Western Blotting System
Filter
Showing all 7 results
| Brand | ACV |
|---|---|
| Origin | Shandong, China |
| Model | ProLux Series |
| Instrument Type | WB Imaging & Processing System |
| Automation Level | Fully Automated |
| Transfer Method | Wet Transfer |
| Maximum Gel Capacity (Electrophoresis) | 4 mini-gels |
| Maximum Transfer Capacity | 2 gels (100 mm × 75 mm) |
| Temperature Control Range | 2–40 °C (Peltier-based) |
| Incubation Channels | 12 independent channels |
| Membrane Throughput | up to 24 membranes per run |
| Wash Buffer Volume Control | Adjustable per cycle |
| Imaging Sensor | High-sensitivity cooled CMOS |
| Light Sources | LED-based transillumination and epi-illumination |
| Fluorescence Channels | RGB + Far-Red/NIR (upgradable) |
| Software Compliance | FDA 21 CFR Part 11-ready audit trail, GLP/GMP-compatible workflow logging |
| Brand | Aperbio |
|---|---|
| Origin | Jiangsu, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | CycleBlot |
| Instrument Type | Protein Transfer System |
| Automation Level | Semi-Automatic |
| Transfer Method | Wet Transfer |
| Transfer Dimensions | 110 × 90 mm |
| Gel Capacity | 1–4 mini gels |
| Molecular Weight Range | 5–200 kDa |
| Transfer Time | 20 min |
| Cooling System | Peltier-based recirculating cooling |
| Reagent Compatibility | Standard transfer buffers (e.g., Tris-Glycine, CAPS, Bicine) |
| Brand | Bio-Rad |
|---|---|
| Origin | Singapore |
| Model | Trans-Blot Turbo |
| Automation Level | Fully Automated Western Blot Transfer System |
| Throughput | 4 mini gels or 2 midi gels per run |
| Dual Cassette Design | Yes |
| Transfer Time | ≤3 min (2 TGX Mini Gels), ≤7 min (4 standard mini gels or 2 midi gels) |
| Power Supply | Integrated constant voltage/current/power regulator |
| User Interface | Backlit LCD touchscreen with programmable protocol storage (25 protocols) |
| Electrode Architecture | 6-spring-loaded parallel plate electrodes |
| Pre-formulated Kits | Compatible with Turbo Transfer Packs (buffer-free, membrane-ready) |
| Compatibility | Works with standard PVDF/nitrocellulose membranes, conventional electrophoresis buffers (e.g., Tris-Glycine, CAPS), and legacy gel formats |
| Brand | PacificImage |
|---|---|
| Origin | Taiwan |
| Model | Glite 600UV/BW |
| Instrument Type | Semi-Automatic Western Blotting & Gel Imaging System |
| Camera | Starlight-grade CMOS, 6 MP (3096 × 2080) |
| Bit Depth | 8/16-bit output |
| Exposure Time | 5 ms – 10 s |
| Excitation Sources | UV (302 nm), Blue LED (470 nm), White LED (optional) |
| Imaging Area | 13 × 18 cm |
| Filter Holder | Manual dual-slot |
| Emission Filter | 620 nm bandpass amber filter |
| Operating System | Windows 7/8/10 |
| Image Formats | TIFF, JPEG, BMP |
| Interface | USB 3.0 |
| Dimensions (W×H×D) | 300 × 260 × 257 mm |
| Weight | 10 kg |
| Brand | Sartorius |
|---|---|
| Origin | Germany |
| Model | 11327-41BL (0.22 µm), 11306-41BL (0.45 µm) |
| Format | Roll (30 cm × 3 m) |
| Protein Binding Capacity | >200 µg/cm² (IgG) |
| Pore Size Options | 0.22 µm, 0.45 µm |
| Pretreatment | Water-wet only — no methanol activation required |
| Material | 100% pure nitrocellulose |
| Compliance | Suitable for ISO/IEC 17025-compliant laboratories |
| Brand | WIX |
|---|---|
| Origin | Shanghai, China |
| Model | WIX-autoPP Automated Western Blot Processing System |
| Throughput | Up to 24 membranes per run |
| Incubation Modules | 12 independently controlled modules |
| Temperature Control Range | 4–40 °C |
| Antibody Recovery Rate | ≥95% (up to 10 reuses) |
| Module Dimensions (optional) | 3×8 cm, 6×8 cm, or 9×8 cm |
| Membrane Wetting Maintenance | On-board wash buffer retention post-incubation |
| Fluidic Cross-Contamination Prevention | Automated in-line tubing rinse cycles |
| Compatibility | Open-platform design supports third-party primary/secondary antibodies and wash buffers |
| Brand | Youyunpu |
|---|---|
| Origin | Shandong, China |
| Manufacturer Type | OEM Manufacturer |
| Instrument Type | Protein Transfer System |
| Automation Level | Fully Automated |
| Transfer Method | Semi-Dry Electrophoretic Transfer |
| Max Output Voltage | 0–25 V (1 V increments) |
| Max Output Current | 0–2.5 A (0.1 A increments) |
| Display | 7-inch capacitive touchscreen with real-time parameter monitoring |
| Programmable Methods | 25 user-defined protocols |
| Transfer Plate Dimensions | 18.0 × 14.5 cm |
| Throughput | 1–4 mini gels or 1–2 midi gels per run |
| Compatible Buffers | Optimized semi-dry transfer buffer concentrate (supplied) |
| Recommended Applications | Proteins ≤180 kDa (transfer time: 7–15 min at 25 V constant voltage) |