Labtemp iCooler-2009+ and iCooler-4009+ Closed-Loop High-Low Temperature Circulating Chillers
| Brand | Labtemp |
|---|---|
| Origin | Guangdong, China |
| Manufacturer Type | Authorized Distributor |
| Product Origin | Domestic (China) |
| Model | iCooler-2009+ / iCooler-4009+ |
| Quotation | Available upon Request |
| Temperature Range | −20 °C to 100 °C (iCooler-2009+) / −40 °C to 100 °C (iCooler-4009+) |
| Temperature Stability | ±0.05 °C |
| Refrigeration Capacity @ 20 °C | 1200 W / 1500 W |
| Heating Power | 1500 W / 2000 W |
| Pump Pressure | 1.0 bar |
| Flow Rate | 22 L/min |
| Bath Volume | 9 L |
| Display | TFT Touchscreen |
| Communication Interface | Optional RS232 / USB |
| Power Supply | 230 V / 50 Hz |
| External Tubing Compatibility | 8 mm ID insulated tubing |
| Ambient Operating Humidity | 5–32 °C |
Overview
The Labtemp iCooler-2009+ and iCooler-4009+ are precision-engineered closed-loop circulating chillers designed for stable, bidirectional temperature control in demanding laboratory applications. These units operate on a dual-mode thermoregulation principle—combining proportional refrigeration with high-resolution PID feedback control—to deliver consistent thermal output across wide operating ranges (−20 °C to 100 °C for the iCooler-2009+, and −40 °C to 100 °C for the iCooler-4009+). Unlike open-bath systems, their sealed reservoir architecture eliminates evaporation losses and contamination risks while enabling integration with external equipment via insulated 8 mm ID tubing. The chiller’s compact footprint (300 × 480 × 630 mm) allows benchtop or fume hood installation without compromising cooling capacity or thermal stability—critical for sensitive analytical workflows where ±0.05 °C temperature uniformity is required.
Key Features
- Integrated safety architecture: Dual-level liquid level monitoring, dry-run protection, overtemperature cutoff, overpressure sensing, and overcurrent detection—all with audible/visual alarm activation and alphanumeric error code display for rapid diagnostics.
- High-reliability circulation system: Maintenance-free pressure/suction pump rated to 1.0 bar, engineered to tolerate suspended particulates (e.g., glass microfragments or fiber debris), with automatic flow and pressure modulation to prevent mechanical stress on fragile external apparatus such as rotary evaporator condensers or jacketed reactors.
- Independent control logic: Refrigeration and circulation functions can be operated separately or concurrently—enabling precise decoupling of thermal load management from fluid delivery timing.
- Calibration-ready temperature sensing: Pt100 platinum resistance thermometer with traceable single-point and two-point calibration capability, supporting ISO/IEC 17025-compliant verification protocols.
- Robust human-machine interface: IP65-rated waterproof membrane keypad, high-brightness TFT touchscreen display, configurable buzzer (muteable), and user-defined temperature limits for both upper and lower setpoints.
- Energy-efficient operation: Proportional refrigeration control minimizes compressor cycling; combined with intelligent PID tuning, it reduces power consumption without sacrificing response time or steady-state accuracy.
- Environmental compliance: Uses non-ozone-depleting, low-GWP refrigerant meeting EU F-Gas Regulation (EU No. 517/2014) and RoHS Directive 2011/65/EU requirements.
Sample Compatibility & Compliance
The iCooler series is compatible with a broad spectrum of laboratory instrumentation requiring external thermal regulation—including rotary evaporators (up to 3 L capacity), jacketed bioreactors, distillation columns, Kjeldahl digesters, Soxhlet extractors, capillary viscometers, electrophoresis tanks, calorimeters, refractometers, and polarimeters. Its sealed bath design prevents solvent ingress and cross-contamination during extended operation. Units conform to IEC 61010-1:2010 safety standards for electrical equipment used in laboratory environments. While not certified for GMP manufacturing zones, the system supports GLP-aligned documentation practices through its event-logged alarm history, parameter audit trail (accessible via optional software), and firmware-upgradable architecture compliant with long-term validation needs.
Software & Data Management
Optional communication modules (RS232 or USB) enable remote command execution—including start/stop of refrigeration, pump activation, setpoint adjustment, and real-time temperature readback—via host PC or programmable logic controller (PLC). Analog interface options (0–10 V or 4–20 mA input) permit integration into centralized building management or process control systems. Device serial numbers are retrievable via embedded firmware commands, facilitating asset tracking and calibration record linkage. Although no proprietary cloud platform is provided, raw data export (CSV/TXT) and basic SCPI-like command syntax ensure compatibility with third-party lab information management systems (LIMS) and electronic lab notebooks (ELN).
Applications
These chillers serve as primary thermal management solutions in synthetic chemistry labs (e.g., exothermic Grignard reactions requiring sub-zero jacket cooling), QC/QA testing environments (USP <797> compliant aseptic processing support), and analytical core facilities (HPLC column oven pre-cooling, GC-FID detector temperature stabilization). Their −40 °C capability on the iCooler-4009+ model enables cryogenic crystallization studies and low-temperature enzymatic assays. The 9 L reservoir volume and 22 L/min flow rate sustain stable heat exchange even under high thermal loads typical of 20 L pilot-scale reactors or multi-instrument manifold configurations.
FAQ
Can the iCooler-2009+ be used with glass vacuum systems?
Yes—the integrated pressure-regulated pump and soft-start circulation logic minimize hydraulic shock, reducing risk of implosion in thin-walled glassware.
Is firmware update supported in the field?
Yes—updates are delivered via USB stick using vendor-provided utilities; version history and checksum verification are included.
Does the unit meet electromagnetic compatibility (EMC) requirements for shared lab spaces?
Yes—it complies with EN 61326-1:2013 Class B emission limits for laboratory use.
What is the maximum allowable ambient temperature for continuous operation?
32 °C, provided relative humidity remains below 80% non-condensing and ventilation clearances (≥100 mm rear/side) are maintained.
Can the chiller maintain temperature during a brief power interruption?
Yes—equipped with auto-restart functionality that resumes prior operational state within 30 seconds after power restoration, preserving thermal continuity for time-sensitive experiments.