BrandGeonica
OriginSpain
ModelSunTracker-3000
Power Consumption<3 W
Azimuth & Elevation Accuracy0.1° (passive), 0.02° (active with optional radiometer feedback)
Payload Capacity30 kg
Operating Temperature-20 to +60 °C
Relative Humidity0–100% RH
Weight25 kg
Dimensions460 × 490 × 490 mm
Drive MechanismPrecision worm-gear train
Torque35 N·m
Angular Velocity9.4°/s
Angular Acceleration136.4°/s²
MountingTripod base with dual bubble levels
Housing MaterialRust-resistant aluminum alloy, 304 stainless steel worm, bronze gear
Communication InterfaceRS-485 (external control module), RS-232/422/485 & Ethernet (METEODATA data logger)
Time SynchronizationInternet NTP or integrated GPS receiver
Positioning Update RateReal-time, 1 Hz (solar zenith and azimuth)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRMAR
OriginUSA
ModelTM275LHW
Power Output1000 W
Operating Frequency BandsLow Band 42–65 kHz (beam width 25°–16°), High Wideband 150–250 kHz (constant 25° beam width)
Max Depth Range914 m (low band), 152 m (high wideband)
Beam Mounting Angle Adjustment3°–21°
Housing MaterialSEALCAST™ seamless polyurethane encapsulation
Mounting TypeTransom-mount stainless steel bracket
Sensor Weight4 kg
Compatible Hull TypesAll hull materials (fiberglass, aluminum, wood, composites)
Hull Length Requirement≥10 m
Temperature SensorIntegrated fast-response thermistor
Total Frequency Span123 kHz
Added to wishlistRemoved from wishlist 0
Add to compare
BrandCampbell Scientific
ModelCR800
OriginUSA
Differential Input Channels3 (6 single-ended)
Analog Input Resolution13-bit A/D
Scan RateUp to 100 Hz
Operating Temperature Range0 to 40 °C
Voltage Measurement Resolution0.33 µV
Sleep Mode Current Draw~0.6 mA
Active Current Draw (w/o RS-232)1–16 mA
Active Current Draw (w/ RS-232)17–28 mA
Communication Interfaces1 × CS I/O port, 1 × RS-232 serial port
Supported ProtocolsPakBus®, Modbus RTU/ASCII, SDI-12, SDM, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, NTP
Onboard Memory4 MB (data + program storage)
Data FormatTabular ASCII
Operating SystemPakBus OS
Compatible SoftwareLoggerNet, PC400, Short Cut
Optional PeripheralCR1000KD handheld display
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRMAR
OriginUSA
ModelM265LM
Frequency BandsLow Band 42–65 kHz (Beamwidth 25°–16°), Medium Band 85–135 kHz (Beamwidth 16°–11°)
Output Power1000 W
Installation TypeIn-hull Mount
Housing MaterialPolyurethane Encapsulated Plastic
Transducer WindowPolyurethane
Cable Length10 m
Integrated Temperature SensorYes
Weight6.2 kg
Total Bandwidth73 kHz
Compatible Frequencies50 kHz, 88 kHz, 107 kHz
Hull CompatibilitySolid Fiberglass Hulls Only
Proprietary TechnologyXducer ID®
Added to wishlistRemoved from wishlist 0
Add to compare
BrandRainWise
OriginUSA
ModelPG/H
ConstructionAnodized aluminum housing, stainless steel components, low-surface-tension polymer tipping bucket
HeatingIntegrated thermostatically controlled heater (activates below 1°C)
Switch TypeReed switch
OutputMomentary closure pulse (< 0.1 s duration)
Resolution Options0.1 mm, 0.2 mm, or 0.25 mm per tip
Accuracy±0.5% at 12.5 mm/h rainfall rate
Dimensions21.9 cm diameter × 31.75 mm height
ComplianceDesigned for continuous outdoor deployment in accordance with WMO Guide to Instruments and Methods of Observation (CIMO Guide), ISO 9060:2018 Class B performance expectations for precipitation measurement
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model41502
MaterialUV-stabilized white thermoplastic housing, anodized aluminum support frame, stainless steel mounting hardware
Dimensions20 cm (diameter) × 33 cm (height)
Net Weight1.1 kg
Shipping Weight~2.7 kg
Power Supply12–14 VDC @ 500 mA
Airflow Rate5–11 m/s (16–35 ft/s), dependent on sensor power draw
Radiative Error (Temperature)≤0.2 °C RMS at 1000 W/m² solar irradiance
Delta-T Error≤0.05 °C RMS under identical shielding exposure
Fan Lifetime>80,000 hours continuous operation at 25°C
Sensor CompatibilityRTD-based temperature probes (e.g., 41342), combined RH/T probes (e.g., 41382)
Output Options4–20 mA or 0–1 VDC
Operating EnvironmentOutdoor, all-weather, low-wind-speed microclimates
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRMAR
OriginUSA
ModelDX900+
Operating Frequency360 kHz
Depth Range60 m
Longitudinal Speed Range±60 knots
Transverse Speed Range±6 knots
Speed Accuracy±0.1 knots (≤10 kn), ±1% (>10 kn)
Speed Resolution0.01 knots
Temperature Accuracy±0.5 °C
Data Update Rateup to 10 Hz
Operating Temperature−15 °C to +55 °C
Power Supply9–16 VDC
Power Consumption5.0 W (DST variant), 2.5 W (ST variant)
Cable Length3 m (DST), 6 m (ST)
NMEA 2000® Load Equivalent Number (LEN)10
Weight1 kg
Housing MaterialMarine-grade corrosion-resistant alloy
Output ProtocolsNMEA 0183 (ST), NMEA 2000® (DST)
Wireless InterfaceBluetooth 5.0 for AIRMAR CAST™ app
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirmar
OriginUSA
ModelB164
Operating Frequencies50 kHz / 200 kHz
Beamwidth22° × 20° @ 50 kHz
Output Power1000 W
Mounting TypeThrough-Hull (Low-Profile)
Housing MaterialBronze
Transducer WindowPolyurethane
Hole Diameter95 mm
Shaft Length71 mm
Cable Length10 m
Integrated Temperature SensorYes
Tilt Options0°, 12°, or 20°
Maximum Hull Angle24°
Weight1.4 kg
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model05305
Instrument TypeCup Anemometer & Wind Vane Sensor
Resolution0.1 m/s
Measurement Range0–50 m/s (wind speed), 0–360° (wind direction)
Accuracy±0.2 m/s or ±1% of reading (wind speed), ±3° (wind direction)
Startup Wind Speed0.4 m/s (cup), 0.5 m/s (vane)
Operating Temperature−50°C to +50°C
Operating Humidity0–100% RH
Output OptionsAC pulse (3 pulses/rev), 0–5 VDC, or 4–20 mA
Housing MaterialUV-stabilized polymer with stainless steel and anodized aluminum hardware
Bearing TypePrecision stainless steel ball bearings
ComplianceEPA PSD Guidelines, NRC RG 1.23, ANSI/ANS-18.1
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirmar
OriginUSA
Model33-627-02
Measurement Range10–95% RH
Accuracy±5% RH
Resolution1% RH
IP Rating (when installed)IPX4
Compatible SystemsAirmar 110WX, 120WX, 150WX, 200WX, 220WX Weather Stations
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGill
OriginUnited Kingdom
ModelMetpak
Instrument TypePortable Weather Station
Enclosure RatingIP65
Operating Temperature−35 °C to +70 °C
Power Supply5–30 V DC (<16 mA @ 12 V, 1 Hz output)
Wind MeasurementUltrasonic (no moving parts)
Wind Speed Range0–60 m/s
Wind Direction Range0–359°
Wind Accuracy±2% @ 12 m/s (speed), ±3° @ 12 m/s (direction)
Air Temperature SensorPt100 1/3 Class B
Temp Range−35 °C to +70 °C
Temp Accuracy±0.1 °C
Relative Humidity SensorRotronic HygroClip HC2-53
RH Range0–100% RH
RH Accuracy±0.8% RH @ 23 °C
Barometric Pressure SensorHigh-precision capacitive
Pressure Range600–1100 hPa
Pressure Accuracy±0.5 hPa
Dew Point Accuracy±0.15 °C (at 23 °C ambient, 20 °C dew point)
Output ProtocolsASCII, NMEA 0183, SDI-12 v1.3, Modbus RTU/ASCII
Communication InterfacesRS232, RS422, RS485 (2-wire), SDI-12
Baud Rates4800–57600 (ASCII), 1200 (SDI-12)
Data Update Intervals1 s, 2 s, 4 s, or polled
MountingAnodized aluminum U-bracket for vertical masts Ø30–58 mm
Weight2.1 kg (including bracket)
MaterialsUV-stabilized white engineering plastic housing, anodized aluminum mounting hardware
Added to wishlistRemoved from wishlist 0
Add to compare
BrandGILL
OriginUnited Kingdom
ModelMetPak Pro
Instrument TypePortable Weather Station
Enclosure RatingIP65
Operating Temperature−35°C to +70°C
Power Supply5–30 VDC (<26 mA @12 V, 1 Hz output)
Communication InterfacesRS232 / RS422 / RS485 (2-wire) / SDI-12 (user-selectable)
Output ProtocolsASCII, SDI-12 v1.3, NMEA 0183, Modbus RTU/ASCII
Data Logging Interval1 s / 2 s / 4 s / polled mode
Analog Inputs2 channels (0–5 V, 4–20 mA, or self-powered)
PT100 Input4-wire, IEC 60751 Class B compliant
Digital InputReed-switch or contact-closure for tipping-bucket rain gauge (up to 10 Hz)
ADC Resolution12-bit, ±0.1% of reading + 35 µV offset compensation
Wind MeasurementUltrasonic (GILL WindSonic), 0–60 m/s, 0–359°, ±2% @12 m/s (wind speed), ±3° @12 m/s (wind direction), resolution 0.01 m/s / 1°
Air TemperaturePt100, −35°C to +70°C, ±0.1°C accuracy, 0.1°C resolution
Relative HumidityRotronic HygroClip probe, 0–100% RH, ±0.8% RH @23°C, 0.1% RH resolution
Atmospheric PressureBarometric sensor, 600–1100 hPa, ±0.5 hPa, 0.1 hPa resolution
Dew Point TemperatureCalculated, ±0.15°C accuracy @23°C ambient / 20°C dew point, 0.1°C resolution
Added to wishlistRemoved from wishlist 0
Add to compare
BranddataTaker
OriginImported
ModelDT82I
Analog Inputs6 single-ended / 4 differential / 2 three- or four-wire
Resolution18-bit
Sampling Rateup to 40 Hz
Analog Output16-bit DAC, 0–10 V or 0–20 mA
Excitation Outputs5 V / 12 V selectable, max. 150 mA
Digital I/O & Counter32-bit, up to 100 kHz
Communication PortsRJ45, RS232 (host), RS232/RS485/RS422
ProtocolsMODBUS RTU (master/slave), MODBUS TCP/IP, ASCII, SDI12
Power Supply10–30 VDC
Operating Temperature−40 to +70 °C
Enclosure RatingIP54
Dimensions180 × 137 × 65 mm
Weight900 g
Internal Storage128 MB CompactFlash (upgradable to 4 GB), optional 8 GB USB storage
Real-Time Clock Accuracy±1 min/year (0–40 °C), ±4 min/year (−40–70 °C)
Built-in Battery6 V @ 1.2 Ah
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVaisala
OriginFinland
ModelPWD22
Visibility Measurement Range (MOR)10–20,000 m
Accuracy±10% (10 m–10 km), ±15% (10–20 km)
Precipitation Detection Sensitivity≤0.05 mm/h (within 10 min)
Operating Temperature−40 °C to +60 °C
Power Supply12–50 VDC (electronics)
Power Consumption2 W (standard), 65 W (with heater)
Output InterfaceRS-232 / RS-485
Dimensions40.4 × 69.5 × 19.9 cm
Weight3 kg
Ingress ProtectionIP66
EMC ComplianceCISPR 16-1/-2, IEC 61000-4-2/-3/-4/-5/-6
Weather Type Recognition7 precipitation types (rain, freezing rain, drizzle, freezing drizzle, rain/snow mix, snow, sleet), fog, haze (smoke, dust), clear sky
Reporting StandardsWMO FM-12 (SYNOP), FM-15 (METAR), NWS code tables
Precipitation MeasurementIntensity, accumulation, new snow depth estimation
Optical PrincipleForward scatter
Calibration ReferenceCertified atmospheric transmissometer traceable to national standards
Added to wishlistRemoved from wishlist 0
Add to compare
BrandBelfort (USA)
OriginUSA
Manufacturer TypeAuthorized Distributor
Origin CategoryImported
ModelModel 6000
PriceUSD 9,200 (FOB US Port)
Discontinued — Replacement ModelModel 6400
Measurement PrincipleForward Scatter (42° scattering angle)
Range6 m to 80 km
Accuracy±10% or ±3 m (whichever greater)
Light SourceHigh-output infrared LED
Analog Outputs0–1 V, 0–5 V, 0–10 V, 4–20 mA
Alarm Outputs2-channel TTL (user-configurable thresholds)
Digital InterfaceRS-232 / RS-422, 300–38,400 baud
Operating Temperature−40 °C to +55 °C
Relative Humidity0–100 % RH
Power Supply110 VAC / 220–240 VAC / 12 VDC
Power Consumption12 W (standard), 17 W (with Ambient Light Sensor), 25 W (with heated shroud)
Dimensions978 mm × 343 mm × 425 mm
Weight8.75 kg
MountingU-bolt bracket
Max Wind Speed Tolerance60 m/s
Housing MaterialCorrosion-resistant aluminum alloy
Lens HeaterStandard
Optional Heated ShroudAvailable (Part No. 96916-01)
Calibration KitOptional (Part No. 90001)
ComplianceCE Marked
FCC Compliance47 CFR Part 15
Environmental CertificationIP65 equivalent
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHukseflux
OriginNetherlands
ModelSR20
Calibration TraceabilityWorld Radiometric Reference (WRR)
ISO 90602018 Classification: Secondary Standard
Measurement Range0–4000 W/m²
Spectral Range285–3000 nm
Sensitivity15 × 10⁻⁶ V/(W/m²)
Calibration Uncertainty< 1.2 % (k = 2)
Zero Offset (a)< 5 W/m² (unventilated), 2.5 W/m² (with VU01 ventilation unit)
Operating Temperature−40 to +80 °C
Temperature Response< ±1 % (−10 to +40 °C)
Directional Response ReportIncluded
Temperature Dependence CharacterizationIndividual quadratic polynomial provided per unit
Heating Power1.5 W @ 12 VDC
Output SignalAnalog voltage (mV)
Supply Voltage8–30 VDC
Integrated Temperature SensorPt100 or 10 kΩ thermistor
Cable Length5 m (extendable in 5-m increments)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirmar
OriginUSA
ModelST850
OutputNMEA 2000® or Analog (selectable)
Speed Range2–45 knots (2–52 MPH)
Temperature Accuracy±0.5°C
Operating Temp−10°C to +40°C
Sampling Interval1 s
Pressure Rating3 m
Transducer Window MaterialPolyurethane
Hull Tilt Limit≤22°
Pulse Frequency17,000 p/nm (4.8 Hz per knot)
Supply Voltage9–16 VDC
Current Draw<200 mA
NMEA 2000 LEN2
ComplianceIEC 60945
Weight (Plastic/Bronze/Stainless)0.7 / 1.3 / 1.6 kg
Standard Cables6 m NMEA 2000, 9 m Analog
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirmar
OriginUSA
ModelP39
Operating Frequency235 kHz
Mounting TypeThrough-Hull Beam-Mount
Depth Range0.5–100 m (NMEA 0183), 0.5–150 m (NMEA 2000)
Speed SensingPaddlewheel with Grooved Flow Channel
Temperature Range−10 to +40 °C
Temp Accuracy±0.5 °C
Beam Angle Adjustment0°–22°
Weight0.5 kg
Pressure Rating3 m
Pulse Resolution20,000 pulses per nautical mile
Power Supply10–28 VDC (NMEA 0183), 9–16 VDC (NMEA 2000)
Current Draw<40 mA (NMEA 0183), <200 mA (NMEA 2000)
NMEA 2000 LEN4
ComplianceIEC 60945
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAIRMAR
OriginUSA
ModelCM599LH
Frequency BandsLow Band 28–60 kHz (Beamwidth 23°–9°), High Band 130–210 kHz (Beamwidth 8°–4°)
Total Bandwidth112 kHz
Transmit Power2000–3000 W
Mounting TypeIn-Tank Installation
Hull CompatibilitySolid Fiberglass
Enclosure MaterialEpoxy-Resin Housing
Weight13.73 kg
Cable Length10 m
Integrated Temperature SensorNo
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirmar
OriginUSA
ModelUST850
Output ProtocolsNMEA 0183, NMEA 2000®
Speed Range0.1–50 knots
Operating Temperature−4 to 40 °C
Transmit Frequency4.5 MHz
Pulse Repetition Frequency0.5–12 kHz (adaptive)
Supply Voltage9–16 VDC
Average Current Draw125 mA @ 12 VDC
Housing MaterialPlastic / Bronze / Stainless Steel
Through-Hull Diameter51 mm
Weight1.4 kg (plastic), 1.8 kg (bronze)
Added to wishlistRemoved from wishlist 0
Add to compare
BrandVaisala
OriginFinland
ModelWXT534
Instrument TypePortable Weather Station
Temperature Range−52 to +60 °C
Relative Humidity Range0–100 %RH
Atmospheric Pressure Range600–1100 hPa
Temp. Resolution0.1 °C
RH Resolution0.1 %RH
Pressure Resolution0.1 hPa
Temp. Accuracy±0.3 °C @ 20 °C
RH Accuracy±3 %RH (0–90 %RH), ±5 %RH (90–100 %RH)
Pressure Accuracy±0.5 hPa (0–30 °C)
Output OptionsSDI-12 v1.3, RS-232, RS-485, RS-422
Communication ProtocolsASCII auto/polling, NMEA 0183 v3.0
Power Supply6–24 VDC
Avg. Current Consumption0.1 mA (SDI-12 standby), 3 mA (typical, default interval), 15 mA (max, continuous measurement)
Heater Supply12–24 VDC / 12–17 VAC
Heater Current0.8 A @ 12 VDC, 0.4 A @ 24 VAC
Enclosure RatingIP65 (without mounting adapter), IP66 (with mounting adapter)
Operating Temp.−52 to +60 °C
Storage Temp.−60 to +70 °C
Weight<1.2 kg
DimensionsØ140 × 200 mm
Added to wishlistRemoved from wishlist 0
Add to compare
BrandHORIBA
OriginUSA
ModelD-50
Measurement ParameterspH, Temperature, ORP, Conductivity (D-54), Dissolved Oxygen (D-55), Ion Selective Electrode (ISE) capability (D-53)
Enclosure RatingIP67
Power SupplyDC 3 V (LR6 batteries)
Weight300–330 g
InterfaceRS-232C for PC/printer connectivity
DisplayBacklit LCD with dual-channel readout
Data LoggingAutomatic storage with timestamp
Self-Diagnostic FunctionYes
Electrode CompatibilityRuggedized waterproof pH/ORP probes, interchangeable sensor modules
Added to wishlistRemoved from wishlist 0
Add to compare
BrandAirmar
OriginUSA
ModelM260
Power Output1000 W
Operating Frequencies50 kHz / 200 kHz
Beamwidth19° @ 50 kHz / 6° @ 200 kHz
Installation TypeIn-hull (through-hull cavity mount)
Housing MaterialPolyurethane & plastic
Porthole Diameter30 mm
Mounting Stub Length121 mm
Cable Length10 m
Weight6.2 kg
Hull Tilt Compensation Range0–30°
Transducer Window MaterialPolyurethane
Temperature SensorNot integrated
Compatible Hull TypesFiberglass only
Minimum Vessel Length8 m
Proprietary TechnologyXducerID®
Added to wishlistRemoved from wishlist 0
Add to compare
BrandR.M. Young
OriginUSA
Model41342
Measurement Range−50 to +50 °C
Accuracy (at 0 °C)±0.3 °C (standard), ±0.1 °C (optional)
Time Constant42 s (with 43408 radiation shield)
Sensor Type1000 Ω Pt RTD, 4-wire configuration
Output OptionsResistance (41342), 0–1 VDC (41342VC), 4–20 mA (41342LC)
CalibrationSelectable °C or °F
Recommended Radiation Shield43502 (aspirated) or 41003P (multi-plate passive)
Recommended Cable2-pair shielded, 22 AWG (P/N 18641)