-340 or UVB-313 Fluorescent Lamps |
| Temperature Range | 40°C to 80°C (Irradiance-Controlled) |
| Humidity Control | Condensation Cycle (50–95% RH) |
| Spray Function | Optional Deionized Water Spray |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, GB/T 14522 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,600 (Reference Only) |
| UV Source | Fluorescent UVA-340 / UVB-313 Lamps |
| Condensation Mechanism | Integrated Cold Condensation System |
| Temperature Range | 40–70 °C (Irradiation), 40–60 °C (Condensation) |
| Humidity Control | 90–100% RH during Condensation Cycle |
| Cycling Modes | UV Irradiation / Condensation / Optional Water Spray |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, GB/T 14522 |
| Safety Features | UV Interlock Door Switch, Over-Temp Protection, Emergency Stop, Ocular UV Shielding |
| Brand | OEM / Generic |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price Reference | USD 2,600 (excl. tax & freight) |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,600 (Reference Only) |
| UV Source | Fluorescent UVA-340 / UVB-313 Lamps |
| Condensation Mechanism | Integrated Cold Condensation System |
| Temperature Range | 40–70 °C (Operational Control) |
| Humidity Control | Simulated Dew via Condensation |
| Cycle Modes | UV Irradiation + Condensation |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, GB/T 14522 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,600 (Reference Only) |
| UV Source | Fluorescent UVA-340 / UVB-313 Lamps |
| Temperature Range | 40–75°C (Controlled) |
| Humidity Simulation | Condensation Cycle (50–95% RH) |
| Irradiance Control | Yes (via calibrated sensor) |
| Spray Function | Integrated Water Spray System |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020 |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | General Distributor |
| Price | USD 2,600 (Reference Only) |
| UV Source | Fluorescent UVA-340 / UVB-313 Lamps |
| Condensation Cycle | Humidity-controlled Cold Dew Simulation |
| Temperature Range | 40–70 °C (Operational) |
| Irradiance Control | Yes (Calibrated Sensor) |
| Spray Function | Integrated Water Spray System |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020 |
| Sample Capacity | Standard 3–5 Specimen Holders (75 × 150 mm) |
| Cabinet Construction | Stainless Steel 304 Interior, Powder-Coated Steel Exterior |
| Brand | Other Brands |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 2,650 (Reference Only) |
| UV Lamp Type | UVA-340 or UVB-313 |
| Temperature Range | 40–70°C (Irradiation), 30–60°C (Condensation) |
| Humidity Control | Condensation Cycle via Water Reservoir |
| Sample Capacity | Standard 3–5 Specimen Holders |
| Compliance | ASTM G154, ISO 4892-3, JIS D0205, SAE J2020 |
| Optional Features | Water Spray Function, Irradiance Monitoring Sensor, Touchscreen Controller |
| Key Specifications | Temperature Range: RT to 85 °C (operational test range: 50 °C ±10 °C) |
|---|---|
| Humidity Range | 40–70 % RH during irradiation |
| Temperature Control Accuracy | ±0.5 °C |
| Humidity Control Accuracy | ±2.0 % RH |
| Temperature Uniformity | ±2.0 °C |
| Humidity Uniformity | ±3.0 % RH |
| Heating Rate | ≤25 min (RT → 85 °C) |
| Radiation Source | Single 2.5 kW air-cooled metal halide lamp |
| Spectral Output | 295–450 nm, filtered to match terrestrial solar UV + visible irradiance through 3 mm borosilicate glass |
| Sample Tray Dimensions | 500 × 400 mm |
| Brand | OK Instruments |
|---|---|
| Origin | Imported |
| Manufacturer Type | Authorized Distributor |
| Price | USD 3,150 (FOB) |
| Internal Chamber Dimensions (W×H×D) | 114 × 40 × 40 cm |
| External Dimensions (W×H×D) | 135 × 140 × 65 cm |
| Temperature Range | Ambient to 70 °C |
| Humidity Control | ≥95% RH during condensation cycle |
| Temperature Uniformity | ≤±2 °C (at setpoint) |
| Temperature Accuracy | ≤±0.5 °C |
| UV Lamp Type | Fluorescent UVA-340 or UVB-313 lamps (standard configuration) |
| Spectral Range | 280–400 nm |
| Lamp Lifetime | Approx. 2,000 hours |
| Exposure Time Setting | 0–999 hours (digital timer with auto-cycling) |
| Construction | Interior & exterior chamber walls — AISI 304 stainless steel |
| Heating System | U-shaped titanium alloy high-speed heating elements |
| Safety Features | Interlocked door cut-off for UV lamp power, over-temperature protection, low-water level cutoff, automatic thermal equilibrium recovery |