X-ray Diffractometer
Filter
Showing 1–30 of 35 results
| Brand | Along |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Regional Classification | Domestic (PRC) |
| Model | JF-2000 |
| Pricing | Available Upon Request |
| Brand | Along |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Model Series | YX-2, YX-200, YX-2H8, YX-300, YX-2A, YX-2B |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger-Müller counter |
| Angular Range | θ = −10° to +50°, 2θ = −10° to +100° |
| Angular Resolution | 10 arcseconds (digital display) |
| Accuracy | ±30″ (YX-2, YX-2H8, YX-2A left channel), ±10″ (YX-200, YX-300, YX-2A/YX-2B right channel), ±3″ or ±1″ (YX-300 & YX-2B right channel, min. readout) |
| Slit Options | 4′, 5′, 6′ |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Power Supply | 220 V AC, 50 Hz, 0.3 kW |
| Dimensions (L×W×H) | 1140–1150 mm × 650–665 mm × 1030–1100 mm |
| Weight | 150–170 kg |
| Brand | Anton Paar |
|---|---|
| Origin | Austria |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Product Origin | Imported |
| Model | XRDynamic Autosampler |
| Instrument Type | X-ray Crystal Orientation Analyzer |
| Instrument Configuration | Floor-standing |
| Sample Capacity | Up to 105 positions |
| Compatible With | XRDynamic 500 XRD system |
| Integration | Native integration with XRDdrive software |
| Sample Holder Compatibility | Standard ISO/ASTM-compliant sample holders (powder, solid, fiber, foil, thin film, air-sensitive samples) |
| Measurement Modes | Reflective and transmission geometries |
| Automation Level | Fully automated sample loading, positioning, alignment, and beam path switching |
| Compliance | Designed to support GLP/GMP workflows with audit-trail-capable software logging |
| Brand | Anyty |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Original Equipment Manufacturer (OEM) |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Form Factor | Benchtop |
| Power Consumption | 600 W |
| Angular Accuracy | ±0.02° |
| Angular Resolution | 0.04° |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Product Category | Domestic |
| Model | AL-Y3000 |
| Instrument Type | Powder X-ray Diffractometer |
| Angular Resolution | 0.001° (1/1000°) |
| Geometry | θ–θ configuration |
| X-ray Source | Sealed Metal-Ceramic Tube |
| Detector | Silicon Drift Detector (SDD) |
| Primary Optics | Interchangeable Focusing and Parallel-Beam Optics via 90° Monochromator Rotation |
| Software | Integrated Rietveld Refinement, ICDD/ICSD Database Integration, Stress & Texture Analysis Modules |
| Compliance | Designed for GLP-compliant laboratories |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Model | ALW-XYDZ 700 |
| Power Supply | AC 220 V, 50 Hz, 0.25 kW |
| X-ray Tube | Cu anode, fan-cooled, grounded anode |
| Max. Tube Voltage/Current | 30 kV / 5 mA (continuously adjustable |
| Detector Options | Proportional counter (DC 1000 V max) or scintillation detector (DC 1200 V max) |
| Time Constant Settings | Fast (1) / Slow (2) |
| Angular Range | 2θ = −10° to 110°, θ = −5° to 55° |
| Angular Resolution | 1 arcsecond (1″), equivalent to 0.000278° |
| Angular Reproducibility | ±15″ / ±30″ (double-diffraction mode, verified with NIST-traceable quartz reference crystal) |
| Optical Shutter | Manual main shutter |
| Display Interface | Real-time angle readout + X-ray intensity meter |
| Dimensions (L×W×H) | 1132 × 642 × 1460 mm |
| Weight | 300 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Country of Origin | China |
| Model | ALW-XYDZ 700A |
| Price | Upon Request |
| Input Power | AC 220 V, 50 Hz, 0.25 kW |
| X-ray Tube | Cu anode, fan-cooled, grounded anode |
| Max. Tube Voltage/Current | 30 kV / 5 mA (continuously adjustable |
| Detector Options | Geiger–Müller counter (DC ≤1000 V) or scintillation detector (DC ≤1200 V) |
| Time Constant Settings | Fast (1) / Slow (2) |
| Angular Range | 2θ = −10° to 110°, θ = −5° to 55° |
| Angular Resolution | 1 arcsecond (″) in DMS format |
| Angular Accuracy (Double-Diffraction Mode) | ±15″ or ±30″ (verified using NIST-traceable quartz reference crystal) |
| Shielding | Fully enclosed lead-lined cabinet with interlocked automatic main shutter |
| Display | Dual digital readout — angular position (DMS + decimal degree, with presettable target and deviation) and X-ray intensity |
| Dimensions (L×W×H) | 1132 × 642 × 1460 mm |
| Weight | 300 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic (China) |
| Model | ALYX-500 |
| Price | Upon Request |
| Input Power | 220 V AC, 50 Hz, 0.3 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger–Müller counter |
| Angular Range | θ = −10° to +50°, 2θ = −10° to +100° |
| Angular Resolution | Digital readout with programmable positioning |
| Beam Shutter | Motorized |
| Dimensions | 700 × 530 × 1400 mm (L × W × H) |
| Weight | 100 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | ALYX-800 |
| Price | Upon Request |
| Input Power | 220 V AC, 50 Hz, 0.3 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger-Müller counter |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Optical Shutter | Manual |
| Dimensions | 910 mm (L) × 660 mm (W) × 1220 mm (H) |
| Weight | 150 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | OEM Manufacturer |
| Origin Category | Domestic (China) |
| Model | Sapphire Four-Axis |
| Input Power | 220 V AC, 50 Hz, 0.3 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Time Constants | 0.1 s / 0.4 s / 3 s |
| Slit Apertures | 4′ / 5′ / 6′ |
| Optical Shutter | Motorized |
| Control Unit Dimensions | 550 × 350 × 1700 mm (L×W×H) |
| Measurement Unit Dimensions | 750 × 550 × 1800 mm (L×W×H) |
| Weight | 180 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Origin Category | Domestic (China) |
| Model | YX-200 |
| Price | Upon Request |
| X-ray Tube | Cu anode, air-cooled, 30 kV / 0–5 mA |
| Detector | Geiger-Müller counter |
| Angular Range | θ = −10° to +50°, 2θ = −10° to +100° |
| Angular Resolution | 10 arcseconds (″) |
| Digital Display | Degrees, Minutes, Seconds |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Input Power | 220 V AC, 50 Hz, 0.3 kW |
| Dimensions | 1140 × 650 × 1030 mm (L×W×H) |
| Weight | 150 kg |
| Brand | Aolong |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Manufacturer |
| Origin Category | Domestic |
| Model | YX-300 |
| Price | Upon Request |
| Input Power | 220 V AC, 50 Hz, 0.3 kW |
| X-ray Tube | Cu anode, air-cooled, 30 kV, 0–5 mA |
| Detector | Geiger–Müller counter |
| Time Constants | 0.1 s, 0.4 s, 3 s |
| Angular Range | θ = −10° to +50°, 2θ = −10° to +100° |
| Angular Resolution | 1″ (digital display), minimum readable increment 1″ |
| Accuracy | ±10″ |
| Optical Shutter | Manual |
| Display | Digital angle readout |
| Dimensions | 1150 mm × 665 mm × 1040 mm (L×W×H) |
| Weight | 150 kg |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | D6 PHASER |
| Instrument Type | Powder X-ray Diffractometer |
| Generator Power | 600 W or 1200 W |
| 2θ Calibration Accuracy | ±0.01° |
| Detector | LYNXEYE XE-T Energy-Resolving Detector |
| Beam Optimization | Dynamic Beam Optimization (DBO) |
| Cooling | Air-Cooled (No External Water Chiller Required) |
| Footprint | Compact Benchtop Design |
| Measurement Geometries | Bragg–Brentano Reflection, Transmission, Grazing-Incidence XRD (GIXRD), X-ray Reflectivity (XRR), Residual Stress Analysis, Texture Analysis |
| Brand | GKInst |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Product Category | Domestic |
| Model | D7 Mate |
| Price Range | USD 28,000 – 140,000 |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| Power Rating | 600 W / 1200 W (Selectable) |
| Angular Accuracy | ±0.0001° |
| High-Voltage Generator | 40 kV / 600 W or 40 kV / 1200 W |
| Target Materials | Cu, Cr, Mo |
| Goniometer Geometry | Horizontal θ/2θ or ω/θ |
| Goniometer Radius | 150 mm |
| Angular Range | −3° to 152° (140° with automatic beam-defining slit) |
| Repeatability | <0.0001° (2σ) |
| Detector | 640-channel 1D silicon strip detector, active area 32 mm × 8 mm |
| Cooling | Integrated recirculating water chiller (standard), optional external chiller interface |
| Beam Path | Air-scatter suppression module with motorized divergence slit and automatic anti-scatter device |
| Sample Stages | Fixed stage, in-situ heating stage, multi-axis rotating stage, capillary stage, thin-film stage, multifunctional stage, pouch-cell battery stage, high-throughput 8-position rotary stage, optional 6-position automated sample loader |
| Data Reproducibility | NIST SRM 660c LaB₆ reference standard, RSD ≤ 0.003% (peak position, 2θ) |
| Control Interface | External PC or integrated 10.1″ capacitive touchscreen |
| Dimensions (L×W×H) | 880 mm × 705 mm × 735 mm |
| Mass | ≤180 kg |
| Electrical Supply | AC 200–240 V, 50/60 Hz |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | D8 ADVANCE |
| Instrument Type | Powder X-ray Diffractometer |
| Power | 0.0001° angular resolution |
| 2θ Range | −110° to +168° |
| X-ray Tube Targets | Cr / Co / Cu (standard-size) |
| Detector Options | LYNXEYE Array Detector, LYNXEYE XE-T Energy-Dispersive Detector |
| Dimensions | 1868 × 1300 × 1135 mm |
| Weight | 770 kg |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | D8 DISCOVER |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 0.0001 kW |
| Compliance | Fully Compliant with ISO 17025, ASTM E975, and IEC 61000-6-3 for Electromagnetic Compatibility |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Powder X-ray Diffractometer |
| Model | D8 ENDEAVOR |
| Detector | LYNXEYE XE-T Energy-Resolving Array Detector |
| Sample Handling | 66-position or 72-position automated sample changer (Ø 51.5 mm and Ø 40 mm formats) |
| Automation Modes | Belt-driven or robotic integration |
| Compliance | Designed for GLP/GMP environments with audit-trail-ready software architecture |
| Regulatory Context | Fully compatible with FDA 21 CFR Part 11–compliant data management workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | D8 QUEST |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Power | 200 W (0.0002 MW) |
| Detector | PHOTON III MMPAD Hybrid Photon Counting Detector |
| Source Options | Microfocus Rotating Anode (Cu/Mo), Liquid Metal Jet (Ga/In), Dual-Target Auto-Switching |
| Software | APEX3 / PROTEUM3 |
| Compliance | ISO 17025-ready, GLP/GMP-supportive data audit trails, FDA 21 CFR Part 11 compliant modules available |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Model | D8 VENTURE |
| Instrument Type | Single-Crystal X-ray Diffractometer |
| Power | 200 W (0.0002 MW) |
| Detector | PHOTON III MMPAD Hybrid Photon-Counting Detector |
| X-ray Source Options | microfocus sealed-tube (Incoatec IμS 3.0), liquid-metal-jet (MetalJet), dual-target auto-switching |
| Software | APEX4 (successor to APEX3/PROTEUM3) |
| Compliance | Fully compatible with CIF deposition standards, supports IUCr-compliant data reduction and structure refinement workflows |
| Brand | Bruker |
|---|---|
| Origin | Germany |
| Instrument Type | Powder X-ray Diffractometer |
| Model | JV QC3 |
| Application Focus | Compound Semiconductor Epitaxial Layer & Substrate QC |
| Automation Level | Fully Automated Wafer Handling (Optional Robotic Arm) |
| Sample Capacity | Up to 4 × 100 mm wafers per batch |
| Compliance | Designed for ISO/IEC 17025-aligned semiconductor manufacturing environments |
| Software Platform | Bruker JV-RADS (Bede RADS) with automated peak fitting, strain/relaxation quantification, and multi-layer compositional analysis |
| X-ray Source Protection | XRG Protect™ tube longevity technology |
| Power Mode | Eco-standby with reduced idle power consumption |
| Brand | GKINST |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Domestic |
| Model | D-POWER |
| Price Range | USD 42,000 – 210,000 |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Floor-standing |
| Power Rating | 3 kW |
| Angular Accuracy | 0.0001° |
| Brand | GBC |
|---|---|
| Origin | Australia |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Emma |
| Price Range | USD 135,000 – 205,000 (FOB Australia) |
| Instrument Type | Powder X-ray Diffractometer |
| Power Consumption | <0.1 W (standby), <150 W (operational) |
| Beam Geometry | Variable parallel-beam and Bragg–Brentano focusing geometry |
| Sample Stage | Motorized variable-height powder stage + Eulerian cradle (χ, φ, ω rotation) |
| Detector Configuration | Dual fixed-position detectors — one parallel-beam detector with 0.4° Soller slit collimator, one focusing detector with variable slits and graphite monochromator |
| X-ray Source Optics | XOS polycapillary optic delivering 10 × 10 mm quasi-parallel beam |
| parallel-beam radius | 250 mm |
| focusing radius range | 175–250 mm |
| Optional Integrated Detection | Simultaneous XRD/XRF capability via integrated Si-PIN or SDD X-ray fluorescence detector |
| Portability | Modular chassis with integrated handles |
| Goniometer | Harmonic drive-based θ–2θ goniometer with <0.001° angular reproducibility |
| Radiation Safety | Lead-acrylic interlocked viewing window (large-format, wide-field), software-controlled actuation |
| Electronics | Industrial-grade FPGA-based control architecture with GLP-compliant event logging |
| Brand | GKINST |
|---|---|
| Origin | Anhui, China |
| Manufacturer Type | Authorized Distributor |
| Country of Origin | China |
| Model | HPXRD |
| Configuration | Floor-Standing |
| X-ray Source | Liquid-Metal In Target (E1 Type) |
| High-Flux Mode | 90 μm focal spot, 1.9 × 10⁸ ph/s, divergence 3.15 mrad |
| Micro-Focus Mode | 15 μm focal spot, 1.8 × 10⁷ ph/s, divergence 12.6 mrad |
| Ultra-Micro Mode | 10 μm focal spot, 1.0 × 10⁶ ph/s, divergence 2 mrad |
| XY Stage Repeatability | ±0.2 μm, travel ±10 mm |
| Z Stage Repeatability | ±0.2 μm, travel ±10 mm |
| φ Axis Repeatability | 0.002°, travel ±135° |
| X₁Y₁ Stage Repeatability | ±0.2 μm, travel ±12.5 mm |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | APD 2000 PRO |
| Instrument Type | Powder X-ray Diffractometer |
| X-ray Tube Power | 0.0001 kW (100 W) |
| Radiation Source | Fine-focus Ceramic X-ray Tube |
| Monochromator | Johannson-type Kα₁ monochromator |
| Detector Types | Scintillation Counter & Energy-Dispersive Detector |
| Goniometer Control | Optical Encoder |
| Sample Stage | Motorized Multi-Sample Rotating Stage with Low-Background Options |
| Safety System | Dual Redundant Interlock Circuit |
| Compliance | CE, IEC 61010-1, ISO 9001 |
| Brand | GNR |
|---|---|
| Origin | Italy |
| Model | EXPLORER |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 0.0001 kW |
| Optical Configuration | Switchable Bragg-Brentano focusing / Johansson monochromator / Parabolic mirror monochromator |
| Beam Geometry | Parallel-beam optics with low-angle reflection capability |
| Thin-film Thickness Detection Range | 1–500 nm |
| Degrees of Freedom for Sample Manipulation | 5 |
| Modular Units | 7 |
| Primary Applications | Phase identification & quantification, crystallite size and microstrain analysis, residual stress measurement, texture analysis, thin-film characterization, depth profiling, nanocrystalline material assessment |
| Brand | Haoyuan |
|---|---|
| Origin | Liaoning, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic |
| Model | DX-2700BH |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Floor-standing |
| X-ray Generator Power | 3 kW |
| Angular Accuracy | ±0.0001° |
| Resolution (FWHM) | SiO₂ ≤ 60% |
| Brand | JWGB |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Instrument Type | Powder X-ray Diffractometer |
| Configuration | Benchtop |
| X-ray Source | Sealed Mo-target Tube |
| Maximum Power | 1600 W |
| Angular Accuracy | ±0.01° |
| Angular Resolution | 0.1° |
| Goniometer Geometry | Vertical θ–2θ |
| Goniometer Radius | 144 mm |
| Angular Range | 0°–150° |
| Detector | Photon-counting 2D Array Detector |
| Sample Stage | Temperature-Controlled Pouch-Cell Holder (−30 °C to 300 °C) |
| Dimensions | 900 mm × 680 mm × 550 mm |
| Weight | 100 kg |
| Brand | Malvern PANalytical |
|---|---|
| Origin | United Kingdom |
| Manufacturer Type | Authorized Distributor |
| Origin Category | Imported |
| Model | Aeris Cement Edition |
| Pricing | Upon Request |
| Brand | Persee |
|---|---|
| Origin | Beijing, China |
| Manufacturer Type | Direct Manufacturer |
| Product Category | Domestic (China-made) |
| Model | XD-2 / XD-3 |
| Instrument Type | Powder X-ray Diffractometer |
| Price Range | USD 70,000 – 140,000 (FOB China) |
| Detector | Imported NaI Scintillation Counter |
| Goniometer Configuration | Vertical θ–θ geometry with hollow-axis design |
| X-ray Source Control | Fully digital, microprocessor-regulated high-voltage and tube current |
| Software | PDP Diffraction Data Processing Suite (Windows-based, multi-format export support) |
| Brand | Rigaku |
|---|---|
| Origin | Japan |
| Model | MiniFlex600 |
| Instrument Type | Powder X-ray Diffractometer |
| Power Rating | 0.0001 kW |
| Dimensions | 560 W × 460 D × 700 H mm |
| Detector Type | Advanced Semiconductor Detector |
| Software Suite | PDXL (Phase Identification, Quantitative Analysis, Rietveld Refinement, Crystal Structure Visualization) |