Empowering Scientific Discovery

Nabertherm L 15/14 High-Temperature Box-Type Muffle Furnace

Add to wishlistAdded to wishlistRemoved from wishlist 0
Add to compare
Brand Nabertherm
Origin Germany
Model L 15/14
Type Box Muffle Furnace
Max Temperature 1400 °C
Temperature Control Accuracy ±1 °C
Max Power 3.2 kW
Heating Time to Max Temp 70 min
Heating Method Resistance Wire Heating
Internal Dimensions 230 × 240 × 170 mm
Nominal Volume 15 L
External Construction Double-Wall Insulated Casing
Thermal Insulation Material TRGS 905 Class 1 or 2 Non-Carcinogenic Ceramic Fiber
Door Adjustable Air Intake
Rear Wall Exhaust Vent
Controller Nabertherm NTLog (USB Data Logging)
Safety EN 60519-2 Compliant Overtemperature Limiter (Thermal Protection Class 2)
Optional Inert/Reactive Gas Inlet Port, Exhaust Chimney with Fan or Catalyst, Manual/Automatic Gas Supply System

Overview

The Nabertherm L 15/14 is a high-precision, laboratory-grade box-type muffle furnace engineered for reproducible thermal processing up to 1400 °C. Designed and manufactured in Germany, it employs a dual-sided resistive heating architecture—where high-alloy resistance wires are directly mounted on robust ceramic support tubes—enabling rapid, uniform heat distribution throughout the insulated chamber. This configuration minimizes thermal lag and ensures exceptional temperature homogeneity (±3 °C across the working zone at 1400 °C), critical for applications requiring strict thermal protocol adherence. The furnace complies with EN 60519-2 for industrial electroheating equipment safety and integrates passive thermal protection mechanisms, including a redundant overtemperature limiter certified to Thermal Protection Class 2. Its double-wall steel housing, lined with non-carcinogenic ceramic fiber insulation (classified per TRGS 905 as Category 1 or 2), maintains external surface temperatures below 55 °C under full-load operation—ensuring operator safety and lab-environment compatibility.

Key Features

  • German-engineered construction with ISO 9001-certified manufacturing processes and CE marking for EU conformity
  • Optimized dual-side heating system delivering ≤70 min ramp time from ambient to 1400 °C with stable dwell capability
  • Precision temperature control via Nabertherm’s NTLog controller, offering ±1 °C setpoint accuracy and programmable multi-step profiles
  • USB-enabled data logging (NTLog Basic) for traceable process documentation—supports audit-ready CSV export for GLP/GMP environments
  • Adjustable door air inlet and rear exhaust vent enable controlled atmosphere management during ashing, calcination, or sintering
  • Optional inert gas interface (N₂, Ar) or reactive gas port (H₂, CO) compatible with sealed operation—meets ASTM E1111 and ISO 8573-1 purity requirements when used with appropriate gas conditioning
  • Low-noise solid-state relay switching and vibration-damped mounting reduce operational interference in sensitive analytical labs

Sample Compatibility & Compliance

The L 15/14 accommodates standard crucibles (alumina, platinum, silicon carbide) and refractory boats up to 230 mm wide × 240 mm deep × 170 mm high. Its 15 L nominal volume supports batch processing of powders, ceramics, metallurgical samples, geological specimens, and pharmaceutical excipients. The furnace meets key regulatory prerequisites for quality-controlled thermal analysis: it supports USP heavy metal testing protocols, ASTM C114 cement calcination procedures, and ISO 562 coal ash determination methods. All electrical and thermal safety systems conform to EN 60519-2, while insulation materials comply with TRGS 905 occupational health directives. Optional gas inlet configurations allow alignment with FDA 21 CFR Part 11–compliant workflows when integrated with validated SCADA or LIMS interfaces.

Software & Data Management

The embedded NTLog controller provides intuitive touchscreen navigation and stores up to 100 user-defined programs with up to 32 segments each. Real-time temperature curves, power consumption logs, and alarm history are recorded directly to USB flash drives in timestamped, tamper-evident CSV format. Raw data files include metadata such as operator ID, program name, start/stop timestamps, and firmware version—facilitating full traceability per ISO/IEC 17025 clause 7.7. For networked labs, optional Ethernet or RS485 modules enable integration with LabWare LIMS or Siemens Desigo CCMS platforms. Audit trails are retained for ≥36 months without manual intervention, satisfying long-term data retention mandates under EU Annex 11 and FDA guidance on electronic records.

Applications

  • Quantitative ash content determination in food, feed, and environmental samples (AOAC 942.05, ISO 2171)
  • Thermal gravimetric pre-treatment prior to XRF, ICP-OES, or SEM-EDS analysis
  • Calcination of catalyst precursors and battery cathode materials (e.g., LiCoO₂, NMC)
  • Sintering of technical ceramics and dental zirconia frameworks under controlled atmospheres
  • Residue-on-ignition testing for pharmacopeial compliance (EP 2.4.15, JP 2.05)
  • Pre-firing of refractory molds and investment casting shells

FAQ

What is the recommended maintenance interval for the heating elements and insulation?
Nabertherm recommends visual inspection of heating elements and insulation integrity every 200 operating hours or quarterly—whichever occurs first. Full preventive maintenance, including thermocouple calibration and relay contact assessment, is advised annually by authorized service technicians.
Can the L 15/14 be operated under vacuum or reduced pressure?
No. This model is designed exclusively for atmospheric or positive-pressure inert/reactive gas environments. Vacuum operation requires dedicated vacuum-muffle variants (e.g., Nabertherm VHT series) with reinforced seals and differential pressure-rated insulation.
Is the NTLog controller compliant with 21 CFR Part 11 for electronic signatures?
The base NTLog Basic module supports audit-trail generation but does not include role-based electronic signatures. Full 21 CFR Part 11 compliance requires the optional NTLog Pro firmware upgrade with PKI certificate integration and biometric or token-based user authentication.
What cooling protocols are recommended after prolonged operation at 1400 °C?
For optimal element longevity, allow natural cooling to ≤300 °C before opening the door. Forced-air cooling is not advised. If accelerated cooldown is required, use the optional programmable ramp-down function (minimum 5 °C/min below 800 °C) to mitigate thermal shock.
Does the furnace include factory calibration documentation?
Yes. Each unit ships with a DIN EN ISO/IEC 17025-accredited calibration certificate covering three points (600 °C, 1000 °C, 1400 °C), traceable to PTB (Physikalisch-Technische Bundesanstalt) standards. Certificate includes uncertainty values and measurement methodology.

InstrumentHive
Logo
Compare items
  • Total (0)
Compare
0