Empowering Scientific Discovery

Xi'an Yingrun Environmental Technology Group Co., Ltd.

Categories
  • All
  • Favorite
  • Popular
  • Most rated
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERUN
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelERUN-ST7-B4
Instrument TypeLaboratory Benchtop Volatile Phenol Analyzer
Measurement PrincipleSpectrophotometry (4-Aminoantipyrine Method per ISO 6439 & HJ 503-2009)
Range0.2–10.00 mg/L
Accuracy±5% FS
Repeatability≤2% RSD
Baseline Drift<0.002 Abs/30 min
Wavelength SelectionAuto-selectable (500 nm standard for phenol detection)
Optical SystemFixed-wavelength LED-based photometer with calibrated optical path
Light Intensity Control16-step adjustable intensity
Calibration Curve OptionsLinear or Multi-point Nonlinear (up to 8 calibration points)
Data Storage100,000 records (timestamp, absorbance, transmittance, concentration, user ID, curve ID)
Display7-inch capacitive color touchscreen with on-screen operation guide
ConnectivityUSB 2.0 host port for data export (CSV format), no network or cloud interface
Power SupplyAC 220 V ±10%, 50 Hz ±0.5 Hz
Environmental RequirementsStable lab environment — no direct sunlight, minimal vibration, low EMI
ComplianceDesigned to support compliance with ISO/IEC 17025 quality management systems
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERUN
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of ManufactureChina
ModelERUN-SP5-D4
Instrument TypePortable
Detection MethodSpectrophotometric (ISO 6703-1 compliant)
Measurement Range0.01–0.50 mg/L CN⁻
LOD0.005 mg/L
Accuracy±5% FS
Repeatability≤3% RSD
Optical StabilityΔA < 0.002 in 20 min
DisplayBacklit LCD
Data Storage20 calibration curves + 199 timestamped results (YYYY-MM-DD HH:MM:SS, Absorbance, Transmittance, Concentration)
Power Supply4 × AA batteries
EnclosureIP65-rated ABS housing
Dimensions80 × 230 × 55 mm
Weight500 g
Operating Temperature5–40 °C
Relative Humidity≤85% RH (non-condensing)
ComplianceGB 5749-2022, GB 3838-2002, ISO 6703-1:2018
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERUN
ModelERUN-SP3-L
OriginShaanxi, China
TypePortable microbial analyzer
Detection TargetsEscherichia coli, total coliforms, thermotolerant coliforms, heterotrophic plate count (HPC)
Filtration Pore Size0.45 µm
Weight<3.5 kg
Temperature Control Range10–60 °C
Operating Temperature Range0–60 °C
Power SupplyRechargeable battery, vehicle charger, AC adapter
DisplayLCD with Chinese UI
Data InterfaceMicro-USB
Sterilization MethodFlame sterilization (1200 °C) compatible for filtration components
Culture Vessel CompatibilityUp to 4 standard glass Petri dishes or 20 aluminum dishes
ComplianceGB/T 5750.12–2023, GB/T 5750.13–2006, HJ 1001–2018
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERUN
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelERUN-SP7-18
Instrument TypePortable
Detection PrinciplePhotometric (Colorimetric) Method
Detectable MetalsCu, Zn, Cr(VI), Pb, Hg, Ni, Fe, Mn, Al, Cd, As, Ag, Mo, Be, B, Sb, Ba
Analysis Time≤3 min per parameter
Accuracy±5% of Full Scale (F.S.)
Resolution0.1 mg/L (for most parameters)
Repeatability≤3% RSD
Optical StabilityDrift < 0.002 A in 20 min
Display5.0-inch TFT LCD
Data Storage100 calibration curves + 1999 tagged measurement records (with timestamp & parameter ID)
Power SupplyInternal rechargeable Li-ion battery + AC adapter (dual-power system)
Dimensions410 × 300 × 130 mm
Weight4.0 kg
Power Consumption<10 W
OutputBuilt-in thermal printer
ConnectivityUSB port
Measurement ModesConcentration, Absorbance, Transmittance
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERUN
OriginShaanxi, China
ModelERUN-SZ4-K4
Instrument TypeOnline Analyzer
Measured ParameterChlorine Dioxide (ClO₂)
Measurement Range0–5 mg/L and 0–20 mg/L (dual-range)
Accuracy±3% of reading
Repeatability±3%
Resolution0.001 mg/L
Limit of Detection0.030 mg/L
Response Time (T90)≤90 s
Measurement PrincipleAmperometric Electrochemical Detection (Three-Electrode System with Membrane-Covered Gold Working Electrode)
Temperature Range−5 to 60 °C
Temp. Accuracy±0.4 °C
Temp. Resolution0.1 °C
Operating VoltageDC 9–28 V
Power Consumption≤0.5 W (peak)
Output OptionsRS485 (Modbus RTU), 4–20 mA (optional)
Enclosure RatingIP68
Pressure Rating<0.1 MPa
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERUN
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Product CategoryDomestic
ModelERUN-ST7-D4
Instrument TypeBenchtop Laboratory Analyzer
Measurement PrincipleSpectrophotometric Method (ISO 6439, APHA 4500-CN⁻ F/G)
Wavelength SelectionAutomatic, Dual-Beam Optical System
Wavelength Repeatability±0.2 nm
Photometric Range0–3.0 A
Light Intensity Control16-step Adjustable LED Source
Calibration ModesLinear & Multi-Point Nonlinear (Piecewise)
Data Storage Capacity100,000 Records with Timestamp, Sample ID, Operator ID, and Calibration Log
Data RecoveryBuilt-in Backup/Restore for Calibration Curves & Measurement History
Auto-Reset FunctionFactory Reset with Audit-Trail Preserved
Power SupplyAC 220 V ±10%, 50 Hz ±1%
Operating Environment10–35 °C, RH ≤85% (non-condensing), Vibration- and EMI-Shielded Lab
Measurement Range0.01–0.50 mg/L CN⁻
Accuracy±5% of Full Scale
Repeatability (RSD)≤2%
Baseline Drift<0.002 A/30 min
ComplianceDesigned to support ISO/IEC 17025 workflows, GLP-compliant data integrity per FDA 21 CFR Part 11 (audit trail enabled)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERUN
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelERUN-SLBOD-B
Instrument TypeLaboratory BOD Analyzer
Measurement PrincipleMercury-Free Pressure Differential Method
Measurement Range0–4000 mg/L (direct reading)
Detection Limit5 mg/L
Accuracy±8%
Repeatability≤3%
Resolution0.01 mg/L
Sampling Points per CycleUp to 60
Incubation Bottle Volume580 mL
Temperature Control20 ±1 °C
Incubation Duration1–30 days (user-selectable)
Data Storage Capacity≥10 years of measurement records
Power SupplyAC 220 V ±10%, 50–60 Hz
Battery BackupIntegrated Li-ion, >2 years service life
Number of Independent Channels6
Stirring MechanismProgrammable magnetic stirring
DisplayLarge backlit LCD
Added to wishlistRemoved from wishlist 0
Add to compare
BrandERUN
OriginShaanxi, China
Manufacturer TypeAuthorized Distributor
Country of OriginChina
ModelERUN-SZ1-A-K3
PriceUpon Request
Measurement PrincipleConstant-Voltage Electrochemical (Membrane-Free)
Range0–20.00 mg/L
Resolution0.01 mg/L
Accuracy±1% FS
Temp. Compensation0–60 °C
Output4–20 mA (4-wire, max 750 Ω)
CommunicationRS-485 (Modbus RTU, partial compatibility)
Relay Outputs2 × AC220 V / 3 A (High/Low Alarm)
DisplayDot-matrix LCD with Chinese UI
Enclosure RatingIP65
Housing MaterialABS
MountingPanel-mount (92 × 92 mm cutout, 100 × 106 × 168 mm unit)
Power SupplyAC220 V or DC24 V/12 V
Data Storage50 data points + optional historical trend logging (50 groups)
WatchdogIntegrated
Backup Memory Retention>10 years
Auto Calibration RecognitionSupported
Temp. SensorBuilt-in, automatic compensation
Software OptionPC-based data acquisition & analysis suite (optional)